Search NASA⌕ Search

SEARCH · Search NASA

Results for “high magnetic fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Helium gas bubble trapped in liquid helium in high magnetic field

High magnetic field magnets are used widely in the area of the condensed matter physics, material science, chemistry, geochemistry, and biology at the National High Magnetic Field Laboratory. New high field magnets of state-of-the-art are being pursued and developed at the lab, such as the current developing 32 T, 32 mm bore fully superconducting magnet. Liquid Helium (LHe) is used as the coolant for superconducting magnets or samples tested in a high magnetic field. When the magnetic field reaches a relatively high value the boil-off helium gas bubble generated by heat losses in the cryostat can be trapped in the LHe bath in the region where BzdBz/dz is less than negative 2100 T{sup 2}/m, instead of floating up to the top of LHe. Then the magnet or sample in the trapped bubble region may lose efficient cooling. In the development of the 32 T magnet, a prototype Yttrium Barium Copper Oxide coil of 6 double pancakes with an inner diameter of 40 mm and an outer diameter of 140 mm was fabricated and tested in a resistive magnet providing a background field of 15 T. The trapped gas bubble was observed in the tests when the prototype coil was ramped up to 7.5 T at a current of 200 A. This letter reports the test results on the trapped gas bubble and the comparison with the analytical results which shows they are in a good agreement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nb3Sn High Field Magnets for the High Luminosity LHC Upgrade Project

The High Luminosity upgrade of the Large Hadron Collider at CERN requires a new generation of high field superconducting magnets. High field large aperture quadrupoles (MQXF) are needed for the low-beta triplets close to the ATLAS and CMS detectors, and high field two-in-one dipoles (11 T dipoles) are needed to make room for additional collimation. The MQXF quadrupoles, with a field gradient of 140 T/m in 150 mm aperture, have a peak coil field of 12.1 T at nominal current. The 11 T dipoles, with an aperture of 60 mm, have a peak coil field of 11.6 T at nominal current. Both magnets require Nb3Sn conductor and are the first applications of this superconductor to actual accelerator magnets.

43 PARTICLE ACCELERATORS↗

Measurements of the Strain Dependence of Critical Current of Commercial REBCO Tapes at 15 T Between 4.2 and 40 K for High Field Magnets

Interest for high magnetic fields (>16 T) for applications in high energy physics (HEP) and fusion machines, requires the development of high current cables capable to withstand the large forces, mechanical and electromagnetic, experienced during manufacturing and operations. The critical current (I c ) of REBCO tapes depends on strain, magnetic fields, and operational temperatures. Understanding how these parameters affect the I c of the conductor will be critical to develop robust high-current REBCO cables. However, there are limited reports on the strain dependence of I c , in particular at high fields and elevated temperatures relevant for future high-field compact fusion reactor magnets. We present here I c of commercial REBCO tapes measured as a function of compressive and tensile strain (between -0.6% and +0.65%) at high magnetic fields (12 and 15 T) and different temperatures (within 4.2-40 K). Results at 4.2 and 20 K showed less than 5% reduction in the normalized I c at high strain, while a stronger strain dependence was observed at 40 K. Samples tested at 12 T and 4.2 K showed similar strain dependence as 15 T and 4.2 K. In all tested conditions, the tape experienced reversible I c reduction in both tension and compression. Finite element analysis was used to predict the residual thermal strain accumulated in the REBCO layer prior of testing to account for the effect of the cooldown. A method was also developed to account for the current sharing observed between the sample and the sample holder during the ramp of the current. Our results provide useful input for the development of high-field fusion and HEP magnets using REBCO conductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultra-High Field Magnets for X-Ray and Neutron Scattering using High Temperature Superconductors

