Search NASA⌕ Search

SEARCH · Search NASA

Results for “high solid loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Design and experimental results of a highly loaded, low solidity, jet flap rotor

The overall performance of a single-stage turbine with a low solidity jet flap rotor blade assembly was tested over a range of cavity pressure ratios, equivalent speeds, and expansion ratios. The rotor blades were designed with negative hub reaction and a mean-line axial chord solidity of 0.922. The results of the investigation are compared with the performance of a modified jet flap rotor blade which was designed to similar velocity diagrams but with a mean-section, axial chord solidity of 1.541. Both rotors were tested with the same stator.

Bettner, J. L.↗

Properties of silicon suspensions and slip-cast bodies

The effect of varying pH, sonication times, and solid loading of silicon powder suspensions on the properties of powder/water suspensions and on the resulting pore characteristics of slip-cast bodies was studied. Aqueous suspensions of ground an aged silicon powder (of 0.3 micron median Stokes diameter and containing 1.3 vol pct Fe2O3 powder) were prepared, with solids loading in the range of 30-56 vol pct, and were adjusted to varying pH values by addition of either HCl or NH4OH or NaOH. Suspension aliquots were sonicated for 0, 15, 30, or 60 min. Suspensions were characterized by zeta potentials, ionic strength, and viscosity. Pore characteristics of cast bodies were determined by mercury porosimetry. It was found that intermediate pH values (pH 7-9), long sonication (60 min), and high solid loadings (56 vol pct) produced samples with highest green densities and smallest median pore radius.

Sacks, M. D.↗

Two-dimensional cascade test of a highly loaded, low-solidity, tandem airfoil turbine rotor blade

A tip region section of a low-solidity tandem airfoil blade for a turbine rotor was tested in a two-dimensional cascade tunnel at solidities of 0.736 and 0.912. Blade surface static pressures and blade exit total and static pressure and flow angle were surveyed. Blade surface velocities, wake shapes, and kinetic energy losses were analyzed and compared with values for 1.852 solidity tandem airfoil blading.

Kline, J. F.↗

Characterization and Detailed Analysis of Regression Behavior for HTPB Solid Fuels Containing High Aluminum Loadings

NASA Marshall Space Flight Center's Materials and Processes Department, with support from the Propulsion Systems Department, has renewed the development and maintenance of a hybrid test bed for exposing ablative thermal protection materials to an environment similar to that seen in solid rocket motors (SRM). The Solid Fuel Torch (SFT), operated during the Space Shuttle program, utilized gaseous oxygen for oxidizer and an aluminized hydroxyl-terminated polybutadiene (HTPB) fuel grain to expose a converging section of phenolic material to a 400 psi, 2-phase flow combustion environment. The configuration allows for up to a 2 foot long, 5 inch diameter fuel grain cartridge. Wanting to now test rubber insulation materials with a turn-back feature to mimic the geometry of an aft dome being impinged by alumina particles, the throat area has now been increased by several times to afford flow similarity. Combined with the desire to maintain a higher operating pressure, the oxidizer flow rate is being increased by a factor of 10. Out of these changes has arisen the need to characterize the fuel/oxidizer combination in a higher mass flux condition than has been previously tested at MSFC, and at which the literature has little to no reporting as well. For (especially) metalized fuels, hybrid references have pointed out possible dependence of fuel regression rate on a number of variables: mass flux, G - oxidizer only (G0), or - total mass flux (Gtot), Length, L, Pressure, P, and Diameter, D.

Kibbey, Timothy P.↗

Wear characteristics of bonded solid film lubricant under high load condition

Wear properties of phenolic resin bonded molybdenum disulfide film lubricant were studied. In-vacuo journal bearing tests were performed to evaluate the wear-life of this film lubricant. The wear-life depends on substrate materials and on sliding velocity. Pretreated substrate surfaces were examined to reveal the reasons for these results. Additionally, investigations on film wear mechanisms were made.

Hiraoka, Naofumi↗

Analytical and Experimental Evaluation of the Heat Transfer Distribution over the Surfaces of Turbine Vanes

Three airfoil data sets were selected for use in evaluating currently available analytical models for predicting airfoil surface heat transfer distributions in a 2-D flow field. Two additional airfoils, representative of highly loaded, low solidity airfoils currently being designed, were selected for cascade testing at simulated engine conditions. Some 2-D analytical methods were examined and a version of the STAN5 boundary layer code was chosen for modification. The final form of the method utilized a time dependent, transonic inviscid cascade code coupled to a modified version of the STAN5 boundary layer code featuring zero order turbulence modeling. The boundary layer code is structured to accommodate a full spectrum of empirical correlations addressing the coupled influences of pressure gradient, airfoil curvature, and free-stream turbulence on airfoil surface heat transfer distribution and boundary layer transitional behavior. Comparison of pedictions made with the model to the data base indicates a significant improvement in predictive capability.

