Search NASA⌕ Search

SEARCH · Search NASA

Results for “high purity isotopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

SRF Resonators for a bi-directional Energy Ramping Upgrade of the Isotope Production Facility Beamline at LANL

The LANL Isotope Production Facility (IPF) is one of the two high-current proton linear accelerators operated under the auspices of the DOE Office of Nuclear Physics Isotope Development and Production for Research Applications Program. The IPF beamline operates with a fixed 100-MeV energy proton beam, diverted from the LANSCE accelerator and guided towards the isotope production target station. The fixed beam energy limits the number of isotopes that can be produced at IPF, and adversely affects the purity of isotopes produced at non-optimal energies. In particular, the IPF program is receiving increasing numbers of requests for high purity isotopes such as Np-236 (national security applications) and Re-186 (medical therapy). These are typically produced via (p,n) and (p,2n) nuclear reactions, requiring very tight control of the incident energies on the production targets to ensure an end product with a high radionuclidic purity. It is well known that this level of energy control cannot be achieved when a 100 MeV beam of mono-energetic protons is degraded to the required energies, typically below 30 MeV, as too much energy spread is acquired. Operating the IPF beamline at lower, mono-energetic beam energies such as at 40 MeV will allow the required tight energy control in target assemblies to ensure a high purity product. In addition, NP has requested a LANL/BNL/ORNL collaboration focus on establishing a national large-scale production capability for the therapy isotope Ac-225. Recent nuclear cross section measurements done at LANL show that due to a steep rise in production cross section towards higher proton energies (See Figure 2), proton beams at energies substantially greater than 100 MeV will be highly beneficial for Ac-225 production [AC255]. Such higher-energy beams cannot be delivered to IPF at present. Lower-energy beams (70 MeV and 40 MeV) can be delivered but only in sole-use mode; all other LANSCE users must be offline during 70 MeV or 40 MeV operation.

07 ISOTOPE AND RADIATION SOURCES↗

Combination of DGA and LN Columns: A Versatile Option for Isotope Production and Purification at Oak Ridge National Laboratory

The chromatographic resins DGA and LN have been used sequentially to separate curium, californium, plutonium, and various fission products (FPs) to obtain products with a pure radioisotope or a radioelement with high isotopic purity. This 2-step combination of resins has found applications in the 252 Cf and 238 Pu campaigns performed at Oak Ridge National Laboratory. Experiments have been carried out in glove boxes, shielded caves, and hot cells, demonstrating that these resins are adequate and maintain their performance in highly radiolytic environments. We find that using these resins has led to the recovery of curium highly enriched (>95%) in 248 Cm, the clean separation of 251 Cf for the superheavy element research, and the recovery of 147 Pm from the FP stream obtained during the 238 Pu production campaign while demonstrating that the raffinate post DGA is essentially free of transuranic elements.

07 ISOTOPE AND RADIATION SOURCES↗

An approach to separating Pu, U, and Ti from high-purity graphite for isotopic analysis by MC-ICP-MS

Information about elemental and isotopic systematics of ultra-trace level actinides (e.g. U and Pu) and main group elements (e.g. Ti) present within nuclear grade graphite is vital to the nuclear community for improved reactor operation and security. In support of this, extensive effort has been placed on improving analysis methods (i.e., inductively coupled plasma-mass spectrometry). However, significantly less effort has been devoted to the optimization of chemical separation methods. Within the separation community, commercially available Eichrom™ resins are often employed, as their elution characteristics for various elements have been well studied, but the direct optimization of actinides and trace metal separations from a single sample have not been widely investigated. Here, methods using various Eichrom pre-packed cartridges were explored to achieve separation of ultra-trace levels of U, Pu, and Ti from a variety of graphite samples. Once the validity of the combined separation scheme was established using certified reference materials, the method was applied to historic, unirradiated and irradiated, graphite samples. For all samples investigated, precise isotope ratio measurements for the titanium isotope systems were made.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Proof-of-concept studies of novel protocols for producing highly pure 48 V from a 48 Cr/ 48 V generator