X-ray and neutron scattering techniques are capable of acquiring information about the structure and dynamics of quantum matter. However, the high-field magnet systems currently available at x-ray and neutron scattering facilities in the United States are limited to fields of 16 tesla (T) at maximum, which precludes applications that require and/or study ultra-high field states of matter. This gap in capability—and the need to address it—is a central conclusion of the 2005 National Academy of Sciences report by the Committee on Opportunities in High Magnetic Field Science. To address this gap, we propose a magnet development program that would more than double the field range accessible to scattering experiments. With the development and use of new ultra-high field–magnets, the program would bring into view new worlds of quantum matter with profound impacts on our understanding of advanced electronic materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Faceted growth of primary Al{sub 2}Cu crystals during directional solidification in high magnetic field

The high magnetic field is widely used to modify the crystal morphology. In this work, the effect of the magnetic field on growing behavior of faceted crystals in the Al-40 wt. %Cu alloy was investigated using directional solidification technique. It was found that the faceted growth of primary Al{sub 2}Cu phase was degraded and the primary spacing was reduced upon applying the magnetic field. Additionally, the length of the mushy zone first decreased and then increased with increase of the magnetic field intensity. The quantitative analysis reveals that the shear stress induced by the fluid motion is insufficient to break the atom bonds at the solid-liquid interface. However, both of the thermoelectric magnetic convection (TEMC) and the thermoelectric magnetic force (TEMF) cause dendrites to fracture and reduce the primary spacing. The two effects also weaken the faceting growth. Moreover, the instability of the solid-liquid interface is generated by the TEMF, which further leads to degrade the faceted growth. The length of mushy zone was changed by the TEMC and reached the minimum in the magnetic field of 0.5 T, which is in good agreement with the predicted value (0.83 T)

36 MATERIALS SCIENCE↗

High field magnetization of FePS 3

High field magnetization measurements in pulsed fields up to 65 T have been performed on FePS 3 , which is nominally a good example of a two-dimensional Ising-like antiferromagnet on a honeycomb lattice. Measurements with the field parallel to the moment direction confirm the presence of two first-order transitions above 35 T, to M/M sat = 1/2 and M/M sat = 1, respectively, at 4 K. The measurements are in contradiction with published estimates for the magnetic exchange parameters, but the contradiction can be resolved by allowing for anisotropic exchange parameters in the Hamiltonian. Furthermore, the magnetization with the field perpendicular to the moment direction is anisotropic, with no transitions observed for fields along the a axis while a cascade of first-order transitions is observed for fields above 50 T along the b axis, the latter case also showing a strong degradation of the sample after repeated pulses. The results indicate a strong magnetolattice coupling in FePS 3 . Temperature-dependent measurements hint at a possible tricritical point.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A nanoscale SQUID operating at high magnetic fields

A washer-free Nb nanoSQUID has been developed for measuring magnetization changes from nanoscale objects. The SQUID loop is etched into a 250 nm wide Au/Nb bilayer track and the diameter of the SQUID hole is ~ 70 nm. In the presence of a magnetic field perpendicular to the plane of the SQUID, vortex penetration into the 250 nm wide track can be observed via the critical current–applied field characteristic and the value at which vortex first penetrates is consistent with the theoretical prediction. Upon removing the applied field, the penetrated vortices escape the track and the critical current at zero field is restored.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Three-Dimensional Charge Density Wave Order in YBa2Cu3O6.67 at High Magnetic Fields

Charge density wave (CDW) correlations have been shown to universally exist in cuprate superconductors. However, their nature at high fields inferred from nuclear magnetic resonance is distinct from that measured by x-ray scattering at zero and low fields. Here we combine a pulsed magnet with an x-ray free electron laser to characterize the CDW in YBa2Cu3O6.67 via x-ray scattering in fields up to 28 Tesla. While the zero-field CDW order, which develops below T ~ 150 K, is essentially two-dimensional, at lower temperature and beyond 15 Tesla, another three-dimensionally ordered CDW emerges. The field-induced CDW onsets around the zero-field superconducting transition temperature, yet the incommensurate inplane ordering vector is field-independent. This implies that the two forms of CDW and hightemperature superconductivity are intimately linked.

