Search NASA⌕ Search

SEARCH · Search NASA

Results for “humidity mixing ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Combined Mesonet and Tracker

Title: Combined Mesonet and Trackers (UNL Mobile Mesonets) Authors University of Nebraska PI: Adam Houston, UNL Professor (ahouston2@unl.edu) Mailing Address: 126 Bessey Hall P.O. Box 880340 Lincoln, NE 68588-0340 CoMeT Overview The University of Nebraska-Lincoln operates three Combined Mesonet and Tracker (CoMeTs). CoMeTs are Ford Explorers (model years 2015, 2017, and 2019) with forward-mounted suites of meteorological sensors and dual moonroofs, combining the capability of a mobile mesonet to collect near-surface observations with the capability of an unmanned aircraft systems (UAS) tracker vehicle, which enables an observer in the second row of seats to see the aircraft and maintain compliance with Federal Aviation Administration policies on UAS operation. The CoMeTs collect observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155A, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, and vehicle heading using a KVH Industries C-100 fluxgate compass (Barbieri et al. 2019). The HMP155A and 109SS-L thermistor are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). This list of sensors is also included in the CoMeT data file metadata. Manufacturer specifications for these instruments are given in Table 1 of Hanft and Houston (2018). The reported measured quantities are summarized below.CoMeT-3 was funded through an equipment allocation included in the NSF TORUS award (AGS-1824649). Instrument Description The specific sensors included on each CoMeT are summarized in the table at the end of this section. In general each CoMeT collects observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210 barometer with a Gill pressure port, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, position using a Garmin 19x HVS receiver, and vehicle heading using a KVH Industries C-100 fluxgate compass. The HMP155 and 109SS are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). Fast temperature and corrected RH measurements (using sensors housed within the U-tube) have a time constant of 10-12 s based on data collected across a temperature and RH shock during the CLOUD-MAP 2017 calibration/validation tests on June 26, 2017. Vehicle speed was < 10 kts for this test. CoMeT-1 CoMeT-2 CoMeT-3 Slow Temperature Slow RH Vaisala HMP155A-L20-PT Part #: 22280-7 Vaisala HMP155E Part #: E1AA11A0B1A1A0A Vaisala HMP155E Part #: E1AA11A0B1A1A0A Fast temperature Campbell Scientific 109SS-L20-PT Part #: 21448-3 Campbell Scientific 109SS-L12-PW Part #: 21448-109 Campbell Scientific 109SS-L12-PW Part #: 21448-150 Pressure Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Wind RM Young 05103-L20-PT Part #: 18435-310 RM Young 05103-L20-PW Part #: 18435-244 RM Young 05103-L20-PW Part #: 18435-244 GPS Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Compass KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 Logger Campbell Scientific CR6-NA-XT-SW Part #: 28385-9 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Data Collection and Real-Time Processing The reported measured quantities are summarized in the table below. Quantity Units Source Epoch time Seconds GPS Latitude and longitude Degrees GPS Altitude m GPS Pressure hPa PTB210 Temperature (fast) deg C 109SS-L Temperature (slow) deg C HMP155 RH (slow) % HMP155 Vehicle speed m/s GPS Vehicle heading deg C-100 and GPS In addition to the measured variables, several derived variables are calculated. Corrected/fast relative humidity (%) Relative humidity is adjusted to the fast temperature following Richardson et al. (1998) and Houston et al. (2016). Water vapor mixing ratio (g/kg) Dew point temperature (&deg;C) Potential temperature (Kelvin) Virtual potential temperature (Kelvin) Equivalent potential temperature (Kelvin) Regular intercomparisons between all three CoMeTs were performed during TORUS 2019. Comparisons were also conducted between CoMeT-1 and CoMeT-2 during LAPSE-RATE (2018) on 14 July. In these intercomparisons, the vehicles were parked adjacent to each other aligned perpendicular to (and facing into) the wind. To minimize engine heating effects, intercomparisons were only conducted when the wind speed was >10 kts. Data Format Original data files for each deployment are saved as text files and then converted to NetCDF. NetCDF versions have units that are CF compliant and may not match the original units in the txt files. The naming convention for the NetCDF files is as follows: UNL.CoMeT3.