SEARCH · Search NASA
Results for “hybrid heating”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Hybrid Heat Exchangers
A hybrid light-weight heat exchanger concept has been developed that uses high-conductivity carbon-carbon (C-C) composites as the heat-transfer fins and uses conventional high-temperature metals, such as Inconel, nickel, and titanium as the parting sheets to meet leakage and structural requirements. In order to maximize thermal conductivity, the majority of carbon fiber is aligned in the fin direction resulting in 300 W/m.K or higher conductivity in the fin directions. As a result of this fiber orientation, the coefficient of thermal expansion (CTE) of the C-C composite in both non-fiber directions matches well with the CTE of various high-temperature metal alloys. This allows the joining of fins and parting sheets by using high-temperature braze alloys.
Hybrid Heat Pipes for Lunar and Martian Surface and High Heat Flux Space Applications
Novel hybrid wick heat pipes are developed to operate against gravity on planetary surfaces, operate in space carrying power over long distances and act as thermosyphons on the planetary surface for Lunar and Martian landers and rovers. These hybrid heat pipes will be capable of operating at the higher heat flux requirements expected in NASA's future spacecraft and on the next generation of polar rovers and equatorial landers. In addition, the sintered evaporator wicks mitigate the start-up problems in vertical gravity aided heat pipes because of large number of nucleation sites in wicks which will allow easy boiling initiation. ACT, NASA Marshall Space Flight Center, and NASA Johnson Space Center, are working together on the Advanced Passive Thermal experiment (APTx) to test and validate the operation of a hybrid wick VCHP with warm reservoir and HiK"TM" plates in microgravity environment on the ISS.
Advanced Modular Sub-Atmospheric Hybrid Heat Engine (Final Report)
The Phase 1 Final Technical Report describes the results of the work completed during the “Advanced Modular Sub-Atmospheric Hybrid Heat Engine” project. A key part of the Phase 1 work was the completion of a thermodynamic cycle analysis for the MHHE at the selected module size. The hybrid heat engine has been developed as a modular unit (sized in the range of 500kW – 60MW) that can be used with modular coal or biomass gasifiers, with distributed power generation systems, with large power plants comprised of multiple generating units, and with natural gas compression stations. The MHHE will provide cleaner, more efficient, and lower cost generation with better load following capabilities than existing competing technologies with a singular generating source such as solar farm, gas turbine, or combustion engine. The drivers of the MHHE technology are: benefits of modular power generation (reduced equipment cost, construction cost and implementation time, connection ready on delivery, flexible scalability, serviceability), fuel flexibility, lowest cost power generation and reduced emissions.A logical progression of work and a clear path forward toward meeting the FOA goals and objectives have been established. Namely, a preliminary market analysis and primary fuel identification was completed first and then the modularity of the system was defined. The benefits of the proposed hybrid and modular heat engine were described when applied to modular coal gasifiers, distributed power generators, and larger power plants. Based on the market analysis, modularity, and chosen primary fuel, a conceptual design and layout of the hybrid heat engine was developed, analyzed, and characterized. The technology gaps already identified have been reviewed and expanded upon, and a test plan to address these gaps through bench scale testing in Phase 2 has been developed. Cost estimate methodology and considerations in support of a potential Phase 2 project have been described.
Advanced Modular Sub-Atmospheric Hybrid Heat Engine (Phase 1 Final Report)
The Phase 1 Final Report describes the results of the work completed during the “Advanced Modular Sub-Atmospheric Hybrid Heat Engine” project. The objectives of Phase 1 work were to develop a conceptual design of the turbine-based modular hybrid heat engine (MHHE), including thermodynamic cycle analysis, define the nominal engine component boundary conditions, identify technology gaps, and develop a detailed test plan to address these gaps through bench scale testing in a potential subsequent Phase 2 project. To achieve the project objective, the following activities were performed in Phase 1 work: (1) Market analysis and primary fuel selection, (2) Conceptual design and integrated layout development, (3) Design support and key components characterization, (4) Planning to move technology to pre-commercial demonstration.
THE DEVELOPMENT OF A HEATED-HYBRID GENERATED GAS PRESSURIZATION SYSTEM FOR PROPELLANT TANKS
Heated-hybrid generated gas pressurization system for liquid propellant transfer in rocket vehicles
Joining Techniques for Novel Metal Polymer Hybrid Heat Exchangers
In the United States, over 50% of the unrecovered energy from industrial processes is in the form of low-grade heat (< 220°C). Materials and maintenance costs of common heat exchangers are typically too high to justify their usage. Polymers, though more affordable, are usually unsuitable for HX applications due to their low thermal conductivity (~0.2 W/mK). Here, we show that metal-polymer hybrids may be attractive from both performance and cost perspectives. The use of polymers further increases the resistance to corrosion by sulfuric and carbonic acids often present in flue gases. An ongoing work explores different configurations of layered polyimide-copper macroscale hybrids for heat exchanger applications using numerical simulations. This paper explores a manufacturing pathway for producing such layered hybrid tubes that involves directly rolling and bonding tapes made of polymer and copper foil into tubes. A critical problem in the fabrication process is the bonding of metal and polymers. We explore approaches involving adhesives (epoxy, acrylic and silicone) for metal/polymer interfaces and direct welding (ultrasonic) for metal/metal interfaces that can be integrated into the manufacturing process. We report characterizations of the thermomechanical properties of these joining processes. This work paves the way for realizing cost-effective manufacturing of heat exchangers for low grade waste heat recovery.
