Search NASASearch

SEARCH · Search NASA

Results for “humidity measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Humidity Measurements at NASA Glenn Research Center Wind Tunnels

This presentation reviews the humidity measurements systems used at the large-scale wind tunnels at the NASA Glenn Research Center (as of July 2023), including the 9- by 15-Foot Low Speed Wind Tunnel, 8- by 6-Foot Supersonic Wind Tunnel, and the 10- by 10-Foot Supersonic Wind Tunnel. Effects of hygrometer accuracy and saturation vapor pressure model choice on Mach number are also investigated. Information in this presentation is intended for discussion with the AETC-supported Wind Tunnel Characterization Working Group during the 2023 Face-to-Face Meetings July 25-27 at NASA Glenn Research Center.

Humidity

Relative Humidity Measurement Assurance Program Results

During the summer of 1992, the National Conference of Standards Laboratories sponsored a relative humidity measurement assurance program (RHMAP) whose purpose was to enable each participating center to assess the quality of relative humidity calibrations being performed by their respective standards laboratories. This paper presents the data which was submitted by the participants during the first round of the program and shows the multi-laboratory comparisons of the 20%, 50%, and 80% relative humidity meaurements performed.

Humidity

Measuring Humidity in Sealed Glass Encasements

A technique has been devised for measuring the relative humidity levels in the protective helium/water vapor atmosphere in which the Declaration of Independence, the United States Constitution, and the Bill of Rights are encased behind glass panels on display at the National Archives in Washington, DC. The technique is noninvasive: it does not involve penetrating the encasements (thereby risking contamination or damage to the priceless documents) to acquire samples of the atmosphere. The technique could also be applied to similar glass encasements used to protect and display important documents and other precious objects in museums. The basic principle of the technique is straightforward: An encasement is maintained at its normal display or operating temperature (e.g., room temperature) while a portion of its glass front panel is chilled (see Figure 1) until condensed water droplets become visible on the inside of the panel. The relative humidity of the enclosed atmosphere can then be determined as a known function of the dew point, the temperature below which the droplets condense. Notwithstanding the straightforwardness of the basic principle, careful attention to detail is necessary to enable accurate determination of the dew point. In the initial application, the affected portion of the glass panel was cooled by contact with an aluminum plate that was cooled by a thermoelectric module, the exhaust heat of which was dissipated by a heat sink cooled by a fan. A thermocouple was used to measure the interior temperature of the aluminum plate, and six other thermocouples were used to measure the temperatures at six locations on the cooled outer surface of the glass panel (see Figure 2). Thermal grease was applied to the aluminum plate and the thermocouples to ensure close thermal contact. Power was supplied to the thermoelectric module in small increments, based on previous laboratory tests. A small flashlight and a magnifying glass were used to look for water droplets condensing on the inner surface of the glass. The temperature readings of the thermocouples were taken during cool-down and upon observing condensation. In determining the dew point, it was necessary to make a correction for the differences between the temperatures measured on the chilled outer surface of the glass and the temperature of the inner surface, where the condensation took place. The correction was derived from a laboratory test on a measurement setup that was nearly identical, except that the dew location on the inner surface was also instrumented with a thermocouple. The test showed that the temperature at the dew location on the inner surface of the glass panel was 0.9 C above the temperature determined from the measurements on the chilled outer surface of the panel.

West, James W.

Measuring Humidity in the Charters of Freedom Encasements Using a Moisture Condensation Method

The relative humidity of the atmosphere in the encasements containing the U.S. Constitution Pages 1 and 4, the Declaration of Independence, and the Bill of Rights was measured to be in the range of 55% to 61%. This value is significantly higher than the presumed relative humidity between 25 to 35 %, but is consistent with the measured samples extracted from Pages 2 and 3 of the U.S. Constitution. The cooling/condensation measurement technique used at NARA on July 23, 2001, and described in this paper to measure the water vapor content of the atmosphere in the hermetically sealed encasements containing the U. S. Constitution, the Declaration of Independence, and the Bill of Rights, proved to be a powerful new measurement technique. The cooling/condensation technique developed at NASA LaRC and utilized at NARA has important applications in the non-invasive measurement of relative humidity in the atmospheres of sealed encasements and could become a standard measurement technique in this type of analysis.

