Search NASA⌕ Search

SEARCH · Search NASA

Results for “high photon flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Gas gun shock experiments with single-pulse x-ray phase contrast imaging and diffraction at the Advanced Photon Source

The highly transient nature of shock loading and pronounced microstructure effects on dynamic materials response call for in situ, temporally and spatially resolved, x-ray-based diagnostics. Third-generation synchrotron x-ray sources are advantageous for x-ray phase contrast imaging (PCI) and diffraction under dynamic loading, due to their high photon fluxes, high coherency, and high pulse repetition rates. The feasibility of bulk-scale gas gun shock experiments with dynamic x-ray PCI and diffraction measurements was investigated at the beamline 32ID-B of the Advanced Photon Source. The x-ray beam characteristics, experimental setup, x-ray diagnostics, and static and dynamic test results are described. We demonstrate ultrafast, multiframe, single-pulse PCI measurements with unprecedented temporal (<100 ps) and spatial ({approx}2 {mu}m) resolutions for bulk-scale shock experiments, as well as single-pulse dynamic Laue diffraction. The results not only substantiate the potential of synchrotron-based experiments for addressing a variety of shock physics problems, but also allow us to identify the technical challenges related to image detection, x-ray source, and dynamic loading.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Let There Be Neutrons! Hadronic Photoproduction from a Large Flux of High-energy Photons

We propose that neutrons may be generated in high-energy, high-flux photon environments via photo-induced reactions on pre-existing baryons. These photohadronic interactions are expected to occur in astrophysical jets and surrounding material. Historically, these reactions have been attributed to the production of high-energy cosmic rays and neutrinos. We estimate the photoproduction off of protons in the context of gamma-ray bursts, where it is expected there will be sufficient baryonic material that may be encompassing or entrained in the jet. We show that typical stellar baryonic material, even material completely devoid of neutrons, can become inundated with neutrons in situ via hadronic photoproduction. Consequently, this mechanism provides a means for collapsars and other astrophysical sites containing substantial flux of high-energy photons to be favorable for neutron-capture nucleosynthesis.

79 ASTRONOMY AND ASTROPHYSICS↗

Perovskite CsPbBr 3 Single-Crystal Detector Operating at 10 10 Photons s -1 mm -2 for Ultra-High Flux X-ray Detection

Semiconductors for detecting hard radiation are confronted with considerable problems when operating at high photon fluxes. A perovskite CsPbBr 3 single-crystal detector capable of operating at X-ray fluxes of up to 10 10 photons s -1 mm -2 with beam area ≤ 0.25 mm 2 at 58.61 keV for current-mode X-ray detection is reported. The spectrometer-grade melt-grown CsPbBr 3 detectors show a gamma-ray energy resolution of ~7.5% at 122 keV for 57 Co and dark current as low as 4.3 nA (0.5 nA mm -2 ) at a reverse bias voltage of 200 V (118 V mm -1 ). The detector is tested at X-ray energies of 8.2, 10, and 58.61 keV at a synchrotron light source under a reverse bias voltage of up to 1000 V (588 V mm -1 ). Under a sufficiently high bias voltage and within several hundreds of seconds X-ray exposure, good photocurrent linearity (goodness of fit R 2 > 0.99) and reproducibility are obtained up to a flux of ≈10 10 photons s -1 mm -2 at beam area 0.25 mm 2 with Lower Limit of Detection of ≈10 5 photons s -1 mm -2 and Charge Collection Efficiency of ≈100% for 58.61 keV X-rays. Therefore, wide application of CsPbBr 3 detectors in high-flux X-ray detection is anticipated.

36 MATERIALS SCIENCE↗

Microbial Methods for Testing a Novel Spacecraft Bioburden Reduction Method

In order to circumvent the contamination of microorganisms in both extraterrestrial and terrestrial environments, spacecraft hardware must often be sterilized. Current sterilization practices are both time-consuming and expensive. Techniques such as dry heat sterilization and scattered/localized electric field enhancements are incompatible with a variety of hardware materials as well as complex surface shapes. Our group is testing a novel femtosecond pulsed laser for the rapid sterilization of spacecraft hardware using high photon fluxes, which is both an efficient and effective technique to ensure a reduced microbial burden aboard spacecraft. This method is likely to be effective because microorganisms have not encountered high photon fluxes in their evolutionary history and thus contain no protective mechanisms against them. To assess the effectiveness of pulsed laser sterilization, we used a combination of scanning electron microscopy and elemental analysis for the examination of damaged spores on metal coupons, as well as microbiology methods for spore assays. The surfaces of metal coupons inoculated with Bacillus subtilis were illuminated with femtosecond pulses at various wavelengths below the damage threshold for the aluminum. After laser treatment, metal coupon samples were sonicated to dislodge spores, serially diluted, and finally plated and incubated. Results show that sterilization efficiency is favorable in some conditions. The NASA standards for spore assays are a preliminary demonstration in establishing the trend in ability to kill spores. The results show potential for the dual pulse illumination method as a sterilization technique for planetary protection applications.

