Search NASA⌕ Search

SEARCH · Search NASA

Results for “hydrogen refueling station”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigation of precooling unit design options in hydrogen refueling station for heavy-duty fuel-cell electric vehicles

Precooling gaseous hydrogen fuel to a cold temperature before refueling a heavy-duty (HD) hydrogen fuel cell electric vehicle (HFCEV) is essential to avoid overheating the vehicle tank, as well as achieving a high state of charge (SOC). Because a large volume of hydrogen is dispensed during each fill, the need for a shorter fill time amplifies the need to precool each load for refueling a HFCEV. Thus, the design and operation of a precooling unit (PCU), as well as the associated capital and operating costs, plays a pivotal role in any plans for heavy-duty hydrogen refueling stations. Here, in this paper, we present a thermodynamic and technoeconomic analysis of a PCU in a gaseous hydrogen refueling station (HRS) for HD HFCEVs. By employing Argonne National Laboratory's hydrogen station cost optimization and performance evaluation (H2SCOPE) model, the refueling of 50 kg of hydrogen on-board type IV tank at ambient temperatures of 15–45 °C and varying fill rates is simulated. The required degree of precooling temperature to obtain either 100% or the maximum possible SOC is obtained from the simulation. Additionally, the simulation results demonstrate that the average flow rate of hydrogen is approximately 40% lower than the maximum flow rate during a typical fill; which motivates further evaluation of the instantaneous hydrogen mass flow rate profile and suggests the scope of improving precooling unit design. Accordingly, a hybrid strategy of precooling hydrogen has been proposed to address the cooling load by sizing the refrigeration unit for the average flow rate of hydrogen, while supplementing the above average peak hydrogen flow cooling load through thermal buffering. The combined technique enables the downsizing of the original PCU capacity by 25–40% and demonstrates a potential cost reduction of the PCU by approximately 30%, which translates to an installed cost reduction of ∼$125,000 per dispenser.

25 ENERGY STORAGE↗

Providing Levelized Cost and Waiting Time Inputs for HDV Hydrogen Refueling Station Planning: A Case Study of U.S. I-75 Corridor

Widespread use of diesel fuels in freight transportation leads to greenhouse gas (GHG) emissions that play an important role in air pollution. The air pollution, as well as the energy crisis, drives the transition from diesel fuel to cleaner and more energy-efficient fuels such as hydrogen fuels. With such a transition, the strategic planning and optimization of supporting refueling infrastructure along the national highway for heavy-duty vehicles (HDVs) become a necessity. Cost and service level are two essential factors to be considered in hydrogen refueling station location and capacity optimization. The service level in this study is assessed by the delay (waiting time) at fueling stations as well as the fueling demand fulfilled. To this end, this study presents a methodology to provide waiting time (delay) and levelized hydrogen fuel cost inputs under different station configurations (number of dispensers and fill rates) for hydrogen refueling station planning. Determining the station configurations based on the trade-off between the two inputs is further discussed. Particularly, this study points out that the levelized cost and waiting time are affected by hourly demand patterns and estimates the two inputs under different peak hour fueling demand scenarios. The results suggest that, with the same daily demand, the cost, as well as the waiting time, increases obviously with the peak hour demand. In the case study, the cost grows at least 30% when the peak hour visit frequency of the daily total visits increases from 5% (evenly distributed pattern) to 10% (the most common pattern for existing diesel fueling stations along I-75). Accounting for this peak hour effect in hydrogen refueling station planning is recommended. Overall, the waiting time model and cost analysis provide key inputs for optimizing hydrogen refueling station location and configurations based on anticipated refueling demand patterns. The paper is the second in a series that aims to build a comprehensive modeling plan and optimize hydrogen refueling infrastructure along the Interstate 75 (I-75) corridor for HDVs.

