Search NASA⌕ Search

SEARCH · Search NASA

Results for “high-energy X-ray detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High energy X-ray spectrum of Her X-1

Line features in the high-energy X-ray spectrum of Her X-1 are attributed to an approximately 1% change in detector gain. The spectrum was obtained by a high-energy X-ray detector aboard OSO-8. The time-averaged spectrum of Her X-1 for the period August 31-Sept. 6, 1977 is presented; the count-rate spectrum was corrected for an average change in gain of 0.7%. The best fit power-law is reported.

Dennis, B. R.↗

Detection of high-energy X-rays from the galactic center region

Results are presented from repeated scans of the galactic center region made with the high-energy X-ray detector on OSO 8 during the five days of Sept. 20-25, 1978. The observations show a strong flux of high-energy excluding GX 1 + 4 and GX 3 + 1. The photon-number spectrum of this flux is harder than that of GX 1 + 4 measured during the same interval.

Dennis, B. R.↗

Upper limits on the cyclotron lines from Her X-1 as observed with OSO-8

Observations of Her X-1 were obtained during its ON-state in September, 1977, with the high-energy X-ray detector on board OSO-8. Upper limits on the line fluxes at 60 and 135 keV based on these observations are above, and hence consistent with, the positive results reported by Trumper, et al from a balloon flight during the same time interval. A detailed analysis of the time-variable et al background spectrum suggests that the line emission, especially in the time-averaged spectrum of Her X-1 previously reported by other workers at 25, 60, and 135 keV, is due to instrumental effects. The spectrum obtained with OSO-8 in September, 1977, is considerably steeper than that observed in pre-1976 balloon flights. These results are consistent with the results obtained by Trumper showing a decrease in the effective temperature of Her X-1 between May, 1976, and September, 1977.

Dennis, B. R.↗

The high-energy celestial X-ray instrument on board OSO-8

The 20 keV-3 MeV celestial X-ray detector on the OSO-8 is described. The primary objectives of this instrument are to measure the energy spectrum of cosmic X-ray sources above 20 keV and to search for time variations, both periodic and irregular, in the intensity of the sources detected. The detector consists of two optically isolated central crystals shielded by a large, active collimator. The sensitive area is 27.5 sq cm and the field-of-view is 5 deg FWHM. The instrument is mounted in the wheel section of OSO-8 with the axis of its field of view offset by 5 deg from the negative spin axis of the wheel. The minimum detectable intensity of a point source which is brought to within 5 deg of the negative spin axis for greater than one day is about 10 to the minus fifth power photons/sq cm-sec at 100 keV.

Dennis, B. R.↗

PKS 2155-304 - Relativistically beamed synchrotron radiation from a BL Lacertae object

The previously reported variability by a factor of two in less than a day is confirmed for the newly discovered BL Lac object PKS 2155-304, by means of the HEAO 1 A-2 experiment's medium- and high-energy detectors. An interpretation of the overall spectrum from radio through X-rays in terms of a synchrotron self-Compton model yields a good description of the data if relativistic beaming is allowed for. The presence of jets is inferred without their direct observation through consideration of the spectrum, combined with an estimate of the size of the source.

Urry, C. M.↗

The development and test of multi-anode microchannel array detector systems. 2: Soft X-ray detectors

The techniques and procedures for producing very-large-format pulse-counting array detector systems for use in forthcoming high-energy astrophysics facilities were defined, and the structures and performance characteristics of high-sensitivity photocathodes for use at soft X-ray wavelengths between 100 and 1 A were determined. The progress made to date in each of these areas are described and the tasks that will be undertaken when the program is continued are summarized.

Timothy, J. G.↗

Hard X-ray properties of cataclysmic variables

A brief summary is presented of results for AM Her, EX Hya, SS Cyg, and U Gem obtained with the high-energy detectors of the HEAO A2 experiment from 2-60 keV and the Solid State Spectrometer Experiment with the Monitor Proportional Control on the Einstein Observatory. It is found that the magnetic variable AM Her and the dwarf novae are similar in having bremsstrahlung of similar luminosity with temperatures for the dwarf novae that can approach that for AM Her and in flickering on a time scale of 5-15 min. But in general these dwarf novae temperatures are about 2-10 times lower. Only in Am Her is there evidence in the spectrum and eclipses for a small spot very close to the white dwarf surface. Most of the hard X-rays in SS Cyg, EX Hya, and U Gem are not pulsed, and the hard X-ray fluxes observed have never been significantly absorbed or degraded.

