Search NASA⌕ Search

SEARCH · Search NASA

Results for “high-temperature oscillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Oscillator strengths of ultraviolet Fe I lines from hook-method measurements on a furnace

The hook method, which makes use of anomalous dispersion, was employed to measure 107 absolute oscillator strengths of Fe I on a high-temperature furnace. The absolute scale was established before and after each run by recording the anomalous dispersion near a strong resonance line with accurately known f-value. The results cover three lines with wavelengths from 1934 to 1941 A, and 104 lines lying between 2084 and 3194 A - mostly transitions originating from the a 5 D ground state. The average error of the f-values is plus or minus 20%, and the largest and smallest errors given are plus or minus 10 and plus or minus 60%. Disagreements exceeding an order of magnitude are found with previous values in the literature.

Banfield, F. P.↗

Influence of damping on quantum interference - An exactly soluble model

This paper reports the result of a calculation which shows the effect of damping on the quantum interference of two Gaussian wave packets in a harmonic potential. The influence-functional method, which seems to be the most appropriate one for this kind of calculation, is used. It is shown that quantum-interference effects are severely diminished by the presence of damping even when its influence on the system is only light. The corrections to the undamped formulas are always expressible in terms of the phenomenological damping constant, the temperature (in the high-temperature limit), the cutoff frequency of the reservoir oscillators, and the mean number of quanta of energy intially present in the system. Both weakly and strongly damped systems are analyzed in the regime of low and high temperatures.

Caldeira, A. O.↗

Quantum Sensing using Geometrical Phase in Qubit-Oscillator Systems

We present a quantum sensing protocol for coupled qubit-oscillator systems that surpasses the standard quantum limit (SQL) by exploiting a geometrical phase. The signal is encoded in the geometrical phase that is proportional to the area enclosed in oscillator phase space. This area is amplified through squeezing, enabling sensitivities beyond the SQL. Our method is independent of oscillator's initial state, amenable to sensing with high-temperature or logical error-corrected states. The protocol shows robustness to qubit Markovian noise and preserves its state-independence, underscoring its practicality for next-generation quantum metrology. We demonstrate application to force sensing beyond the SQL in longitudinally coupled systems, and to high-precision measurements of couplings and pulse calibration surpassing SQL in dispersively coupled circuit quantum electrodynamics (cQED) architectures.

Suri, Nishchay [LBNL, Berkeley]↗

Oscillator strengths of Cr I lines lying between 200 and 541 nm from hook-method and absorption measurements in a furnace

Measurements of 148 oscillator strengths of neutral chromium transitions were made on Cr vapor in a high-temperature furnace by the hook and absorption methods for strong and weak lines, respectively. With the aid of a 5D-z 5F0 multiplet, the product of the oscillator strengths of the lines of this multiplet with the column densities of their respective lower levels could be determined, and by using estimated oscillator strengths for these lines, all data could be put on a common relative scale. This scale was altered so that the results were matched with relative emission intensities. Results are compared with other authors' results. A correction to the hook method constant was also determined.

Huber, M. C. E.↗

Low-cost FM oscillator for capacitance type of blade tip clearance measurement system

The frequency-modulated (FM) oscillator described is part of a blade tip clearance measurement system that meets the needs of a wide class of fans, compressors, and turbines. As a result of advancements in the technology of ultra-high-frequency operational amplifiers, the FM oscillator requires only a single low-cost integrated circuit. Its carrier frequency is 42.8 MHz when it is used with an integrated probe and connecting cable assembly consisting of a 0.81 cm diameter engine-mounted capacitance probe and a 61 cm long hermetically sealed coaxial cable. A complete circuit analysis is given, including amplifier negative resistance characteristics. An error analysis of environmentally induced effects is also derived, and an error-correcting technique is proposed. The oscillator can be calibrated in the static mode and has a negative peak frequency deviation of 400 kHz for a rotor blade thickness of 1.2 mm. High-temperature performance tests of the probe and 13 cm of the adjacent cable show good accuracy up to 600 C, the maximum permissible seal temperature. The major source of error is the residual FM oscillator noise, which produces a clearance error of + or - 10 microns at a clearance of 0.5 mm. The oscillator electronics accommodates the high rotor speeds associated with small engines, the signals from which may have frequency components as high as 1 MHz.

