Search NASA⌕ Search

SEARCH · Search NASA

Results for “high-temperature oscillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High-Temperature Superconducting/Ferroelectric Structures for Tunable Microwave Components

At the NASA Lewis Research Center, ferroelectric films, such as SrTiO3 and Ba(x)Sr(1-x)TiO3, are being used in conjunction with YBa2Cu3O(7-delta) high-temperature superconducting (HTS) thin films to fabricate tunable microwave components, such as filters, varactors, and local oscillators. These structures capitalize on the variation of the dielectric constant of the ferroelectric film upon the application of a dc electric field as well as on the low microwave losses exhibited by the high-temperature superconducting films relative to their conventional conductor counterparts. (For example, the surface resistance for a YBa2Cu3O(7-delta) thin film at 10 GHz and 77 K is more than two orders of magnitude lower than that of copper at the same frequency and temperature.) SrTiO3 and Ba(x)Sr(1-x)TiO3 films are used because their crystal structure and lattice parameters are similar to those of YBa2Cu3O(7-delta), thus enabling the growth of highly textured YBa2Cu3O(7-delta) films with high critical current densities on the underlying ferroelectric film, or alternatively, of highly textured ferroelectric film on the underlying YBa2Cu3O(7-delta) film. Our efforts have been concentrated so far in determining the deposition parameters required for optimal ferroelectric thin-film growth (i.e., maximum tunability and lowest loss) and in investigating different varactor configurations to determine which geometry is the most advantageous in terms of tunability, losses, and required bias for a given communication application. For example, we have observed that for optimized SrTiO3 films in a parallel plate capacitor, tunabilities of up to 47 percent and dissipation losses (tan d) of 0.05 are attainable at 1 MHz , 80 K, and within the 0- to 5-V bias range. In contrast, for an interdigital configuration, tunabilities of up to 70 percent and tan d ranging from 0.015 to 0.001 (depending on bias) have been observed at 1 MHz and 77 K within the 0- to 100-V bias range. Efforts are underway to use these results in developing tunable receiver front-end preselect filters as well as in low-phase noise, tunable local oscillators for K-band applications. These components represent a hitherto unavailable technology to meet the stringent performance requirements of foreseeable satellite and wireless communication systems (e.g., bandwidth, in-band insertion losses, out-of-band rejection, and noise, amongst others) in a more advantageous fashion than with currently available technology (e.g., dielectric-filled cavity and waveguide filters, and dielectric resonator oscillators). Prototypes of high-temperature superconducting/ferroelectric tunable components such as a low-phase noise K-band local oscillator, a preselect C-band filter, and a low-loss K-band phase shifter are under development at NASA Lewis.

Miranda, Felix A.↗

Oscillator strengths of ultraviolet Fe I lines from hook-method measurements on a furnace

The hook method, which makes use of anomalous dispersion, was employed to measure 107 absolute oscillator strengths of Fe I on a high-temperature furnace. The absolute scale was established before and after each run by recording the anomalous dispersion near a strong resonance line with accurately known f-value. The results cover three lines with wavelengths from 1934 to 1941 A, and 104 lines lying between 2084 and 3194 A - mostly transitions originating from the a 5 D ground state. The average error of the f-values is plus or minus 20%, and the largest and smallest errors given are plus or minus 10 and plus or minus 60%. Disagreements exceeding an order of magnitude are found with previous values in the literature.

Banfield, F. P.↗

Particle kinetic simulation of high altitude hypervelocity flight

Rarefied flows about hypersonic vehicles entering the upper atmosphere or through nozzles expanding into a near vacuum may only be simulated accurately with a direct simulation Monte Carlo (DSMC) method. Under this grant, researchers enhanced the models employed in the DSMC method and performed simulations in support of existing NASA projects or missions. DSMC models were developed and validated for simulating rotational, vibrational, and chemical relaxation in high-temperature flows, including effects of quantized anharmonic oscillators and temperature-dependent relaxation rates. State-of-the-art advancements were made in simulating coupled vibration-dissociation recombination for post-shock flows. Models were also developed to compute vehicle surface temperatures directly in the code rather than requiring isothermal estimates. These codes were instrumental in simulating aerobraking of NASA's Magellan spacecraft during orbital maneuvers to assess heat transfer and aerodynamic properties of the delicate satellite. NASA also depended upon simulations of entry of the Galileo probe into the atmosphere of Jupiter to provide drag and flow field information essential for accurate interpretation of an onboard experiment. Finally, the codes have been used extensively to simulate expanding nozzle flows in low-power thrusters in support of propulsion activities at NASA-Lewis. Detailed comparisons between continuum calculations and DSMC results helped to quantify the limitations of continuum CFD codes in rarefied applications.

