Search NASA⌕ Search

SEARCH · Search NASA

Results for “humidity pumps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Dual-module humidity pump for efficient air dehumidification: Demonstration and performance limitations

Condensation dehumidification in conventional air conditioning technologies is energy-intensive, accounting for up to 50% of building cooling energy used in some climates. Selective vacuum membrane dehumidification (VMD) is one of the leading alternative dehumidification technologies due to its potential for significant energy savings, and the “dual-module humidity pump” is one of the most promising VMD concepts. Here, this work is the first to provide experimental proof-of-concept for the dual-module humidity pump system and provides the first thermodynamic modeling framework that accounts for realistic steady-state operating limitations, both of which are lacking in the current literature. Additionally, this work is the first to provide a system design solution that overcomes practical challenges associated with air accumulation in the vacuum channels. The experimental results in this work show that the current prototype can remove up to 45% of the water vapor in the air stream, and the vapor pressure difference in the vapor rejection module needs to be approximately 2–4 times greater than that of the dehumidification module in order to maintain balanced mass transfer. The thermodynamic model applied to typical air conditioning conditions shows that the ideal dehumidification (latent) COPs can reach up to 40, but practical COPs are limited to approximately 10. Furthermore, the model shows that the overall energy efficiency increases as the membrane air selectivity increases, though this improvement gradually starts to diminish when the membrane selectivity is increased above 10,000.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Desiccants enabling energy-efficient buildings: A review

Buildings account for about 39% of the total energy consumption in the United States. Developing highly energy-efficient and environmentally friendly systems that are either actively or passively integrated into buildings plays a crucial role in decarbonizing the building sector. Among various technologies, desiccant-based energy systems have received particular attention in recent years due to their unique advantages, such as being thermally driven using low-grade waste or solar energies and being reliable over a wide range of operating ranges. Extensive research efforts have been exerted on desiccant-enabled technologies at both material and system levels aiming to increase their performance and achieve high technological readiness levels. The present review paper comprehensively discusses research works made at the system level. It overviews desiccant-based air conditioning systems, desiccant-based humidity pumps, desiccant-based thermal energy storage systems, and desiccant-based appliances. The study identifies challenges and opportunities to accelerate the commercialization of desiccant-enabled technologies. It is found that desiccant materials offer great promise to improve energy efficiency and functionality of future buildings through decoupling the latent and sensible cooling loads in air conditioning systems, humidity pumps integrated into building facades, and next-generation appliances. However, commercial viability and widespread acceptance of desiccant-based systems have been hampered by several major obstacles, including liquid and air flow mal-distribution and inferior thermo-physical properties of desiccant materials resulting in low ab/adsorption and regeneration rates and bulky/costly systems.

25 ENERGY STORAGE↗

Moisture-driven CO 2 pump for direct air capture

Direct Air Capture, the chemical separation of carbon dioxide (CO 2 ) from air, is considered a necessary approach to generate negative carbon emissions and in turn limit global warming, though energetic and monetary costs must continue to decline to meet the needed gigaton scale. The promise of energy-efficient and continuous carbon dioxide membrane separation has only recently been investigated with the development of facilitated chemical transport and novel electrochemically driven methods. This work demonstrates the potential for continuous pumping of CO 2 from air using commercial anion exchange membranes driven solely by a water vapor gradient. A reactive transport model that couples ionic transport with moisture sensitive bicarbonate chemistry in charged polymers, also termed moisture swing sorption, was developed alongside experimentally measured equilibrium and transport properties of CO 2 and water vapor in Fumasep FAA-3 to determine the mass transport limits of such a system. The results show that the commercial membrane is kinetically limited by the moisture sensitive chemistry, enabling a CO 2 current of 1.1 μmol/m 2 • s. In diffusion limited materials, a CO 2 pumping flux can reach 11 μmol/m 2 • s in and peak performance is expected with a dry air relative humidity around 50% pumping into a saturated water vapor permeate. In all configurations, water loss becomes the major cost in such a separation and must be managed through optimal polymer design or water recovery mechanisms. The work demonstrates the applicability of a new driving force, the evaporation of water, to meet the energetic demand of CO 2 separation from air.

