Search NASA⌕ Search

SEARCH · Search NASA

Results for “hot liquid water”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Icing Sensor Probe

Aircraft icing is a serious safety problem for the general aviation and some commuter transport airplanes. There has been tremendous growth in the commuter aviation industry in the last few years, Since these type of aircraft generally operate at lower altitudes they consequently spend a far greater proportion of their time operating in icing conditions. For the past thirty years airborne and ground based facilities have relied primarily on two types of cloud physics instrumentation to measure the characteristics of icing clouds: hot wire liquid water content probes and laser based particle sizing probes for the measurement of water droplet size. The instrumentation is severely limited by the technology that was developed during the 1970's and is quite large in size. The goal of this research is to develop one instrument with a wide bandwidth, better response time, higher resolution, user selectability, and small and lightweight. NASA Glenn Research Center, Droplet Measurement Technology, and Meteorology Society of Canada have developed a collaborative effort to develop such an instrument. This paper describes the development and test results of the prototype Icing Sensor Probe.

Emery, Edward↗

Properties of cirrus generating cells.

Particle size spectra were measured during 20 hr of sampling in cirrus generating cells (uncinus, stratus, spissatus, thunderstorm anvil) and the particle concentration, mean crystal length, ice water content, reflectivity factor, and precipitation rate were calculated from these spectra. Average values of the physical properties in the generating cells were obtained. Growth was found to be downward, reaching a maximum ice water content just below the base of the generating cell. The maximum ice water contents (not including the thunderstorm anvil) were found in cirrus uncinus. Liquid water was not found throughout the cirrus sampling by measurement with the Johnson-Williams hot-wire liquid-water meter; however, it is believed that liquid water is present as a transient phase.

Heymsfield, A. J.↗

Solar heating and hot water system installed at Southeast of Saline, Unified School District 306, Mentor, Kansas

The solar system, installed in a new building, was designed to provide 52 percent of the estimated annual space heating load and 84 percent of the estimated annual potable hot water requirement. The liquid flat plate collectors are ground-mounted and cover a total area of 5125 square feet. The system will provide supplemental heat for the school's closed-loop water-to-air heat pump system and domestic hot water. The storage medium is water inside steel tanks with a capacity of 11,828 gallons for space heating and 1,600 gallons for domestic hot water. The solar heating facility is described and drawings are presented of the completed system which was declared operational in September 1978, and has functioned successfully since.

Source record↗

Solar hot water system installed at Day's Inn Motel, Savannah, Georgia

The Solar System was designed to provide 50 percent of the total Domestic Hot Water (DHW) demand. Liquid Flat Plate Collectors (900 square feet) are used for the collector subsystem. The collector subsystem is closed loop, using 50 percent Ethylene Glycol solution antifreeze for freeze protection. The 1,000 gallon fiber glass storage tank contains two heat exchangers. One of the heat exchangers heats the storage tank with the collector solar energy. The other heat exchanger preheats the cold supply water as it passes through on the way to the Domestic Hot Water (DHW) tank heaters. Electrical energy supplements the solar energy for the DHW. The Collector Mounting System utilizes guy wires to structurally tie the collector array to the building.

Source record↗

Effects of entrained water and strong turbulence on afterburning within solid rocket motor plumes

During the first few seconds of the space shuttle trajectory, the solid rocket boosters will be in the proximity of the launch pad. Because of the launch pad structures and the surface of the earth, the turbulent mixing experienced by the exhaust gases will be greatly increased over that for the free flight situation. In addition, a system will be present, designed to protect the lifting vehicle from launch structure vibrations, which will inject quantities of liquid water into the hot plume. The effects of these two phenomena on the temperatures, chemical composition, and flow field present in the afterburning solid rocket motor exhaust plumes of the space shuttle were studied. Results are included from both a computational model of the afterburning and supporting measurements from Titan 3 exhaust plumes taken at Kennedy Space Center with infrared scanned radiometers.

Gomberg, R. I.↗

System Design Package for SIMS Prototype System 3, Solar Heating and Domestic Hot Water

A collation of documents and drawings are presented that describe a prototype solar heating and hot water system using liquid flat plate collectors and a gas or electric furnace energy subsystem. The system was designed for installation into a single-family dwelling. The description, performance specification, subsystem drawings, verification plan/procedure, and hazard analysis of the system are packaged for evaluation of the system with information sufficient to assemble a similar system.

