Radiation Imaging with Event Camera

Neuromorphic or event-based imaging is a new, commercially available sensor technology inspired by how the human eye works. Instead of measuring frames at a fixed rate, the camera measures changes in pixel intensity asynchronously. This difference in readout architecture results in a high dynamic range and low latency. Event-based cameras have been used in a variety of applications, including object tracking, navigation, and lidar technologies. However, event-based cameras have not been adequately researched for their ability to image high-energy particles. This report explores the use of an event camera for imaging alpha, beta, and X-rays particles, when coupled with scintillator screens to convert high-energy particles into visible light. Methods to process event data were developed and are presented here, along with the results. The event camera can measure alpha and beta particles with comparable performance to that of a conventional camera. Event cameras can also image higher-activity sources and offer the possibility of discriminating particle interaction types on the basis of timing differences, which typical cameras cannot do. Additionally, event cameras can image objects with an X-ray source when the source strength dynamically changes but does not create a high-contrast image during static X-ray measurement.

47 OTHER INSTRUMENTATION

Adjustable collimation for dark-field proton radiography contrast enhancement

A dark-field imaging condition established through pre- and post-object beam collimation has been tested for a variety of different settings at the proton radiography facility (pRad) at Los Alamos National Laboratory. This technique facilitates imaging of thin samples and materials with small areal density changes with 800 MeV protons that would otherwise appear nearly transparent for high energy protons. In the configuration that was examined, the pre-object (upstream) collimator is utilized to remove protons with large scattering angles prior to the target object. The post-object collimation entails a combination of a conventional collimator, which eliminates protons with large scattering angles after target interaction, and an inverse collimator. The inverse collimator removes unscattered protons traveling on the beam axis and those with smaller scattering angles up to a desired angle. This establishes a dark-field condition by permitting solely protons that exhibit scattering angles from target interaction within a designated range to contribute to the image. This study explores the potential of combining different sized collimators for pre- and post-object collimation. The objective is to optimize contrast for a range of samples with minimal areal density variations. A series of dark-field conditions are explored employing a remote-controlled collimator wheel and the contrast-to-noise ratio, spatial resolution, and proton transmission are compared for those combinations. It is found that the contrast-to-noise ratio can be substantially enhanced for thin samples and low areal density objects, thereby facilitating capturing high-contrast images of objects that were previously invisible to high energy protons.

43 PARTICLE ACCELERATORS

Control Algorithms for Dual-wavefront Sensor Single-conjugate Adaptive Optics

High-contrast imaging systems using active control with adaptive optics (AO) are often limited by non-common path (NCP) aberrations that are seen only at the final science image. AO systems employing focal-plane wavefront sensors (FP-WFSs) are able to simultaneously correct NCP aberrations and measure science images, but they typically require a second stage of control that adds system cost and complexity. We present control algorithms to augment AO systems with FP-WFSs within their existing control setup. We demonstrate inter-arm NCP aberration transfer can be mitigated through temporal filtering, present frequency- and time-domain validation of controller stability and performance, and discuss the optimality of the chosen controllers. This work will enable the development, testing, and installation of FP-WFS technologies for direct imaging of exoplanets.

79 ASTRONOMY AND ASTROPHYSICS

Fast quantum ghost imaging with a single-photon-sensitive time-stamping camera

Quantum ghost imaging (QGI) leverages correlations between entangled photon pairs to reconstruct an image using light that has never physically interacted with an object. Despite extensive research interest, this technique has long been hindered by slow acquisition speeds, due to the use of raster-scanned detectors or the slow response of intensified cameras. Here, we utilize a single-photon-sensitive time-stamping camera to perform QGI at ultra-low-light levels with rapid data acquisition and processing times, achieving high-resolution and high-contrast images in under 1 min. Our work addresses the trade-off between image quality, optical power, data acquisition time, and data processing time in QGI, paving the way for practical applications in biomedical and quantum-secured imaging.

Mavian, Alex (ORCID:0000000279448830)

Imaging Microscope For "Water-Window" X Rays

Proposed microscope operates in "water-window" part of x-ray spectrum. Contains spherical-mirror substrates coated with multiple thin layers of material exhibiting Bragg reflection at wavelength at which water transparent. Suited for making high-resolution, high-contrast images for microbiological research.

