Search NASA⌕ Search

SEARCH · Search NASA

Results for “high purity isotopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High purity isotopically enriched Ge-70 and Ge-74 single crystals - Isotope separation, growth, and properties

Ge-70 and Ge-74 isotopes were successfully separated from natural Ge, and were zone purified. Several highly enriched, high purity Ge-70 and Ge-74 single crystals were grown by the vertical Bridgman method. The growth system was designed for reliable growth of low dislocation density, high purity Ge single crystals of about 4 g weight. A Ge-70 and a Ge-74 crystal were selected for complete characterization. In spite of the large surface-to-volume ratio of these ingots, both Ge-70 and Ge-74 crystals contain low electrically active chemical net-impurity concentrations of about 2 x 10 exp 12/cu cm, which is 2 orders of magnitude better than that of Ge-74 crystals previously grown by two different groups. Isotopic enrichment of the Ge-70 and the Ge-74 crystals is 96.3 percent and 96.8 percent, respectively. The residual donors and acceptors present in both crystals were identified as phosphorus and copper, respectively. In addition, less than 10 exp 11/cu cm Ga, Al, and In were found in the Ge-70 crystal.

Itoh, Kohei↗

Self-Broadening and Self-Shift Coefficients in the Fundamental Band of 12C 16O

High quality and precise measurements of self-broadened and self-shift coefficients in the fundamental band of C-12O-16 were made using spectra recorded at room temperature with the high-resolution (0.0027 cm(exp -1)) McMath-Pierce Fourier transform spectrometer located at the National Solar Observatory on Kitt Peak, Arizona. The spectral region under investigation (2008-2247 cm(exp -1)) contains the P(31) to R(31) transitions. The data were obtained using a high-purity natural isotopic sample ofcarbon monoxide and two absorption cells with pathlengths of 4.08 and 9.98 cm, respectively. Various pressures of CO were used, ranging between 0.25 and 201.2 Torr. The results were obtained by analyzing five spectra simultaneously, using a multispectrum nonlinear least-squares fitting technique. The self-broadened coefficients ranged from 0.0426(2) cm(exp -1) atm(exp -1) at 296 K to 0.0924(2) cm(exp -1) atm(exp -1) at 296 K, while the pressure-induced shift coefficients varied between -0.0042(3) cm(exp -1) atm(exp -1) at 296 K and +0.0005(l) cm(exp -1) atm(exp -1) at 296 K. The value in parentheses is the estimated uncertainty in units of the last digit. The self-broadened coefficients of lines with same values of m in the P and R branches agree close to within experimental uncertainties while the self-shift coefficients showed considerable variation within and between the two branches. The mean value of the ratios of P branch to R branch self-broadened coefficients was found to be 1.01 with a standard deviation of + or - 0.01. Comparisons of the results with other published data were made.

Devi, Malathy V.↗

CO2 laser oscillators for laser radar applications

This paper reviews the spectral purity, frequency stability, and long-term stabilization of newly developed CO2 isotope lasers. Extremely high spectral purity, and short-term stability of less than 1.5 x 10 to the -13th have been achieved. A brief description on using CO2 isotope lasers as secondary frequency standards and in optical radar is given. The design and output characteristics of a single frequency, TEM00q mode, variable pulse width, hybrid TE CO2 laser system is also described. The frequency chirp in the output has been measured and almost completely eliminated by means of a novel technique.

Freed, C.↗

Isotope Ratio Monitoring Gas Chromatography Mass Spectrometry (IRM-GCMS)