Source record↗

Mass and density of the transiting hot and rocky super-EarthLHS 1478 b (TOI-1640 b)

One of the main objectives of the Transiting Exoplanet Survey Satellite (TESS) mission is the discovery of small rocky planets around relatively bright nearby stars. Here, we report the discovery and characterization of the transiting super-Earth planet orbiting LHS 1478 (TOI-1640). The star is an inactive red dwarf (J∼9.6mag and spectral type m3 V) with mass and radius estimates of 0.20±0.01 M and 0.25±0.01R, respectively, and an effective temperature of 3381±54K. It was observed by TESS in four sectors. These data revealed a transit-like feature with a period of 1.949 days. We combined the TESS data with three ground-based transit measurements, 57 radial velocity (RV) measurements from CARMENES, and 13 RV measurements from IRD, determining that the signal is produced by a planet with a mass of 2.33+0.20−0.20M and a radius of 1.24+0.05−0.05R. The resulting bulk density of this planet is 6.67 g cm−3, which is consistent with a rocky planet with an Fe- and MgSiO3-dominated composition. Although the planet would be too hot to sustain liquid water on its surface (its equilibrium temperature is about ∼595 K, suggesting a Venus-like atmosphere), spectroscopic metrics based on the capabilities of the forthcomingJames WebbSpace Telescope and the fact that the host star is rather inactive indicate that this is one of the most favorable known rocky exoplanets for atmospheric characterization.

M. G. Soto↗

Solar hot water system installed at Days Inn Motel, Jacksonville, Florida

The solar system was designed to provide 65 percent of the hot water demand. Water in the liquid flat plate collector (900 square feet) system automatically drains into the 1000 gallon lined and vented steel storage tank when the pump is not running. Heat is transferred from storage to Domestic Hot Water (DHW) tanks through a tube and shell heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up DHW standby losses. All pumps are controlled by differential temperature.

Source record↗

Heat transfer to two-phase air/water mixtures flowing in small tubes with inlet disequilibrium

The cooling of gas turbine components was the subject of considerable research. The problem is difficult because the available coolant, compressor bleed air, is itself quite hot and has relatively poor thermophysical properties for a coolant. Injecting liquid water to evaporatively cool the air prior to its contact with the hot components was proposed and studied, particularly as a method of cooling for contingency power applications. Injection of a small quantity of cold liquid water into a relatively hot coolant air stream such that evaporation of the liquid is still in process when the coolant contacts the hot component was studied. No approach was found whereby heat transfer characteristics could be confidently predicted for such a case based solely on prior studies. It was not clear whether disequilibrium between phases at the inlet to the hot component section would improve cooling relative to that obtained where equilibrium was established prior to contact with the hot surface.

Janssen, J. M.↗

Comets, Asteroids, Meteorites, and the Origin of the Biosphere

During the past few decades, the delivery of water, organics, and prebiotic chemicals to the Biosphere of Earth during the Hadean (4.5-3.8 Ga) period of heavy bombardment by comets and asteroids has become more widely accepted. Comets are still largely regarded as frigid, pristine bodies of protosolar nebula material that are devoid of liquid water and therefore unsuitable for life. Complex organic compounds have been observed in comets and on the water-rich asteroid 1998 KY26 and near IR observations have indicated the presence of crystalline water ice and ammonia hydrate on the large Kuiper Belt object (50000) Quaoar that has resurfacing suggesting cryovolcanic outgassing. Spacecraft observations of the chemical compositions and characteristics of the nuclei of several comets (Halley, Borrelly, Wild 2, and Tempel 1) have shown that comets contain complex organic chemicals; that water is the predominant volatile; and that extremely high temperatures (approx. 350-400 K) can be reached on the surfae of the very black (albedo approx. 0.03) nuclei of comets when they approach the Sun. Impact craters and pinnacles observed on comet Wild 2 suggest a thick crust. Episodic outbursts and jets from the nuclei of several comets indicate that localized regimes of liquid water and water vapor can periodically exist beneath the comet crust. The Deep Impact mission found the temperature of the nucleus of comet Tempel 1 at 1.5 AU varied from a minimum of 280 plus or minus 8 K the 330K (57 C) on the sunlit side. In this paper it is argued that that pools and films of liquid water exist (within a wide range of temperatures) in cavities and voids just beneath the hot, black crust. The possibility of liquid water existing over a wide range of temperatures significantly enhances the possibility that comets might contain niches suitable for the growth of microbial communities and ecosystems. These regimes would be ideal for the growth of psychrophilic, mesophilic, and thermophilic photoautotrophs and chemolithotrophs such as the motile filamentous cyanobacteria (e.g., Calothrix, Oscillatoria, Phormidium, and Spirulina) that grow in geothermal springs and geysers of Earth at temperatures ranging fiom 320K to 345K and are also found growing in cold polar desert soils. The mineralized remains of morphotypes of all of these cyanobacteria have also been found in the Orgueil CI1 and the Murchison CN2 carbonaceous meteorites that may derive from cometary parent bodies. Observational results that support the hypothesis that liquid water can in active regions just beneath the surface of comets and that comets, carbonaceous meteorites, and asteroids may have played a significant role in the origin and evolution of the Biosphere and in the distribution of microbial life throughout the Solar System.

