SEARCH · Search NASA
Results for “hydrogen sensors”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Low-cost, Robust, Miniaturized Hydrogen Sensors for Continuous Hydrogen Monitoring
Explore the source record for details and available documents.
NREL Hydrogen Sensor Testing Laboratory and Smart Hydrogen Wide Area Monitoring
The NREL Hydrogen sensor laboratory aims to ensure that hydrogen sensor technology is available to meet end-user needs and to foster the proper use of sensors by advancing next generation sensing and analysis techniques, supporting codes and standards development, and improving component reliability systems.
Mitigating humidity interference in chemiresistive hydrogen sensors through hydrophobic surface functionalization
Chemiresistive gas sensors based on semiconductor metal oxides, such as tin dioxide (SnO₂), are indispensable for detecting and monitoring toxic gases and pollutants, making them critical components in industrial and environmental applications. To enhance their performance, the metal oxides are loaded with noble metals such as palladium (Pd). However, ambient humidity poses a significant challenge to their performance. The presence of adsorbed water molecules on the oxide surface can considerably impair sensor sensitivity and overall performance. To address this issue, in this paper, we report on the application of an ultrathin, hydrophobic layer of hexamethyldisilazane to the surface of a Pd/SnO 2 sensor. This study investigates the influence of hydrophobic surface modifications on the metal oxide interface, focusing on their impact on sensor sensitivity and selectivity. The resulting sensor exhibits superior hydrogen sensing capabilities, operating effectively at low temperatures even in high humidity environments. Furthermore, the hydrophobic modification reduces the sensor’s susceptibility to interfering gases, thus enhancing its selectivity. The combined enhancements in moisture resistance and selectivity achieved through HMDS surface modification, along with the superior sensitivity of Pd/SnO₂ sensors, facilitate the development of gas sensors with enhanced humidity tolerance and broader applications.
NREL Hydrogen Sensor Testing Laboratory
Relevance: Detection is recognized as a critical element for hydrogen facility safety design and supports risk mitigation. Detection methodologies will support validation of H2 behavior research. Hydrogen point sensors play a critical role for safety and process monitoring, but other methodologies can be developed. Approach: NREL Sensor Laboratory tests and verifies sensor performance for manufacturers, developers, end-users, regulatory agencies and SDOs/CDOs NREL deployment activity supports regulatory requirement verification, hydrogen behavior models, and method development for use by stakeholders. Accomplishments and Progress: NREL's R&D accomplishments have supported developers, industry, and SDOs by providing sensor performance and deployment expertise not otherwise available. Development of alternative detection strategies for hydrogen applications have been initiated. HyWAM and advanced detection methodologies deployments at H2@Scale Facilities are being implemented. Collaborations: Collaboration with government laboratories, universities, private organizations and regulatory agencies has leveraged the NREL Sensor Laboratory's success in advancing hydrogen safety sensors and process control. Proposed Future Work: NREL will support hydrogen deployment by the proper implementation of hydrogen sensors and advanced detection strategies. NREL will continue to support science-based codes and standards. This effort will be guided by the needs of the hydrogen community.
Thin Film Hydrogen Sensor Development, Testing and Integration Into Low Cost Wireless Sensing Systems (SBIR Phase 1 Final Report)
Element One, Inc. is reporting on the results of its DOE SBIR Phase I project for the development and testing of low-cost thin film hydrogen sensors and their subsequent integration into wireless sensing systems and networks. This work is based on Element One’s chemo-chromic sensing technology which indicates hydrogen presence (leaks) colorimetrically and electronically with no power required. The lack of required power makes them particularly suitable for passive Radio Frequency Identification Device (RFID) technology which can be deployed affordably and abundantly to detect leaks in hazardous environments. Element One built upon its experience with chemochromic materials that change color in the presence of hydrogen. Both thin films and pigments have been used, but thin films have the ability to change conductivity by more than three orders of magnitude making them ideal for resistive sensors. Prototype sensors were fabricated, tested and characterized. For the wireless component, Element One partnered with Esensor, Inc. to construct and test a wireless sensing network. The network was tested and validated at the National Renewable Energy Laboratory (NREL) in February and March. The tests involved exposing the wireless system to hydrogen gas concentrations of 1% and 5%. There were no significant problems encountered, and the system is ready for commercial development. The system demonstrated the viability of wireless hydrogen sensing networks for hydrogen leak detection and other applications.