On Earth, the C-13 content of organic compounds is depleted by roughly 13 to 23 permil from atmospheric carbon dioxide. This difference is largely due to isotope effects associated with the fixation of inorganic carbon by photosynthetic organisms. If life once existed on Mars, then it is reasonable to expect to observe a similar fractionation. Although the strongly oxidizing conditions on the surface of Mars make preservation of ancient organic material unlikely, carbon-isotope evidence for the existence of life on Mars may still be preserved. Carbon depleted in C-13 could be preserved either in organic compounds within buried sediments, or in carbonate minerals produced by the oxidation of organic material. A technique is introduced for rapid and precise measurement of the C-13 contents of individual organic compounds. A gas chromatograph is coupled to an isotope-ratio mass spectrometer through a combustion interface, enabling on-line isotopic analysis of isolated compounds. The isotope ratios are determined by integration of ion currents over the course of each chromatographic peak. Software incorporates automatic peak determination, corrections for background, and deconvolution of overlapped peaks. Overall performance of the instrument was evaluated by the analysis of a mixture of high purity n-alkanes of know isotopic composition. Isotopic values measured via IRM-GCMS averaged withing 0.55 permil of their conventionally measured values.

Freeman, K. H.↗

Sample Materials Considerations for Curating and Processing Pristine MSR Samples

The perseverance rover is collecting and caching samples of Mars as part of the Mars 2020 mission, which represents the first leg of a multi-mission Mars Sample Return Campaign. The MSR Campaign is an international partnership that will result in delivery of the first martian samples to Earth that were not delivered through meteoritic infall. All meteorites, regardless of how they were handled from recovery to curation, have experienced uncontrolled entry and exposure to the terrestrial environment. Whilst meteorite deliveries are serendipitous, they are also unplanned events that require reactionary responses for recovery and curation. However, with the direct return of pristine astromaterials from another body, we are afforded the ability to design a facility in advance of sample delivery to keep those samples in a pristine (i.e., as returned) state for an indefinite period of time. Given that the curation and processing infrastructure needs to be made out of something, it is important to choose materials for the pristine curation environment that will optimize between the need to effectively process samples and the need to minimize contamination of the samples. The Johnson Space Center (JSC) has an optimized list of materials that have been used in previous sample return missions that includes 304/316 Stainless Steel, Teflon, and T6061 Aluminum (1). This set of materials are compatible with inorganic, organic, and biological cleanliness requirements and protocols. Furthermore, only these materials are permitted to come in contact with pristine samples. We note that JSC uses Neoprene and Hypalon for the gloves on their gloveboxes, but the glove material never comes in direct contact with the samples, only the approved materials. The MSR sample tubes will be made of Ti, so Ti may be an acceptable material for making tools, but the minor and trace element abundances of 304 and 316 stainless steel are well known and do not inhibit scientific investigations of metals, including HSE (2). More work is needed to determine whether the same is true for Ti alloys. In addition to defining the materials in the pristine environment, one must also choose whether the pristine environment will be under vacuum or under a specific atmospheric composition and pressure. Although JAXA has successfully implemented pristine curation vacuum chambers for their Hayabusa and Hayabusa2 samples (3), a vacuum environment is not appropriate for martian samples because it may drive deliquescence of mineral phases in the samples that are sensitive to pressure and relative humidity (4). Consequently, the pristine environment for the martian samples should be under an inert gas. It will be crucial to minimize the number of gases that come into direct contact with samples and these gases will need to be high purity and consistent throughout the pristine isolators. Samples at JSC are stored under high purity gaseous nitrogen (1). Dry N2 gas has not been a problem for N isotope studies for high-T release phases, but an additional inert atmosphere like Ar may be needed for samples where there is a particular concern about low-T release of N from bulk sample analysis. References: (1) McCubbin FM, et al. (2019) Space Science Reviews, 215, 1-81. (2) Day JMD, et al. (2018) Meteorit. Planet. Sci. 53:1283-1291. (3) Yada, T., et al., (2014). Meteorit. Planet. Sci. 49, 135-153. (4) Tosca NJ, et al. (2021). Astrobiology, in press, doi:10.1089/ast.2021.0115.