36 MATERIALS SCIENCE↗

Thermal control extravehicular life support system

The results of a comprehensive study which defined an Extravehicular Life Support System Thermal Control System (TCS) are presented. The design of the prototype hardware and a detail summary of the prototype TCS fabrication and test effort are given. Several heat rejection subsystems, water management subsystems, humidity control subsystems, pressure control schemes and temperature control schemes were evaluated. Alternative integrated TCS systems were studied, and an optimum system was selected based on quantitative weighing of weight, volume, cost, complexity and other factors. The selected subsystem contains a sublimator for heat rejection, bubble expansion tank for water management, a slurper and rotary separator for humidity control, and a pump, a temperature control valve, a gas separator and a vehicle umbilical connector for water transport. The prototype hardware complied with program objectives.

Source record↗

Indicator Devices for Detection of Trace Gaseous Hydrazines

The relatively recent decrease in the acceptable time-weighted-average for hydrazines from 100 parts-per-billion (ppb) to 10 ppb rendered many trace hydrazine detectors either insensitive or inaccurate. Development of a rapid detection method for hydrazines at the new 10-ppb concentration was necessary so that test area personnel could reliably assess airborne hydrazines concentrations of a potentially contaminated area prior to entry. The reduction of Au(III) to Au(0) by hydrazines is a well characterized reaction and application of the corresponding yellow to purple color change was selected as a potentially useful means for detection of trace hydrazines in air. Tests with small quantities of KAuCl4 deposited on a variety of substrates were conducted using verified sources of 1,1-dimethylhydrazine, methylhydrazine, and hydrazine at approximately 10 ppb in air. Substrates tested were glass fiber filter paper, glass beads, anion exchange resin (AuCl4- form), and diatomaceous earth. The most successful of these substrates were glass fiber filter paper and diatomaceous earth. The KAuC14 impregnated glass fiber filter paper appeared to be somewhat light sensitive so further tests were conducted using the diatomaceous earth substrate. KAuCl4 concentration, substrate particle size, and sampler configuration were evaluated. Based on these tests, the device selected for further evaluation was a 5mm OD by 50mm glass tube containing 0.02-0.03g of 45/60 mesh diatomaceous earth coated with 2 percent KAuCl4. When connected to a sampling pump, response of the device to changes in relative humidity, ambient light, and high levels of other fluids, which might also be found in a propellant test area, was evaluated. False positive responses were not detected for exposures to relative humidity changes from 10 to 80 percent, sunlight for greater than 10 minutes, or percent levels of ammonia, isopropyl alcohol, nitrogen dioxide, and hydrogen. In addition, body emissions did not produce a false positive response in view of potential application for use inside protective clothing. The device was shown to reliably detect less than 10 ppb of the hydrazines tested using a 10 to 20L sample followed by a 2 to 5 minute color development time. Some field tests were conducted in parallel with conventional acidic firebrick sorbent tubes. There was generally very good agreement between the devices and firebrick sorbent tubes when greater than 10 ppb of a hydrazine was present.

Dee, Lou A.↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An atmospheric exposure chamber for small animals

The purpose of this project was to design a long-term environmental exposure chamber for small animals. This chamber is capable of producing hypoxic, normoxic and hyperoxic atmospheres which are closely regulated. The chamber, which is of the recycling type, is fashioned after clear plastic germ-free isolators. Oxygen concentration is set and controlled by a paramagnetic O2 analyzer and a 3-way solenoid valve. In this way either O2 or N2 may be provided to the system by way of negative O2 feedback. Relative humidity is maintained at 40-50 percent by a refrigeration type dryer. Carbon dioxide is absorbed by indicating soda lime. A diaphragm pump continuously circulates chamber gas at a high enough flow rate to prevent buildup of CO2 and humidity. This chamber has been used for numerous studies which involve prolonged exposure of small animals to various O2 concentrations.