Operational space for lower hybrid heating scenarios in the full tungsten environment of WEST
In tungsten—W—Environment in Steady-state Tokamak (WEST), the lower hybrid current drive (LHCD) system is key for achieving long pulse operation by providing most of the non-inductive plasma current, as well as a crucial source of electron heating. Therefore, determining the operational space for its application is fundamental. In the present study, the LHCD operational space is deeply analyzed for 0.5 MA pulses. This space is bounded by three limits: (i) the ratio of the LHCD power over density must be above a threshold to compensate tungsten radiation with enough core heating, (ii) the line-averaged density must be high enough to allow good coupling of the hybrid wave with the plasma, and (iii) fast electron ripple losses must be below a limit to avoid reaching a thermal threshold on plasma-facing components. If the tungsten radiation peak or burn-through phase is not safely overcome, a maximum electron temperature of 1.5 keV is obtained, confinement is degraded, and magnetohydrodynamic activity is frequently triggered, potentially causing a disruption. From experimental measurements and interpretative simulations, we highlight the main mechanisms that prevent the plasma from heating up during LHCD power ramp-up. Three parameters play a major role: plasma density, tungsten concentration and LHCD power deposition. A strategy to overcome this limitation is found: a precise density ramp-up performed simultaneously with the increase in LHCD power. Additionally, we show that boronization greatly facilitates the burn-through of tungsten by lowering its content during the heating phase. Finally, taking into account the three constraints given above, the LHCD operational space is determined at power ramp-up and during constant heating phases.
Lower hybrid heating of ionospheric ions due to ion ring distributions in cusp
The stability of H(+) and H(++) ring distributions which have been observed downflowing into the cusp on the DE and S3-3 satellites is examined in the context of the feedback of those instabilities on plasma of ionospheric origin consisting of (H(+) and O(+). Lower hybrid waves are excited by the ring distributions in three distinct phases of wave-particle interaction: linear growth, trapping, and quasi-linear diffusion.The latter phase accounts for most particle heating. Including background O(+) and/or a He(++) ring introduces new modes not present in a pure H(+) plasma which play an important role in heating heavier ions. O(+) is heated significantly more by a He(++) ring than a H(+) ring of comparable energy density. It is suggested that lower hybrid waves generated by downflowing ion ring distributions play a role in energizing ion conics in the cusp.
Oblique microchannel merged with circle micro pin-fin as a novel hybrid heat sink for cooling of electronic devices
Not Available
Validation of a Co-Optimized, Smart Hybrid Heat Pump Control
This study examines a residential dual fuel (DF) heating system that integrates heat pump and gas furnace technology with a home’s forced-air distribution ducts. Specifically, it explores a retrofit where an “add-on” heat pump replaces the air conditioning (A/C) system and is combined with the home’s existing furnace and air handler. The research team developed and validated an innovative control scheme for this integrated DF system that selected the more economical heating source (furnace or heat pump) while maintaining comfort in the home. The project’s field study and subsequent modeling analysis show that this control scheme can decrease energy use, cost, and emissions compared to a furnace-only system. As homes in mixed and cold climates transition to more electric space heating, furnace-to-dual fuel system retrofits offer a solution that can alleviate the retrofit costs, energy cost concerns, and peak load impacts of full electrification.