{deployment date YYYYMMDD}.{start time of observation collection in UTC HHMM}.L2.{post-processing codes}.cdf example: UNL.CoMeT3.20190627.1931.L2.g1.f1.cdf Post-processing codes are included to track modifications to the raw data. These codes are closely connected to error flags associated with each record. Each letter corresponds to a particular instrument: g: GPS p: Barometer tf: Fast temperature ts: Slow temperature rh: Relative humidity f: Compass w: Wind monitor a: All instruments Each number corresponds to a particular post-processing action described more below. Measured and derived variables are included in the following table. Variable Heading Standard Name Units time Time seconds since 00:00:00, 01-01-1970 Alt Altitude meters lat Latitude degrees north lon Longitude degrees east fast_temp Air Temperature kelvin slow_temp Air Temperature kelvin pressure Air Pressure pascals logger_RH Relative Humidity percent calc_corr_RH Relative Humidity percent wind_speed Wind Speed meters per second wind_dir Wind From Direction degrees vehicle_dir Vehicle Direction degrees dewpoint Dew Point Temperature kelvin mixing_ratio Humidity Mixing Ratio g/g theta Air Potential Temperature kelvin theta_v Virtual Potential Temperature kelvin theta_e Equivalent Potential Temperature Kelvin error_flag The error_flag variable is a string that matches the post-processing codes listed above. All instruments will have an associated code, but will have a &ldquo;0&rdquo; if the datum is unchanged from the initial processed value. Error Codes The following table summarizes the error codes for data collected before 2020: Error Code Relevant CoMeT Description g1 1,2,3 Exact correction. GPS position and time reprocessed from raw data g2 1 As far as we can tell this is an exact correction to an error in the GPS time. During the correct time periods the time suddenly went backwards ~250s and stayed at this offset for 750s when it corrected itself. The offset was applied to the &ldquo;time warp&rdquo; period. p1 2 Approximate correction. Hole in the pressure tube connecting the pressure port to the barometer. Resulted in erroneously low air pressure measurements when the vehicle was in motion. Derived variables recalculated (dew point temperature [e depends on qv and p], water vapor mixing ratio, potential temperature, virtual potential temperature, equivalent potential temperature) a1 3 Exact correction. Missing data reprocessed from raw data a2 1 Bug fix to bias correction for ts1, ts2, and rh1: water vapor mixing ratio was off by a factor of 10 and virtual potential temperature was wrong because of this. f1 3 No correction, missing data. Fluxgate compass inoperable. Wind speed and direction calculated using GPS-derived vehicle heading instead. rh1 1 Approximate correction. Constant bias of +1.7% removed from relative humidity. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts1 1 Approximate correction. Constant bias of +0.6 K removed from slow temperature. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts2 1 Approximate correction. Constant bias of +1.0 K removed. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) References Bolton, D., 1980: The Computation of Equivalent Potential Temperature. Mon. Wea. Rev., 108, 1046&ndash;1053, https://doi.org/10.1175/1520-0493(1980)108<1046:TCOEPT>2.0.CO;2. Hanft, W., and A. L. Houston, 2018: An Observational and Modeling Study of Mesoscale Air Masses with High Theta-E. Mon. Wea. Rev., 146, 2503&ndash;2524, https://doi.org/10.1175/MWR-D-17-0389.1.Wexler Houston, A. L., R. J. Laurence III, T. W. Nichols, S. Waugh, B. Argrow, and C. L. Ziegler, 2016: Intercomparison of unmanned aircraft-borne and mobile mesonet atmospheric sensors. Journal of Atmospheric and Oceanic Technology. 33, 1569-1582, doi: 10.1175/JTECH-D-15-0178.1. Lowe, P. R., 1977: An Approximating Polynomial for the Computation of Saturation Vapor Pressure. J. Applied Meteorology, 16, 100&ndash;103. Richardson, S. J., S. E. Frederickson, F. V. Brock, and J. A. Brotzge, 1998: Combination temperature and relative humidity probes: Avoiding large air temperature errors and associated relative humidity errors. Preprints, 10th Symp. On Meteorological Observations and Instrumentation, Phoenix, AZ, Amer. Meteor. Soc., 278&ndash;283. Waugh, S., and S. E. Frederickson, 2010: An improved aspirated temperature system for mobile meteorological observations, especially in severe weather. 25th Conf. on Severe Local Storms, Denver, CO, Amer. Meteor. Soc., P5.2. [Available online at https://ams.confex.com/ams/25SLS/techprogram/paper_176205.htm.]

