Search NASA⌕ Search

SEARCH · Search NASA

Results for “high volume data delivery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A user-friendly plug-and-play cyclic olefin copolymer-based microfluidic chip for room-temperature, fixed-target serial crystallography

Over the past two decades, serial X-ray crystallography has enabled the structure determination of a wide range of proteins. With the advent of X-ray free-electron lasers (XFELs), ever-smaller crystals have yielded high-resolution diffraction and structure determination. A crucial need to continue advancement is the efficient delivery of fragile and micrometre-sized crystals to the X-ray beam intersection. This paper presents an improved design of an all-polymer microfluidic `chip' for room-temperature fixed-target serial crystallography that can be tailored to broadly meet the needs of users at either synchrotron or XFEL light sources. The chips are designed to be customized around different types of crystals and offer users a friendly, quick, convenient, ultra-low-cost and robust sample-delivery platform. Compared with the previous iteration of the chip [Gilbile et al. (2021), Lab Chip , 21 , 4831–4845], the new design eliminates cleanroom fabrication. It has a larger imaging area to volume, while maintaining crystal hydration stability for both in situ crystallization or direct crystal slurry loading. Crystals of two model proteins, lysozyme and thaumatin, were used to validate the effectiveness of the design at both synchrotron (lysozyme and thaumatin) and XFEL (lysozyme only) facilities, yielding complete data sets with resolutions of 1.42, 1.48 and 1.70 Å, respectively. Overall, the improved chip design, ease of fabrication and high modifiability create a powerful, all-around sample-delivery tool that structural biologists can quickly adopt, especially in cases of limited sample volume and small, fragile crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and Commissioning of a Deuterium-Tritium Gas Delivery System for Muon Catalyzed Fusion in a Diamond Anvil Cell

We report the design, commissioning, and operation of deuterium-deuterium (DD) and deuterium-tritium (DT) gas delivery systems developed to load a diamond anvil cell (DAC) beam target for muon-catalyzed fusion (muCF). The DAC approach enables DT fuel to be compressed to GPa pressures at more than twice the liquid density and heated from cryogenic temperatures through 500 K, opening access to a substantially expanded parameter range for muCF kinetics and yield measurements. In this approach, DT is cryo-condensed to a liquid in a minichamber and then compressed in the DAC using a helium-driven pneumatic membrane, achieving high pressures in a millimeter-scale DT sample volume. A DD gas delivery system was designed and used to validate the experimental apparatus, measure the gas quantities needed for filling, develop operational experience, and collect kinetics and yield data with DD targets. The DT gas delivery system adds tritium-specific capabilities for inventory minimization, secondary containment, and activity monitoring. The DT system integrates depleted uranium storage beds and a liquid helium cryogenic condenser used for pressure building and cryopumping. High-purity delivery is provided by a rapid-response palladium permeator. The system is housed in a helium-atmosphere glovebox held at negative pressure with continuous cleanup. We present the process and instrumentation design, a failure modes and effects analysis (FMEA), and data from the experiment's in situ Raman spectrometer, which provides direct confirmation of target loading and composition through the optically clear diamond anvils. The 2024 and 2025 DT campaigns achieved repeatable target fills and operation with no measurable tritium releases to the stack, demonstrating safe, high-purity DT loading at novel density-temperature conditions for muCF studies.

Koukina, Elena [Acceleron Fusion]↗

Neonatal respiratory support strategies—short and long-term respiratory outcomes

Mechanical ventilation (MV), although life-saving, is associated with chronic respiratory morbidity in both preterm and term born infants. New ventilation modes have been developed with the aim of minimising lung injury. These include invasive and non-invasive respiratory support strategies, techniques for less invasive surfactant administration (LISA) and closed-loop automated oxygen control (CLAC) systems. Increasingly, newborn infants with signs of respiratory distress are stabilised on continuous positive airway pressure (CPAP) and receive LISA. Early CPAP when compared to mechanical ventilation reduced the incidence of BPD and respiratory morbidity at 18 to 22 months corrected age. Nasal intermittent positive pressure ventilation reduced treatment failure rates compared to CPAP, but not bronchopulmonary dysplasia (BPD). LISA compared with intubation and surfactant delivery reduced BPD, but there is no evidence from randomised trials regarding long-term respiratory and neurodevelopmental outcomes. Synchronisation of positive pressure inflations with the infant's respiratory efforts used with volume targeting should be applied for infants requiring intubation as this strategy reduces BPD. A large RCT with long term follow up data demonstrated that prophylactic high frequency oscillatory ventilation (HFOV) improved respiratory and functional outcomes at school age, but those effects were not maintained after puberty. CLAC systems appear promising, but their effect on long term clinical outcomes has not yet been explored in randomised trials. Further studies are required to determine the role of newer ventilation modes such as neurally adjusted ventilator assist (NAVA). All such respiratory support strategies should be tested in randomised controlled trials powered to assess long-term outcomes.