Hoover, Richard B.

The brighter-fatter effect in the JWST MIRI Si:As IBC detectors: I. Observations, impact on science, and modeling

Context.The Mid-Infrared Instrument (MIRI) on board theJames WebbSpace Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by sampling up the ramp. For uniform or low-contrast illumination, the pixel ramps become nonlinear in a predictable way, but in areas of high contrast, the nonlinearity curve becomes much more complex. The origin of the effect is poorly understood and currently not calibrated out of the data. Aims.We provide observational evidence of the brighter-fatter effect (BFE) in MIRI conventional and high-contrast coronagraphic imaging, low-resolution spectroscopy, and medium-resolution spectroscopy data, and we investigate the physical mechanism that gives rise to the effect on the MIRI detector pixel raw voltage integration ramps. Methods.We used public data from the JWST/MIRI commissioning and Cycle 1 phase. We also developed a numerical electrostatic model of the MIRI detectors using a modified version of the publicPoisson_CCDcode. Results.We find that the physical mechanism behind the BFE manifesting in MIRI data is fundamentally different to that of charge-coupled devices and photodiode arrays such as the Hawaii-XRG near-infrared detectors used by the NIRISS, NIRCam, and NIRSpec instruments on board JWST. Observationally, the BFE makes the JWST MIRI data yield 10–25% larger point sources and spectral line profiles as a function of the relative level of de-biasing of neighboring detector pixels. This broadening impacts the MIRI absolute flux calibration, time-series observations of faint companions, and point spread function modeling and subtraction. We also find that the intra-pixel 2D profile of the shrinking Si:As IBC detector depletion region directly impacts the accuracy of the pixel ramp nonlinearity calibration model.

Astronomy & Astrophysics

Mariner Venus-Mercury 1973 encounter strategy.

This paper describes the selection of launch and arrival conditions and Venus and Mercury encounter aiming zones to maximize the science return from the Mariner Venus-Mercury mission. A single Mariner spacecraft will be launched in November, 1973, fly by Venus in early February, 1974, and encounter Mercury (the primary target) in late March, 1974. Mercury aiming points will provide: (1) sun and earth occultation, (2) 1000 km periapsis altitude, and (3) return to Mercury after 176 days (two Mercury years). The selected Mercury arrival dates allow high-contrast television imaging. Aiming points at Venus allow gravity assist to Mercury and also permit earth occultation.

Shirley, D. L.

Finding the lost river gas field - Lineament density analysis in hydrocarbon exploration

A comparative trial analysis of lineament density in 1:500,000 Landsat and 1:48,000 aerial Landsat-simulator images of a gas-field region in West Virginia is presented. The high-contrast, band 4, 5, 7 color composite Landsat image was interpreted independently by two analysts. The slightly different lineament maps were evaluated in terms of lineament-density variation in 10 x 10-km areas, and the resulting areal-variation maps are found to be statistically equivalent. High lineament density is shown to be associated with productive gas wells. Comparison of ground-based substructural contour maps and lineament-density analyses of the Landsat-simulator images reveals good correlation between density maxima or isopleths and substructural features associated with hydrocarbon formations. A hydrocarbon-exploration strategy using both Landsat and aerial images is proposed.

Lang, H. R.

Hard X-ray and gamma-ray imaging spectroscopy for the next solar maximum

The objectives and principles are described of a single spectroscopic imaging package that can provide effective imaging in the hard X- and gamma-ray ranges. Called the High-Energy Solar Physics (HESP) mission instrument for solar investigation, the device is based on rotating modulation collimators with germanium semiconductor spectrometers. The instrument is planned to incorporate thick modulation plates, and the range of coverage is discussed. The optics permit the coverage of high-contrast hard X-ray images from small- and medium-sized flares with large signal-to-noise ratios. The detectors allow angular resolution of less than 1 arcsec, time resolution of less than 1 arcsec, and spectral resolution of about 1 keV. The HESP package is considered an effective and important instrument for investigating the high-energy solar events of the near-term future efficiently.

Hudson, H. S.

