Search NASA⌕ Search

SEARCH · Search NASA

Results for “htdma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

NCSU HTDMA data

NCSU HTDMA data Data Level b1: QC checks applied to measurements Data Format: CSV Description: See "instrument description Site: Houston, TX; Tracking Aerosol Convection interactions ExpeRiment (HOU) Location: Houston, TX; AMF1 (main site for TRACER) Facility Code: M1 Category: Aerosol Properties Data Type: PI Data Source Instrument/Data: Humidified Tandem Differential Mobility Analyzer; 2 Differential Mobility Analyzers (DMA1 and DMA2). Start Date: 2022-06-01 End Date: 2022-09-26 Contact PI: Markus Petters (mdpetter@ncsu.edu) Funding Source: DOE ASR award US Department of Energy, Office of Science, Biological and Environment Research (grant no. DE-SC 0021074) Instrument description The NCSU HTDMA was operated at a sheath-to-sample flow ratio of 5:1 L min−1. The HTDMA was configured to measure hygroscopic growth factors of dry particles with mobility diameters of D = 15, 20, 30, 40, and 50 nm at RH ~ 70%. A complete cycle for all diameters took ~30 minutes. A sample line brought aerosol inside the trailer at 2.5 L min-1, where it was distributed between NCSU RDMA (1.5 L min-1) and NCSU HTDMA (1 L min-1) lines. The sample line was dried with three silica-gel driers in series, and then neutralized with X-ray neutralizer. The sample line entered DMA1 (operated as an electrostatic classifier). Monodisperse particles with certain fractions were humidified with temperature controlled Nafion membrane immersed in water before entering DMA2 (operated in scanning mobility particle sizer). Please contact mdpetter@ncsu.edu for further information.

54 ENVIRONMENTAL SCIENCES↗

Revisiting matrix-based inversion of scanning mobility particle sizer (SMPS) and humidified tandem differential mobility analyzer (HTDMA) data

Abstract. Tikhonov regularization is a tool for reducing noise amplification during data inversion. This work introduces RegularizationTools.jl, a general-purpose software package for applying Tikhonov regularization to data. The package implements well-established numerical algorithms and is suitable for systems of up to ∼ 1000 equations. Included is an abstraction to systematically categorize specific inversion configurations and their associated hyperparameters. A generic interface translates arbitrary linear forward models defined by a computer function into the corresponding design matrix. This obviates the need to explicitly write out and discretize the Fredholm integral equation, thus facilitating fast prototyping of new regularization schemes associated with measurement techniques. Example applications include the inversion involving data from scanning mobility particle sizers (SMPSs) and humidified tandem differential mobility analyzers (HTDMAs). Inversion of SMPS size distributions reported in this work builds upon the freely available software DifferentialMobilityAnalyzers.jl. The speed of inversion is improved by a factor of ∼ 200, now requiring between 2 and 5 ms per SMPS scan when using 120 size bins. Previously reported occasional failure to converge to a valid solution is reduced by switching from the L-curve method to generalized cross-validation as the metric to search for the optimal regularization parameter. Higher-order inversions resulting in smooth, denoised reconstructions of size distributions are now included in DifferentialMobilityAnalyzers.jl. This work also demonstrates that an SMPS-style matrix-based inversion can be applied to find the growth factor frequency distribution from raw HTDMA data while also accounting for multiply charged particles. The outcome of the aerosol-related inversion methods is showcased by inverting multi-week SMPS and HTDMA datasets from ground-based observations, including SMPS data obtained at Bodega Marine Laboratory during the CalWater 2/ACAPEX campaign and co-located SMPS and HTDMA data collected at the US Department of Energy observatory located at the Southern Great Plains site in Oklahoma, USA. Results show that the proposed approaches are suitable for unsupervised, nonparametric inversion of large-scale datasets as well as inversion in real time during data acquisition on low-cost reduced-instruction-set architectures used in single-board computers. The included software implementation of Tikhonov regularization is freely available, general, and domain-independent and thus can be applied to many other inverse problems arising in atmospheric measurement techniques and beyond.