Swank, J. H.↗

Low fluxes of X-rays

Analytic and experimental investigations of the interactions of high-energy protons with spacecraft materials and light nucleus atoms were conducted. Irradiation of typical materials for scintillation detectors using accelerator-produced energetic protons and associated theoretical calculations indicate activity within detectors produced by this mechanism is significant to detection of low-level cosmic gamma radiation. Samples of several materials were flown aboard Skylab to obtain measures of the neutron and proton flux environment. Extremely weak activity was produced in the samples. Calculations of interactions of intermediate-energy protons with light nuclei were performed and a more complete theoretical model programmed for digital computation. Preliminary results appear promising for calculating products of such interactions.

Source record↗

High EneRgy Observatory for Imaging X-rays (HEROIX) Mission Concept

The High EneRgy Observatory for Imaging X-rays (HEROIX) is a next-generation broadband X-ray space telescope concept under development as a Medium-Class Explorer mission. Building on more than three decades of replicated NiCo shell technology at NASA’s Marshall Space Flight Center, HEROIX will deliver 5 arcsecond half-power-diameter imaging resolution in the hard X-ray band. The observatory will incorporate four co-aligned telescopes with advanced multilayer coatings, extending the bandpass into the hard X-ray regime and providing an integrated effective area of 380 cm² at 30 keV. A suite of focal plane detectors will enable imaging capability throughout its 1–80 keV bandpass. This combination of angular resolution and high-energy coverage will open new windows into non-thermal processes in extreme astrophysical environments. HEROIXwill deliver transformative science, advancing the astrophysics community’s understanding of supernova physics, the X-ray binary population of the Galactic Center, accretion-driven galaxy evolution, and the origin of the Cosmic X-ray Background.

Nick Thomas↗

Evidence for beam-stimulated precipitation of high energy electrons

Observations have been made in conjunction with two active magnetospheric experiments (Araks and Trigger) in which an electron beam apparently stimulated the precipitation of high-energy electrons from the deep magnetosphere. In both experiments, the data were obtained from rocket-boosted, parachute-borne X-ray bremsstrahlung detectors which were initially deployed at an altitude of 80 km near the foot of the flux tubes affected by each experiment. The X-ray results from these experiments are discussed and compared in terms of beam physics. It is concluded that artificial electron beams injected from ionosphere can stimulate pitch angle scattering and precipitation of higher energy electrons in the magnetosphere via a particle-wave-particle interaction. This mechanism operates over at least one order of magnitude of injection energy.

Bering, E.↗

An X-ray shadowgraph to locate transient high-energy celestial sources

A new technique has been developed to locate strong, transient X-ray sources such as the recently discovered gamma ray bursts. The instrument, termed a shadowgraph, locates sources by detecting the X-ray shadow cast by a large occulting mask pattern on an imaging detector. Angular resolutions of from 2 to 10 arc minutes are obtainable while essentially full sky coverage is maintained. The optimum energy range of operation is between 20 keV and 100 keV. The high efficiency X-ray imaging detectors, which make it possible to locate bursts with intensities down to approximately 10 photons/sq cm sec, are capable of detecting single 20 keV photons with a spatial resolution of approximately 0.2 mm. The detectors consist of an X-ray to optical conversion phosphor, a multistage image intensifier, and a CCD image readout.