Liu, Yuandong↗

Empirically verified analysis of dual pre-cooling system for hydrogen refuelling station

The dual cooling system at the California State University Los Angeles Hydrogen Research and Fueling Facility is analysed to predict the output hydrogen temperature in different ambient conditions. Initially, the facility was built with a coil chiller T20 cooling, sufficient for occasional fuelings. A flat plate evaporator system was added in series to resolve any issues for multiple fuelings even in the hottest weather. This study was commenced to verify the set points and determine the control requirements for the dual setup in order to inform future designs. A numerical-empirical model of the cooling system was developed by reverse engineering, using the station experimental measurements and database records. The subsystems are characterized separately but validated as a whole system imposing specific and standard operating conditions. The cooling model is tested with different inputs to validate the pre-set parameter variation of the cooling components. Ten scenarios were investigated to evaluate the fueling output parameters, testing two hydrogen temperature input trends (according to the facility initial conditions) and five ambient temperatures (from 15 °C to 35 °C). In closing, the simulation results have confirmed that the hydrogen output temperature remains within the range imposed by the SAE J2601 for each scenario studied, around -22 °C and -25 °C.

08 HYDROGEN↗

Next Generation Multi-Use Heavy-Duty High-Flow Direct-Fill Hydrogen Refueling Station with Standardized Design (CRADA Final Report)

The Contractor will build a liquid hydrogen (LH2) fueling station model that is capable of simulating the amount of hydrogen transferred from the liquid storage tank to the vehicle, depending on the station’s design and control scheme. This modeling work will allow the Parties to seek the design and control scheme of an LH2 station that can fill a targeted number of vehicles while meeting a time-average flow rate of 10 kg/min for each fill. While evaluating a high dispensing performance station design and control scheme, the Contractor will analyze the design and control scheme are economically viable.

08 HYDROGEN↗

Efficient and Safe Hydrogen Refueling of Fuel Cell Vehicles from an Emergency Chemical Hydride Storage Source

Zero-emissions hydrogen fuel cell electrical vehicles (FCEVs) have become more popular in recent years. However, the limited availability of hydrogen fueling stations is considered a critical barrier to sustainable adoption of hydrogen FCEV. To enable the widespread deployment and commercialization of hydrogen FCEV, the availability of hydrogen refueling stations needs to improve. One of the consequences of the lack of hydrogen refueling infrastructure is that consumers can suffer from “range anxiety”, meaning consumers would get anxious of running out of fuel during long-distance trip [4]. A practical solution is to provide a compact emergency hydrogen refueler that can be used if the consumer runs out of hydrogen before reaching the nearest hydrogen refueling station. A safe, compact, and user-friendly hydrogen refueler would give consumers the flexibility they need to feel comfortable using their hydrogen FCEV when planning a long-distance trip. Offering this product would alleviate range anxiety, and it would make Hydrogen FCEV a more attractive alternative to gasoline vehicles. The emergency hydrogen refueler consists of a lithium hydride bed that reacts with liquid water to produce hydrogen gas and lithium hydroxide.

08 HYDROGEN↗

Hydrogen Refueling Reference Station Lot Size Analysis for Urban Sites

Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) is a project initiated by the DOE in 2015 and executed by Sandia National Laboratories and the National Renewable Energy Laboratory to address R&D barriers to the deployment of hydrogen fueling infrastructure. One key barrier to the deployment of fueling stations is the land area they require (i.e. "footprint"). Space is particularly a constraint in dense urban areas where hydrogen demand is high but space for fueling stations is limited. This work presents current fire code requirements that inform station footprint, then identifies and quantifies opportunities to reduce footprint without altering the safety profile of fueling stations. Opportunities analyzed include potential new methods of hydrogen delivery, as well as alternative placements of station technologies (i.e. rooftop/underground fuel storage). As interest in heavy-duty fueling stations and other markets for hydrogen grows, this study can inform techniques to reduce the footprint of heavy-duty stations as well. This work characterizes generic designs for stations with a capacity of 600 kg/day hydrogen dispensed and 4 dispenser hoses. Three base case designs (delivered gas, delivered liquid, and on-site electrolysis production) have been modified in 5 different ways to study the impacts of recently released fire code changes, colocation with gasoline refueling, alternate delivery assumptions, underground storage of hydrogen, and rooftop storage of hydrogen, resulting in a total of 32 different station designs. The footprints of the base case stations range from 13,000 to 21,000 ft 2 . A significant focus of this study is the NFPA 2 requirements, especially the prescribed setback distances for bulk gaseous or liquid hydrogen storage. While the prescribed distances are large in some cases, these setback distances are found to have a nuanced impact on station lot size; considerations of the delivery truck path, traffic flow, parking, and convenience store location are also important. Station designs that utilize underground and rooftop storage can reduce footprint but may not be practical or economical. For example, burying hydrogen storage tanks underground can reduce footprint, but the cost savings they enable depend on the cost of burial and the cost land. Siting and economic analysis of station lot sizes illustrate the benefit of smaller station footprints in the flexibility and cost savings they can provide. This study can be used as a reference that provides examples of the key design differences that fueling stations can incorporate, the approximate sizes of generic station lots, and considerations that might be unique to particular designs.