Modulation transfer function measurement technique for small-pixel detectors

A modulation transfer function (MTF) measurement technique suitable for large-format, small-pixel detector characterization has been investigated. A volume interference grating is used as a test image instead of the bar or sine wave target images normally used. This technique permits a high-contrast, large-area, sinusoidal intensity distribution to illuminate the device being tested, avoiding the need to deconvolve raw data with imaging system characteristics. A high-confidence MTF result at spatial frequencies near 200 cycles/mm is obtained. We present results at several visible light wavelengths with a 6.8-micron-pixel CCD. Pixel response functions are derived from the MTF results.

Marchywka, Mike

Smartphone application for visualizing building air leakage

Annually, unwanted air leakage through building envelopes accounts for 4 quads of energy consumption in the United States, which translates to about 10% of total building energy consumption. Locating and sealing leakage sites is crucial fordecreasing building energy consumption. Smartphones are ubiquitous and contain sophisticated cameras and highperformance processors that could be employed to visualize air leakage using the background-oriented schlieren imaging technique, making leak detection cheaper and easier. This technique requires a textured and high-contrast background such as a brick or concrete masonry unit wall, a building air leak that has a temperature difference compared with the ambient air, and an imaging system. This work focuses on using smartphones as the imaging system to visualize air leakages. The paper discusses application development and the results of testing to determine leakage visualization performance as a function of leak temperature. The results show that leaks with a temperature difference greater than 16°C compared with the ambient air temperature were visualized using existing smartphones.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)

Monitoring Coating Thickness During Plasma Spraying

High-resolution video measures thickness accurately without interfering with process. Camera views cylindrical part through filter during plasma spraying. Lamp blacklights part, creating high-contrast silhouette on video monitor. Width analyzer counts number of lines in image of part after each pass of spray gun. Layer-by-layer measurements ensure adequate coat built up without danger of exceeding required thickness.

Miller, Robert A.

Electrically Reconfigurable Liquid Metal Nanophotonic Platform for Color Display and Imaging

Dynamically tunable optical materials and device architectures are essential for future photonic technologies, yet conventional solid metals lack the intrinsic tunability required for advanced functionalities. Gallium-based liquid metals (LMs) present an appealing alternative thanks to their distinctive mechanical and optical properties; however, their practical integration in tunable photonic elements remains largely unexplored. Here, in this study, an electrochemically controlled nanophotonic platform is demonstrated that integrates a dynamically reconfigurable LM ground plane with gold nanoantenna arrays within a microfluidic system, enabling precise and reversible modulation of optical resonances across the visible to mid-infrared spectral ranges. By employing moderate operational voltages (1.5–3.0 V), real-time tuning of high-resolution structural color patterns is achieved through nanoscale control of the interfacial gap between the LM and Au nanoantennas. This innovative platform facilitates electrically programmable, high-contrast color patterns suitable for dynamic optical displays, secure anti-counterfeiting labels, and imaging applications. Additionally, this platform enables tunable mid-infrared spectral responses, which may be utilized for chemical and biological sensing applications. This versatile integrated LM-based nanophotonic platform opens new paths toward multifunctional, actively tunable/reconfigurable photonic device and system technologies.

Imaging

Solution-Processed Temperature-Adaptive Radiative Paint as a Thermal Imaging Sensitizer

Thermography detects mid-infrared radiation from surfaces based on the Stefan-Boltzmann law, mapping surface temperatures and potentially revealing subsurface thermal activity. Recent developments offer an alternative strategy to traditional camera-based improvements: a thermal imaging sensitizer (TIS) coating whose emissivity increases sharply with local temperature, amplifying small thermal variations into high-contrast signals. Existing TIS structures are nanofabricated solid membranes and face significant challenges in fabrication complexity. Here, in this study, we present a solution-processed, liquid form of TIS, termed temperature-adaptive radiative paint (TARP), to address these limitations. TARP offers drastically reduced fabrication costs, scalability to large areas, applicability to curved surfaces, and an extended operating temperature range, while maintaining the function of temperature amplification. Application of TARP enhances small temperature contrast by more than 3 times, substantially improving ambient thermography and enabling broader applications such as detection of structural defects and hot spots in electronic components.

paint

Opaque Contact Lens For Tracking Motion Of Eye

Opaque contact lens facilitates measurements of movements of eye; particularly, torsional movements. Lens, marked with pair of indices at diameter of 0.5 mm, provides stable, high-contrast reference for measurements of angular position and velocity of eye by use of video-image-analysis techniques. Intended for use in experiments on response of eye to vestibular balance mechanism.