Barranger, John P.↗

Oscillator strengths of ultraviolet Ni I lines from hook-method and absorption measurements in a furnace

Measurements of the oscillator strengths of the ultraviolet lines of neutral nickel obtained by the use of the combined hook and absorption technique are reported. A total of 221 transitions in the range 1964-4094 A was measured for nickel atoms from a high-temperature graphite furnace (2000-2500 K) using a continuum background source, a Mach-Zehnder interferometer and a 3-m Czerny-Turner spectrograph. Hook and absorption measurements are presented, and radiative lifetimes are derived from log gf values. Comparison of the present values with previous results indicates only those of Bell et al. (1966) and Lennard et al. (1975) to consistently agree with the data presented, although the reliability laser-excitation technique of lifetime measurement is supported over that of Hanle methods.

Huber, M. C. E.↗

Imaging a terahertz superfluid plasmon in a two-dimensional superconductor

The superconducting gap defines the fundamental energy scale for the emergence of dissipationless transport and collective phenomena in a superconductor. In layered high-temperature cuprate superconductors, in which the Cooper pairs are confined to weakly coupled two-dimensional (2D) copper–oxygen (CuO 2 ) planes, terahertz (THz) spectroscopy at subgap millielectronvolt (meV) energies has provided crucial insights into the collective superfluid response perpendicular to the superconducting layers. However, within the CuO 2 planes, the collective superfluid response manifests as plasmonic charge oscillations at energies far exceeding the superconducting gap, obscured by strong dissipation. Here, in this study, we present spectroscopic evidence of a below-gap, 2D superfluid plasmon in few-layer Bi 2 Sr 2 CaCu 2 O 8+x and spatially resolve its deeply subdiffractive THz electrodynamics. By placing the superconductor in the near field of a spintronic THz emitter, we reveal this distinct resonance—absent in bulk samples and observed only in the superconducting phase—and determine its plasmonic nature by mapping the geometric anisotropy and dispersion. Crucially, these measurements offer a direct view of the momentum-dependent and frequency-dependent superconducting transition in two dimensions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tool Chain for Simulations of Bi-Filar Coil Winding for Fast Quench Protection

The advancement of high-field magnets utilizing high-temperature superconductors (HTS) brings about complex challenges, especially in quench detection and protection. Traditional methods often fall short due to the inherently slow quench propagation in HTS materials. One promising approach to overcome this involves using a bifilar winding configuration, where two conductors are placed side by side. Under normal operation, they function in series, but during a quench event, they switch to an anti-parallel mode. This shift reduces the differential inductance of the coil to near zero, enabling rapid current oscillations through a capacitor discharge. The resulting high-frequency current flow leads to swift, uniform heating, triggering a full-coil quench within microseconds. Moreover, the strong mutual coupling between the two windings significantly reduces electrical noise in voltage measurements. In this work, we explore the viability of this concept by designing, constructing, and testing a REBCO bifilar racetrack coil in liquid nitrogen. We also present a validated simulation model that closely mirrors the coil's dynamic behavior under these conditions, aligning well with experimental observations.