F M McCubbin↗

Characterization of Large-Area Silicon Ionization Detectors for the ACE Mission

We report on extensive tests of large-area (10cm diameter) high-purity ion-implanted silicon detectors for th Solar Isotope Spectrometer (SIS), and lithium-drifted silicon detetors for the Cosmic Ray Isotope Spectrometer (CRIS), which are under development for launch on the Advanced Composition Explorer (ACE) mission.

silicon↗

Problems with Re-Os isochron determinations

We have developed closed-system techniques for the equilibration of Os isotopes and for the calibration of Re and Os tracers using high-purity metals. The results show reproducibility of +/- 0.5% for calibrations of Os using different chunks of the same high-purity Os metal produced by vacuum arc melting. On a Re-Os evolution diagram the analyses of Negrillos and of Tocopilla are displaced along horizontal lines and are not consistent with a well-defined isochron. We conclude that is unclear whether whole-rock samples of irons of individual classes of iron meteorites (including the IIA class) define isochrons.In light of these observations, one must consider the evidence for phases in which Re and Os may become redistributed. We note that the IIA irons are composed of large or single kamacite crystals and do not contain taenite. This may hinder redistribution of Re and Os and may allow the IIA irons to define isochrons in preference to other magmatic iron classes. However, the IIA irons also include ubiquitous rhabdites, up to 20 mm in length, and troilite-daubreelite nodules. It has been observed that rhabdites are extremely rich in Pt-group elements. In addition to these considerations, Negrillos and Tocopilla were found in nitrate deposits and show evidence of corrosion. Therefore, it is possible that different samples of these meteorites have been differentially weathered, although our samples appeared fresh. We conclude that it is important to identify the phases in which Re and the PGEs are located and to address in detail the evidence for Re and Os remobilization.

Papanastassiou, D. A.↗

Hydrogen transport in iron and steel

The permeabilities of protium, deuterium, and tritium in foil specimens of Marz grade iron, 4130 steel, Armco iron, HP-9-4-20, and T-1 steels were studied at hydrogen pressures between 0.02 and 0.5 MPa over the temperature range 260-700 K. The permeability was measured by a pressure-rise method, deuterium counting with a detector, and radioactivity counting. Good agreement is found between the measurement techniques used. It is shown that the permeabilities of protium, deuterium, and tritium in iron and T-1 steel at temperatures as low as 260 K are in good agreement with the equation proposed by Gonzalez (1967). However, the permeabilities of HP-9-4-20 and 4130 steel to hydrogen are typically lower than predicted. The isotope effect on hydrogen permeability of HP-9-4-20, 4130 and T-1 steels, and high-purity iron can be estimated by an inverse square root of mass correction.

Louthan, M. R., Jr.↗

Interstellar-gas experiment (A0038)

The objectives of this experiment are to collect and isotopically analyze interstellar gas atoms around the orbit of the Earth for the purpose of obtaining new data relevant to understanding nucleosynthesis, and to study the dynamics of the interstellar wind inside the heliosphere and the isotopic composition of the interstellar medium outside the heliosphere. The experiment hardware will act as a set of simple cameras with high-purity copper-beryllium collecting foils serving as the film. The experiment housing will mount and thermally control the foils, establish the viewing angles and viewing direction, provide baffling to reject ambient neutral particles, provide a voltage grid to reject ionospheric charged particles, sequence collecting foils, control exposure times, and protect the foils from contamination during the deployment and retrieval of the LDEF. After being returned to Earth, the entrapped atoms can be analyzed by mass spectroscopy to determine the relative abundance of the different isotopes of helium and neon. An attempt will also be made to detect argon.

Lind, D. L.↗

The Genesis Mission Solar Wind Collection: Solar-Wind Statistics over the Period of Collection

The NASA Genesis spacecraft was launched August 8, 2001 on a mission to collect samples of solar wind for 2 years and return them to earth September 8, 2004. Detailed analyses of the solar wind ions implanted into high-purity collection substrates will be carried out using various mass spectrometry techniques. These analyses are expected to determine key isotopic ratios and elemental abundances in the solar wind, and by extension, in the solar photosphere. Further, the photospheric composition is thought to be representative of the solar nebula with a few exceptions, so that the Genesis mission will provide a baseline for the average solar nebula composition with which to compare present-day compositions of planets, meteorites, and asteroids. The collection of solar wind samples is almost complete. Collection began for most substrates in early December, 2001, and is scheduled to be complete on April 2 of this year. It is critical to understand the solar-wind conditions during the collection phase of the mission. For this reason, plasma ion and electron spectrometers are continuously monitoring the solar wind proton density, velocity, temperature, the alpha/proton ratio, and angular distribution of suprathermal electrons. Here we report on the solar-wind conditions as observed by these in-situ instruments during the first half of the collection phase of the mission, from December, 2001 to present.