54 ENVIRONMENTAL SCIENCES↗

3002 Humidified Tandem Differential Mobility Analyzer (HTDMA) Instrument Handbook

The Brechtel Manufacturing Inc. (BMI) Humidified Tandem Differential Mobility Analyzer (HT-DMA Model 3002) (Brechtel and Kreidenweis 2000a,b, Henning et al. 2005, Xerxes et al. 2014) measures how aerosol particles of different initial dry sizes grow or shrink when exposed to changing relative humidity (RH) conditions. It uses two different mobility analyzers (DMA) and a humidification system to make the measurements. One DMA selects a narrow size range of dry aerosol particles, which are exposed to varying RH conditions in the humidification system. The second (humidified) DMA scans the particle size distribution output from the humidification system. Scanning a wide range of particle sizes enables the second DMA to measure changes in size or growth factor (growth factor = humidified size/dry size), due to water uptake by the particles. A Condensation Particle Counter (CPC) downstream of the second DMA counts particles as a function of selected size in order to obtain the number size distribution of particles exposed to different RH conditions.

54 ENVIRONMENTAL SCIENCES↗

Hygroscopic growth of UO 2 F 2 nanoparticles

Hygroscopicity is an important physicochemical property of aerosol that describes the ability of a particle to uptake water. The hygroscopic properties of uranyl fluoride (UO 2 F 2 ) aerosol generated from a UF 6 hydrolysis reactor was investigated for the first time using a custom-built Humidified Tandem Differential Mobility Analyzer (HTDMA). The HTDMA is capable of measuring UO 2 F 2 nanoparticle growth determined by mobility size over a wide range of atmospheric humidity from dry conditions at <10% relative humidity (RH) to 85% RH. The hygroscopic properties were determined for nanoparticles as small as 3.5 nm in this study. Although the largest size of UO 2 F 2 nanoparticles was 80 nm, monodisperse aerosol with a mobility diameter of up to approximately 500 nm can be investigated using the HTDMA. Anhydrous UO 2 F 2 nanoparticles with a mobility diameter of 3.5 nm were shown to be highly hygroscopic with a deliquescence relative humidity (DRH) of 10%. Hydrates with a larger mobility diameter from 10 to 80 nm were non-hygroscopic with no observable DRH and limited water uptake up to 85% RH. Here, these results demonstrate the hygroscopic properties of UO 2 F 2 nanoparticles are highly variable and based on both the mobility size and hydration state. Hygroscopicity affects the physicochemical properties of UO 2 F 2 nanoparticles, including the aerosol phase state and viscosity, with impacts on aerosol growth, coagulation, and deposition that is critical for understanding the fate and transport of UO 2 F 2 nanoparticles in the atmosphere.

Hygroscopicity↗

A novel methodology for assessing the hygroscopicity of aerosol filter samples

Abstract. Due to US regulations, concentrations of hygroscopic inorganic sulfate and nitrate have declined in recent years, leading to an increased importance of the hygroscopic nature of organic matter (OM). The hygroscopicity of OM is poorly characterized because only a fraction of the multitude of organic compounds in the atmosphere is readily measured, and there is limited information on their hygroscopic behaviors. Hygroscopicity of aerosol is traditionally measured using a humidified tandem differential mobility analyzer (HTDMA) or electrodynamic balance (EDB). EDB measures water uptake by a single particle. For ambient and chamber studies, HTDMA measurements provide water uptake and particle size information but not chemical composition. To fill this information gap, we developed a novel methodology to assess the water uptake by particles collected on Teflon filters. This method uses the same filter sample for both hygroscopicity measurements and chemical characterization, thereby providing an opportunity to link the measured hygroscopicity with ambient particle composition. To test the method, hygroscopic measurements were conducted in the laboratory for ammonium sulfate, sodium chloride, glucose, and malonic acid, which were collected on 25 mm Teflon filters using an aerosol generator and sampler. Constant-humidity solutions (CHSs), including potassium chloride, barium chloride dihydrate, and potassium sulfate, were employed in a saturated form to maintain the relative humidity (RH) at approximately 84 %, 90 %, and 97 % in small chambers. Our preliminary experiments revealed that, without the pouch, water uptake measurements were not feasible due to rapid water loss during weighing. Additionally, we observed some absorption by the aluminum pouch itself. To account for this, concurrent measurements were conducted for both the loaded and the blank filters at each RH level. Thus, the dry loaded and blank Teflon filters were placed in aluminum pouches with one side open and in RH-controlled chambers for more than 24 h. The wet loaded samples and wet blanks were then weighed using an ultramicrobalance to determine the water uptake by the respective compound and the blank Teflon filter. The net amount of water absorbed by each compound was calculated by subtracting the water uptake of the blank filter from that of the wet loaded filter. Hygroscopic parameters, including the water-to-solute (W / S) ratio, molality, mass fraction solute (mfs), and growth factors (GFs), were calculated from the measurements. The results obtained are consistent with those reported by the Extended Aerosol Inorganics Model (E-AIM) and previous studies utilizing HTDMA and EDB for these compounds, highlighting the accuracy of this new methodology. This new approach enables the hygroscopicity and chemical composition of individual filter samples to be assessed so that in complex mixtures, such as chamber and ambient samples, the total water uptake can be parsed between the inorganic and organic components of the aerosol.

