Search NASA⌕ Search

SEARCH · Search NASA

Results for “humidity mixing ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Some features of the structure of the tropical tropopause

Statistics of the minimum saturation humidity mixing ratio are extracted from 2500 radiosonde ascents in the tropics (10 N to 10 S) and in the region of the Asian summer monsoon. Two periods of approximately 20 days are examined, one in the northern winter and one in the northern summer. The relation of the observations to an hypothesis, proposed by A. W. Brewer in 1949, of mass exchange between troposphere and stratosphere is briefly discussed.

Atticks, M. G.↗

Dehydration in the lower Antarctic stratosphere in late winter and spring

The history of minimum temperatures at 50 and 70 mb is examined from NMC, UK Met 0 and ECMWF analyses. MSU channel 24 data are similarly inspected. South Pole sonde data are used to calculate saturation humidity mixing ratio as a function of altitude and time throughout 1987. Saturation with respect to ice could be maintained for water mixing ratios of 3.5 ppmv for a period of about 80 days from mid-June to mid-September. Dehydration to mixing ratios of 1 ppmv or less was possible sporadically. Data from the ER-2 flights between 53 S and 72 S are used in conjunction with particle size measurements and air parcel trajectories to demonstrate the dehydration occurring over Antarctica. Water mixing ratios at the latitude of Punta Arenas (53 S), in conjunction with tracer measurements and trajectory analysis, show that at potential temperatures from about 325 to 400 K, the dryness (less than 3 ppmv) had its origin over Antarctica rather than in the tropics. Water mixing ratios within the Antarctic vortex varied from 1.5 to 3.8 ppmv, with a strong isentropic gradient being evident in the region of high potential vorticity gradients.

Kelly, K. K.↗

Dehydration in the lower Antarctic stratosphere during late winter and early spring, 1987

The history of minimum temperatures at 50 and 70 mb is examined from NMC, UK Met O and ECMWF analyses. MSU channel 24 data are similarly inspected. South Pole sonde data are used to calculate saturation humidity mixing ratio as a function of altitude and time throughout 1987. Saturation with respect to ice could be maintained for water mixing ratios of 3.5 ppmv for a period of about 80 days from mid-June to mid-September. Dehydration to mixing ratios of 1 ppmv or less was possible sporadically. Data from the ER-2 flights between 53 S and 72 S are used in conjunction with particle size measurements and air parcel trajectories to demonstrate the dehydration occurring over Antarctica. Water mixing ratios at the latitude of Punta Arens (53 S), in conjunction with tracer measurements and trajectory analysis, show that at potential temperatures from about 325 to 400 K, the dryness (less than 3 ppmv) had its origin over Antarctica rather than in the tropics. Water mixing ratios within the Antarctic vortex varied from 1.5 to 3.8 ppmv, with a strong isentropic gradient being evident in the region of high potential vorticity gradients.

Kelly, K. K.↗

On the Choice of Variable for Atmospheric Moisture Analysis

The implications of using different control variables for the analysis of moisture observations in a global atmospheric data assimilation system are investigated. A moisture analysis based on either mixing ratio or specific humidity is prone to large extrapolation errors, due to the high variability in space and time of these parameters and to the difficulties in modeling their error covariances. Using the logarithm of specific humidity does not alleviate these problems, and has the further disadvantage that very dry background estimates cannot be effectively corrected by observations. Relative humidity is a better choice from a statistical point of view, because this field is spatially and temporally more coherent and error statistics are therefore easier to obtain. If, however, the analysis is designed to preserve relative humidity in the absence of moisture observations, then the analyzed specific humidity field depends entirely on analyzed temperature changes. If the model has a cool bias in the stratosphere this will lead to an unstable accumulation of excess moisture there. A pseudo-relative humidity can be defined by scaling the mixing ratio by the background saturation mixing ratio. A univariate pseudo-relative humidity analysis will preserve the specific humidity field in the absence of moisture observations. A pseudorelative humidity analysis is shown to be equivalent to a mixing ratio analysis with flow-dependent covariances. In the presence of multivariate (temperature-moisture) observations it produces analyzed relative humidity values that are nearly identical to those produced by a relative humidity analysis. Based on a time series analysis of radiosonde observed-minus-background differences it appears to be more justifiable to neglect specific humidity-temperature correlations (in a univariate pseudo-relative humidity analysis) than to neglect relative humidity-temperature correlations (in a univariate relative humidity analysis). A pseudo-relative humidity analysis is easily implemented in an existing moisture analysis system, by simply scaling observed-minus background moisture residuals prior to solving the analysis equation, and rescaling the analyzed increments afterward.