08 HYDROGEN↗

Reference Station Risk Assessment for Refueling Heavy-Duty Vehicles Using HyRAM+

The deployment of heavy-duty (HD) hydrogen fuel cell vehicles that are entering the market now is driving the need for expanded HD hydrogen refueling station infrastructure to meet demand. This expansion must prioritize safety and reliability, necessitating careful consideration of the associated risks. In this study, we use a light-duty (LD) hydrogen refueling station as a comparative tool to quantify the risks for a HD station, which is essentially a scaled-up version of a LD station.

08 HYDROGEN↗

Hydrogen and Electric Charging Infrastructure for Heavy-Duty Trucks: A Nationally Scalable Megaregion Assessment

Decarbonizing regional and long-haul freight is challenging due to the limitations of battery-electric commercial vehicles and infrastructure constraints. Hydrogen fuel cell medium- and heavy-duty vehicles (MHDVs) offer a viable alternative, aligning with the decarbonization goals of the Department of Energy and commercial entities. Historically, alternative fuels like compressed natural gas and liquefied propane gas have faced slow adoption due to barriers like infrastructure availability. To avoid similar issues, effective planning and deploying zero-emission hydrogen fueling infrastructure is crucial. This research develops deployment plans for affordable, accessible, and sustainable hydrogen refueling stations, supporting stakeholders in the decarbonized commercial vehicle freight system. It aims to benefit underserved and rural energy-stressed communities by improving air quality, reducing noise pollution, and enhancing energy resiliency. This research also provides a blueprint for replacing diesel in over-the-road Class 8 freight truck applications with hydrogen fueling solutions. The study focuses on the Texas Triangle Megaregion (I-45, I-35, and I-10), the I-10 corridor between San Antonio, TX, and Los Angeles, CA, and the I-5/CA-99 corridors between Los Angeles, CA, and San Francisco, CA. This area represents a significant portion of U.S. heavy-duty freight movement, carrying ~8.5% of the national freight volume. Using the OR-AGENT (Optimal Regional Architecture Generation for Efficient National Transport) modeling framework, the study conducts an advanced assessment of commercial vehicles, road and freight networks, and energy systems. The framework integrates data on freight mobility, traffic, weather, and energy pathways to deliver a region-specific, optimized vehicles powertrain architectures, infrastructure deployment solutions, operational logistics, and energy pathways. By considering all vehicle origin-destination pairs utilizing these corridors and all feasible fueling station location options, the framework's genetic algorithm identifies the minimum number and optimal locations of hydrogen refueling stations, ensuring no vehicle is stranded. It also determines fuel schedules and quantities at each station. A roadmap for station deployment based on multiple adoption trajectories ensures a strategic rollout of hydrogen refueling infrastructure.

Sujan, Vivek [ORNL] (ORCID:0000000269882342)↗

Development of an Electrochemical Hydrogen Contaminant Detector

Hydrogen refueling stations (HRSs) that dispense hydrogen to fuel cell vehicles need to ensure the quality of hydrogen to avoid contamination of the vehicle’s expensive fuel cell stacks. Currently, stations verify their fuel quality only periodically to ensure that they meet the strict fuel quality standards specified by either International Organization for Standards (ISO) or Society for Automotive Engineers (SAE). The development of hydrogen contaminant detectors (HCDs) that can provide low cost continuous monitoring at the HRS can be an invaluable asset in protecting fuel cell vehicles from any fuel contamination in-between infrequent expensive analysis of hydrogen fuel quality. An HCD capable of detecting < 200 ppb of CO in hydrogen is presented in this paper. The HCD is based on an electrochemical hydrogen pumping cell whose ultra-low loaded working electrode is poisoned by the contaminant, thus reducing its hydrogen oxidation reaction rate. The hydrogen pumping cell consists of a Nafion® membrane, a sputtered Pt working electrode, a Pt/Ru counter/pseudo-reference electrode and an internal water wicking system that provides humidification to the membrane and electrodes. When this HCD is operated in a pulsed voltammetry mode, it can provide stable CO response for thousands of hours in a HRS.