54 ENVIRONMENTAL SCIENCES↗

Hygroscopic Growth of UO 2 F 2 Particles

Hygroscopicity is an important physicochemical property of aerosol that describes the ability of a particle to uptake water. The hygroscopic properties of uranyl fluoride (UO 2 F 2 ) aerosol generated from a UF 6 hydrolysis reactor was investigated for the first time using a custom-built Humidified Tandem Differential Mobility Analyzer (HTDMA). The HTDMA is capable of measuring UO 2 F 2 particle growth determined by mobility size over a wide range of atmospheric humidity from dry conditions at <10% relative humidity (RH) to 85% RH. The hygroscopic properties were determined for nanoparticles as small as 3.5 nm in this study. Anhydrous UO 2 F 2 particles with a mobility diameter of 3.5 nm were shown to be highly hygroscopic with a deliquescence relative humidity (DRH) of 10%. Hydrates with a larger mobility diameter of 10 to 80 nm were non-hygroscopic with no observable DRH and limited water uptake up to 85% RH. These results demonstrate the hygroscopic properties of UO 2 F 2 particles are highly variable and based on both the mobility size and hydration state. Hygroscopicity affects the physicochemical properties of UO 2 F 2 particles, including the aerosol phase state and viscosity, with impacts on aerosol growth, coagulation, and deposition that is critical for understanding the fate and transport of UO 2 F 2 particles in the atmosphere.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid measurement of RH-dependent aerosol hygroscopic growth using a humidity-controlled fast integrated mobility spectrometer (HFIMS)

Abstract. The ability of aerosol particles to uptake water (hygroscopic growth) is an important determinant of aerosol optical properties and radiative effects. Aerosol hygroscopic growth is traditionally measured by humidified tandem differential mobility analyzers (HTDMA), in which size-selected dry particles are exposed to elevated relative humidity (RH), and the size distribution of humidified particles is subsequently measured using a scanning mobility particle sizer. As a scanning mobility particle sizer can measure only one particle size at a time, HTDMA measurements are time consuming, and ambient measurements are often limited to a single RH level. Pinterich et al. (2017b) showed that fast measurements of aerosol hygroscopic growth are possible using a humidity-controlled fast integrated mobility spectrometer (HFIMS). In HFIMS, the size distribution of humidified particles is rapidly captured by a water-based fast integrated mobility spectrometer (WFIMS), leading to a factor of ∼10 increase in measurement time resolution. In this study we present a prototype HFIMS that extends fast hygroscopic growth measurements to a wide range of atmospherically relevant RH values, allowing for more comprehensive characterizations of aerosol hygroscopic growth. A dual-channel humidifier consisting of two humidity conditioners in parallel is employed such that aerosol RH can be quickly stepped among different RH levels by sampling from alternating conditioners. The measurement sequence is also optimized to minimize the transition time between different particle sizes. The HFIMS is capable of measuring aerosol hygroscopic growth of six particle diameters under five RH levels ranging from 20 % to 85 % (30 separate measurements) every 25 min. The performance of this HFIMS is characterized and validated using laboratory-generated ammonium sulfate aerosol standards. Measurements of ambient aerosols are shown to demonstrate the capability of HFIMS to capture the rapid evolution of aerosol hygroscopic growth and its dependence on both size and RH.