Here, the quest to improve the quality of nuclear data, such as half-lives, transition yields, and reaction cross-sections, is a shared endeavor among various areas of nuclear science. 48 V is a vanadium isotope for which experimental data on neutron reaction cross-sections is needed. However, traditional isotope production techniques cannot produce 48 V with high enough isotopic purity for some of these measurements. “Isotope harvesting” at the Facility for Rare Isotope Beams (FRIB) is a new isotope production technique that could potentially yield 48 V with the necessary purity for such studies. In this case, 48Cr would be collected and allowed to generate 48 V that can be separated from undecayed 48 Cr to yield highly pure 48 V. Thus, any protocol for producing pure 48 V via isotope harvesting would involve utilizing a separation technique that can effectively separate 48 Cr and 48 V. In this study, the radiotracers 51 Cr and 48 V were used to develop possible radiochemical separation methodologies, which can be translated to obtain high purity 48 V via this novel isotope production method. The developed protocols utilize either ion exchange or extraction chromatographic resins. Separations of 51 Cr and 48 V with AG 1-X8 anion exchange resin respectively resulted in recoveries of 95.6(26)% and 96.2(12)% with radionuclidic purities of 92(2)% and 99(1)%. An even more effective Cr and V separation was obtained with an extraction chromatographic resin (TRU resin) and 10 M HNO 3 loading solution. Here, 51 Cr and 48 V respectively had recoveries of 94.1(28)% and 96.2(13)% with high radionuclidic purities (100(2)% and 100(1)%) in small volumes (8.81(8) mL and 5.39(16) mL). This study suggests that, to maximize the yield and isotopic purity of 48 V, the best production protocol would involve utilizing two separations with TRU resin and 10 M HNO 3 to isolate 48 Cr and purify the generated 48 V.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

System, emanation generator, and process for production of high-purity therapeutic radioisotopes

An isotope production system, emanation generator, and process are disclosed for production of high-purity radioisotopes. In one implementation example, high-purity Pb-212 and/or Bi-212 isotopes are produced suitable for therapeutic applications. In one embodiment the process includes transporting gaseous radon-220 from a radium-224 bearing generator which provides gas-phase separation of the Rn-220 from the Ra-224 in the generator. Subsequent decay of the captured Rn-220 accumulates high-purity Pb-212 and/or Bi-212 isotopes suitable for direct therapeutic applications. Other high-purity product isotopes may also be prepared.

O'Hara, Matthew J.↗

Production of Radioisotopes of Scandium for Imaging and Therapy (Final Report)

The theranostic approach is a powerful technique that enables scientists and physicians to diagnose and treat diseases using the same targeting moiety labeled with radionuclides for imaging and therapy. A challenge behind synthesizing and evaluating these theranostic radiopharmaceuticals lies in the production of suitable radionuclides. This study aimed to investigate the production of high radionuclidic purity 43 Sc from enriched [ 46 Ti]TiO 2 for Positron Emission Tomography (PET) and 47 Sc from enriched [ 50 Ti]TiO 2 for targeted radiotherapy, as well as establish a target recycling technique for continued production of these radionuclides. Methods: Targets were prepared with 100 mg of either enriched [ 46 Ti]TiO 2 or [ 50 Ti]TiO 2 , pressed into pellets, and placed into Ta target holders with a 0.127 mm natTi cover foil. The 46 Ti targets were bombarded with 18 MeV protons at 20 µA for 1.5 h, while 50Ti targets were bombarded with 24 MeV protons at 20 µA for 4 or 8 h. The radioscandium nuclides were purified using branched N, N, N’, N’ -tetra-2-ethylhexyldiglycolamide (DGA) resin. The titanium targets were recycled by precipitating the dissolved Ti collected from the column effluent and wash streams, pH adjustment, vacuum filtration, and then drying the solid at 250 °C prior to reforming the target for the subsequent bombardment. The apparent molar activity of the isolated radioscandiums was analyzed by titration with 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA). The relative imaging performance of 18 F, 43 Sc, and 68 Ga were analyzed with PET images acquired with 30-min static scans. Results: The average radioscandium recovery for 43Sc was 91.7 ± 7.4 %, with a radionuclidic purity of 98.8 %. The average recovery of 47Sc was 89.9 ± 3.9 %, with a radionuclidic purity of 90.8%. The average recovery of enriched TiO2 was 96 ± 4.0 %. The highest apparent molar activity for [43Sc]Sc-DOTA was 23.2 GBq/µmol and 3.39 GBq/µmol for [ 47 Sc]Sc-DOTA. The order of PET resolution from highest to lowest was 18 F > 43 Sc > 68 Ga. Conclusions: This work demonstrates the feasibility of using enriched recycled [ 46 Ti]TiO 2 and [ 50 Ti]TiO 2 targets for the production of the 43 Sc and 47 Sc theranostic isotope pair in high purity.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Syntheses and characterization of isotopically labeled 1,3,5-triamino-2,4,6-trinitrobenzene (TATB)