Barraclough, B. L.↗

Precision Oxygen Isotope Measurements of Two C-Rich Hydrated Interplanetary Dust Particles

Introduction: Chondritic-smooth IDPs (Interplanetary Dust Particles) are low porosity objects whose mineralogy is dominated by aqueous alteration products such as Mg-rich phyllosilicates (smectite and serpentine group) and Mg-Fe carbonate minerals. Their hydrated mineralogy combined with low atmospheric entry velocities have been used to infer an origin largely from asteroidal sources. Spectroscopic studies show that the types and abundance of organic matter in CS IDPs is similar to that in CP IDPs. Although CS IDPs show broad similarities to primitive carbonaceous chondrites, only a few particles have been directly linked to specific meteorite groups such as CM and CI chondrites based on the presence of diagnostic minerals. Many CS IDPs however, have carbon contents that greatly exceed that of known meteorite groups suggesting that they either may derive from comets or represent samples of more primitive parent bodies than do meteorites. It is now recognized that many large, dark primitive asteroids in the outer main belt, as well as some trans-Neptunian objects, show spectroscopic evidence for aqueous alteration products on their surfaces. Some CS IDPs exhibit large bulk D enrichments similar to those observed in the cometary CP IDPs. While hydrated minerals in comets have not been unambiguously identified to date, the presence of the smectite group mineral nontronite has been inferred from infrared spectra obtained from the ejecta from comet 9P/Tempel 1 during the Deep Impact mission. Recent observations of low temperature sulfide minerals in Stardust mission samples suggest that limited aqueous activity occurred on comet Wild-2. All of these observations, taken together, suggest that the high-carbon hydrated IDPs are abundant and important samples of primitive solar system objects not represented in meteorite collections. Oxygen isotopic compositions of chondrites reflect mixing between a 16O-rich reservoir and a 17O,18O-rich reservoir produced via mass-independent fractionation. The composition of the 16O-rich reservoir is well constrained but material representing the 17O,18O-rich end-member is rare. Self-shielding models predict that cometary water, presumed to represent this reservoir, should be enriched in 17O and 18O by greater than 200 per mille. The high-carbon hydrated IDPs may be among the best materials available to search for preserved "cometary" H2O signatures. In order to better understand the origin and evolution of these particles, we have obtained 10 hydrated interplanetary dust particles for coordinated mineralogical, isotopic and organic analyses. We have previously reported the results of mineralogical and O isotopic measurements of two hydrated IDPs; here we present results of O isotopic measurements of three additional IDPs. Samples and Methods: Three interplanetary dust particles (L2079C35, L2083D46 and L2083E46) were embedded in S and partially ultramicrotomed into approximately 70 nanometer sections for analysis via transmission electron microscopy (TEM). The remainders of the unsliced particles were removed from S and pressed into high purity Au foil that was cleaned with HF acid and annealed at 800 degrees Centigrade. The pressed IDPs were analyzed via electron microprobe analysis (EPMA) for quantitative bulk chemical analysis. After EPMA analysis, the IDPs were subjected to precision O isotope analysis with the UCLA Cameca IMS-1270 ion probe. A 20 kiloelectronvolt, 0.5 nanoangstrom Cs+ primary beam of approximately 15 micrometers diameter was used for each measurement. Small particles of San Carlos olivine and Burma spinel were pressed into the Au foil for use as standards to correct for instrumental mass fractionation. The detection system was configured for multicollection, with 16O measured on a Faraday cup, and 17O and 18O measured on electron multipliers (EMs). Individual analyses consisted of 15 cycles of 10 seconds per cycle. Additionally, two