Kaltsogianni, Ourania↗

Development of limited-view tomography for measurement of Spray G plume direction and liquid volume fraction

Abstract The method for direct injection of fuel in the cylinder of an IC engines is important to high-efficiency and low-emission performance. Optical spray diagnostics plays an important role in understanding plume movement and interaction for multi-hole injectors, and providing baseline understanding used for computational optimization of fuel delivery. Traditional planar or line-of-sight diagnostics fail to capture the liquid distribution because of optical thickness concerns. This work proposes a high-speed (67 kHz) extinction imaging technique at various injector rotations coupled to computed tomography (CT) for time-resolved reconstruction of liquid volume fraction in three dimensions. The number of views selected and processing were based on synthetic (modeled) liquid volume fraction data where extinction and CT adequately reconstructed each plume. The exercise showed that for an 8-hole, symmetric-design injector (ECN Spray G), only three different views are enough to reproduce the direction of each plume, and particularly the mean plume direction. Therefore, the number of views was minimized for experiments to save expense. Measurements applying this limited-view technique confirm plume–plume variations also detected with mechanical patternation, while providing better spatial and temporal resolution than achieved previously. Uncertainties due to the limited view within pressurized spray chambers, the droplet size, and optically thick regions are discussed. Graphic abstract

42 ENGINEERING↗

Dose Summation Strategies for External Beam Radiation Therapy and Brachytherapy in Gynecologic Malignancy: A Review from the NRG Oncology and NCTN Medical Physics Subcommittees

Definitive, nonsurgical management of gynecologic malignancies involves external beam radiation therapy (EBRT) and/or brachytherapy (BT). Summation of the cumulative dose is critical to assess the total biologic effective dose to targets and organs at risk. Cumulative dose calculation from EBRT and BT can be performed with or without image registration (IR) and biologic dose summation. Among these dose summation strategies, linear addition of dose-volume histogram (DVH) parameters without IR is the global standard for composite dose reporting. This approach stems from an era without image guidance and simple external beam and brachytherapy treatment approaches. With technological advances, EBRT and high-dose-rate BT have evolved to allow for volume-based treatment planning and delivery. Modern conformal therapeutic radiation involves volumetric or intensity modulated EBRT, capable of simultaneously treating multiple targets at different specified dose levels. Therefore, given the complexity of modern radiation treatment, the linear addition of DVH parameters from EBRT and high-dose-rate BT is challenging to represent the combined dose distribution. Deformable image registration (DIR) between EBRT and image guided brachytherapy (IGBT) data sets may provide a more nuanced calculation of multimodal dose accumulation. However, DIR is still nascent in this regard, and needs further development for accuracy and efficiency for clinical use. Biologic dose summation can combine physical dose maps from EBRT and each IGBT fraction, thereby generating a composite DVH from the biologic effective dose. However, accurate radiobiologic parameters are tissue-dependent and not well characterized. A combination of voxel-based DIR and biologic weighted dose maps may be the best approximation of dose accumulation but remains invalidated. The purpose of this report is to review dose summation strategies for EBRT and BT, including conventional equivalent dose in 2-Gy fractions dose summation without image registration, physical dose summation using 3-dimensional rigid IR and DIR, and biologic dose summation. We also provide general clinical workflows for IGBT with a focus on cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

What is the Right Size for a Residential Building Parcel Locker?

Common-carrier parcel lockers present a solution for decreasing delivery times, traffic congestion, and emissions in dense urban areas through consolidation of deliveries. Multi-story residential buildings with large number of residents, and thus a high volume of online package orders, are one of the best venues for installing parcel lockers. But what is the right size for a residential building locker that would suit the residents’ and building managers’ needs? Because of the novelty of parcel lockers, there is no clear guideline for determining the right locker size and configuration for a residential building given the resident population. A small locker would result in packages exceeding capacity and being left in the lobby, increasing the building manager’s workload and confusing and inconveniencing users. On the other hand, a large locker is more expensive, more difficult to install, and unappealing to residents. To answer this question, we installed a common-carrier parcel locker in a residential building in downtown Seattle, WA, U.S.A. Through collecting detailed data on locker usage from the locker provider company, we studied and quantified carriers’ delivery patterns and residents’ online shopping and package pickup behaviors. We then used this information to model the locker delivery and pickup process, and simulated several locker configurations to find the one that best suits the delivery needs of the building. These findings could aid urban planners and building managers in choosing the right size for residential building lockers that meet delivery demand while minimizing costs and contributing to environmental benefits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