Maha S Ulhaq↗

High precision photon flux determination for photon tagging experiments

The Jefferson Laboratory PrimEx Collaboration has developed and implemented a method to control the tagged photon flux in photoproduction experiments at the 1% level over the photon energy range from 4.9 to 5.5 GeV. This method has been successfully implemented in a high precision measurement of the neutral pion lifetime. Here, we outline the experimental equipment and the analysis techniques used to accomplish this. These include the use of a total absorption counter for absolute flux calibration, a pair spectrometer for online relative flux monitoring, and a new method for post-bremsstrahlung electron counting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evidence for long-term variability in the ultra high energy photon flux from Cygnus X-3

A time-correlation analysis of atmospheric Cerenkov pulses by a wide-angle photomultiplier system was previously shown to have present in it a nonrandom component which seemed associated with the Right Ascension (RA) range approx. 20+or-04h. A recent examination of multi-muon events recorded by a photon-decay detector shows a similar time-dependent effect, closely matching the previous results, supporting the suggestion that the effect is of cosmic origin. However, even though Cyg. X-3 lies well inside the region of peak intensity, it does not seem possible to ascribe to it the whole effect, for the implied photon flux appears too large to be reconciled to various gamma-ray measurements of Cyg. X-3. The original data were subjected to a phase-histogram analysis and it as found that only 2.5% of overall recorded data are compatible with a phase-dependent emission from Cyg. X-3. Assuming these events to be gamma rays yields a detected flux of (2.6 + or - 0.3) x 10 to the minus 12th power gamma cm -2s-1 above 5 x 10 to the 14th power eV. Comparing this value with more recent ultra high energy (UHE) photon data from the same source, it is suggested that the available data generally favor a long-term reduction in the Cyg. X-3 inferred luminosity ( 10 to the 13th power eV) by a factor of (1.8 + or - 0.3) per year.

Bhat, C. L.↗

Imaging of cochlear tissue with a grating interferometer and hard X-rays

This article addresses an important current development in medical and biological imaging: the possibility of imaging soft tissue at resolutions in the micron range using hard X-rays. Challenging environments, including the cochlea, require the imaging of soft tissue structure surrounded by bone. We demonstrate that cochlear soft tissue structures can be imaged with hard X-ray phase contrast. Furthermore, we show that only a thin slice of the tissue is required to introduce a large phase shift. It is likely that the phase contrast image of the soft tissue structures is sufficient to image the structures even if surrounded by bone. For the present set of experiments, structures with low-absorption contrast have been visualized using in-line phase contrast imaging and a grating interferometer. The experiments have been performed at the Advanced Photon Source at Argonne National Laboratories, a third generation source of synchrotron radiation. The source provides highly coherent X-ray radiation with high-photon flux (>10{sup 12} photons/s) at high-photon energies (5-70 keV). Radiographic and light microscopy images of the gerbil cochlear slice samples were compared. It has been determined that a 20-{micro}m thick tissue slice induces a phase shift between 1/3{pi} and 2/3{pi}.

43 PARTICLE ACCELERATORS↗

De-polarization of a CdZnTe radiation detector by pulsed infrared light

This work is focused on a detailed study of pulsed mode infrared light induced depolarization of CdZnTe detectors operating at high photon fluxes. This depolarizing effect is a result of the decrease of positive space charge that is caused by the trapping of photogenerated holes at a deep level. The reduction in positive space charge is due to the optical transition of electrons from a valence band to the deep level due to additional infrared illumination. In this paper, we present the results of pulse mode infrared depolarization, by which it is possible to keep the detector in the depolarized state during its operation. The demonstrated mechanism represents a promising way to increase the charge collection efficiency of CdZnTe X-ray detectors operating at high photon fluxes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Infrastructure development for radioactive materials at the NSLS-II

The X-ray Powder Diffraction (XPD) Beamline at the National Synchrotron Light Source-II is a multipurpose instrument designed for high-resolution, high-energy X-ray scattering techniques. In this article, the capabilities, opportunities and recent developments in the characterization of radioactive materials at XPD are described. The overarching goal of this work is to provide researchers access to advanced synchrotron techniques suited to the structural characterization of materials for advanced nuclear energy systems. XPD is a new beamline providing high photon flux for X-ray Diffraction, Pair Distribution Function analysis and Small Angle X-ray Scattering. The infrastructure and software described here extend the existing capabilities at XPD to accommodate radioactive materials. Such techniques will contribute crucial information to the characterization and quantification of advanced materials for nuclear energy applications. We describe the automated radioactive sample collection capabilities and recent X-ray Diffraction and Small Angle X-ray Scattering results from neutron irradiated reactor pressure vessel steels and oxide dispersion strengthened steels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial assessment of multilayer silicon detectors for hard X-ray imaging