Boyd, Iain↗

Particle kinetic simulation of high altitude hypervelocity flight

Rarefied flows about hypersonic vehicles entering the upper atmosphere or through nozzles expanding into a near vacuum may only be simulated accurately with a direct simulation Monte Carlo (DSMC) method. Under this grant, researchers enhanced the models employed in the DSMC method and performed simulations in support of existing NASA projects or missions. DSMC models were developed and validated for simulating rotational, vibrational, and chemical relaxation in high-temperature flows, including effects of quantized anharmonic oscillators and temperature-dependent relaxation rates. State-of-the-art advancements were made in simulating coupled vibration - dissociation - recombination for post-shock flows. Models were also developed to compute vehicle surface temperatures directly in the code rather than requiring isothermal estimates. These codes were instrumental in simulating aerobraking of NASA's Magellan spacecraft during orbital maneuvers to assess heat transfer and aerodynamic properties of the delicate satellite. NASA also depended upon simulations of entry of the Galileo probe into the atmosphere of Jupiter to provide drag and flow field information essential for accurate interpretation of an onboard experiment. Finally, the codes have been used extensively to simulate expanding nozzle flows in low-power thrusters in support of propulsion activities at NASA-Lewis. Detailed comparisons between continuum calculations and DSMC results helped to quantify the limitations of continuum CFD codes in rarefied applications.

Boyd, Iain↗

Influence of damping on quantum interference - An exactly soluble model

This paper reports the result of a calculation which shows the effect of damping on the quantum interference of two Gaussian wave packets in a harmonic potential. The influence-functional method, which seems to be the most appropriate one for this kind of calculation, is used. It is shown that quantum-interference effects are severely diminished by the presence of damping even when its influence on the system is only light. The corrections to the undamped formulas are always expressible in terms of the phenomenological damping constant, the temperature (in the high-temperature limit), the cutoff frequency of the reservoir oscillators, and the mean number of quanta of energy intially present in the system. Both weakly and strongly damped systems are analyzed in the regime of low and high temperatures.

Caldeira, A. O.↗

Oscillator strengths of Cr I lines lying between 200 and 541 nm from hook-method and absorption measurements in a furnace

Measurements of 148 oscillator strengths of neutral chromium transitions were made on Cr vapor in a high-temperature furnace by the hook and absorption methods for strong and weak lines, respectively. With the aid of a 5D-z 5F0 multiplet, the product of the oscillator strengths of the lines of this multiplet with the column densities of their respective lower levels could be determined, and by using estimated oscillator strengths for these lines, all data could be put on a common relative scale. This scale was altered so that the results were matched with relative emission intensities. Results are compared with other authors' results. A correction to the hook method constant was also determined.

Huber, M. C. E.↗

High-Temperature Superconducting/Ferroelectric, Tunable Thin-Film Microwave Components

At the NASA Lewis Research Center, ferroelectric films such as SrTiO3 and Ba(sub x)Sr(sub 1-x)TiO3, are being used in conjunction with YBa(sub 2)Cu(sub 3)O(sub 7-delta) high-temperature superconducting thin films to fabricate tunable microwave components such as filters, phase shifters, and local oscillators. These structures capitalize on the variation of the dielectric constant of the ferroelectric film upon the application of a direct-current electric field, as well as on the low microwave losses of high-temperature superconductors relative to their conventional conductor counterparts. For example, the surface resistance for a YBa(sub 2)Cu(sub 3)O(sub 7-delta) thin film at 10 GHz and 77 K is more than two orders of magnitude lower than that of copper or gold at the same temperature and frequency. SrTiO3 and Ba(sub x)Sr(sub 1-x)TiO3 films are used because their crystal structure and lattice parameters are similar to those of YBa(sub 2)Cu(sub 3)O(sub 7-delta), thus enabling the growth of highly textured YBa(sub 2)Cu(sub 3)O(sub 7-delta) films with high critical current densities (i.e., greater than 1 MA/sq cm) on the underlying ferroelectric film, or alternatively, of highly textured ferroelectric film on the underlying YBa(sub 2)Cu(sub 3)O(sub 7-delta) film.