Jayathilaka, Rehan [Northern Illinois U.]↗

Heat load measurements for the PIP-II pHB650 cryomodule

This study presents a brief overview of the 1st and 2nd phases and an in-depth analysis of the 3rd phase heat load testing performed on the pHB650 (prototype High Beta 650 MHz) cryomodule at PIP2IT (PIP-II Injector Test Facility), with a focus on both the results and the methodological advancements that have improved testing efficiency and accuracy. A key challenge identified in the testing campaign is the higher-than-expected heat loads observed in the first PIP-II (Proton Improvement Plan II) prototype cryomodules (pSSR1 and pHB650) tested at PIP2IT. Elevated heat loads are concerning given the fixed capacity of the PIP-II cryoplant that is currently being installed at Fermilab. However, understanding the sources of these elevated heat loads offers a critical opportunity to implement effective heat load mitigations on upcoming PIP-II cryomodules to stay within the available capacity of the PIP-II cryoplant. The study includes a summary of test results, descriptions of measurement procedures, and key observations on parameters directly and indirectly related to heat load measurements. Direct observations include measured heat loads and the effectiveness of JT heat exchanger under varying conditions, while indirect observation analyze factors such as the temperature distribution on the two-phase pipe and relief piping under varying conditions. Thermal acoustic oscillations (TAO) were identified during testing, which was mitigated by replacing the original G10 stem with a stainless steel stem equipped with wipers for the cryomodule cooldown valve. A major innovation during pHB650 Phase 3 testing was the development of an automated Python script to streamline data acquisition, analysis, and reporting of heat load results. This script automatically retrieved data from ACNET (Accelerator Control Network), performed heat load calculations, and generated detailed reports featuring plots and tables. This advancement significantly reduced manual labor and enhanced the thoroughness of data analysis compared to earlier campaigns. The heat load test reports were promptly uploaded to the electronic logbook shortly after each test, enabling rapid feedback and collaboration between the SRF and cryogenic teams. The heat load measurements included various components: HTTS (high-temperature thermal shield), LTTS (low-temperature thermal shield), 2K isothermal and non-isothermal heat loads. Results were recorded both within the cryomodule and between the bayonet can supply and return. Measurements were conducted under different operating conditions such as "standard", "linac", and "simulated dynamic". Additionally, HTTS and LTTS heat loads were calculated in real time, allowing for the tracking of thermal stability and identification of changes during testing, both in steady-state and transient conditions. The results of this testing campaign not only provide valuable insights into the performance of the pHB650 cryomodule but also highlight best practices and lessons learned that will inform future cryomodule testing at PIP2IT. These include adopting automated tools for data analysis, refining real-time measurement capabilities, and emphasizing detailed pre-test planning. The framework established in this campaign aims to set an improved standard for cryomodule testing and heat load reporting in future cryomodule test campaigns.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗

Unconventional solitonic high-temperature superfluorescence from perovskites

Fast thermal dephasing limits macroscopic quantum phenomena to cryogenic conditions and hinders their use at ambient temperatures. For electronic excitations in condensed media, dephasing is mediated by thermal lattice motion. Therefore, taming the lattice influence is essential for creating collective electronic quantum states at high temperatures. Although there are occasional reports of high-T c quantum effects across different platforms, it is unclear which lattice characteristics and electron–lattice interactions lead to macroscopically coherent electronic states in solids. Here we studied intensity fluctuations in the macroscopic polarization during the emergence of superfluorescence in a lead halide perovskite and showed that spontaneously synchronized polaronic lattice oscillations accompany collective electronic dipole emission. We further developed an effective field model and theoretically confirmed that exciton–lattice interactions lead to a new electronically and structurally entangled coherent extended solitonic state beyond a critical polaron density. The analysis shows a phase transition with two processes happening in tandem: incoherent disordered polaronic lattice deformations establish an order, while macroscopic quantum coherence among excitons simultaneously emerges. Recombination of excitons in this state culminates in superfluorescence at high temperatures. Our study establishes fundamental connections between the transient superfluorescence process observed after the impulsive excitation of perovskites and general equilibrium phase transitions achieved by thermal cooling. By identifying various electron–lattice interactions in the perovskite structure and their respective role in creating collectively coherent electronic effects in solids, our work provides unprecedented insight into the design and development of new materials that exhibit high-temperature macroscopic quantum phenomena.

36 MATERIALS SCIENCE↗

Effects of Temperature Fluctuations on Surface Mobility of Atomic Steps and Oxidation Dynamics in High-Temperature Alloys

In contrast to the traditional perspective that thermal fluctuations are insignificant in surface dynamics, here we report their influence on surface reaction dynamics. Using real-time low-energy electron microscopy imaging of NiAl(100) under both vacuum and O 2 atmospheres, we demonstrate that transient temperature variations substantially alter the direction of atom diffusion between the surface and bulk, leading to markedly different oxidation outcomes. During heating, substantial outward diffusion of atoms from the bulk to the surface results in step growth. Conversely, cooling induces considerable inward diffusion of adatoms, producing a distinct oxide morphology. In both scenarios, initially formed oxide islands impede local atomic step mobility, thereby increasing step length due to mass transfer between the surface and bulk, with atomic steps acting as adatom sinks during heating and sources during cooling. Furthermore, we show that this pinning effect on atomic step mobility can be mitigated by applying persistent temperature fluctuations. As a result, understanding these nuances is vital for accurately predicting and dynamically manipulating the performance of active materials in various chemical processes under transient thermal conditions.