microtome thin sections were measured for H isotopic compositions with the JSC NanoSIMS 50L ion probe. An 8 picoangstrom, 16 kiloelectronvolt Cs plus primary beam was used. Measurements consisted of H, C, 12C, 16O, and 18O collected with EMs in multicollection. Terrestrial biotite and kerogen were used for isotopic standards. A significant challenge in O isotope measurement of hydrated minerals is the interference from 16OH at mass 17O. We ensured that the 17O and 16OH peaks were fully resolved by using a mass resolution of greater than 7000 and by careful analyses of San Carlos olivine, Burma spinel and chlorite hydrated mineral standards. The hydride was further suppressed with a cold finger attached to an LN2 dewar to trap volatiles in the sample chamber. All sputtered ions were counted (i.e. presputtering was not used); after applying background, yield and deadtime corrections, we performed a change-point analysis on our data via R in order to determine when the sample reached sputtering equilibrium; data points collected prior to the change point were excluded. Change-point analysis was also used to determine whether the IDP had completely sputtered. Results: Mineralogy. IDPs C35 and E46 exhibited hydrated mineralogies, Fe-Ni sulfide grains, nanoglobules and occasional enstatite grains distributed throughout a fine-grained Mg-Fe saponite matrix. C35 also contained breunnerite (Mg,Fe)CO3; solar flare tracks were observed in enstatite, indicating minimal atmospheric entry heating. The mineralogy of D46 is dominated by a large FeS grain with a minor component of adhering silicate material. D46 was strongly heated during atmorpheric entry as evidenced by a well-developed magnetite rim. EPMA analyses show that both C35 and E46 have high carbon contents of 20 weight percentage (approximately 6X CI). D46 contains approximately 6 wt.weight percentage C. A significant amount of the carbon is present as carbon nanoglobules. Results: Hydrogen isotopes: Although the bulk delta D values of both sections of L2079C35 were within error of SMOW (minus 33 plus or minus 19 per mille, 1 plus or minus 14 per mille 1 sigma), several delta D-rich hotspots were also identified, reaching 2000 per mille. As shown in Fig. 1, these hotspots are clearly associated with discrete carbonaceous inclusions that are akin to nanoglobules found in many meteorites and other IDPs. Oxygen Isotopes. Results of the oxygen isotope measurements are shown in Figure 1. The oxygen isotope composition for L2079C35 was delta 18O equals plus11.6 plus or minus 1.9per mille, delta 17O equals plus 7.9 plus or minus 1.9per mille (2 standard errors). The oxygen isotope composition for L2083D46 was delta 18O equals minus 8.1 plus or minus 1.9 per mille, delta 17O equals minus 6.4 plus or minus 3.1 per mille (2 standard errors). The oxygen isotope composition for L2083E46 was delta 18O equals plus 12.0 plus or minus 1.9 per mille, delta 17O equals plus 9.2 plus or minus 2.0 per mille (2 standard errors). Discussion: Despite mineralogical similarities to highly aqueously altered carbonaceous chondrites, the hydrated IDPs we analyzed have oxygen isotopic compositions that are distinct from matrix materials in the CI, CM, and CR chondrites. The IDPs plot along the Young-Russell line, with delta 17O values for C35 and E46 suggestive of interaction with a 16O-poor reservoir. However, we have thus far not observed evidence of extreme 16O-poor reservoirs expected from self-shielding models and observed in Acfer 094 simplectite. The high carbon contents of the IDPs also set them apart from known meteoritic samples. The lack of atmospheric entry heating effects are consistent with low encounter velocities and suggest either an asteroidal source, or a low inclination, low eccentricity cometary origin. Conclusions: The unusual oxygen isotopic compositions, high carbon contents, and the abundance of Drich nanoglobules, together, suggest that the high-carbon, hydrated IDPs are derived from a primitive source that is not yet represented in meteorite collections.