Fishman, G. J.↗

Observations of NGC 4151 at 2 keV to 2 MeV from HEAO 1

Broad-range X-ray and gamma-ray spectra of the Seyfert galaxy NGC 4151 obtained by the UCSD/MIT and GSFC/CIT detectors of HEAO 1 are presented. For two out of the three observational epochs the best-fit model is a power law with photon index 1.6 + or - 0.1 in the 2 keV-2 MeV spectral range. The third observation, in June, 1978, when the intensity was a factor of 2 higher, requires a change above 50 keV from a similar power law to a steeper power law or an exponential. Through comparisons with previous observations, a weak correlation is found between the high-energy spectral index and the flux level. Comparison of these data and other X-ray and gamma-ray observations with the spectra expected from several possible emission mechanisms supports a synchrotron-self-Compton model using infrared target photons or a Compton-scattering process involving X-rays of less than 10 keV energies.

Baity, W. A.↗

A position-sensitive X-ray detector for the HEAO-A satellite.

A position-sensitive, low-energy proportional counter system is described which will be used on the High-Energy Astronomical Observatory, Mission A, spacecraft. The associated system incorporates the capability to employ pulse-shape discrimination for background rejection and interpolation circuitry to locate the centroid of an X-ray event with an accuracy of approximately one eighth the cathode-wire spacing.

Held, D.↗

A study of the cosmic sources of hard X-rays

An actively-shielded, high-energy X-ray telescope was launched onboard OSO-8 on 21 June 1975. The primary objectives of this experiment are the measurements of the energy spectrum of discrete cosmic X-ray sources in the range 20 keV to 3 MeV and of the temporal variations in the intensity of each source detected with a time resolution of 0.3 msec. This detector provides the highest duty factor and the finest time resolution of any of its kind for observations over a period of up to 10 days. The background spectrum of this detector in orbit was monitored continuously since shortly after launch. The minimum detectable source strength is estimated to be between 10,000 and 100,000 photons/sq-cm-sec keV, limited primary by the effects of induced radioactivity. From 16 July through 18 July 1975, the X-ray binary, Cen X-3, was observed with the hard X-ray telescope.

Dennis, B. R.↗

A hard X-ray imaging instrument for solar and cosmic sources

A hard X-ray imaging instrument is described which is capable of high-resolution imaging of solar and cosmic hard X-ray sources between 2 and 80 keV during Shuttle sortie flights. The properties of solar burst sources and the resulting instrument requirements are discussed. The instrument envelope of 1.2 x 1.2 x 3.0 meters includes a tungsten multigrid collimator which has 4-arcsec resolution, a 40-arcmin response envelope and a point-source effective area of 26 sq cm. A combination of periodic fan beams and nonperiodic pencil beams enables a unique deconvolution to be achieved within a 128 x 128 arcsec field without mechanical scanning. The detector system is a set of direct-readout 40 atm-cm xenon-filled proportional counters designed to minimize background. The instrument is capable of refurbishment to optimize the collimator configuration for specific solar or cosmic scientific objectives, to upgrade the angular resolution, or to extend the high-energy response.

Hurford, G. J.↗

HEAO 1 observations of high-energy X-rays from 3C273

The first detection of high energy (13 to 120 keV) X rays from the quasar 3C273, made by the HEAO 1 satellite, is reported. Observations were made with the 13 to 180 keV slat collimated detectors of the high energy X-ray and low energy gamma-ray (A4) experiment during December 1977-January 1978 and June-July 1978. Results are consistent with the previously observed X-ray flux variability on a scale of months. Photon count rates are presented for each of five energy bands and count rate and photon spectra for the June through July 1978 observations are derived. A comparison of the data obtained with that at lower X-ray energies and higher gamma-ray energies indicates that there is an overall spectral steepening from low to high energies and a possible break near 20 keV, which may be due to the gamma rays originating from a different region than that of the X rays.

Primini, F. A.↗

High energy primary electron spectrum observed by the emulsion chamber

A detector of the emulsion chamber type is used to measure the energy spectrum of cosmic-ray electrons. Two large emulsion chambers, each having an area of 40 by 50 sq cm, are exposed for about 25.5 hr at an average pressure altitude of 3.9 mbar. About 500 high-energy cascades (no less than about 600 GeV) are detected by searching for dark spots on the X-ray films. A power-law energy dependence formula is derived for the spectrum of primary cosmic-ray electrons in the energy region over 100 GeV. The results are in good agreement with the transition curves obtained previously by theoretical and Monte Carlo calculations.

Nishimura, J.↗