Burkett, Cecil G.

In Situ Air Temperature and Humidity Measurements Over Diverse Land Covers in Greenbelt, Maryland, November 2013-November 2015

As our climate changes through time there is an ever-increasing need to quantify how and where it is changing so that mitigation strategies can be implemented. Urban areas have a disproportionate amount of warming due, in part, to the conductive properties of concrete and asphalt surfaces, surface albedo, heat capacity, lack of water, etc. that make up an urban environment. The NASA Climate Adaptation Science Investigation working group at Goddard Space Flight Center in Greenbelt, MD, conducted a study to collect temperature and humidity data at 15 min intervals from 12 sites at the center. These sites represent the major surface types at the center: asphalt, building roof, grass field, forest, and rain garden. The data show a strong distinction in the thermal properties of these surfaces at the center and the difference between the average values for the center compared to a local meteorological station. The data have been submitted to Oak Ridge National Laboratory Distributed Active Archive Center (ORNL-DAAC) for archival in comma separated value (csv) file format (Carroll et al.,2016) and can be found by following this link: http:daac.ornl.govcgi-bindsviewer.pl?ds_id1319.

Carroll, Mark L.

Investigations of Compression Shocks and Boundary Layers in Gases Moving at High Speed

The mutual influences of compression shocks and friction boundary layers were investigated by means of high speed wind tunnels.Schlieren optics provided a clear picture of the flow phenomena and were used for determining the location of the compression shocks, measurement of shock angles, and also for Mach angles. Pressure measurement and humidity measurements were also taken into consideration.Results along with a mathematical model are described.

Ackeret, J.

Measurements of Humidity in the Atmosphere and Validation Experiments (Mohave, Mohave II): Results Overview

The Measurements of Humidity in the Atmosphere and Validation Experiments (MOHAVE, MOHAVE-II) inter-comparison campaigns took place at the Jet Propulsion Laboratory (JPL) Table Mountain Facility (TMF, 34.5(sup o)N) in October 2006 and 2007 respectively. Both campaigns aimed at evaluating the capability of three Raman lidars for the measurement of water vapor in the upper troposphere and lower stratosphere (UT/LS). During each campaign, more than 200 hours of lidar measurements were compared to balloon borne measurements obtained from 10 Cryogenic Frost-point Hygrometer (CFH) flights and over 50 Vaisala RS92 radiosonde flights. During MOHAVE, fluorescence in all three lidar receivers was identified, causing a significant wet bias above 10-12 km in the lidar profiles as compared to the CFH. All three lidars were reconfigured after MOHAVE, and no such bias was observed during the MOHAVE-II campaign. The lidar profiles agreed very well with the CFH up to 13-17 km altitude, where the lidar measurements become noise limited. The results from MOHAVE-II have shown that the water vapor Raman lidar will be an appropriate technique for the long-term monitoring of water vapor in the UT/LS given a slight increase in its power-aperture, as well as careful calibration.

lidar

Total Temperature Measurements in Icing Cloud Flows Using a Rearward Facing Probe

This paper reports on temperature and humidity measurements from a series of ice-crystal icing tunnel experiments conducted in June 2018 at the Propulsion Systems Laboratory at the NASA Glenn Research Center. The tests were fundamental in nature and were aimed at investigating the icing processes on a two-dimensional NACA0012 airfoil subjected to artificially generated icing clouds. Prior to the tests on the airfoil, a suite of instruments, including total temperature and humidity probes, were used to characterize the thermodynamic flow and icing cloud conditions of the facility. Two different total temperature probes were used in these tests which included a custom designed rearward facing probe and a commercial self-heating total temperature probe. The rearward facing probe, the main total temperature probe, was designed to reduce and mitigate the contaminating effects of icing and ingestion of ice crystals and water droplets at the probe's inlet. The probe also serves as an air-sample inlet for a light absorption based humidity measurement. The paper includes a section which discusses total temperature and humidity measurement considerations, and another section which provides an analysis of the main probe's performance characteristics. A computational fluid dynamic model of the flow around the probe was also conducted to gain insight into the trajectory of the flow entering the probe inlet. The experiments included a series of tests in which the relative humidity of the facility flow was swept through with increasingly larger values. The data showed that the rearward facing probe can reasonably capture the flow's total temperature and humidity under mild to moderate icing conditions but produces anomalous results under more intense icing conditions. The experimental data was also compared to an in-house developed thermodynamic model which takes into account the interaction of the main flow with the icing cloud. Comparison to the thermodynamic model showed that the rearward facing probe measured the predicted trends.