Dee, Dick P.↗

Raman Lidar Profiling of Aerosols Over the Central US; Diurnal Variability and Comparisons with the GOCART Model

We use profiles of aerosol extinction, water vapor mixing ratio, and relative humidity measured by the ARM SGP Raman lidar in northern Oklahoma to show how the vertical distributions of aerosol extinction and water vapor vary throughout the diurnal cycle. While significant (20-30%) variations in aerosol extinction occurred near the surface as well as aloft, smaller (approximately 10%) variations were observed in the diurnal variability of aerosol optical thickness (AOT). The diurnal variations in aerosol extinction profiles are well correlated with corresponding variations in the average relative humidity profiles. The water vapor mixing ratio profiles and integrated water vapor amounts generally show less diurnal variability. The Raman lidar profiles are also used to evaluate the aerosol optical thickness and aerosol extinction profiles simulated by the GOCART global aerosol model. Initial comparisons show that the AOT simulated by GOCART was in closer agreement with the AOT derived from the Raman lidar and Sun photometer measurements during November 2000 than during September 2000. For both months, the vertical variability in average aerosol extinction profiles simulated by GOCART is less than the variability in the corresponding Raman lidar profiles.

Ferrare, R. A.↗

The structure of the unstable marine boundary layer viewed by lidar and aircraft observations

The marine atmospheric boundary layer (MABL) during a cold-air outbreak off the Atlantic coast between New York and Virginia on January 20, 1983 is characterized on the basis of airborne lidar observations, vertical soundings (potential temperature, vapor mixing ratio, relative humidity, and wind), and horizontal (770-m) temperature records. The data are presented in tables and graphs and analyzed in detail. The organization of the MABL is defined by 1-2-km-scale roll vortices with up and downdrafts of 2-4 m/s at 210 m; north-south orientation of the roll axes (parallel to the low-level winds); rising arms coinciding with updrafts rich in moisture, aerosols, and heat; and 150-200-m (peak-to-trough) undulations of the inversion. Consideration is given to problems inherent in the interpretation of lidar data for MABL studies.

Atlas, D.↗

Notes on the meteorology of the intertropical convergence zone during the July 1977 experiment

The stratosphere and troposphere are large-scale open systems which exchange mass and trace constituents. If averaged over all longitudes, mass exchange can be expressed as products of the means and the mean of the product of the deviations from the mean. At high latitudes, the mass exchange is dominated by the deviations from the mean. At low latitudes, in the tropics, it is generally assumed that the mass exchange is caused by the mean motion. Figures are presented which depict: Northern Hemisphere mean motion; Convergence Zone motion; clouds and their motions; surface pressure variations; and meteorological parameters such as temperature, relative humidity, and ozone mixing ratios.