54 ENVIRONMENTAL SCIENCES↗

NCAR/EOL ISFS Data for LASSO-CACTI Overview Paper

5 minute averages of surface meteorology and flux data collected by the NCAR/EOL Integrated Surface Flux System (ISFS) at 15 sites during the RELAMPAGO field campaign. These data have been quality-controlled and are available in NetCDF format. Winds reported by the sonic anemometers have been tilt corrected and rotated into geographic coordinates. Data providence, citation, and acknowledgement This ARM data set is a copy of v2.0 of the NCAR data set obtained on 6-Jun-2024 from https://doi.org/10.26023/ZPHJ-JW9W-2B0Y. The citation for the original data source is: NCAR/EOL In-situ Sensing Facility, Oncley, S. 2021. NCAR/EOL ISFS Surface Meteorology and Flux Products, 5-minute. Version 2.0. UCAR/NCAR - Earth Observing Laboratory. https://doi.org/10.26023/ZPHJ-JW9W-2B0Y Accessed 06 Jun 2024. In addition to the citation reference and any other acknowledgements, please acknowledge NCAR/EOL in your publications with text such as: "Data provided by NCAR/EOL under the sponsorship of the National Science Foundation. https://data.eol.ucar.edu/"

atmosphere: surface↗

Back Trajectories during SAIL

This data set contains air mass back trajectories generated during the Surface Atmosphere Integrated Field Laboratory (SAIL) campaign using the Hybrid Single-Particle Lagrangian Integrated Trajectory model (HYSPLIT, Stein et al. 2015, Rolph et al. 2017). For each hour from January 1, 2021 to June 30, 2023, a 96-hour back trajectory was initiated at the SAIL sampling site, starting 100 m above ground level. The calculations used the GDAS meteorological data set with model vertical velocity. The files within this dataset show location and meteorological parameters of the back trajectory analysis. There are 21 columns within each data file. The first 2 columns pertain to back trajectory parameters: the trajectory number (which is always 1) and the meteorological grid number. The next 9 columns pertain to spatiotemporal information: the year, month, day, hour (0-23), and minute of the trajectory, the previous time of the trajectory (in negative hours), and the airmass location (latitude, longitude, and height in m AGL). The rest of the parameters within each file pertains to surface and meteorological characteristics of the airmass: pressure (in hPa), potential temperature (in K), temperature (in K), precipitation rate (in mm/hr), mixing depth (in m), relative humidity (in % relative to liquid water), specific humidity (in g/kg), H2O mixing ratio (in g/kg), underlying terrain height (in meters above sea level), and incoming radiation (in W/m^2).

back trajectory↗

Trace Gases, Meteorological Parameters, and GPS data for TRACER-MAP

This dataset includes trace gas, meteorological, and GPS measurements made on Mobile Air Quality Laboratory 2 (MAQL2) for the TRACER-MAP sampling campaign. Trace gas measurements include nitric oxide (NO), nitrogen dioxide (NO2), reactive nitrogen compounds (NOy), ozone (O3), sulfur dioxide (SO2), and carbon monoxide (CO). All trace gases are in units of ppbv, excluding CO which is in ppmv. The dataset also includes the photolysis rate of NO2 (jNO2), latitude and longitude, wind speed (WS), wind direction (WD), ambient relative humidity (RH), ambient pressure (press), and ambient temperature (temp). Units for trace gases are in parts per billion (ppbv), latitude and longitude are in decimal degrees (dd), jNO2 is in per second (per sec), pressure is in millibar (mbar), relative humidity is in percent, the temperature is in degrees C, wind direction is in degrees, and wind speed is in meters per second. All data is 5 minutes averaged.