Synthesis and characterization of chemical analogues of TATB, where specific atoms in the structure have been isotopically substituted, are reported. 15 N, 2 H, and 18 O have replaced the naturally occurring isotope distributions in the amino and/or the nitro attendant sites and 13 C has replaced the carbon in the ring structure. A modified wet-amination method was used to produce the analogues, and the isotopic replacements were performed by selective choice of labeled precursors. Four 15 N-labeled compounds (N replaced in the amino and nitro positions), two deuterium-labeled compounds (hydrogens replaced on the amino groups), and one 13 C-labeled compound (C in the ring substituted) were synthesized of high isotopic and chemical purity. One partially labeled 18 O-labeled compound (O in the nitro position) was a result of incomplete labeling due to exchange reactions during synthesis. The compounds were characterized by various spectroscopic methods – mass spectrometry (MS), solid-state nuclear magnetic resonance (SS-NMR), infrared (FTIR), powder x-ray diffraction (PXRD), and differential scanning calorimetry (DSC), depending upon the substitution. In conclusion, these compounds have been critical to the efforts in understanding the decomposition pathways of TATB when exposed to abnormal thermal environments.

36 MATERIALS SCIENCE↗

Results of the LEGEND-200 experiment in the search for $0νββ$ decay

The LEGEND experiment is looking for the extremely rare neutrinoless double beta (0νββ) decay of 76 Ge using isotopically-enriched high-purity germanium (HPGe) detectors. The detection of this process would imply that the neutrino is a Majorana particle and the total lepton number would not be conserved, which could be related to the cosmological asymmetry between matter and antimatter through leptogenesis. The long-term goal of the collaboration is LEGEND-1000: a 1-ton detector array planned to run for 10 years, with a projected half-life sensitivity exceeding 10 28 years, fully covering the inverted neutrino mass hierarchy. A first search for the 0νββ decay has been carried out by LEGEND-200 building on the experience gained from GERDA and the MAJORANA DEMONSTRATOR. The experiment has been collecting physics data for a year at the Gran Sasso National Laboratory in Italy with 140 kg of HPGe detectors. With a total exposure of 61 kg yr, LEGEND-200 has achieved a background index of $5_{−2}^{+3}$ × 10 −4 counts/(keV kg yr) in the 0νββ decay signal region from the highest performing detectors. After combining the results from GERDA, the MAJORANA Demonstrator and LEGEND-200, an exclusion sensitivity > 2.8 × 10 26 yr has been obtained at 90% confidence level for the 0νββ decay half-life, with no evidence for a signal. A new observed lower limit of $T_{1/2}^{0v} >$ 1.9 × 10 26 yr at 90% confidence level has been established.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Heavy ion beam physics at Facility for Rare Isotope Beams

The Facility for Rare Isotope Beams (FRIB) will be the world's premier rare-isotope beam facility. Experiments with the majority (~80%) of the isotope predicted to exist will become available. The FRIB facility is based on a superconducting (SC) heavy ion linac with output energy above 200 MeV/u for any ions at beam power of 400 kW. FRIB includes a target facility for in-flight production of rare isotopes. A three-stage fragment separator will be used to prepare fast rare isotope beams with high-purity for nuclear physics experiments. The installation work of the accelerator and experimental systems is approaching completion and multi-stage beam commissioning activities started in summer 2017 with expected project completion in early 2022. In conclusion, the commencement of operation for users' experiments is planned immediately following the project completion.