Glaser, R. M.↗

RENEWABLE MARINE-SOURCE INTEGRATED HEAT PUMP FOR SPACE CONDITIONING, WATER HEATING, AND FRESH WATER HARVESTING IN REMOTE COASTAL AND ISLAND COMMUNITIES

US coastal and island communities have vulnerable energy infrastructure and high energy costs, which are exacerbated by climate change. A unique opportunity exists to use thermal energy from year-round mild temperature variations to satisfy the broad energy needs of these communities. The US Department of Energy’s Oak Ridge National Laboratory designed a small-scale marine-source integrated heat pump (MS-IHP) that, as a single appliance, combines space conditioning, dehumidification (including fresh water harvesting from humid air), and water heating for home and commercial building applications in remote coastal and island communities. The unique, innovative features of the MS-IHP offer improved efficiency and substantially reduced costs for space conditioning, dehumidification, and water heating by seamlessly integrating a heat pump, heat pump water heater, and dehumidifier by using a single compressor; optimal year-round space cooling and heating, dehumidification, water harvesting, and water heating; and improved thermal comfort and reliable operation without frosting and defrosting because of the ocean’s warm temperatures and high heat capacity. Preliminary testing was conducted by retrofitting a commercial heat pump, demonstrating an outperformed performance compared with traditional air-source heat pumps. The MS-IHP technology can help decarbonize energy systems in remote coastal and island communities.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

The effects of outdoor air-side fouling on frost growth and heat transfer characteristics of a microchannel heat exchanger: An experimental study

Air source heat pumps have the potential to efficiently heat and cool buildings, but their effectiveness in many climates is limited by frost growth on the outdoor heat exchanger in heating mode. These heat exchanger coils are also subject to fouling from fibers and particulates outdoors. Frost and fouling have each independently been studied extensively, and newly available research on fouling provides a method to realistically foul the air-side of coils in the laboratory. The current paper uses this method to conduct the first laboratory study of the important interactions between fouling and frost growth for a heat pump outdoor coil. A microchannel heat exchanger is tested clean and fouled, with variations in fouling level, humidity, and initial face velocity of air. Air flow rate is allowed to vary with resistance, and a surprising result is that light fouling increases heat transfer and frost growth rates, even with a 3.5% reduction in initial airflow caused by the fouling. However, heavier fouling decreases both rates. When frost growth is normalized to heat transfer, it is found to be increased by fouling; i.e. the coil’s sensible heat ratio decreases.

42 ENGINEERING↗

Exergy Analysis of a Convective Heat Pump Dryer Integrated with a Membrane Energy Recovery Ventilator

To increase energy efficiency, heat pump dryers and membrane dryers have been proposed to replace conventional fossil fuel dryers. Both conventional and heat pump dryers require substantial energy for condensing and reheating, while “active” membrane systems require vacuum pumps that are insufficiently developed. Lower temperature dehumidification systems make efficient use of membrane energy recovery ventilators (MERVs) that do not need vacuum pumps, but their high heat losses and lack of vapor selectivity have prevented their use in industrial drying. In this work, we propose an insulating membrane energy recovery ventilator for moisture removal from drying exhaust air, thereby reducing sensible heat loss from the dehumidification process and reheating energy. The second law analysis of the proposed system is carried out and compared with a baseline convective heat pump dryer. Irreversibilities in each component under different ambient temperatures (5–35 °C) and relative humidity (5–95%) are identified. At an ambient temperature of 35 °C, the proposed system substantially reduces sensible heat loss (47–60%) in the dehumidification process, resulting in a large reduction in condenser load (45–50%) compared to the baseline system. The evaporator in the proposed system accounts for up to 59% less irreversibility than the baseline system. A maximum of 24.5% reduction in overall exergy input is also observed. The highest exergy efficiency of 10.2% is obtained at an ambient condition of 35 °C and 5% relative humidity, which is more than twice the efficiency of the baseline system under the same operating condition.