Snead, C. J.↗

Isotopic and chemical investigations on Angra dos Reis

Isotope ratios and chemical abundance measurements for a variety of elements are reported for total meteorite and mineral separates of the Angra dos Reis achondrite. U-Pb, Th-Pb, and Pb-Pb ages are concordant at 4.54 eons for the total meteorite and for high-purity whitlockite, which indicates that Angra dos Reis is an early planetary differentiate that has not been disturbed for these systems since 4.54 eons ago. The implications of different ratios of Sr-87 and Sr-86 found in different components are discussed. Xe isotopic measurements show that Pu-244 was enriched in the whitlockite relative to the pyroxene by a factor of about 18. Chemical enrichment factors between the whitlockite and the fassaitic pyroxene in Angra dos Reis are presented

Wasserburg, G. J.↗

The Genesis Solar Wind Collection Mission: Current Status

The NASA Genesis spacecraft was launched August 8, 2001 on a mission to collect samples of solar wind for greater than or equal to 2 years and then return them to Earth in 2004. Detailed analyses of the solar wind ions implanted into high-purity collection substrates will subsequently be carried out in earth-based laboratories using various mass spectrometry techniques. These analyses are expected to determine key isotopic ratios and elemental abundances in the solar wind and, by extension, in the solar photosphere. Further, the photospheric composition is thought to be representative of the solar nebula with a few exceptions so that the Genesis mission will provide a baseline for the average solar nebula composition with which to compare present-day compositions of planets, meteorites, and asteroids. The implications of the solar oxygen isotopic composition have been discussed. A list of other isotopic and elemental measurement objectives, and some of the rationale behind them, is given.

Barraclough, B. L.↗

Contamination, Transportation or Transmutation in LENR Material Analyses

LENR experiments using various loading and triggering mechanisms rely on a variety of elemental and isotopic assays to determine LENR effects. These assays include optical microscopy, Scanning Electron Microscopy with Energy Dispersive X-Ray Analysis (SEM/EDX), X-Ray Photoelectron Spectroscopy (XPS) and Transmission Electron Microscopy (TEM). All of these methods observe the surface of a material. By dissolving or vaporizing the sample, Inductively Coupled Plasma Optical Element Spectroscopy (ICP-OES) can determine elemental composition (ppb) or with mass spectroscopy, isotopes (ICP/MS). One can use a focused ion beam (FIB) to cut open a sample and observe the “cut” with either SEM/EDX, or Time-of-Flight Secondary Ion Mass Spectroscopy (TOF-SIMS). High Purity Gamma Ray Spectroscopy (HPGe) and alpha/ beta Liquid Scintillator spectroscopy can be used. We’ve employed these assay methods in our NASA GRC research under both the Advanced Energy Conversion and Lattice Confinement Fusion Projects. However, there are limitations associated with each of these methods ranging from handling contamination, instrumental limitations including sensitivity and field of view, and sample preparation.

Low Energy Nuclear Reactions↗

Noble gases in presolar diamonds I: Three distinct components and their implications for diamond origins

High-purity separates of presolar diamond were prepared from 14 primitive chondrites from 7 compositional groups. Their noble gases were measured using stepped pyrolysis. Three distinct noble gas components are present in diamonds, HL, P3, and P6, each of which is found to consist of five noble gases. P3, released between 200 C and 900 C, has a 'planetary' elemental abundance pattern and roughly 'normal' isotopic ratios. HL, consisting of isotopically anomalous Xe-HL and Kr-H, Ar with high Ar-38/Ar-36, and most of the gas making up Ne-A2 and He-A, is released between 1100 C and 1600 C. HL has 'planetary' elemental ratios, except that it has much more He and Ne than other known 'planetary' components. HL gases are carried in the bulk diamonds, not in some trace phase. P6 has a slightly higher median release temperature than HL and is not cleanly separated from HL by stepped pyrolysis. Our data suggest that P6 has roughly 'normal' isotopic compositions and 'planetary' elemental ratios. Both P3 and P6 seem to be isotopically distinct from P1, the dominant 'planetary' noble-gas component in primitive chondrites. Release characteristics suggest that HL and P6 are sited in different carriers within the diamond fractions, while P3 may be sited near the surfaces of the diamonds. We find no evidence of separability of Xe-H and Xe-L or other isotopic variations in the HL component. However, because approximately 10(exp 10) diamonds are required to measure a Xe composition, a lack of isotopic variability does not constrain diamonds to come from a single source. In fact, the high abundance of diamonds in primitive chondrites and the presence of at least three distinct noble-gas components strongly suggest that diamonds originated in many sources. Relative abundances of noble-gas components in diamonds correlate with degree of thermal processing, indicating that all meteorites sampled essentially the same mixture of diamonds. That mixture was probably inherited from the Sun's parent molecular cloud.