54 ENVIRONMENTAL SCIENCES↗

Empirical prediction of saline water atomization pressure loss and spray phase change using local flow pressure analysis

A pressure analysis technique was developed to obtain spray spatial evaporation profile in a thermal desalination process. The technique can replace temperature-based evaporation measurement methods that are challenged by liquid-phase interference. It also provides an alternative to optical methods with high cost and complexity. Fundamental analysis was developed to determine local humidity ratios from changes in local static and dynamic pressures. The analysis was applied to data obtained from an external mixing air-assist atomizer. An empirical model was developed for the pressure loss in atomization process and was used in the analysis of humidity ratio. The results were used to develop empirical correlations for local humidity ratio in spray mediums using inlet conditions. Utilizing inlet conditions to predict evaporation profiles is an important contribution as it eliminates the need to take local spray measurements. Obtaining local data is often difficult and expensive; Our method and correlation circumvent the need for that. Finally, the correlations presented in this paper apply to saline water sprays with total dissolved salt of 0-10 wt%. The salinity-specific correlations are accurate to within ±10% of experimental data. The individual models were aggregated into a unified correlation for salinities within 0-10 wt%. The unified correlation is accurate to within ±18% of experimental data.

42 ENGINEERING↗

Tower Water-Vapor Mixing Ratio Value-Added Product Report

The purpose of the Tower Water-Vapor Mixing Ratio (TWRMR) value-added product (VAP) is to calculate water-vapor mixing ratios at the 25-meter and 60-meter levels of the meteorological tower and also report best-estimate temperature, relative humidity, and pressure measurements at the 2-meter, 25-meter, and 60-meter levels at the Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) Central Facility. Because there are no barometric pressure sensors at the 25-meter and 60-meter levels on the tower, the hypsometric equation is used along with surface pressure values from the surface meteorological instrumentation (MET), the surface meteorological observation system (SMOS), or the temperature, humidity, wind, and pressure system (THWAPS) to derive barometric pressures at those altitudes (Ritsche 2008, 2011a, 2011b). After this is done, water-vapor mixing ratio can be calculated directly.

54 ENVIRONMENTAL SCIENCES↗

TRACER UAS CopterSonde Profiles

This dataset comes from a rotary-wing, weather-sensing uncrewed aerial system called the CopterSonde. Temperature, pressure, humidity, wind speed, and direction are gathered during vertical profiles. The vertical resolution is 5 m up to 609 m above ground level and the temporal resolution is on average 30 minutes.

54 ENVIRONMENTAL SCIENCES↗

Droplet Growth or Evaporation Does Not Buffer the Variability in Supersaturation in Clean Clouds

Abstract Water vapor supersaturation in clouds is a random variable that drives activation and growth of cloud droplets. The Pi Convection–Cloud Chamber generates a turbulent cloud with a microphysical steady state that can be varied from clean to polluted by adjusting the aerosol injection rate. The supersaturation distribution and its moments, e.g., mean and variance, are investigated for varying cloud microphysical conditions. High-speed and collocated Eulerian measurements of temperature and water vapor concentration are combined to obtain the temporally resolved supersaturation distribution. This allows quantification of the contributions of variances and covariances between water vapor and temperature. Results are consistent with expectations for a convection chamber, with strong correlation between water vapor and temperature; departures from ideal behavior can be explained as resulting from dry regions on the warm boundary, analogous to entrainment. The saturation ratio distribution is measured under conditions that show monotonic increase of liquid water content and decrease of mean droplet diameter with increasing aerosol injection rate. The change in liquid water content is proportional to the change in water vapor concentration between no-cloud and cloudy conditions. Variability in the supersaturation remains even after cloud droplets are formed, and no significant buffering is observed. Results are interpreted in terms of a cloud microphysical Damköhler number (Da), under conditions corresponding to , i.e., the slow-microphysics regime. This implies that clouds with very clean regions, such that is satisfied, will experience supersaturation fluctuations without them being buffered by cloud droplet growth. Significance Statement The saturation ratio (humidity) in clouds controls the growth rate and formation of cloud droplets. When air in a turbulent cloud mixes, the humidity varies in space and time throughout the cloud. This is important because it means cloud droplets experience different growth histories, thereby resulting in broader size distributions. It is often assumed that growth and evaporation of cloud droplets buffers out some of the humidity variations. Measuring these variations has been difficult, especially in the field. The purpose of this study is to measure the saturation ratio distribution in clouds with a range of conditions. We measure the in-cloud saturation ratio using a convection cloud chamber with clean to polluted cloud properties. We found in clouds with low concentrations of droplets that the variations in the saturation ratio are not suppressed.