Danielson, E. F.↗

Convection and Easterly Wave Structure Observed in the Eastern Pacific Warm-Pool during EPIC-2001

During September-October 2001, the East Pacific Investigation of Climate Processes in the Coupled Ocean-Atmosphere System (EPIC-2001) ITCZ field campaign focused on studies of deep convection in the warm-pool region of the East Pacific. In addition to the TAO mooring array, observational platforms deployed during the field phase included the NOAA ship RN Ronald H. Brown, the NSF ship RN Horizon, and the NOAA P-3 and NCAR C-130 aircraft. This study combines C-band Doppler radar, rawinsonde, and surface heat flux data collected aboard the RN Brown to describe ITCZ convective structure and rainfall statistics in the eastern Pacific as a function of 3-5 day easterly wave phase. Three distinct easterly wave passages occurred during EPIC-2001. Wind and thermodynamic data reveal that the wave trough axes exhibited positively correlated U and V winds and a slight westward phase tilt with height. A relatively strong (weak) northeasterly deep tropospheric shear followed the trough (ridge) axis. Temperature and humidity perturbations exhibited mid-to upper level cooling (warming) and drying (moistening) in the northerly (trough and southerly) phase. At low levels warming (cooling) occurred in the northerly (southerly) phase with little change in the relative humidity, though mixed layer mixing ratios were larger during the northerly phase. When composited, radar, sounding, lightning and surface heat flux observations suggest the following systematic behavior as a function of wave phase: approximately zero to one quarter wavelength ahead of (behind) the wave trough in northerly (southerly) flow, larger (smaller) CAPE, lower (higher) CIN, weaker (stronger) tropospheric shear, higher (lower) conditional mean rain rates, higher (lower) lightning flash densities, and more (less) robust convective vertical structure occurred. Latent and sensible heat fluxes reached a minimum in the northerly phase and then increased through the trough, reaching a peak during the ridge phase (leading the peak in CAPE). From a radar echo coverage perspective, larger areas of light rain and slightly larger (10%) area averaged rain rates occurred in the vicinity of, and just behind, the trough axes in southerly flow. Importantly, the transition in convective structure observed across the trough axis when considered with the relatively small change in area mean rain rates suggests the presence of a transition in the vertical structure of diabatic heating across the easterly waves examined. The inferred transition in heating structure is supported by radar diagnosed divergence profiles that exhibit convective (stratiform) characteristics ahead of (behind) the trough.

Peterson, Walter A.↗

Limb Correction of RGB Composite Imagery for Improved Interpretation

RGB (Red‐Green‐Blue) imagery, created by integrating several spectral channels into one composite image, is currently used by the operational weather community to aid in quick, real‐time analysis of atmospheric processes. However, the limb effect - a result of an increasing optical path length of the absorbing atmosphere between the satellite and the earth as scan angle increases - interferes with the qualitative interpretation of RGB composites at large scan angles. It also makes the comparison of similar products from multiple satellite sensors difficult. Recent work has indicated that correcting for the limb effect in the basic channel imagery using simple statistical relationships greatly improves the utility of the derived RGB imagery. However, it is hypothesized that the limb correction coefficients vary with respect to latitude, season, cloud cover, and surface albedo. This poster will highlight an improved approach to the limb correction of RGB imagery using varying coefficients. The Joint Center for Satellite and Data Assimilation (JCSDA) Community Radiative Transfer Model (CRTM) was used to simulate top of atmosphere brightness temperatures at varying scan angles for infrared channels corresponding to the Aqua and Terra Moderate Resolution Imaging Spectroradiometer (MODIS), Suomi NPP Visible Infrared Imaging Radiometer Suite (VIIRS), and Meteosat‐10 Spinning Enhanced Visible and Infrared Imager (SEVIRI) sensors. A subset of European Center for Medium‐Range Weather Forecasts (ECMWF) temperature, specific humidity, and ozone mixing ratio profiles from March 2013 through February 2014 were used as input to the CRTM. The simulated brightness temperatures were used to determine the best fit slope of the linear relationship between the natural log of the cosine of the scan angle and the difference of the simulated brightness temperature at nadir and on the limb. The correction coefficients were then analyzed for variability with respect to latitude, season, cloud cover, and surface type and used to produce improved limb corrected imagery. Applications of the results will be presented.