Balaraman, Anand (ORCID:0000000218355788)↗

Interpreting Ionic Conductivity for Polymer Electrolyte Fuel Cell Catalyst Layers with Electrochemical Impedance Spectroscopy and Transmission Line Modeling

A cathode catalyst layer containing optimally distributed ionomer is critical to reduce the platinum loading and increase its utilization in polymer electrolyte fuel cells. Here, electrochemical impedance spectroscopy (EIS) was used to measure effective ionic conductivity of pseudo catalyst layers (PCLs) at a relative humidity (RH) range of 50%-120%. These results are compared to previous work using the hydrogen pump (HP) method. EIS effective ionic conductivity results reported here are higher than those from the HP because in the HP set-up ionic pathways must be effectively connected through the PCL to be counted, whereas in the EIS measurement, ionomer segments that are in contact with the membrane but are not effectively connected all the way through the PCL can be detected. Double layer capacitances and effective ionic conductivities of Pt/C catalyst layers with various supports and ionomer to carbon (I/C) ratios were studied. High surface area carbon support resulted in a lower effective ionic conductivity compared to the graphitized carbon support due to worse ionomer dispersion. Effective ionic conductivities of Pt/C layers were compared to that of PCLs. On average, effective ionic conductivities of Pt/C layers were higher than PCLs because of possible carbon agglomeratio n within the PCLs.

25 ENERGY STORAGE↗

Energy-efficient sorption-based gas clothes dryer systems

Standard electric resistance and fuel-driven dehydration technologies exhibit a maximum coefficient of performance of well below 1 mainly due to enthalpy losses associated with the air leaving the dehydration system. To improve energy efficiency, condensing dryer systems condense the moisture captured from a product in a closed-loop air circulation cycle. Existing condensing dehydration systems including heat pump dryers, however, need to significantly cool the air to achieve dehumidification. The added cooling and subsequent heating to return the air to a desired drying temperature consume substantial energy and thus reduce drying performance. Here, an innovative sorption-based gas dehydration system is proposed to overcome barriers deteriorating energy efficiency in existing gas, electric, or heat pump dryer systems. Decoupling latent and sensible loads, the system employs a liquid-desiccant solution to directly capture air humidity, thereby allowing circulation of the air in a closed loop to achieve high drying energy efficiency. In other words, the system captures waste latent heat from the moisture produced during the dehydration process and reuses it to improve energy efficiency. This study focuses on a comprehensive quasi-steady-state thermodynamic modeling of the proposed sorption-based dehydration concept employed for a gas clothes dryer application to predict transient response and overall drying performance (i.e., time and energy metrics). The analysis indicates the proposed sorption-based gas clothes dryer system can deliver a specific moisture extraction rate of 1.71 kg of water per kWh (i.e., a combined energy factor of 3.167 kg (6.98 lbm) of dry cloth per kWh) with a drying time of 44 min. This is a 112% energy improvement compared with state-of-the-art gas clothes dryers exhibiting a combined energy factor of 1.50 kg (3.3 lbm) of dry cloth per kWh. The technology pursued here can potentially be employed as a platform for many fuel-driven equipment to take advantage of available waste thermal energy in the environment instead of simply burning a fuel.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NLR HPC Facility Power Usage Effectiveness (PUE) Data

Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness

97 MATHEMATICS AND COMPUTING↗

Description of concept and first feasibility test results of a life support subsystem of the Botany Facility based on water reclamation

The Botany Facility allows the growth of higher plants and fungi over a period of 6 months maximum. It is a payload planned for the second flight of the Eureca platform around 1990. Major tasks of the Life Support Subsystem (LSS) of the Botany Facility include the control of the pressure and composition of the atmosphere within the plant/fungi growth chambers, control of the temperature and humidity of the air and the regulation of the soil water content within specified limits. Previous studies have shown that various LSS concepts are feasible ranging from heavy, simple and cheap to light, complex and expensive solutions. A summary of those concepts is given. A new approach to accomplish control of the temperature and humidity of the air within the growth chambers based on water reclamation is discussed. This reclamation is achieved by condensation with a heat pump and capillary transport of the condensate back into the soil of the individual growth chamber. Some analytical estimates are given in order to obtain guidelines for circulation flow rates and to determine the specific power consumption.