43 PARTICLE ACCELERATORS↗

High-Precision Mapping of Diamond Crystal Strain Using Quantum Interferometry

Crystal-strain variation imposes significant limitations on many quantum sensing and information applications for solid-state defect qubits in diamond. Thus, the precision measurement and control of diamond crystal strain is a key challenge. Here, we report diamond strain measurements with a unique set of capabilities, including micron-scale spatial resolution, a millimeter-scale field of view, and a 2-order-of-magnitude improvement in volume-normalized sensitivity over previous work, reaching 5(2)×10 -8 /√Hzμm -3 (with spin-strain coupling coefficients representing the dominant systematic uncertainty). We use strain-sensitive spin-state interferometry on ensembles of nitrogen-vacancy (N-V) color centers in single-crystal bulk diamond with low strain gradients. This quantum interferometry technique provides insensitivity to magnetic-field inhomogeneity from the electronic and nuclear spin bath, thereby enabling long N-V–ensemble electronic spin dephasing times and enhanced strain sensitivity, as well as broadening the potential applications of the technique beyond isotopically enriched or high-purity diamond. We demonstrate the strain-sensitive measurement protocol first on a confocal scanning laser microscope, providing quantitative measurement of sensitivity as well as three-dimensional strain mapping; and second on a wide-field-imaging quantum diamond microscope. Our strain-microscopy technique enables fast, sensitive characterization for diamond material engineering and nanofabrication; as well as diamond-based sensing of strains applied externally, as in diamond anvil cells or embedded diamond stress sensors, or internally, as by crystal damage due to particle-induced nuclear recoils.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gamma spectrometry uranium isotopic analysis rodeo: Summary of GADRAS results

This report summarizes GADRAS methods and gamma spectrometry rodeo uranium isotopic analysis results for high energy resolution H3D M400 cadmium zinc telluride (CZT) and ORTEC Micro Detective high-purity germanium (HPGe) spectra of uranium isotopic standards collected at Oak Ridge National Laboratory (ORNL) and Lawrence Livermore National Laboratory (LLNL) over a two-year measurement campaign. During the campaign, measurements were performed with the detectors unshielded, side shielded, and collimated. In addition, measurements of the uranium isotopic standards were performed unshielded and shielded.

07 ISOTOPE AND RADIATION SOURCES↗

Improved Cumulative Fission Yield Measurements with Fission Spectrum Neutrons on 238U

Two isotopically-characterized targets of high-purity (99.961±0.002%) 238U metal and a neutron dosimetry package were exposed to a pulsed neutron irradiation using the Godiva IV critical assembly at the National Criticality Experiments Research Center to measure the integral fission product yields produced in a Watt fission neutron-energy spectrum. Following irradiation, the fissioned targets were counted with two broad energy germanium detectors. Estimates of the total fissions for each target were made using measurements of well-known fission products. The total number of fissions in each target were then used to measure the fission yields of 33 fission products, 18 of which are published as new measurements. Twelve of the 18 isotopes were in agreement with ENDF/B- VIII.0 using the zeta test and treating ENDF/B-VIII.0 as the true mean: 84mBr, 93Y, 94Y, 104Tc, 134I, 135I, 138Xe, 141Ba, 142Ba, 142La, 146Ce, and 149Nd. The ENDF/B-VIII.0 fission yield for 139Ba was only slightly outside of 1-s relative to the uncertainty measured in this work. Uncertainties for 5 fission product yields were markedly improved over those reported in ENDF/B-VIII.0: 128Sn, 129Sb, 130gSb, 131mTe, and 133I. The fission yields measured for 128Sn, 131mTe, and 133I were in good agreement with the ENDF/B-VIII.0 predicted fission yields. However, fission yields measurements of the isotopes 129Sb, and 130gSb deviated from the ENDF/B-VIII.0 value. Both of these isotopes reside near the doubly magic nuclear shell closures of 50 protons and 82 neutrons. These fission yields may be suppressed because of the odd-odd nuclear structure of 130gSb and the odd-even structure of 129Sb and isomer splitting. Comparisons to other recent work and a brief review with citations are included to support this conclusion.