Silicon detectors with lower material budget, ultrafast readout and radiation hardness are under developments. These unique features make pixelized silicon sensors a good option for hard X-ray imaging. To verify the performance of spatial resolution and energy sensitivity of silicon sensors to hard X-rays, a two layer setup of Pixelink PL-D725MU sensors has been tested at the Argonne National Laboratory Advanced Photon Source (APS) ID-10 sector with 29.2 keV high photon flux (4.5 x 10(8) to 4.5 x 10(10) photons per second) X-rays. Better than 3 mu m spatial resolution and clear energy characterization have been achieved by both layers. Commercial CMOS sensors with superior spatial resolution could be used for phase contrast imaging in current synchrotrons. These studies pave the path for future multilayer ultrafast silicon sensor development with ns to sub-ns readout speeds in hard X-ray imaging at synchrotrons and XFEL beamlines.

Hard X-ray imaging↗

Single-photon photoionization of oxygen-like Ne III

Here, we offer a theoretical and experimental study of the single-photon photoionization of Ne III. The high photon flux and the high-resolution capabilities of the Advanced Light Source at the LBNL were employed to measure absolute photoionization cross sections. The resulting spectrum has been benchmarked against high accuracy relativistic Breit-Pauli R-matrix calculations. Additionally, a large close-coupling wave function expansion which comprises up to 58 fine-structure levels of the residual ion Ne IV of configurations 2 s 2 2 p 3 , 2 s 2 p 4 , 2 p 5 , 2 s 2 2 p 2 3 s , 2 s 2 2 p 2 3 p and 2 s 2 2 p 2 3 d was included. A complete identification of the measured features was achieved by considering seven low-lying levels of Ne III. We found that the photoionization cross-section ( σ PI ) exhibits the presence of prominent resonances in the lowenergy region near the ionization thresholds that correspond to low-lying levels. These include highpeak narrow resonances with almost zero background introduced by relativistic effects. However, there does not exist a significant contribution to σ PI from relativistic effects at the high-energy interval of the present study.

32.30.Rj↗

A Beamline for Fast Polarization Switching at NSLS-II

The first XUV beamline (200-2000 eV) at NSLS-II will have two branches, one optimized for photon hungry experiments requiring high coherent flux and one optimized for studies of polarization sensitive materials and interfaces based on fast polarization switching. We describe here the branch designed for fast polarization switching with frequencies up to 1 kHz, high photon flux, and good energy resolution. The beamline will be served by two canted undulators and is based on the focusing variable line spacing grating monochromator. The two beams will be focused at the same spot of approximately 80x10 {mu}m (hor.xver.). The expected circular polarized flux at the sample from each device up to 1.4 keV will be higher than 10{sup 12} photons/s at a resolving power better than 10{sup 4}. An additional KB focusing system will deliver the two beams to a spot in the {mu}m range.

43 PARTICLE ACCELERATORS↗

Low Catalyst Loading Enhances Charge Accumulation for Photoelectrochemical Water Splitting

Abstract Solar water oxidation is a critical step in artificial photosynthesis. Successful completion of the process requires four holes and releases four protons. It depends on the consecutive accumulation of charges at the active site. While recent research has shown an obvious dependence of the reaction kinetics on the hole concentrations on the surface of heterogeneous (photo)electrodes, little is known about how the catalyst density impacts the reaction rate. Using atomically dispersed Ir catalysts on hematite, we report a study on how the interplay between the catalyst density and the surface hole concentration influences the reaction kinetics. At low photon flux, where surface hole concentrations are low, faster charge transfer was observed on photoelectrodes with low catalyst density compared to high catalyst density; at high photon flux and high applied potentials, where surface hole concentrations are moderate or high, slower surface charge recombination was afforded by low‐density catalysts. The results support that charge transfer between the light absorber and the catalyst is reversible; they reveal the unexpected benefits of low‐density catalyst loading in facilitating forward charge transfer for desired chemical reactions. It is implied that for practical solar water splitting devices, a suitable catalyst loading is important for maximized performance.