54 ENVIRONMENTAL SCIENCES↗

Particle Flux Measurements during TRACER (TRACER PFM) (Field Campaign Report)

The purpose of this campaign was to deploy an instrument payload collocated with a suite of in situ and remote-sensing aerosol instruments at the urban site at the La Porte, Texas Municipal Airport during the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Tracking Aerosol Convection Interactions Experiment (TRACER) in Houston, Texas. The payload was designed to characterize the physicochemical properties, mixing state, and size-resolved vertical fluxes of aerosols. Deployed aerosol instruments associated with the flux measurements included three condensation particle counters (CPCs) with different lower cutoff diameters ( D > 2.5 nm, D > 10 nm, and D > 40 nm), a single-particle soot photometer (SP2) measuring refractory black carbon, and a portable optical particle spectrometer (POPS) measuring the optical size distribution (~180 nm < D < ~5000 nm). A 10-m flux tower hosted a sonic anemometer (SONIC) for vertical velocity measurements. In addition, a humidified tandem differential mobility analyzer (HTDMA) was deployed to measure the growth factors and hygroscopicity parameter of 15-50 nm-sized particles in order to constrain the composition of compounds responsible for modal aerosol growth during new particle formation/growth events. Finally, a radial differential mobility analyzer (RDMA) was deployed to extend the size distribution measurement to 5 nm.

54 ENVIRONMENTAL SCIENCES↗

Regularized inversion of aerosol hygroscopic growth factor probability density function: application to humidity-controlled fast integrated mobility spectrometer measurements

Abstract. Aerosol hygroscopic growth plays an important role in atmospheric particle chemistry and the effects of aerosol on radiation and hence climate. The hygroscopic growth is often characterized by a growth factor probability density function (GF-PDF), where the growth factor is defined as the ratio of the particle size at a specified relative humidity to its dry size. Parametric, least-squares methods are the most widely used algorithms for inverting the GF-PDF from measurements of the humidified tandem differential mobility analyzer (HTDMA) and have been recently applied to the GF-PDF inversion from measurements of the humidity-controlled fast integrated mobility spectrometer (HFIMS). However, these least-squares methods suffer from noise amplification due to the lack of regularization in solving the ill-posed problem, resulting in significant fluctuations in the retrieved GF-PDF and even occasional failures of convergence. In this study, we introduce nonparametric, regularized methods to invert the aerosol GF-PDF and apply them to HFIMS measurements. Based on the HFIMS kernel function, the forward convolution is transformed into a matrix-based form, which facilitates the application of the nonparametric inversion methods with regularizations, including Tikhonov regularization and Twomey's iterative regularization. Inversions of the GF-PDF using the nonparameteric methods with regularization are demonstrated using HFIMS measurements simulated from representative GF-PDFs of ambient aerosols. The characteristics of reconstructed GF-PDFs resulting from different inversion methods, including previously developed least-squares methods, are quantitatively compared. The result shows that Twomey's method generally outperforms other inversion methods. The capabilities of Twomey's method in reconstructing the pre-defined GF-PDFs and recovering the mode parameters are validated.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of assumptions made by Hygroscopic Tandem Differential Mobility Analyzer inversion routines

The Hygroscopic Tandem Differential Mobility Analyzer (H-TDMA) measures the hygroscopicity of atmospheric particles, and many atmospheric processes that change this hygroscopicity also change the atmospheric size distribution. Two assumptions made during H-TDMA inversion create spurious hygroscopic trends as a function of the changing inlet size distribution. These two assumptions—that the particles exiting the first Differential Mobility Analyzer (DMA1) are singly charged and that the inlet size distribution has a slope of zero (flat)— generate Multi-Charge Dispersion (MCD) bias and Slope bias, respectively. First, we use a model, named TAO, to show that the inlet size distribution could theoretically change the measured ammonium sulfate hygroscopicity by 10%–20% as a function of diameter or experimental time with no change in relative humidity. Secondly, we show experimentally that aerosol emitted from the flaming combustion of grass creates MCD bias. Here, in this experiment, we measure the CPC response of the first three charges and invert these responses using a new routine named Junior. Junior's inversion of each charge shows that one growth factor distribution describes all measured diameters (no growth dependence on diameter). As in the modeling study above, previous publications of this aerosol system, using traditional inversion assumptions, report a decrease in hygroscopicity as DMA1 diameter increases. Unlike traditional inversions, Junior's inversion does not assume the particles are singly charged nor does it make the flat inlet size distribution assumption. Instead, both the inlet size distribution and each charge's CPC response are measured quantities. Thus, the discrepancy between our inversion results and previous publications is likely due to the traditional inversion routine assumptions. This underscores the importance for accounting for Slope and MCD bias during inversions. Experimental results should be carefully analyzed when reporting hygroscopic trends with respect to diameter or experimental time when using the traditional inversion assumptions.

42 ENGINEERING↗