Fission Yields↗

Surrogate isotope-containing materials for emergency response training and Methods of formation and dispersal

Surrogate materials are in the form of solid particles that include surrogate isotopes, namely, short-lived isotopes selected and formed to serve as surrogates for the radioactive materials of a nuclear fallout without including isotopes that are, or that decay to, biologically or environmentally deleterious and persistent isotopes. The surrogate material may be formed using high-purity reactant material and irradiation and separation techniques that enable tailoring of the isotopes and ratios thereof included in the surrogate material, and the surrogate material may be dispersed, e.g., in a training environment, in solid form.

Carney, Kevin P.↗

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas Stopper Developments for Improved Purity and Intensity of Low-Energy, Rare Isotope Ion Beams (Final Technical Report)

This final technical report summarizes the work of the Michigan State University (MSU) team supported by grant # DE-SC0021423 awarded by the Office of Nuclear Physics, Department of Energy. Objectives: The successful fulfillment of the FRIB science mission hinges on ensuring the availability of fast, stopped, and reaccelerated beams consisting of rare isotopes. This project's research and development focus was dedicated to supporting the advancement and creation of a cutting-edge linear gas stopper. The primary aim is to efficiently convert the high-intensity fast beams of rare isotopes provided by FRIB into high-quality, low-energy beams. These beams are essential for conducting stopped beam experiments or for subsequent reacceleration. The overarching goal is to advance technology, aiming to increase the beam rate capability of the linear gas stopper for medium-to-heavy-mass rare isotopes by more than tenfold compared to the currently most effective gas stopper in operation, and to improve the purity of the delivered beams. Project Description: The existing technology employed in gas stopping devices designed for low-energy, rare-isotope beams presents limitations in both the purity of extracted beams and the intensities of injected beams. These limitations are incompatible with the requirements of the recently commissioned rare isotope beam facility, FRIB. Our research and development efforts, aligned with the previously outlined objectives, focused on addressing the most critical aspects for enhancing beam-rate capability and purity. Specifically, advanced particle-in-cell simulations were developed and integrated into a simulation pipeline to explore the efficacy of multi-layer RF carpets on increasing ion transport efficiency with high incoming beam rates that generate space charge fields which can limit it. We also explored the possibility of using a collision-induced-dissociation (CID) gas cell to break up molecular contaminant ions that are generated during the stopping process. A prototype CID gas cell was constructed and tested with beams from an offline ion source, validating the concept with the successful demonstration of breaking of molecular ions. The outcome of this research enabled the formulation a conceptual design for a next-generation linear gas stopping device specifically tailored for FRIB. This device is envisioned to deliver rare-isotope-ion beams at a rate of 10 8 particles per second or higher, accompanied by advancements in purity. Methods employed: This project leverages advancements in technologies initially designed for the Advanced Cryogenic Gas Stopper (ACGS), the current state-of-the-art linear gas stopper, through the use of new simulations and beam purification via collision-induced-dissociation. The methods include: 1. Development of a prototype low-energy, low-pressure CID gas stopper. This prototype features a thin, approximately 20 nm, Si 3 N 4 entrance window designed for dissociating stable and rare-isotope molecular ions. The goal is to enhance beam purification and overall efficiency. 2. Creation of Particle-in-cell (PIC) simulations to assess the advantages of multi-layer RF carpets and multi-point extraction for ion transport efficiency. These simulations rely on the 3DCylPIC package, specifically designed for studying devices of this nature. The goal is to quantify and mitigate ion transport losses due to space charge generated in the stopping process of large numbers of ions. 3. Perform ion transport simulations across an RF carpet using an 8-phase travelling wave and evaluate its performance. Compared to the 4-phase RF carpets used in ACGS, the 8-phase carpets will double the wavelength of the generated traveling wave allowing for larger maximum RF amplitudes that could result in improved ion transport efficiency for high-intensity incoming beams when large space charge fields are present. Impact: Tackling the primary challenges associated with transforming high-energy projectile fragment beams into low-energy beams—specifically, addressing efficiency and purity—holds significant promise for advancing FRIB science. This advancement will particularly impact precision mass measurements, laser spectroscopy of short-lived nuclei, and studies in astrophysics and nuclear reactions using reaccelerated beams. These domains play a crucial role in addressing key questions outlined in the 2023 NSAC long-range plan, spanning nuclear structure, nuclear astrophysics, and fundamental symmetries. Additionally, they contribute to addressing 10 out of the 17 benchmarks identified by the NRC RISAC. The development of a next-generation gas stopping device capable of delivering low-energy, rare-isotope beams at a rate of 10 8 particles per second, or more, with high purity holds the potential to unlock experiments that would otherwise be unfeasible. Furthermore, it is expected to reduce the time required for experiments at FRIB, thereby maximizing scientific output. The research and development activities performed as part of this project bolstered essential competencies at FRIB in beam physics and ion source technologies, provided valuable training opportunities for junior scientists.