54 ENVIRONMENTAL SCIENCES↗

The Impact of Nonzenith Elevation Angles on Ground-Based Infrared Thermodynamic Retrievals

Observing thermodynamic profiles within the planetary boundary layer is essential to understanding and predicting atmospheric phenomena because of the significant exchange of sensible and latent heat between the land and atmosphere within that layer. The Atmospheric Emitted Radiance Interferometer (AERI) is a ground-based infrared spectrometer used to obtain the vertical profiles of temperature and water vapor mixing ratio. Most AERIs are only capable of zenith views, although the Marine AERI (M-AERI) has a design that allows it to view various elevation angles. In this study, we quantify the improvement in the information content and accuracy of the retrieved profiles when nonzenith angles are included, as is common with microwave radiometer profilers. The impacts of the additional scan angles are quantified through both a synthetic study and with M-AERI observations from the ARM Cloud Aerosol Precipitation Experiment (ACAPEX) campaign. Furthermore, the simulation study shows that low elevation angles contain more information content for temperature whereas high elevation angles have more information content for water vapor. Outside of very humid environments, the addition of low elevation angles also results in lower root-mean-square errors when compared with high angles for both temperature and water vapor mixing ratio, although this is primarily a result of averaging multiple observations together to reduce instrument noise. Real-world results from the ACAPEX dataset indicate similar results as were found for the simulation study, although not all predicted benefits are realized because of the small sample size and observational uncertainties.

54 ENVIRONMENTAL SCIENCES↗

TRACER-Tethersonde Ozone data

TRACER-Tethersonde, a sub-campaign of TRACER, took place during the TRACER June-September 2022 intensive operating period (IOP) at the S3 Ancillary site (29.33°N, 95.74°W) near Guy, TX. The Tethered Balloon System (TBS) operated during the first two weeks of each month during the TRACER IOP, making multiple (~4) up and down vertical profiles each day that could reach as high as ~1 km. TRACER-Tethersonde included an En-Sci electrochemical cell (ECC) ozonesonde on the TBS. The ozonesonde was connected to an iMet-4RSB radiosonde, and the overall data collected included ozone, relative humidity, temperature, and altitude.

54 ENVIRONMENTAL SCIENCES↗

Direct Ink-Write Printing of Ceramic Clay with an Embedded Wireless Temperature and Relative Humidity Sensor

This research presents a simple method to additively manufacture Cone 5 porcelain clay ceramics by using the direct ink-write (DIW) printing technique. DIW has allowed the application of extruding highly viscous ceramic materials with relatively high-quality and good mechanical properties, which additionally allows a freedom of design and the capability of manufacturing complex geometrical shapes. Clay particles were mixed with deionized (DI) water at different ratios, where the most suitable composition for 3D printing was observed at a 1:5 w/c ratio (16.2 wt.%. of DI water). Differential geometrical designs were printed to demonstrate the printing capabilities of the paste. In addition, a clay structure was fabricated with an embedded wireless temperature and relative humidity (RH) sensor during the 3D printing process. The embedded sensor read up to 65% RH and temperatures of up to 85 °F from a maximum distance of 141.7 m. The structural integrity of the selected 3D printed geometries was confirmed through the compressive strength of fired and non-fired clay samples, with strengths of 70 MPa and 90 MPa, respectively. This research demonstrates the feasibility of using the DIW printing of porcelain clay with embedded sensors, with fully functional temperature- and humidity-sensing capabilities.