Zografos, James L., II

Determining the nanostructure of polymer foams using 3D ptycho-tomography for inertial fusion energy applications

Polymer foams play a critical role in contemporary inertial fusion energy (IFE) target designs by enhancing energy yield and optimizing implosion dynamics. However, the lack of high-resolution characterization of the nanostructure of these foams restricts progress in fusion science. In this work, we demonstrate the first high-resolution three-dimensional (3D) reconstruction of a low-density, Si-doped polymer foam fabricated via two-photon polymerization, using ptychographic x-ray computed tomography (PXCT) at an x-ray free electron laser (XFEL). This imaging method reconstructs two-dimensional (2D) attenuation and phase information at multiple sample angles that are combined into a 3D density map used to extract local mass density and determine structural dimensions. We achieve a 2D spatial resolution of 19 ± 3 nm on a high-contrast Ronchi pattern target and 78.7 ± 3 nm for low-contrast polymer foams, marking a significant advancement for XFEL-based ptychography of low-density materials. Furthermore, our experimental results reveal an average foam strut thickness of 1.17 ± 0.4 μm, consistent with fabrication expectations, and a reconstructed average mass density of 0.35 g/cc, aligning closely with the predicted density of 0.29 g/cc. These findings provide important insights for improving foam design and refining radiation hydrodynamics modeling in future IFE experiments. Our study establishes PXCT at an XFEL as a powerful tool for high-resolution characterization of fusion-relevant materials, paving the way for enhanced target performance in IFE research.

Hancock, Levi [Colorado State Univ., Fort Collins,

Multi-frequency progressive refinement for learned inverse scattering

Interpreting scattered acoustic and electromagnetic wave patterns is a computational task that enables remote imaging in a number of important applications, including medical imaging, geophysical exploration, sonar and radar detection, and nondestructive testing of materials. However, accurately and stably recovering an inhomogeneous medium from far-field scattered wave measurements is a computationally difficult problem, due to the nonlinear and non-local nature of the forward scattering process. We design a neural network, called Multi-Frequency Inverse Scattering Network (MFISNet), and a training method to approximate the inverse map from far-field scattered wave measurements at multiple frequencies. We consider three variants of MFISNet, with the strongest performing variant inspired by the recursive linearization method — a commonly used technique for stably inverting scattered wavefield data — that progressively refines the estimate with higher frequency content. MFISNet outperforms past methods in regimes with high-contrast, heterogeneous large objects, and inhomogeneous unknown backgrounds.

97 MATHEMATICS AND COMPUTING

Non-Destructive, Three-Dimensional Imaging of Processes in the Rhizosphere Utilizing High Energy Photons

Soil structure, which can be described as the aggregation and distribution of pore spaces, regulates carbon, nutrient, and water cycling across the Earth system. Yet the inability to make quantitative, dynamic, in situ measurements of soil structure and rhizosphere carbon flow has prevented meaningful incorporation of soil structural processes into Earth System Models (ESMs). The key limitations are: (i) Lack of scale integration between micron-scale soil structure and ecosystem-scale models, (ii) Poor functional linkage between soil structural properties and biogeochemical processes, and (iii) Absence of dynamic 3D measurements of rhizosphere structural changes and carbon transformations. To address these challenges, we developed a new integrated positron emission tomography (PET) - microcomputed tomography (CT) imaging platform that enables the first 4D (spatial 3D and time), non-invasive, quantitative imaging of carbon allocation and rhizosphere structural dynamics in living plants and intact soils. The system combines: • Rhizo-PET (R-PET): a high-resolution positron emission tomography scanner optimized for 11 CO 2 tracing in plant roots. • a-Se micro-CT: a high-contrast, high-spatial resolution CT system based on amorphous selenium (a-Se) direct conversion technology, enabling micron-scale visualization of soil structure and root–soil interfaces. Together, these advances allow us to quantify how carbon exudates move, transform, and stabilize within the rhizosphere, directly informing missing processes in BER-relevant carbon cycle models.

42 ENGINEERING