3D-printed sheet jet for stable megahertz liquid sample delivery at X-ray free-electron lasers

X-ray free-electron lasers (XFELs) can probe chemical and biological reactions as they unfold with unprecedented spatial and temporal resolution. A principal challenge in this pursuit involves the delivery of samples to the X-ray interaction point in such a way that produces data of the highest possible quality and with maximal efficiency. This is hampered by intrinsic constraints posed by the light source and operation within a beamline environment. For liquid samples, the solution typically involves some form of high-speed liquid jet, capable of keeping up with the rate of X-ray pulses. However, conventional jets are not ideal because of radiation-induced explosions of the jet, as well as their cylindrical geometry combined with the X-ray pointing instability of many beamlines which causes the interaction volume to differ for every pulse. This complicates data analysis and contributes to measurement errors. An alternative geometry is a liquid sheet jet which, with its constant thickness over large areas, eliminates the problems related to X-ray pointing. Since liquid sheets can be made very thin, the radiation-induced explosion is reduced, boosting their stability. These are especially attractive for experiments which benefit from small interaction volumes such as fluctuation X-ray scattering and several types of spectroscopy. Although their use has increased for soft X-ray applications in recent years, there has not yet been wide-scale adoption at XFELs. Here, gas-accelerated liquid sheet jet sample injection is demonstrated at the European XFEL SPB/SFX nano focus beamline. Its performance relative to a conventional liquid jet is evaluated and superior performance across several key factors has been found. This includes a thickness profile ranging from hundreds of nanometres to 60 nm, a fourfold increase in background stability and favorable radiation-induced explosion dynamics at high repetition rates up to 1.13 MHz. Its minute thickness also suggests that ultrafast single-particle solution scattering is a possibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Complementarity of neutron, XFEL and synchrotron crystallography for defining the structures of metalloenzymes at room temperature

Room-temperature macromolecular crystallography allows protein structures to be determined under close-to-physiological conditions, permits dynamic freedom in protein motions and enables time-resolved studies. In the case of metalloenzymes that are highly sensitive to radiation damage, such room-temperature experiments can present challenges, including increased rates of X-ray reduction of metal centres and site-specific radiation-damage artefacts, as well as in devising appropriate sample-delivery and data-collection methods. It can also be problematic to compare structures measured using different crystal sizes and light sources. In this study, structures of a multifunctional globin, dehaloperoxidase B (DHP-B), obtained using several methods of room-temperature crystallographic structure determination are described and compared. Here, data were measured from large single crystals and multiple microcrystals using neutrons, X-ray free-electron laser pulses, monochromatic synchrotron radiation and polychromatic (Laue) radiation light sources. These approaches span a range of 18 orders of magnitude in measurement time per diffraction pattern and four orders of magnitude in crystal volume. The first room-temperature neutron structures of DHP-B are also presented, allowing the explicit identification of the hydrogen positions. The neutron data proved to be complementary to the serial femtosecond crystallography data, with both methods providing structures free of the effects of X-ray radiation damage when compared with standard cryo-crystallography. Comparison of these room-temperature methods demonstrated the large differences in sample requirements, data-collection time and the potential for radiation damage between them. With regard to the structure and function of DHP-B, despite the results being partly limited by differences in the underlying structures, new information was gained on the protonation states of active-site residues which may guide future studies of DHP-B.

36 MATERIALS SCIENCE↗

Efficient Hydrogen Delivery for Microbial Electrosynthesis via 3D-Printed Cathodes

The efficient delivery of electrochemically in situ produced H 2 can be a key advantage of microbial electrosynthesis over traditional gas fermentation. However, the technical details of how to supply large amounts of electric current per volume in a biocompatible manner remain unresolved. Here, we explored for the first time the flexibility of complex 3D-printed custom electrodes to fine tune H 2 delivery during microbial electrosynthesis. Using a model system for H 2 -mediated electromethanogenesis comprised of 3D fabricated carbon aerogel cathodes plated with nickel-molybdenum and Methanococcus maripaludis, we showed that novel 3D-printed cathodes facilitated sustained and efficient electromethanogenesis from electricity and CO 2 at an unprecedented volumetric production rate of 2.2 L CH4 /L catholyte /day and at a coulombic efficiency of 99%. Importantly, our experiments revealed that the efficiency of this process strongly depends on the current density. At identical total current supplied, larger surface area cathodes enabled higher methane production and minimized escape of H 2 . Specifically, low current density (<1 mA/cm 2 ) enabled by high surface area cathodes was found to be critical for fast start-up times of the microbial culture, stable steady state performance, and high coulombic efficiencies. Our data demonstrate that 3D-printing of electrodes presents a promising design tool to mitigate effects of bubble formation and local pH gradients within the boundary layer and, thus, resolve key critical limitations for in situ electron delivery in microbial electrosynthesis.