Hybrid Heat Pump Controls: Conventional Dual Fuel versus Seamlessly Fuel Flexible Heat Pump
This paper compares the performance of a novel seamlessly fuel flexible heat pump (SFFHP) and conventional dual fuel heat pump (DFHP) for space heating. The conventional dual fuel systems either run on the gas furnace or electric heat pump at any given moment, as a comparison, the proposed seamlessly fuel flexible heat pump simultaneously consumes gas and electricity by continuously optimizing the proportion of each. The process air flows across the heat pump condenser first and then flows across the furnace coil, therefore, the heat pump temperature lift is reduced. SFFHP delivers energy savings by allowing each subsystem, i.e., gas furnace and electric heat pump, to operate where it performs best.For DFHP, two operation control strategies, i.e., non-restricted control and restricted control, are available on market. For the non-restricted mode, the thermostat has a switching temperature-programmed according to the balancing point of heating load and capacity curve. Heat pump operates above the switching temperature, while the furnace takes over under the switching temperature. For the restricted control, the compressor of a heat pump is disabled below a predefined lockout outdoor temperature to let the furnace take over. For SFFHP, a model predictive control strategy is developed to continuously adjust the capacities of the electric heat pump and gas furnace based on the foreseen weather data, utility price signals, and marginal grid emission signals with the goal of minimizing the utility cost and CO2 emission while guaranteeing comfort requirements.In this paper, DFHP and SFFHP are simulated using high-fidelity heat pump performance curves generated from DOE/ORNL heat pump design model. Performance comparison of DFHP and SFFHP during 2019-2020 heating season in Los Angeles shows that SFFHP with model predictive control achieves 23% utility cost reduction and 17 % CO2 emission reduction. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. As a result, SFFHP can deliver superior benefits for utility cost reduction and CO2 emission reduction over conventional dual fuel heat pump.
An Affordable, Minimum-carbon Hybrid Heat Pump with a Grid Responsive Retrofittable Controller
Explore the source record for details and available documents.
Porous ceramic supports for resistively heated hybrid gas sorbents
A porous sorbent ceramic product includes a three-dimensional structure having an electrically conductive ceramic material, wherein the conductive ceramic material has an open cell structure with a plurality of intra-material pores, a sorbent additive primarily present in the intra-material pores of the conductive ceramic material for adsorption of a gas, and at least two electrodes in electrical communication with the conductive ceramic material.
Low-Carbon District Heating: Performance Modeling of Hybrid Solar, Heat Pump, and Thermal Storage Systems for District Thermal Energy in the United States
District heating requires thermal energy in the temperature range of 40 degrees C - 120 degrees C. Typically, the thermal energy input for these systems has largely been met through fossil energy. However, the temperature range is low enough that it presents an opportunity for low-carbon technologies such as solar thermal and electrified thermal generators like heat pumps to decarbonize the heat generation. In this paper, a heat pump model was applied to estimate the performance and economics of a real-world low-carbon district heating substation. This system is comprised of a flat plate solar collector field paired with a mechanical vapor compression heat pump and hot water thermal storage, augmented by gas-fired boilers. Plant data was used to tune the model and estimate the system's benefits in terms of both standard financial metrics (IRR and payback), and environmental metrics, including avoided CO2 emissions. The model is subsequently employed to estimate the technical and economic potential of solar + heat pump + ther-mal storage hybrid systems as retrofits for district heating systems in eight US Markets.
Hybrid Solar Thermal Energy System for District Heating Application
Solar district heating (SDH) systems can be good alternatives to conventional systems when they are optimized with hybrid configurations and thermal energy storage (TES). In this scope, a hybrid renewable thermal energy system (RTES) model has been built combining flat plate collector (FPC) solar system with parabolic trough collector (PTC) system via a heat exchanger and coupled with TES. To undertake the hybridization of the system, System Advisor Model (SAM) software was modified, which allowed control over configurations and more accurate modelling of heat transfer between the collectors. The model is first compared to an existing hybrid solar district heating systems (DHS) system in Taars, Denmark. The results showed a good correlation with an overestimation of only 6.4% compared to most recent heat output. Then the same system configuration was modeled in different geographic locations to investigate the impact of changes in direct normal irradiance (DNI) to the heat sink thermal output of the hybrid system. The results showed that the annual net thermal power output in California, USA can be three times more than the annual net thermal power output in Taars, Denmark. Finally, multiple hybrid configurations with varying solar field sizes were simulated based on the heat demand of two different university campuses DHS. The results showed that, retrofit applications of this hybrid DHS system coupled with TES could reduce the natural gas consumption of the existing systems between 25% and 41%. The use of hybrid RTES highlighted in this paper can be extended to many more opportunities.
Waste heat recovery hybrid power drive
A waste heat recovery (WHR) hybrid power system can be utilized in vehicles to convert heat energy into mechanical energy. The WHR system can include a WHR power unit structured to convert thermal energy into rotation of a WHR drive shaft. A motor/generator having a motor/generator shaft can selectively operate as a motor or a generator. A mechanical linkage can be structured to selectively link a output shaft to one of the WHR drive shaft and the motor/generator drive shaft independently of the other of the WHR drive shaft and the motor/generator drive shaft.
Waste heat recovery hybrid power drive
A waste heat recovery (WHR) hybrid power system can be utilized in vehicles to convert heat energy into mechanical energy. The WHR system can include a WHR power unit structured to convert thermal energy into rotation of a WHR drive shaft. A motor/generator having a motor/generator shaft can selectively operate as a motor or a generator. A mechanical linkage can be structured to selectively link a output shaft to one of the WHR drive shaft and the motor/generator drive shaft independently of the other of the WHR drive shaft and the motor/generator drive shaft.