Elmer, Nicholas↗

Remote sounding of cloudy atmospheres. III - Experimental verifications

The cloud-filtering technique developed in Parts I and II of this study is experimentally verified in this paper. The verification is based on radiance data measured in the 4.3 and 15 micron CO2 bands using a multidetector sounder mounted on an aircraft. The results presented here show that, from the aircraft height of 7.6 km and in the presence of multiple cloud formations, it is possible to recover simultaneously: (1) the clear-column atmospheric temperature profile with an rms error of 1 K with respect to radiosondes, (2) the land and sea surface temperature at all sun zenith angles. The accuracy of the recovered sea-surface temperature is 0.5-1 K with respect to measured bucket temperatures, (3) the humidity profile (water vapor mixing ratio) with a precision of 10%, (4) the fractional covers and heights of up to three cloud formations, and (5) the types of clouds, i.e., whether convective or nonconvective.

Chahine, M. T.↗

Lidar Measurements of Relative Humidity and Ice Supersaturation in the Upper Troposphere

We compute upper tropospheric relative humidity profiles using water vapor profiles measured by an airborne DIAL and a ground-based Raman lidar. LASE water vapor and MTP temperature profiles acquired from the NASA DC-8 aircraft during the recent Pacific Exploratory Mission Tropics B (PEM Tropics B) field mission in the tropical Pacific and the SAGE-III Ozone Loss and Validation Experiment (SOLVE) in the Arctic as well as water vapor profiles derived from the ground-based DOE ARM Southern Great Plains (SGP) CART Raman lidar are used. Comparisons of the lidar water vapor measurements with available in situ measurements show reasonable agreement for water vapor mixing ratios above 0.05 g/kg. Relative humidity frequency distributions computed using LASE data indicate that ice supersaturation occurred about 5-11% of the time when temperatures were below -35 C. While a higher frequency of ice supersaturation was observed during SOLVE, higher peak values of relative humidity were observed during PEM Tropics B. The relative humidity fields associated with cirrus clouds are also examined.

Ferrare, Richard A.↗

Characteristics of Mesoscale Organization in WRF Simulations of Convection during TWP-ICE

Compared to satellite-derived heating profiles, the Goddard Institute for Space Studies general circulation model (GCM) convective heating is too deep and its stratiform upper-level heating is too weak. This deficiency highlights the need for GCMs to parameterize the mesoscale organization of convection. Cloud-resolving model simulations of convection near Darwin, Australia, in weak wind shear environments of different humidities are used to characterize mesoscale organization processes and to provide parameterization guidance. Downdraft cold pools appear to stimulate further deep convection both through their effect on eddy size and vertical velocity. Anomalously humid air surrounds updrafts, reducing the efficacy of entrainment. Recovery of cold pool properties to ambient conditions over 5-6 h proceeds differently over land and ocean. Over ocean increased surface fluxes restore the cold pool to prestorm conditions. Over land surface fluxes are suppressed in the cold pool region; temperature decreases and humidity increases, and both then remain nearly constant, while the undisturbed environment cools diurnally. The upper-troposphere stratiform rain region area lags convection by 5-6 h under humid active monsoon conditions but by only 1-2 h during drier break periods, suggesting that mesoscale organization is more readily sustained in a humid environment. Stratiform region hydrometeor mixing ratio lags convection by 0-2 h, suggesting that it is strongly influenced by detrainment from convective updrafts. Small stratiform region temperature anomalies suggest that a mesoscale updraft parameterization initialized with properties of buoyant detrained air and evolving to a balance between diabatic heating and adiabatic cooling might be a plausible approach for GCMs.

Del Genio, Anthony D.↗

The atmosphere of Uranus - Results of radio occultation measurements with Voyager 2

The Uranian atmosphere is investigated on the basis of S-band and X-band occultation observations (including measurements of Doppler frequency perturbations) obtained during the Voyager 2 encounter with Uranus in January 1986. The data are presented in extensive tables and graphs and characterized in detail. The atmosphere is assumed to have an H2/He abundance ratio of about 85/15, but also to contain small amounts of CH4 at above-cloud relative humidity 30 percent, cloud-base relative humidity 78 percent, and below-cloud mixing ratio 2.3 percent by number density. Other parameters estimated include magnetic-field rotation period 17.24 h, 1-bar equatorial radius 25,559 + or - 4 km, polar radius 24,973 + or - 20 km, equatorial acceleration of gravity 8.69 + or - 0.01 m/sec sq, and atmospheric temperature 76 + or - 2 K (assuming 85 + or - 3 percent H2).