Miranda, Felix A.↗

Internal and surface phenomena in metal combustion

Combustion of metals has been widely studied in the past, primarily because of their high oxidation enthalpies. A general understanding of metal combustion has been developed based on the recognition of the existence of both vapor-phase and surface reactions and involvement of the reaction products in the ensuing heterogeneous combustion. However, distinct features often observed in metal particle combustion, such as brightness oscillations and jumps (spearpoints), disruptive burning, and non-symmetric flames are not currently understood. Recent metal combustion experiments using uniform high-temperature metal droplets produced by a novel micro-arc technique have indicated that oxygen dissolves in the interior of burning particles of certain metals and that the subsequent transformations of the metal-oxygen solutions into stoichiometric oxides are accompanied with sufficient heat release to cause observed brightness and temperature jumps. Similar oxygen dissolution has been observed in recent experiments on bulk iron combustion but has not been associated with such dramatic effects. This research addresses heterogeneous metal droplet combustion, specifically focusing on oxygen penetration into the burning metal droplets, and its influence on the metal combustion rate, temperature history, and disruptive burning. A unique feature of the experimental approach is the combination of the microgravity environment with a novel micro-arc Generator of Monodispersed Metal Droplets (GEMMED), ensuring repeatable formation and ignition of uniform metal droplets with controllable initial temperature and velocity. The droplet initial temperatures can be adjusted within a wide range from just above the metal melting point, which provides means to ignite droplets instantly upon entering an oxygen containing environment. Initial droplet velocity will be set equal to zero allowing one to organize metal combustion microgravity experiments in a fashion similar to usual microgravity liquid fuel droplet combustion studies. In addition, the internal compositions of rapidly quenched metal particles will be analyzed using SEM technique. Such compositions are similar to those existing during the combustion and provide new insight on metal combustion processes. The results of this experimental work will be used to model the fundamental mechanisms of metal combustion. Preliminary experimental results on Al and Zr particle combustion at normal gravity are discussed here.

Dreizin, Edward L.↗

Low-cost FM oscillator for capacitance type of blade tip clearance measurement system

The frequency-modulated (FM) oscillator described is part of a blade tip clearance measurement system that meets the needs of a wide class of fans, compressors, and turbines. As a result of advancements in the technology of ultra-high-frequency operational amplifiers, the FM oscillator requires only a single low-cost integrated circuit. Its carrier frequency is 42.8 MHz when it is used with an integrated probe and connecting cable assembly consisting of a 0.81 cm diameter engine-mounted capacitance probe and a 61 cm long hermetically sealed coaxial cable. A complete circuit analysis is given, including amplifier negative resistance characteristics. An error analysis of environmentally induced effects is also derived, and an error-correcting technique is proposed. The oscillator can be calibrated in the static mode and has a negative peak frequency deviation of 400 kHz for a rotor blade thickness of 1.2 mm. High-temperature performance tests of the probe and 13 cm of the adjacent cable show good accuracy up to 600 C, the maximum permissible seal temperature. The major source of error is the residual FM oscillator noise, which produces a clearance error of + or - 10 microns at a clearance of 0.5 mm. The oscillator electronics accommodates the high rotor speeds associated with small engines, the signals from which may have frequency components as high as 1 MHz.

Barranger, John P.↗

Oscillator strengths of ultraviolet Ni I lines from hook-method and absorption measurements in a furnace

Measurements of the oscillator strengths of the ultraviolet lines of neutral nickel obtained by the use of the combined hook and absorption technique are reported. A total of 221 transitions in the range 1964-4094 A was measured for nickel atoms from a high-temperature graphite furnace (2000-2500 K) using a continuum background source, a Mach-Zehnder interferometer and a 3-m Czerny-Turner spectrograph. Hook and absorption measurements are presented, and radiative lifetimes are derived from log gf values. Comparison of the present values with previous results indicates only those of Bell et al. (1966) and Lennard et al. (1975) to consistently agree with the data presented, although the reliability laser-excitation technique of lifetime measurement is supported over that of Hanle methods.