Hoover, Richard B.↗

Solar hot water system installed at Day's Inn Motel, Dallas, Texas (Valley View)

The solar system was designed to provide 65 percent of the total domestic hot water (DHW) demand. A liquid (water) flat plate collector (1,000 square feet) system automatically drains into the 1,000 gallon steel storage tank when the solar pump is not running. Heat is transferred from the DHW tanks through a shell and tube heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up standby losses. All pumps are controlled by differential temperature controllers.

Source record↗

Solar hot water system installed at Days Inn Motel, Dallas, Texas (Forrest Lane)

The solar system was designed to provide 65 percent of the total Domestic Hot Water (DHW) demand. The liquid flat plate (water) collector (1,000 square feet) system automatically drains into the 1,000 gallon steel storage tank located in the mechanical room when the pump is not running. Heat is transferred from the storage tank to DHW tanks through a tube and shell heat exchanger. A circulating pump between the DHW tanks and the heat exchanger enables solar heated water to help make DHW tank standby losses. All pumps are controlled by differential temperature.

Source record↗

Extraterrestrial Amino Acids and Amines Identified in Asteroid Ryugu Samples Returned By the Hayabusa2 Mission

The hot water and acid extracts of two different Ryugu samples collected by the Hayabusa2 mission were analyzed for the presence of aliphatic amines and amino acids. The abundances and relative distributions of both classes of molecules were determined, as well as the enantiomeric compositions of the chiral amino acids. The Ryugu samples studied here were recovered from sample chambers A and C, which were composed of surface material, and a combination of surface and possible subsurface material, respectively. A total of thirteen amino acids were detected and quantitated in these samples, with an additional five amino acids that were tentatively identified but not quantitated. The abundances of four aliphatic amines identified in the Ryugu samples were also determined in the current work. Amino acids were observed in the acid hydrolyzed and unhydrolyzed hot water extracts of asteroid Ryugu regolith using liquid chromatography with UV fluorescence detection and high-resolution mass spectrometry. Conversely, aliphatic amines were only analyzed in the unhydrolyzed hot water Ryugu extracts. Two- to six-carbon (C 2 -C 6 ) amino acids with individual abundances ranging from 0.02 to 15.8 nmol g −1 , and one- to three-carbon (C 1 -C 3 ) aliphatic amines with individual abundances from 0.05 to 34.14 nmol g −1 , were found in the hot water extracts. Several non-protein amino acids that are rare in biology, including β-amino-n-butyric acid (β-ABA) and β-aminoisobuytric acid (β-AIB), were racemic or very nearly racemic, thus indicating their likely abiotic origins. Trace amounts of select protein amino acids that were enriched in the ւ-enantiomer may indicate low levels of terrestrial amino acid contamination in the samples. However, the presence of elevated abundances of free and racemic alanine, a common protein amino acid in terrestrial biology, and elevated abundances of the predominately free and racemic non-protein amino acids, β-ABA and β-AIB, indicate that many of the amino acids detected in the Ryugu water extracts were indigenous to the samples. Although the Ryugu samples have been found to be chemically similar to CI type carbonaceous chondrites, the measured concentrations and relative distributions of amino acids and aliphatic amines in Ryugu samples were notably different from those previously observed for the CI1.1 carbonaceous chondrite, Orgueil. This discrepancy could be the result of differences in the original chemical compositions of the parent bodies and/or alteration conditions, such as space weathering. In addition to α-amino acids that could have been formed by Strecker cyanohydrin synthesis during a low temperature aqueous alteration phase, β-, γ-, and δ-amino acids, including C 3 – C 5 straight-chain n-ω-amino acids that are not formed by Strecker synthesis, were also observed in the Ryugu extracts. The suite of amino acids measured in the Ryugu samples indicates that multiple amino acid formation mechanisms were active on the Ryugu parent body. The analytical techniques used here are well-suited to search for similar analytes in asteroid Bennu material collected by the NASA OSIRIS-REx mission scheduled for Earth return in September 2023.