03 NATURAL GAS↗

Shock-induced bubble jets: a dual perspective of bubble collapse and interfacial instability theory

Interactions between shock waves and gas bubbles in a liquid can lead to bubble collapse and high-speed liquid jet formation, relevant to biomedical applications such as shock wave lithotripsy and targeted drug delivery. This study reveals a complex interplay between acceleration-induced instabilities that drive jet formation and radial accelerations causing overall bubble collapse under shock wave pressure. Using high-speed synchrotron X-ray phase contrast imaging, the dynamics of micrometre-sized air bubbles interacting with laser-induced underwater shock waves are visualised. These images offer full optical access to phase discontinuities along the X-ray path, including jet formation, its propagation inside the bubble, and penetration through the distal side. Jet formation from laser-induced shock waves is suggested to be an acceleration-driven process. A model predicting jet speed based on the perturbation growth rate of a single-mode Richtmyer–Meshkov instability shows good agreement with experimental data, despite uncertainties in the jet-driving mechanisms. The jet initially follows a linear growth phase, transitioning into a nonlinear regime as it evolves. To capture this transition, a heuristic model bridging the linear and nonlinear growth phases is introduced, also approximating jet shape as a single-mode instability, again matching experimental observations. Upon piercing the distal bubble surface, jets can entrain gas and form a toroidal secondary bubble. Linear scaling laws are identified for the pinch-off time and volume of the ejected bubble relative to the jet’s Weber number, characterising the balance of inertia and surface tension. At low speeds, jets destabilise due to capillary effects, resulting in ligament pinch-off.

Drops and Bubbles: Bubble dynamics↗

Financial Analysis of the High Flow Experiment conducted at the Glen Canyon Dam during Water Year 2023

The Glen Canyon Dam (GCD) is a Colorado River Storage Project (CRSP) power resource that is a component of the Salt Lake City Area Integrated Projects (SLCA/IP). The 2016 record of decision (ROD) for the GCD long-term experimental and management plan (LTEMP) final Environmental Impact Statement (EIS) specified criteria for GCD monthly water releases, daily and hourly operating limits, and experimental releases. This report examines the financial implications of the high flow experiment (HFE) conducted at GCD during the spring of Water Year (WY) 2023 as required by the LTEMP HFE Protocol. This report is part of a series of reports that describe the financial costs of LTEMP experimental releases since the 2016 ROD was adopted in January 2017. Previous reports analyzed the impact of several past HFEs and Bug Flow Experiments. This report focuses on the HFE conducted in April 2023. For this experimental release, financial costs of approximately $1.33 million were incurred because the HFE required sustained water releases exceeding the power plant’s maximum turbine flow rate. In addition, during the experiment, operators were not allowed to shape GCD power production, either to follow Firm Electric Service (FES) customer day-ahead energy deliveries or to respond to market prices. This study identifies the main factors contributing to the HFE costs and examines the interdependencies among these factors. It applies an integrated set of tools to estimate Western Area Power Administration (WAPA) financial impacts by simulating GCD under two types of cases; namely, (1) a “With Experiment” case that mimics the operations that actually occurred and (2) a “Without Experiment” case that simulates operations under the assumption that the HFE did not occur. The “With Experiment” case mimics operations during the HFE and the entire month the HFE occurred. It complies with LTEMP hourly and daily operating criteria. The “Without Experiment” case assumes that the HFE did not occur. The monthly water release volume is assumed to be identical under both cases. The Colorado River Storage Project Python-based model (CRiSPPy) model was the main modeling tool used to simulate the dispatch of the GCD hydropower plant and associated water releases from Lake Powell. In the modeling process, the research team used extensive data sets and historical information on SLCA/IP power plant characteristics, hydrologic conditions, and WAPA’s power purchases and sales prices. In addition to estimating the financial impact of the HFE, the team used the CRiSPPy model to gain insights into the interplay among ROD operating criteria, exceptions made to criteria to accommodate the HFE, and WAPA operating practices.

13 HYDRO ENERGY↗