Huber, M. C. E.↗

Sandwich-Geometry YBa(2)Cu(3)O(7-delta)/Au/Nb SNS Devices

Superconductor/normal-conductor/superconductor (SNS) devices in which electronically active layers consist of high-temperature superconductor YBa(2)Cu(3)O(7-delta), normal conductor Au, and conventional superconductor Nb, fabricated in sandwich geometry. Devices and processes by which fabricated are part of continuing effort to develop SNS microbridges for use in superconducting quantum interference devices (SQUIDS's) or as mixers or local oscillators operating at frequencies of hundreds of gigahertz. Results show promise for manufacture of practical devices.

Foote, Marc C.↗

A high-temperature wideband pressure transducer

A condenser microphone AM carrier system, which has been developed to measure pressure fluctuations at elevated temperatures, consists of the following components: a condenser microphone designed for operation at elevated temperatures; existing carrier electronics developed under two previous research grants but adapted to meet present requirements; a 6 m cable operating as a half-wavelength transmission line between the microphone and carrier electronics; and a voltage-controlled oscillator used in a feedback loop for automatic tuning control. Both theoretical and practical aspects of the development program are considered. The three predominant effects of temperature changes are changes in the membrane-backplate gap, membrane tension, and air viscosity. The microphone is designed so that changes in gap and membrane tension tend to have compensating effects upon the microphone sensitivity.

Zuckerwar, A. J.↗

High-temperature microphone system

Pressure fluctuations in air or other gases in an area of elevated temperature are measured using a condenser microphone located in the area of elevated temperature and electronics for processing changes in the microphone capacitance located outside the area the area and connected to the microphone by means of high-temperature cable assembly. The microphone includes apparatus for decreasing the undesirable change in microphone sensitivity at high temperatures. The high temperature cable assembly operates as a half-wavelength transmission line in an AM carrier system and maintains a large temperature gradient between the two ends of the cable assembly. The processing electronics utilizes a voltage controlled oscillator for automatic tuning thereby increasing the sensitivity of the measuring apparatus.

Zuckerwar, A. J.↗

Characterization of devices, circuits, and high-temperature superconductor transmission lines by electro-optic testing

The development of a capability for testing transmission lines, devices, and circuits using the optically-based technique of electro-optics sampling was the goal of this project. Electro-optic network analysis of a high-speed device was demonstrated. The project involved research on all of the facets necessary in order to realize this result, including the discovery of the optimum electronic pulse source, development of an adequate test fixture, improvement of the electro-optic probe tip, and identification of a device which responded at high frequency but did not oscillate in the test fixture. In addition, during the process of investigating patterned high-critical-temperature superconductors, several non-contacting techniques for the determination of the transport properties of high T(sub c) films were developed and implemented. These are a transient, optical pump-probe, time-resolved reflectivity experiment, an impulsive-stimulated Raman scattering experiment, and a terahertz-beam coherent-spectroscopy experiment. The latter technique has enabled us to measure both the complex refractive index of an MgO substrate used for high-T(sub c) films and the complex conductivity of a YBa2Cu3O(7-x) sample. This information was acquired across an extremely wide frequency range: from the microwave to the submillimeter-wave regime. The experiments on the YBCO were conducted without patterning of, or contact to, the thin film. Thus, the need for the more difficult transmission-line experiments was eliminated. Progress in all of these areas was made and is documented in a number of papers. These papers may be found in the section listing the abstracts of the publications that were issued during the course of the research.

Whitaker, John F.↗

A new test machine for measuring friction and wear in controlled atmospheres to 1200 C

This paper describes a new high-temperature friction and wear test apparatus (tribometer). The tribometer can be used as a pin-on-disk or pin-on-ring configuration and is specially designed to measure the tribological properties of ceramics and high temperature metallic alloys from room temperature to 1200 C. Sliding mode can be selected to be either unidirectional at velocities up to 22 m/sec or oscillating at frequencies up to 4.6 Hz and amplitudes up to + or - 60 deg. The test atmosphere is established by a controlled flow rate of a purge gas. All components within the test chamber are compatible with oxidizing, inert or reducing gases.

Sliney, Harold E.↗