Hylton, L. D.↗

Measurements of heat transfer distribution over the surfaces of highly loaded turbine nozzle guide vanes

The results of an experimental study of aerodynamic (surface velocity) and heat transfer distributions over the surfaces of two different, highly loaded, low-solidity contemporary turbine vane designs are presented. The aerodynamic configurations of the two vanes were carefully selected to emphasize fundamental differences in the character of the solution surface pressure distributions and the consequent effect on surface heat transfer distributions. The experimental measurements were made in moderate-temperature, three-vane cascades under steady-state conditions. The principal independent parameters (Mach number, Reynolds number, turbulence intensity, and wall-to-gas temperature ratio) were varied over ranges consistent with actual engine operation, and the heat matrix was structured to provide an assessment of the independent influence of each parameter. These measurements are intended to serve as verification data for a parallel analytical code development effort. The results of this parallel effort are briefly reviewed, and the principal conclusions to date are summarized.

Nealy, D. A.↗

New Vapor/Mist Phase Lubricant Formulated

To meet the increased thermal stresses of future advanced aircraft engines, new lubricants will have to be developed to replace the currently used ester-based liquid lubricants. If a suitable conventional replacement cannot be found, a different lubrication method will have to be used. The conventional method circulates bulk lubricant (stored in a sump) through a lubricating system containing cooling and filtering elements. Solid lubricants have been studied as a replacement for bulk liquid lubricants, and have been found to provide reasonable lubrication for lightly loaded systems. Solid lubricants, however, have proved inadequate for highly loaded, high-speed applications. Vapor/mist phase lubrication (VMPL), on the other hand, may be a viable alternative. VMPL has been used successfully to lubricate high-temperature bearings or gears. It can be used as an emergency backup system or as the primary source of lubrication. With VMPL, minimal weight is added to the system and minimal debris is formed. It works over a wide temperature range.

Morales, Wilfredo↗

Recent advances in solid polymer electrolyte fuel cell technology with low platinum loading electrodes

High power density fuel cell systems for defense and civilian applications are being developed. Taking into consideration the main causes for efficiency losses (activation, mass transport and ohmic overpotentials) the only fuel cell systems capable of achieving high power densities are the ones with alkaline and solid polymer electrolyte. High power densities (0.8 W/sq cm at 0.8 V and 1 A/sq cm with H2 and O2 as reactants), were already used in NASA's Apollo and Space Shuttle flights as auxiliary power sources. Even higher power densities (4 W/sq cm - i.e., 8 A sq cm at 0.5 V) were reported by the USAF/International Fuel Cells in advanced versions of the alkaline system. High power densities (approximately 1 watt/sq cm) in solid polymer electrolyte fuel cells with ten times lower platinum loading in the electrodes (i.e., 0.4 mg/sq cm) were attained. It is now possible to reach a cell potential of 0.620 V at a current density of 2 A/sq cm and at a temperature of 95 C and pressure of 4/5 atm with H2/O2 as reactants. The slope of the linear region of the potential-current density plot for this case is 0.15 ohm-sq cm. With H2/air as reactants and under the same operating conditions, mass transport limitations are encountered at current densities above 1.4 A/sq cm. Thus, the cell potential at 1 A/sq cm with H2/air as reactants is less than that with H2/O2 as reactants by 40 mV, which is the expected value based on electrode kinetics of the oxygen reduction reaction, and at 2 A/sq cm with H2/air as reactant is less than the corresponding value with H2/O2 as reactants by 250 mV, which is due to the considerably greater mass transport limitations in the former case.

Srinivasan, Supramaniam↗

Noise comparison of two 1.2-pressure-ratio fans with 15 and 42 rotor blades

Two 1.829-m-(6-ft-) diameter fans suitable for a quiet engine for future short-takeoff-and-landing (STOL) aircraft were compared. Both fans were designed for a 1.2 pressure ratio with similar weight flows, thrusts, and tip speeds. The first fan, designated QF-9, had 15 rotor blades and 11 stator blades. The rotor was highly loaded and the tip solidity was less than 1. The QF-9 rotor blades had an adjustable pitch feature which can be used for thrust reversal. The second fan, designated QF-6, operated at a moderate loading with a rotor tip solidity greater than 1. Fan QF-6 had 42 rotor blades and 50 stator blades. The low number of rotor blades for QF-9 reduced the frequency of the blade-passage tone below the range of maximum annoyance. In addition to this difference, the QF-9 fan had a somewhat smaller rotor-stator separation than the QF-6 fan. In terms of sound pressure level and sound power level, QF-9 was the noisier fan, with the power level results for QF-9 being about 1 db above those for QF-6 at equivalent operating points as determined by similar stage pressure ratios. At the same equivalent operating points, the maximum perceived noise along a 152.5-m (500-ft) sideline for QF-9 was about 2.5 PNdb below that for QF-6, which indicated that QF-9 was less objectionable to human hearing.