Hayabusa2↗

Air-liquid solar collector for solar heating, combined heating and cooling, and hot water subsystems

A collection of quarterly reports consisting of the installation and layout design of the air collector system for commercial applications, completion of the preliminary design review, detailed design efforts, and preparation of the verification test plan are given. Performance specifications and performance testing of a prototype model of a two manifold, 144 tube air collector array is presented.

Source record↗

Instrument for Aircraft-Icing and Cloud-Physics Measurements

The figure shows a compact, rugged, simple sensor head that is part of an instrumentation system for making measurements to characterize the severity of aircraft-icing conditions and/or to perform research on cloud physics. The quantities that are calculated from measurement data acquired by this system and that are used to quantify the severity of icing conditions include sizes of cloud water drops, cloud liquid water content (LWC), cloud ice water content (IWC), and cloud total water content (TWC). The sensor head is mounted on the outside of an aircraft, positioned and oriented to intercept the ambient airflow. The sensor head consists of an open housing that is heated in a controlled manner to keep it free of ice and that contains four hot-wire elements. The hot-wire sensing elements have different shapes and sizes and, therefore, exhibit different measurement efficiencies with respect to droplet size and water phase (liquid, frozen, or mixed). Three of the hot-wire sensing elements are oriented across the airflow so as to intercept incoming cloud water. For each of these elements, the LWC or TWC affects the power required to maintain a constant temperature in the presence of cloud water.

Lilie, Lyle↗

Analytical ice shape predictions for flight in natural icing conditions

LEWICE is an analytical ice prediction code that has been evaluated against icing tunnel data, but on a more limited basis against flight data. Ice shapes predicted by LEWICE is compared with experimental ice shapes accreted on the NASA Lewis Icing Research Aircraft. The flight data selected for comparison includes liquid water content recorded using a hot wire device and droplet distribution data from a laser spectrometer; the ice shape is recorded using stereo photography. The main findings are as follows: (1) An equivalent sand grain roughness correlation different from that used for LEWICE tunnel comparisons must be employed to obtain satisfactory results for flight; (2) Using this correlation and making no other changes in the code, the comparisons to ice shapes accreted in flight are in general as good as the comparisons to ice shapes accreted in the tunnel (as in the case of tunnel ice shapes, agreement is least reliable for large glaze ice shapes at high angles of attack); (3) In some cases comparisons can be somewhat improved by utilizing the code so as to take account of the variation of parameters such as liquid water content, which may vary significantly in flight.

Berkowitz, Brian M.↗

Solar heating and hot water system installed at Cherry Hill, New Jersey

The solar heating and hot water system installed in existing buildings at the Cherry Hill Inn in Cherry Hill, New Jersey is described in detail. The system is expected to furnish 31.5% of the overall heating load and 29.8% of the hot water load. The collectors are liquid evacuated tube type. The storage system is an above ground insulated steel water tank with a capacity of 7,500 gallons.

Source record↗

Amino Acid Abundances and Compositions in Iron and Stony-Iron Meteorites

The organic compositions of carbonaceous chondrite meteorites have been extensively studied; however, there have been fewer reports of other meteorite classes, and almost none from iron meteorites, which contain much less carbon than carbonaceous chondrites but make up ~4% of observed meteorite falls. Here, we report the bulk amino acid content of three iron meteorites (Campo del Cielo, IAB; Canyon Diablo, IAB; and Cape York, IIIAB) and both the metal and silicate portions of a pallasite (Imilac). We developed a novel method to prepare the samples for analysis, followed by hot water extraction and analysis via liquid chromatography‐mass spectrometry. Free amino acid abundances ranging from 301 to 1216 pmol/g were observed in the meteorites, with the highest abundance in the silicate portion of the pallasite. Although some of the amino acid content could be attributed to terrestrial contamination, evidence suggests that some compounds are indigenous. A suite of C(5) amino acids was observed with a distinct distribution favoring a straight chain (n‐pentanoic acid) structure; this straight chain dominance is suggestive of that observed in thermally altered stony meteorites. Amino acids were also observed in terrestrial iron granules that were milled and analyzed in the same way as the meteorites, although the distribution of detected amino acids was different. It is possible that similar formation mechanisms existed in both the meteorites and the terrestrial iron, or that observed amino acids resulted from reactions of precursors during sample preparation. This work suggests that iron meteorites should not be overlooked for contributions of amino acids and likely other soluble organic molecules to the early Earth. Future studies of iron–nickel meteorites and asteroids, such as Psyche, may provide further insights into their potential organic inventory.

Jamie E. Elsila↗