47 OTHER INSTRUMENTATION↗

Operational optimization for multi-functional charging station with electric and hydrogen-powered vehicles

The rapid adoption of electric vehicles (EVs) and hydrogen fuel cell vehicles (HFCVs), combined with global efforts to reduce carbon emissions, has accelerated the development of EV charging and hydrogen refueling stations. In response to this demand, this paper introduces the concept of Multi-Functional Charging Station (MFCS) that integrates power generation, EV charging, battery swapping, and hydrogen refueling. A comprehensive operational model is developed for the MFCS that couples electricity and hydrogen conversion and storage technologies to enhance infrastructure utilization and improve overall system efficiency. The model also considers multiple revenue streams, including participation in energy and ancillary markets. To validate the effectiveness of the proposed model and evaluate its performance, a series of numerical experiments are conducted with different charger numbers, different electricity purchase limits, and different charger allocations. Numerical results demonstrate that shared charger configurations can lead to 8.11 % improvement in operational profit by improving resource utilization and reducing the number of depleted batteries at the end of operations compared to allocated charger setups. By varying the number of chargers, sensitivity analysis identifies diminishing marginal returns beyond about 45 chargers, suggesting it as an optimal sizing point under current settings. The integration of electricity and hydrogen conversion is also explored under scenarios with limited external electricity purchases. In conclusion, these findings indicate that optimizing charger allocation and energy management can significantly enhance station productivity and profitability, ultimately supporting the broader adoption of electrified and hydrogen-based transportation solutions.

Charging station↗

Thermodynamic parametric analysis of refueling heavy-duty hydrogen fuel-cell electric vehicles

Reliable design and safe operation of heavy-duty hydrogen refueling stations are essential for the successful deployment of heavy-duty fuel cell electric vehicles (FCEVs). Fueling heavy-duty FCEVs is different from light-duty vehicles in terms of the dispensed hydrogen quantities and fueling rates, requiring tailored fueling station design for each vehicle class. In particular, the selection and design of the onboard hydrogen storage tank system and the fueling performance requirements influence the safe design of hydrogen fueling stations. A thermodynamic modeling and analysis are performed to evaluate the impact of various fueling parameters and boundary conditions on the fueling performance of heavy-duty FCEVs. Here, we studied the effect of dispenser pressure ramp rate and precooling temperature, initial tank temperature and pressure, ambient temperature, and onboard storage design parameters, such as onboard storage pipe diameter and length, on the fueling rate and final vehicle state-of-charge, while observing prescribed tank pressure and temperature safety limits. An important finding was the sensitivity of the temporal fueling rate profile and the final tank state of charge to the design factors impacting pressure drop between the dispenser and vehicle tank, including onboard storage pipe diameter selection, and flow coefficients of nozzle, valves, and fittings. The fueling rate profile impacts the design and cost of the hydrogen precooling unit upstream of the dispenser.

08 HYDROGEN↗

Next Generation Hydrogen Station Analysis

This presentation was part of the U.S. Department of Energy Hydrogen Program's Annual Merit Review and Peer Evaluation Meeting, reporting on project TA042, hydrogen refueling station evaluation.

CDP↗

Hydrogen Contamination Detector: Protecting the future of zero-emission fuel cell energy [Brief]

Los Alamos National Laboratory developed an electrochemical detector to protect zero-emission hydrogen fuel cells from contaminated fuels. Fuel cells power environmentally clean vehicles, fork lifts, drones, and provide auxiliary power. High-purity hydrogen is essential to avoid poisoning fuel cells. Current analysis methods are costly and cannot detect impurities in realtime. The Hydrogen Contamination Detector measures the two highest impact Department of Energy-identified impurities with a simple, low-cost unit that provides 24/7, point-of-service analysis. Los Alamos partnered with H2Frontiers to conduct field trials at hydrogen refueling stations and with Skyre LLC for commercialization through a DOE Technology Commercialization Fund project.

08 HYDROGEN↗