Huss, Gary R.↗

Microscale determination of the spectral characteristics and carbon-isotopic compositions of porphyrins

Molar extinction coefficients for band III of Ni porphyrins are calculated from results of spectrophotometric and manometric analyses of individual etioporphyrins, DPEP, cyclic, and diDPEP porphyrins known to initially be pure from mass spectrometry, 1H NMR, and analytical HPLC studies. A method for determining carbon-isotopic compositions and purity of micromolar quantities of individual porphyrins using combined spectrophotometric and manometric techniques is presented.

Non-NASA Center↗

Osiris-REx Spacecraft Current Status and Forward Plans

The NASA New Frontiers OSIRIS-REx spacecraft executed a flawless launch on September 8, 2016 to begin its 23-month journey to near-Earth asteroid (101955). The primary objective of the OSIRIS-REx mission is to collect and return to Earth a pristine sample of regolith from the asteroid surface. The sampling event will occur after a two-year period of remote sensing that will ensure a high probability of successful sampling of a region on the asteroid surface having high science value and within well-defined geological context. The OSIRIS-REx instrument payload includes three high-resolution cameras (OCAMS), a visible and near-infrared spectrometer (OVIRS), a thermal imaging spectrometer (OTES), an X-ray imaging spectrometer (REXIS), and a laser altimeter (OLA). As the spacecraft follows its nominal outbound-cruise trajectory, the propulsion, power, communications, and science instruments have undergone basic functional tests, with no major issues. Outbound cruise science investigations include a search for Earth Trojan asteroids as the spacecraft approaches the Sun-Earth L4 Lagrangian point in February 2017. Additional instrument checkouts and calibrations will be carried out during the Earth gravity assist maneuver in September 2017. During the Earth-moon flyby, visual and spectral images will be acquired to validate instrument command sequences planned for Bennu remote sensing. The asteroid Bennu remote sensing campaign will yield high resolution maps of the temperature and thermal inertia, distributions of major minerals and concentrations of organic matter across the asteroid surface. A high resolution 3d shape model including local surface slopes and a high-resolution gravity field will also be determined. Together, these data will be used to generate four separate maps that will be used to select the sampling site(s). The Safety map will identify hazardous and safe operational regions on the asteroid surface. The Deliverability map will quantify the accuracy with which the navigation team can deliver the spacecraft to and from specific sites on the asteroid surface. The Sampleability map quantifies the regolith properties, providing an estimation of how much material would be sampled at different points on the surface. The final Science Value map synthesizes the chemical, mineralogical, and geological, observations to identify the areas of the asteroid surface with the highest science value. Here, priority is given to organic, water-rich regions that have been minimally altered by surface processes. Asteroid surface samples will be acquired with a touch-and-go sample acquisition system (TAGSAM) that uses high purity pressurized N2 gas to mobilize regolith into a stainless steel canister. Although the mission requirement is to collect at least 60 g of material, tests of the TAGSAM routinely exceeded 300 g of simulant in micro-gravity tests. After acquiring the sample, the spacecraft will depart Bennu in 2021 to begin its return journey, with the sample return capsule landing at the Utah Test and Training Range on September 23, 2023. The OSIRIS-REx science team will carry out a series of detailed chemical, mineralogical, isotopic, and spectral studies that will be used to determine the origin and history of Bennu and to relate high spatial resolution sample studies to the global geological context from remote sensing. The outline of the sample analysis plan is described in a companion abstract.

Messenger, Scott↗