36 MATERIALS SCIENCE↗

Scattering neutrinos, spin models, and permutations

We consider a class of Heisenberg all-to-all coupled spin models inspired by neutrino interactions in a supernova with N degrees of freedom. These models are characterized by a coupling matrix that is relatively simple in the sense that there are only a few, relative to N , nontrivial eigenvalues, in distinction to the classic Heisenberg spin-glass models, leading to distinct behavior in both the high-temperature and low-temperature regimes. When the momenta of the neutrinos are uniform and random in directions, we can calculate the large- N partition function for the quantum Heisenberg model. In particular, the high-temperature partition function predicts a non-Gaussian density of states, providing interesting counterexamples showing the limits of general theorems on the density of states for quantum spin models. We can repeat the same argument for classical Heisenberg models, also known as rotor models, and we find the high-temperature expansion is completely controlled by the eigenvalues of the coupling matrix, and again predicts non-Gaussian behavior for the density of states as long as the number of eigenvalues does not scale linearly with N . Indeed, we derive the amusing fact that these partition functions are essentially the generating function for counting permutations in the high-temperature regime. Finally, for the case relevant to neutrinos in a supernova, we identify the low-temperature phase as a unique state with the direction of the momenta of the neutrino dictating its coherent state in flavor-space, a state we dub the “flavor-momentum-locked” state. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A high-temperature wideband pressure transducer

A condenser microphone AM carrier system, which has been developed to measure pressure fluctuations at elevated temperatures, consists of the following components: a condenser microphone designed for operation at elevated temperatures; existing carrier electronics developed under two previous research grants but adapted to meet present requirements; a 6 m cable operating as a half-wavelength transmission line between the microphone and carrier electronics; and a voltage-controlled oscillator used in a feedback loop for automatic tuning control. Both theoretical and practical aspects of the development program are considered. The three predominant effects of temperature changes are changes in the membrane-backplate gap, membrane tension, and air viscosity. The microphone is designed so that changes in gap and membrane tension tend to have compensating effects upon the microphone sensitivity.

Zuckerwar, A. J.↗

High-temperature microphone system

Pressure fluctuations in air or other gases in an area of elevated temperature are measured using a condenser microphone located in the area of elevated temperature and electronics for processing changes in the microphone capacitance located outside the area the area and connected to the microphone by means of high-temperature cable assembly. The microphone includes apparatus for decreasing the undesirable change in microphone sensitivity at high temperatures. The high temperature cable assembly operates as a half-wavelength transmission line in an AM carrier system and maintains a large temperature gradient between the two ends of the cable assembly. The processing electronics utilizes a voltage controlled oscillator for automatic tuning thereby increasing the sensitivity of the measuring apparatus.

Zuckerwar, A. J.↗

Characterization of devices, circuits, and high-temperature superconductor transmission lines by electro-optic testing

The development of a capability for testing transmission lines, devices, and circuits using the optically-based technique of electro-optics sampling was the goal of this project. Electro-optic network analysis of a high-speed device was demonstrated. The project involved research on all of the facets necessary in order to realize this result, including the discovery of the optimum electronic pulse source, development of an adequate test fixture, improvement of the electro-optic probe tip, and identification of a device which responded at high frequency but did not oscillate in the test fixture. In addition, during the process of investigating patterned high-critical-temperature superconductors, several non-contacting techniques for the determination of the transport properties of high T(sub c) films were developed and implemented. These are a transient, optical pump-probe, time-resolved reflectivity experiment, an impulsive-stimulated Raman scattering experiment, and a terahertz-beam coherent-spectroscopy experiment. The latter technique has enabled us to measure both the complex refractive index of an MgO substrate used for high-T(sub c) films and the complex conductivity of a YBa2Cu3O(7-x) sample. This information was acquired across an extremely wide frequency range: from the microwave to the submillimeter-wave regime. The experiments on the YBCO were conducted without patterning of, or contact to, the thin film. Thus, the need for the more difficult transmission-line experiments was eliminated. Progress in all of these areas was made and is documented in a number of papers. These papers may be found in the section listing the abstracts of the publications that were issued during the course of the research.

Whitaker, John F.↗