42 ENGINEERING↗

Subcloud and Cloud-Base Latent Heat Fluxes during Shallow Cumulus Convection

Doppler and Raman lidar observations of vertical velocity and water vapor mixing ratio are used to probe the physics and statistics of subcloud and cloud-base latent heat fluxes during cumulus convection at the ARM Southern Great Plains (SGP) site in Oklahoma, United States. The statistical results show that latent heat fluxes increase with height from the surface up to ~0.8 Z i (where Z i is the convective boundary layer depth) and then decrease to ~0 at Z i . Peak fluxes aloft exceeding 500 W m −2 are associated with periods of increased cumulus cloud cover and stronger jumps in the mean humidity profile. These entrainment fluxes are much larger than the surface fluxes, indicating substantial drying over the 0–0.8 Z i layer accompanied by moistening aloft as the CBL deepens over the diurnal cycle. We also show that the boundary layer humidity budget is approximately closed by computing the flux divergence across the 0–0.8 Z i layer. Composite subcloud velocity and water vapor anomalies show that clouds are linked to coherent updraft and moisture plumes. The moisture anomaly is Gaussian, most pronounced above 0.8 Z i and systematically wider than the velocity anomaly, which has a narrow central updraft flanked by downdrafts. This size and shape disparity results in downdrafts characterized by a high water vapor mixing ratio and thus a broad joint probability density function (JPDF) of velocity and mixing ratio in the upper CBL. We also show that cloud-base latent heat fluxes can be both positive and negative and that the instantaneous positive fluxes can be very large (~10 000 W m −2 ). However, since cloud fraction tends to be small, the net impact of these fluxes remains modest.

54 ENVIRONMENTAL SCIENCES↗

NANT Site - Microwave Radiometer Thermodynamic Retrievals TROPoe / Derived Data

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). The profiles are retrieved every 10 minutes from instantaneous brightness temperature measurements at 35 channels observed with a microwave radiometer MP3000A operated by NOAA Physical Sciences Laboratory on Nantucket Island for WFIP3. Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a sensor attached to the MWR housing. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY.

17 WIND ENERGY↗

NANT Site - ASSIST / Thermodynamic retrievals TROPoe / Derived Data

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). The profiles are retrieved every 10 minutes from instantaneous radiances observed with an Atmospheric Sounder Spectrometer by Infrared Spectral Technology (ASSIST, Rochette et al. 2009) operated by NOAA Physical Sciences Laboratory on Nantucket Island for WFIP3. The spectral bands used in the retrieval are in the wavenumber range from 612 - 905.4 cm-1 and are specified in Turner and Löhnert (2021). Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a sensor attached to the ASSIST housing. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY.

17 WIND ENERGY↗

NOAA PSL Microwave Radiometer Block Island / Thermodynamic retrievals TROPoe

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). The profiles are retrieved every 10 minutes from instantaneous brightness temperature measurements at 35 channels observed with a microwave radiometer MP3000A operated by NOAA Physical Sciences Laboratory on the Block Island for WFIP3. Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a sensor attached to the MWR housing. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY.

17 WIND ENERGY↗

BLOC Site - ASSIST Thermodynamic retrievals TROPoe / Derived Data

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). The profiles are retrieved every 10 minutes from instantaneous radiances observed with an Atmospheric Sounder Spectrometer by Infrared Spectral Technology (ASSIST, Rochette et al. 2009) operated by NOAA Physical Sciences Laboratory on Block Island for WFIP3. The spectral bands used in the retrieval are in the wavenumber range from 612 - 905.4 cm-1 and are specified in Turner and Löhnert (2021). Radiances are noise-filtered but not averaged in time to minimize errors due to non-uniform clouds. Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a sensor attached to the ASSIST housing. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY.

17 WIND ENERGY↗

Microwave Radiometer

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). The profiles are retrieved every 10 minutes from instantaneous brightness temperature measurements at 35 channels observed with a microwave radiometer MP3000A operated by UND on the Barge for WFIP3. Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a sensor attached to the MWR housing. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY.

17 WIND ENERGY↗

BLOC Site - ASSIST Thermodynamic Retrievals TROPoe v0.18 / Derived Data

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). This is a post-processed dataset and recommended for use. The profiles are retrieved every 10 minutes from instantaneous radiances observed with an Atmospheric Sounder Spectrometer by Infrared Spectral Technology (ASSIST, Michaud-Belleau et al. 2025) operated by NOAA Physical Sciences Laboratory (PSL) on Block Island for WFIP3. The spectral bands used in the retrieval are in the wavenumber range from 612 - 905.4 cm-1 and are specified in Turner and Löhnert (2021). Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a collocated surface tower operated by NOAA PSL. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY. The TROPoe docker container (version 0.18) is available from Docker Hub at https://hub.docker.com/r/davidturner53/tropoe/tags, and the source code code is available in the GitHub repository https://github.com/OAR-atmospheric-observations/TROPoe.

17 WIND ENERGY↗