43 PARTICLE ACCELERATORS↗

Characterization of the First Prototype of the L1K65n Differential-Output Charge-Sensitive Preamplifier ASIC for High-Performance, Low-Background HPGe Detector Readout

Next-generation neutrinoless double-beta (0νββ) decay searches require a large detector/isotope mass and very low radioactive backgrounds. The upcoming LEGEND-1000 experiment (Large Enriched Germanium Experiment for Neutrinoless double-beta Decay) constitute a ton-scale array of several hundred high-purity germanium (HPGe) detectors enriched in 76Ge, the isotope of interest. It aims to reach a sensitivity beyond 10 28 years on the 0νββ decay half-life of 76Ge, necessitating an order of magnitude reduction in background with respect to the state of the art. This will require the implementation of a dedicated application specific integrated circuit (ASIC) preamplifier that will significantly lower background contribution compared to the conventional low-mass front end (LMFE) employed in the Majorana Demonstrator and LEGEND-200 experiments while maintaining or improving energy resolution and other performance parameters. Features include a high (9 MeV) dynamic range with noise low enough to achieve a trigger threshold of <1 keV, a single power supply to reduce background-inducing cabling, and a differential output to maintain signal integrity over several meters of transmission line. The chip would be optimized to operate in liquid argon (87 K) and be able to do so reliably for ten years. Following on from an earlier 180-nm prototype, we have developed a differential-output charge-sensitive preamplifier ASIC fabricated in a 65-nm process, 1×2 mm in size, that addresses these needs. Here, we present recent results from the successful testing and characterization of the first version of this device.

ASIC↗

Measurement of Plutonium Ratios for CRM 137A Recertification

This report documents the analytical methodologies used by the Chemical and Isotopics Mass Spectrometry (CIMS) Group at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) for plutonium isotopic ratio characterizations on purified ~1 mg units prepared by Lawrence Livermore National Laboratory (LLNL) from a mother solution created from an existing 250 mg unit of certified reference material (CRM) 137. The analytical processes described are designed to maintain traceability of the final certified attributes and to eliminate sources of systematic bias for the measurements described. The measurands for certification are the plutonium isotope ratios: 238 Pu/ 239 Pu, 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu. The preparation and analytical process included the following activities: Preparation of reference materials to be used as calibrants to establish traceability to the SI unit of mass for the isotopic analyses and quality controls. For the plutonium isotopic analyses, CRM 128 (a CRM comprising equal atoms of 239 Pu and 242 Pu) was used as the primary calibrant; Each CRM 137A unit was reconstituted using dilute high-purity HNO3. From each, seven replicates were distributed for the isotopic characterizations by thermal ionization mass spectrometry (TIMS) using the total evaporation (TE) method for isotope ratio measurements and MC-ICP-MS using a dynamic peak hooping method for secondary isotope ratio measurements; Due to time delay in the analyses from the last purification of the original CRM 137 mother solution by LLNL, an aliquot of the three provided plutonium units was purified using Eichrom TEVA separation methods to remove americium in-growth and uranium impurities; Minimally corrected data were reported from each analysis using reporting templates provided by the New Brunswick Laboratory Program Office (NBL PO) for the specific methods used for isotopic measurements. In addition, a copy of the instrument exports, Excel templates for isotopic data corrections, and the uncertainty budgets completed with the GUM Workbench software package were submitted to NBL PO.

07 ISOTOPE AND RADIATION SOURCES↗