Woodward, R. P.↗

Rotor design for maneuver performance

A method of determining the sensitivity of helicopter maneuver performance to changes in basic rotor design parameters is developed. Maneuver performance is measured by the time required, based on a simplified rotor/helicopter performance model, to perform a series of specified maneuvers. This method identifies parameter values which result in minimum time quickly because of the inherent simplicity of the rotor performance model used. For the specific case studied, this method predicts that the minimum time required is obtained with a low disk loading and a relatively high rotor solidity. The method was developed as part of the winning design effort for the American Helicopter Society student design competition for 1984/1985.

Berry, John D.↗

Recent advances in solid polymer electrolyte fuel cell technology with low platinum loading electrodes

Of all the fuel cell systems only alkaline and solid polymer electrolyte fuel cells are capable of achieving high power densities (greater than 1 W/sq cm) required for terrestrial and extraterrestrial applications. Electrode kinetic criteria for attaining such high power densities are discussed. Attainment of high power densities in solid polymer electrolyte fuel cells has been demonstrated earlier by different groups using high platinum loading electrodes (4 mg/sq cm). Recent works at Los Alamos National Laboratory and at Texas A and M University (TAMU) demonstrated similar performance for solid polymer electrolyte fuel cells with ten times lower platinum loading (0.45 mg/sq cm) in the electrodes. Some of the results obtained are discussed in terms of the effects of type and thickness of membrane and of the methods platinum localization in the electrodes on the performance of a single cell.

Srinivasan, Supramaniam↗

An exploratory investigation of cumulative shock fatigue.

A simple device for producing cumulative shock loading in solids is described. The device uses a ballistic-impact-driven projectile to introduce high-stress waves into a solid. The impact time and load amplitude can be varied to produce fracture in one or several impacts in PMMA rods. The wavefront approached a square wave shape. Materials other than PMMA were loaded to failure to demonstrate the versatility of the device. Fracture morphologies observed with optical and scanning-electron microscopy are described.

Simonson, D.↗

The starting transient of solid propellant rocket motors with high internal gas velocities

A comprehensive analytical model which considers time and space development of the flow field in solid propellant rocket motors with high volumetric loading density is described. The gas dynamics in the motor chamber is governed by a set of hyperbolic partial differential equations, that are coupled with the ignition and flame spreading events, and with the axial variation of mass addition. The flame spreading rate is calculated by successive heating-to-ignition along the propellant surface. Experimental diagnostic studies have been performed with a rectangular window motor (50 cm grain length, 5 cm burning perimeter and 1 cm hydraulic port diameter), using a controllable head-end gaseous igniter. Tests were conducted with AP composite propellant at port-to-throat area ratios of 2.0, 1.5, 1.2, and 1.06, and head-end pressures from 35 to 70 atm. Calculated pressure transients and flame spreading rates are in very good agreement with those measured in the experimental system.

Peretz, A.↗

Transonic compressor technology advancements

The highlights of the NASA program on transonic compressors are presented. Effects of blade shape and throat area on losses and flow range are discussed. Some effects of casing treatment on stall margin are presented. Results of tests with varying solidity are also presented. High Mach number, highly loaded stators are discussed and some results of stator hub slit suction are presented.

Benser, W. A.↗

Transverse Strength of SCS-6 Silicon Carbide Fibers

A diametral compression test was used to measure the transverse strength of SCS-6 SiC fibers before and after heat treatment. Subjecting fibers to diametral compression successfully produced transverse tensile failure in the form of fiber cracking along the same diametral plane in which the compressive load was applied. An analysis of the hoop stress along the diametral plane, in which the effects of the C core were included, showed that there is a large tensile hoop stress concentration in the SiC sheath at the interface between the C core and the SiC sheath, where the stress is 6.3 times greater than the stress present in a solid SiC fiber under identical loading. This high tensile hoop stress concentration promotes crack initiation near the core and significantly limits the capability of these fibers to withstand transverse compressive loading. The maximum tensile hoop stresses, located at the interface between the C core and SiC sheath, at the measured failure loads were 850 MPa for the as-received SCS-6 fiber and 1210 MPa for fibers exposed to a 1-h heat treatment at 1850°C in 138 MPa of Ar.

Jeffrey I. Eldridge↗