Lindal, G. F.↗

Global seasonal variations of the near-surface relative humidity levels on present-day Mars

We investigate the global seasonal variations of near-surface relative humidity and relevant attributes, like temperature and water vapor volume mixing ratio on Mars using calculations from modelled and measurement data. We focus on 2 AM local time snapshots to eliminate daily effects related to differences in insolation, and to be able to compare calculations based on modelling data from the Laboratoire de Météorologie Dynamique Mars General Circulation Model with the observations of Mars Global Surveyor Thermal Emission Spectrometer. We study the seasonal effects by examining four specific dates in the Martian year, the northern spring equinox, summer solstice, autumn equinox, and winter solstice. We identify three specific zones, where the near-surface relative humidity levels are systematically higher than in their vicinity regardless of season. We find that these areas coincide with low thermal inertia features, which control surface temperatures on the planet, and are most likely covered with unconsolidated fine dust with grain sizes smaller than ∼ 40 μm. By comparing the data of relative humidity, temperature and water vapor volume mixing ratio at three different heights (near-surface, ∼ 4m and ∼ 23m above the surface), we demonstrate that the thermal inertia could play an important role in determining near-surface humidity levels. We also notice that during the night the water vapor levels drop at ∼ 4m above the surface. This, together with the temperature and thermal inertia values, shows that water vapor likely condenses in the near-surface atmosphere and on the ground during the night at the three aforementioned regions. This condensation may be in the form of brines, wettening of the fine grains by adsorption or deliquescence. This study specifies areas of interest on the surface of present day Mars for the proposed condensation, which may be examined by in-situ measurements in the future.

Bernadett Pál↗

TPSAS-NF1676L-11308-DND

The Lidar Atmospheric Sensing Experiment (LASE) system has operated on the NASA ER-2, P-3, and DC-8 aircraft during the past 16 years and participated in 13 field experiments. This system provides vertical profiles of water vapor mixing ratio and aerosol and cloud backscattering. A brief overview is presented on the upgrade of LASE that included refurbishment of laser diode seeding, control and data system, and zenith receiver system. These developments have enhanced the operational reliability of the system and improved its performance. The LASE system was deployed on the NASA DC-8 aircraft recently for the NASA GRIP (Genesis and Rapid Intensification Processes) field experiment, which was conducted during August and September 2010 from operational bases in Fort Lauderdale, FL and St. Croix, VI. Initial measurements from this field experiment are presented including distributions of water vapor, aerosol, and clouds. Temperature profiles from DC-8 dropsondes and nearby radiosondes are used to derive relative humidity profiles from the LASE water vapor mixing ratio profiles. Comparisons of LASE water vapor mixing ratio profiles with those measured by the new AVAPS-II dropsondes from the NASA DC-8 are also presented.

Susan A Kooi↗

Comparison of observed and computed brightness temperatures for the HIRS2 and MSU sounders on TIROS-N

Given the radiosonde temperature and humidity profile, brightness temperatures for the temperature sounding IR channels on HIRS 2 were calculated. The temperature profile was interpolated to 53 levels between 1000 and 30 mb assuming temperature to be linear in the logarithm of the pressure between the mandatory levels. The 11 levels above 30 mb were extrapolated according to climatology. The surface was taken to be the climatological sea surface temperature. The specific humidity was interpolated between mandatory levels assuming a p(n) dependence. A specific humidity corresponding to a climatological water vapor mixing ratio of 2 ppmv was assumed at and above 100 mb. Zonally averaged climatological ozone profiles were used to compute the ozone component of the transmittance.

Susskind, J.↗