Loeser, H. R.↗

In-Line Capacitance Sensor for Real-Time Water Absorption Measurements

A capacitance/dielectric sensor was designed, constructed, and used to measure in real time the in-situ water concentration in a desiccant water bed. Measurements were carried out with two experimental setups: (1) passing nitrogen through a humidity generator and allowing the gas stream to become saturated at a measured temperature and pressure, and (2) injecting water via a syringe pump into a nitrogen stream. Both water vapor generating devices were attached to a downstream vertically-mounted water capture bed filled with 19.5 g of Moisture Gone desiccant. The sensor consisted of two electrodes: (1) a 1/8" dia stainless steel rod placed in the middle of the bed and (2) the outer shell of the stainless steel bed concentric with the rod. All phases of the water capture process (background, heating, absorption, desorption, and cooling) were monitored with capacitance. The measured capacitance was found to vary linearly with the water content in the bed at frequencies above 100 kHz indicating dipolar motion dominated the signal; below this frequency, ionic motion caused nonlinearities in the water concentration/capacitance relationship. The desiccant exhibited a dielectric relaxation whose activation energy was lowered upon addition of water indicating either a less hindered rotational motion or crystal reorientation.

Nurge, Mark A.↗

BioBot: Innovative Offloading of Astronauts for More Effective Exploration

The BioBot concept consists of a robotic rover which is capable of traversing the same terrain as a spacesuited human. It carries the primary life support system for the astronaut, including consumables, atmosphere revitalization systems (e.g., CO2 scrubbing, humidity and temperature management, ventilation fan), power system (e.g., battery, power management and distribution),and thermal control system (e.g., water sublimator, cooling water pump), along with umbilical lines to connect to the supported astronaut. Although not technically part of life support, it would be logical for the BioBot to also provide long-range communications, video monitoring, tool and sample transport, and other functions to enable and enhance EVA productivity in planetary surface exploration.The design reference scenario for this concept is that astronauts involved in future lunar or Mars exploration will be on the surface for weeks or months rather than days, and will be involved in regular EVA operations. It is not unreasonable to think of geologists spending several days inEVA exploration each week over a prolonged mission duration, with far more ambitious operational objectives than were typical of Apollo. In this scenario, each astronaut will be accompanied by a "BioBot", which will transport their life support system and consumables, an extended umbilical and umbilical reel, and robotic systems capable of controlling the position and motion of the umbilical. The astronaut will be connected to the robot via the umbilical, carrying only a small emergency open-loop life support system similar to those contained in every PLSS. The robotic mobility base will be designed to be capable of traveling anywhere the astronaut can walk, and will also be useful as a transport for the EVA tools, science instrumentation, and collected samples. In addition, the BioBot can potentially carry the astronaut on traverses as well. Such a system will also be a significant enhancement to public engagement in these future exploration missions, as the robotic vehicles can also support high-resolution cameras and high bandwidth communications gear to providehigh-definition video coverage of each crew throughout each EVA sortie.

Akin, David L.↗

Regenerable Liquid Desiccants for High Efficiency Humidity Control in Microgravity

The NASA X-Hab project aims to design, manufacture, test, and prove functionality of an air humidity control subsystem to dehumidify and re-humidify air from a space cabin. The method of regulating cabin air humidity utilizes vortex phase separation, which uses an ionic liquid (IL) desiccant for air-water phase separation. This subsystem is intended to be integrated with a CO 2 removal system requiring de-humidified air to operate efficiently. The air humidity control subsystem is composed of a cold-desiccant or cold-side Vortex Phase Separator (VPS) that dehumidifies the cabin air. The dehumidified air exits the cold-side (CS) VPS chamber to flow into the CO 2 removal module, and the cold, water-laden liquid desiccant flows to a regenerative heat exchanger. From the heat exchanger the liquid desiccant continues to the heater. After heating, the desiccant flows into a hot-desiccant or hot-side (HS) VPS as the dehumidified air from CO 2 removal module enters through the HS VPS air inlet. The rehumidified air exits the HS VPS into the space cabin. One pump installed at the liquid exit of the CS VPS and one pump installed at the liquid exit of the HS VPS transport the fluid through the system. To evaluate the system’s efficiency and effectiveness, the temperature, pressure, flow rate and relative humidity are read, recorded, and analyzed at critical points along the module.

Gerardo Castro↗