Gerber, S.↗

9 T high magnetic field annealing effects on FeN bulk sample

α″-Fe{sub 16}N{sub 2} has been suggested as a promising candidate for future rare-earth-free magnets. In this paper, we report to use high magnetic field (9 T) assisted post-annealing process to enhance the Fe{sub 16}N{sub 2} phase formation in FeN bulk rod samples during the α′ → α″ phase transformation and thus improve its magnetic properties. It was found by X-ray Diffraction measurement that the volume ratio of Fe{sub 16}N{sub 2} phase was increased up to 22%, which corresponds to an increase in the amount of transformation from α′ → α″ up to 78%. Also, the saturation magnetization (M{sub s}) of the prepared FeN rod sample was increased to 227 emu/g with its coercivity up to 376 Oe at room temperature. A working mechanism for the high field assisted post-annealing process was presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assessment of Training Performance, Degradation and Robustness of Paraffin-Wax Impregnated Nb 3 Sn Demonstrator Under High Magnetic Field

In the context of high-energy physics, the use of Nb 3 Sn superconducting magnets as a cost-effective and reliable technology depends on improvements in the following areas: long development and manufacturing cycles, conductor degradation after thermal cycling, long training, as well as a demonstration in accelerator magnets with a beam aperture of the full potential of modern Nb 3 Sn conductors. In short, performance, robustness, and cost are the three issues to be addressed. The Magnet Development project (MagDev) of the Swiss Accelerator Research and Technology initiative (CHART) at the Paul Scherrer Institute (PSI) aims to contribute to the solutions to each of these issues, re-thinking the manufacturing and design process. Here in our program, every innovation is to be validated by means of a panoply of fast-turnaround tools: from non-powered and powered samples and coils, tested under background field, to low-field subscale magnets and high field short prototypes. This work presents one element in this panoply of R&D vehicles: a stress-managed Nb 3 Sn coil called BigBOX, impregnated with paraffin wax, and tested, through a collaboration with the Magnet Development Program of the United States (US-MDP), in the background field of Brookhaven National Laboratory (BNL)’s common coils dipole DCC17.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

OBSERVATIONS OF ENERGETIC HIGH MAGNETIC FIELD PULSARS WITH THE FERMI LARGE AREA TELESCOPE

We report the detection of {gamma}-ray pulsations from the high-magnetic-field rotation-powered pulsar PSR J1119-6127 using data from the Fermi Large Area Telescope. The {gamma}-ray light curve of PSR J1119-6127 shows a single, wide peak offset from the radio peak by 0.43 {+-} 0.02 in phase. Spectral analysis suggests a power law of index 1.0 {+-} 0.3{sup +0.4}{sub -0.2} with an energy cutoff at 0.8 {+-} 0.2{sup +2.0}{sub -0.5} GeV. The first uncertainty is statistical and the second is systematic. We discuss the emission models of PSR J1119-6127 and demonstrate that despite the object's high surface magnetic field-near that of magnetars-the field strength and structure in the {gamma}-ray emitting zone are apparently similar to those of typical young pulsars. Additionally, we present upper limits on the {gamma}-ray pulsed emission for the magnetically active PSR J1846-0258 in the supernova remnant Kesteven 75 and two other energetic high-B pulsars, PSRs J1718-3718 and J1734-3333. We explore possible explanations for the non-detection of these three objects, including peculiarities in their emission geometry.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of HTS Wires at High Magnetic Fields

Fermilab is working on the development of high field magnet systems for ionization cooling of muon beams. The use of high temperature superconducting (HTS) materials is being considered for these magnets using Helium refrigeration. Critical current (I{sub c}) measurements of HTS conductors were performed at FNAL and at NIMS up to 28 T under magnetic fields at zero to 90 degree with respect to the sample face. A description of the test setups and results on a BSCCO-2223 tape and second generation (2G) coated conductors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ biaxial rotation at low-temperatures in high magnetic fields

We report the design, construction, and characterization of a biaxial sample rotation stage for use in a cryogenic system for orientation-dependent studies of anisotropic electronic transport phenomena at low temperatures and high magnetic fields. Our apparatus allows for continuous rotation of a sample about two axes, both independently and simultaneously.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