Liu, Tianying↗

Low Catalyst Loading Enhances Charge Accumulation for Photoelectrochemical Water Splitting

Abstract Solar water oxidation is a critical step in artificial photosynthesis. Successful completion of the process requires four holes and releases four protons. It depends on the consecutive accumulation of charges at the active site. While recent research has shown an obvious dependence of the reaction kinetics on the hole concentrations on the surface of heterogeneous (photo)electrodes, little is known about how the catalyst density impacts the reaction rate. Using atomically dispersed Ir catalysts on hematite, we report a study on how the interplay between the catalyst density and the surface hole concentration influences the reaction kinetics. At low photon flux, where surface hole concentrations are low, faster charge transfer was observed on photoelectrodes with low catalyst density compared to high catalyst density; at high photon flux and high applied potentials, where surface hole concentrations are moderate or high, slower surface charge recombination was afforded by low‐density catalysts. The results support that charge transfer between the light absorber and the catalyst is reversible; they reveal the unexpected benefits of low‐density catalyst loading in facilitating forward charge transfer for desired chemical reactions. It is implied that for practical solar water splitting devices, a suitable catalyst loading is important for maximized performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Final Technical Report Project: Low-Energy Photonuclear Studies at HIGS and Lund

This report summarizes a program of low-energy photonuclear studies at MAX-Lab in Lund (Sweden) and at the High Intensity Gamma Source (HIGS) at Duke University. A major emphasis has been on Compton scattering from deuterium in order to determine the electric and magnetic polarizabilities of the neutron. The studies at Lund utilized unpolarized photons at Egamma = 62-115 MeV to measure differential cross sections. The studies at HIGS utilized polarized and unpolarized photon beams (both linear and circular) at Egamma < 90 MeV. Polarization observables will be exploited to improve our understanding of the electric and magnetic polarizabilities, and in particular, double-polarization observables (using polarized targets) will be measured in the future to provide new information about the spin polarizabilities of the nucleon. The MAX-Lab experiments (using unpolarized photons) focused on an approved PAC proposal for Compton scattering on the deuteron aimed at making a precise determination of the electromagnetic polarizabilities of the neutron. At MAX-Lab we had three of the largest NaI detectors in the world, each capable of ~2% energy resolution. We have completed our measurements in two separate tagged photon energy ranges which overlap each other (62-97 MeV and 90-115 MeV) and the results of these experiments have been published. The photon beam at the High Intensity Gamma Source (HIGS) has several distinct advantages that make it unique: (1) ultra-high photon flux, ultimately reaching 100 MHz, (2) 100% linearly polarized photon beam, as well as circular polarization, (3) monoenergetic beam, with ~2% energy resolution, and (4) extremely low-background beam environment. Exploiting the high flux and polarization capabilities of the HIGS photon beam is central in the series of experiments being performed at this facility. Very little data exist on Compton scattering using polarized photons. We will exploit clear sensitivities in the polarization observables to the electric and magnetic polarizabilities of the nucleon, and we will ultimately extend these studies to the investigation of the spin polarizabilities. To accomplish these objectives, a liquid hydrogen/deuterium/helium cryotarget has been constructed at HIGS, and an array of NaI detectors has been commissioned for Compton studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-ray grating interferometer for materials-science imaging at a low-coherent wiggler source

X-ray phase-contrast radiography and tomography enable to increase contrast for weakly absorbing materials. Recently, x-ray grating interferometers were developed that extend the possibility of phase-contrast imaging from highly brilliant radiation sources like third-generation synchrotron sources to non-coherent conventional x-ray tube sources. Here, we present the first installation of a three grating x-ray interferometer at a low-coherence wiggler source at the beamline W2 (HARWI II) operated by the Helmholtz-Zentrum Geesthacht at the second-generation synchrotron storage ring DORIS (DESY, Hamburg, Germany). Using this type of the wiggler insertion device with a millimeter-sized source allows monochromatic phase-contrast imaging of centimeter sized objects with high photon flux. Thus, biological and materials-science imaging applications can highly profit from this imaging modality. The specially designed grating interferometer currently works in the photon energy range from 22 to 30 keV, and the range will be increased by using adapted x-ray optical gratings. Our results of an energy-dependent visibility measurement in comparison to corresponding simulations demonstrate the performance of the new setup.

43 PARTICLE ACCELERATORS↗

Construction of a New VUV/Soft X-ray Undulator Beamline BL-13A in the Photon Factory for Study of Organic Thin Films and Biomolecules Adsorbed on Surfaces

A planar undulator beamline, BL-13A, covering 30-1,000 eV has been constructed in the Photon Factory. The main scientific targets are investigations of organic thin films and biomolecules adsorbed on well-defined surfaces using angle-resolved photoelectron spectroscopy, X-ray photoelectron spectroscopy, and X-ray absorption spectroscopy. A variable-included-angle Monk-Gillieson mounting monochromator with varied-line-spacing plane gratings is used to achieve a high photon flux of 10{sup 10}-10{sup 12} photons/s with a high resolution (E/{Delta}E) of 7,000-30,000. A typical spot size on the sample position is estimated to be 130 {mu}m (horizontal)x40 {mu}m (vertical). After commissioning, BL-13A will be open for users from January 2010.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