Agui, Juan H.

Water-absorbing capacitor system for measuring relative humidity

A method and apparatus using a known water-absorbent polymer as a capacitor which is operated at a dc voltage for measuring relative humidity is presented. When formed as a layer between porous electrically-conductive electrodes and operated in an RC oscillator circuit, the oscillator frequency varies inversely with the partial pressure of the moisture to be measured. In a preferred embodiment, the capacitor is formed from Nafion and is operated at a low dc voltage with a resistor as an RC circuit in an RC oscillator. At the low voltage, the leakage current is proper for oscillation over a satisfactory range. The frequency of oscillation varies in an essentially linear fashion with relative humidity which is represented by the moisture being absorbed into the Nafion. The oscillation frequency is detected by a frequency detector.

Laue, Eric G.

On remote sounding of the upper atmosphere of Venus

Some of the possibilities for remote sensing of the upper atmosphere of Venus from an orbiting spacecraft are studied quantitatively. Temperature sounding over a wide vertical range, from the main cloud top near 60 km altitude to the nanobar level near 160 km, is shown to be feasible. Techniques which deconvolve the cloud structure from the temperature profile measurements are examined. Humidity measurements by simple radiometry are feasible for column abundances greater than or equal to 10 precipitable micrometers. The information content of limb radiance measurements, in different wavelengths and for various viewing geometries, is also analyzed.

Houghton, J. T.

G-band FMCW Radar for Humidity Profiling Inside Boundary Layer Clouds

We are developing a G-band FMCW radar for remote sensing of vertical water vapor profiles and total column water vapor. The radar utilizes the frequency-dependent absorption near the 183 GHz water absorption line to obtain a differential signal from which we can derive range-resolved humidity measurements. This proof-of-concept instrument will eventually be tested from an airborne platform. In this report, we discuss recent measurements and a humidity profile retrieval algorithm based on an absorption line shape fitting model

Monje, Raquel

Atmospheric moisture measurements - A microwave radiometer-radiosonde comparison

Measurements of the thermal emission of the sky at three frequencies (20.7, 22.2, and 31.4 GHz) with the NASA/Goddard Space Flight Center Crustal Dynamics Project MW Water Vapor Radiometer are reported. These measurements are compared with brightness temperatures inferred from measurements from VAISALA radiosonde packages launched every 3 hr during the experiment period. An error analysis for the radiosonde-inferred brightness temperatures is performed under the assumption of reasonable random uncertainties for the pressure, temperature, and humidity measurements and propagation of these uncertainties through the analysis algorithm. For the assumed uncertainties, the dominant contribution to the total uncertainty comes from the temperature measurement (66-88 percent), whereas the relative humidity measurement contributes only 2-8 percent, except in the vicinity of the water vapor line, where the contribution is 10-20 percent.

England, Martin N.

Measuring Moisture Levels in Graphite Epoxy Composite Sandwich Structures

Graphite epoxy composite (GEC) materials are used in the construction of rocket fairings, nose cones, interstage adapters, and heat shields due to their high strength and light weight. However, they absorb moisture depending on the environmental conditions they are exposed to prior to launch. Too much moisture absorption can become a problem when temperature and pressure changes experienced during launch cause the water to vaporize. The rapid state change of the water can result in structural failure of the material. In addition, heat and moisture combine to weaken GEC structures. Diffusion models that predict the total accumulated moisture content based on the environmental conditions are one accepted method of determining if the material strength has been reduced to an unacceptable level. However, there currently doesn t exist any field measurement technique to estimate the actual moisture content of a composite structure. A multi-layer diffusion model was constructed with Mathematica to predict moisture absorption and desorption from the GEC sandwich structure. This model is used in conjunction with relative humidity/temperature sensors both on the inside and outside of the material to determine the moisture levels in the structure. Because the core materials have much higher diffusivity than the face sheets, a single relative humidity measurement will accurately reflect the moisture levels in the core. When combined with an external relative humidity measurement, the model can be used to determine the moisture levels in the face sheets. Since diffusion is temperaturedependent, the temperature measurements are used to determine the diffusivity of the face sheets for the model computations.

Nurge, Mark

Measurements of Humidity in the Atmosphere: Validation Experiments (MOHAVE I and MOHAVE II). Results Overview and Implication for the Long-Term Lidar Monitoring of Water Vapor in the UT/LS

1. MOHAVE+MOHAVE II = very successful. 2. MOHAVE -> Fluorescence was found to be inherent to all three participating lidars. 3. MOHAVE II -> Fluorescence was removed and agreement with CFH was extremely good up to 16-18 km altitude. 4. MOHAVE II -> Calibration tests revealed unsuspected shortfalls of widely used techniques, with important implications for their applicability to longterm measurements. 5. A factor of 5 in future lidar signal-to-noise ratio is reasonably achievable. When this level is achieved water vapor Raman lidar will become a key instrument for the long-term monitoring of water vapor in the UT/LS

MOHAVE II

Optical Breath Gas Extravehicular Activity Sensor for the Advanced Portable Life Support System

The infrared gas transducer used during extravehicular activity (EVA) in the extravehicular mobility unit (EMU) measures and reports the concentration of carbon dioxide (CO2) in the ventilation loop. It is nearing its end of life and there are a limited number remaining. Meanwhile, the next generation advanced portable life support system (PLSS) now being developed requires CO2 sensing technology with performance beyond that presently in use. A laser diode (LD) spectrometer based on wavelength modulation spectroscopy (WMS) is being developed to address both applications by Vista Photonics, Inc. Accommodation within space suits demands that optical sensors meet stringent size, weight, and power requirements. Version 1.0 devices were delivered to NASA Johnson Space Center (JSC) in 2011. The sensors incorporate a laser diode based CO2 channel that also includes an incidental water vapor (humidity) measurement. The prototypes are controlled digitally with a field-programmable gate array (FPGA)/microcontroller architecture. Version 2.0 devices with improved electronics and significantly reduced wetted volumes were delivered to JSC in 2012. A version 2.5 upgrade recently implemented wavelength stabilized operation, better humidity measurement, and much faster data analysis/reporting. A wholly reconfigured version 3.0 will maintain the demonstrated performance of earlier versions while being backwards compatible with the EMU and offering a radiation tolerant architecture.

Wood, William R.

Magnetoelastic sensors in combination with nanometer-scale honeycombed thin film ceramic TiO2 for remote query measurement of humidity

Ribbonlike magnetoelastic sensors can be considered the magnetic analog of an acoustic bell; in response to an externally applied magnetic field impulse the sensors emit magnetic flux with a characteristic resonant frequency. The magnetic flux can be detected external to the test area using a pick-up coil, enabling query remote monitoring of the sensor. The characteristic resonant frequency of a magnetoelastic sensor changes in response to mass loads. [L.D. Landau and E. M. Lifshitz, Theory of Elasticity, 3rd ed. (Pergamon, New York, 1986). p. 100].Therefore, remote query chemical sensors can be fabricated by combining the magnetoelastic sensors with a mass changing, chemically responsive layer. In this work magnetoelastic sensors are coated with humidity-sensitive thin films of ceramic, nanodimensionally porous TiO2 to make remote query humidity sensors. c2000 American Institute of Physics.

NASA Discipline Life Sciences Technologies