A High-Temperature Multipoint Hydrogen Sensor Using an Intrinsic Fabry–Perot Interferometer in Optical Fiber
This paper presents a multiplexable fiber optic chemical sensor with the capability of monitoring hydrogen gas concentration at high temperatures up to 750 °C. The Pd-nanoparticle infused TiO 2 films coated on intrinsic Fabry–Perot interferometer (IFPI) array were used as sensory films. Strains induced upon exposure to hydrogen with varied concentrations can be monitored by IFPI sensors. The fiber sensor shows a repetitive and reversible response when exposed to a low level (1–6%) of hydrogen gas. Uniform sensory behavior across all the sensing cavities is demonstrated and reported in this paper.
A surface acoustic wave hydrogen sensor with tin doped indium oxide layers for intermediate temperatures
We report high temperature surface acoustic wave (SAW) gas sensors with conducting sensing layers require tuning of the sheet conductivity for optimal response. Conducting metal oxides are attractive sensing materials for their tunable electronic properties and high thermal stability, amongst others. Here, we have investigated the application of indium oxide (IO) and indium tin oxide (ITO) films on langasite (LGS)-based SAW reflective delay line sensor devices for monitoring hydrogen at 350 °C. Specifically, we modeled the effect of the IO and ITO sensing layer thickness on the wave velocity, attenuation, and effective electromechanical coefficient. This was followed by an experimental demonstration of tuning of the ITO film sheet conductivity by controlling the dopant concentration and yielding an improvement in the sensor sensitivity. The current study provides a pathway towards the development of conductivity-based sensing layers for high temperature SAW gas sensors with improved sensitivity.
Testing of In-Sodium Hydrogen Sensor
The goal of this project is to demonstrate diffusion-type in-sodium hydrogen meters (ISHMs) for real-time, in-situ monitoring of hydrogen concentration in molten sodium of a sodium-cooled fast reactor (SFR). The FY22 R&D efforts have been focused on (a) enhancement and fabrication of meshed ISHM prototype, (b) reconstruction of ISHM sodium test apparatus, (c) in-sodium test of meshed ISHM, and (d) ISHM performance and failure evaluations.
NREL Hydrogen Sensor Testing Laboratory
The NREL Sensor Laboratory supports the HFTO's mission for the safe and efficient implementation of hydrogen as an energy carrier. Sensors are a critical element for a facility safety system by providing an early indication of unintended releases. Sensors can be used in process control applications (e.g., FQ verification). The Sensor Laboratory provides developers and end-users with an unbiased resource to validate sensor performance to application requirements. The Sensor Laboratory facilitates deployment through support of codes and standards development and safety research. The Sensor Laboratory supports advanced strategies for early leak detection.
Sodium Hydrogen Sensor and Acoustic Flow Sensor Development
This report documents the development of diffusion-type hydrogen meters (DTHMs) as part of a steam generator leak detection system (SGLDS) of sodium-cooled fast reactors (SFR) and the demonstration of the capabilities of acoustic flowmeters, including a commercial UTFM (Flexim FLUXUS F721) and an Argonne HT acoustic flowmeter running on shear-to-longitudinal mode. It also evaluates two Argonne permanent magnet flowmeters (PMFMs).
Development of Risk Mitigation Guidance for Hydrogen Sensor Placement Indoors and Outdoors
Guidance on Sensor Placement remains one of the top priorities for the safe deployment of hydrogen and fuel cell equipment in the commercial marketplace. Building on the success of Phase 1 work reported at ICHS2019 and published in IJHE, this paper discusses the consecutive steps to further develop and validate such guidance for mechanically ventilated enclosures. The key step included a more in-depth analysis of sensitivity to variation of physical parameters in a small enclosure, and finally, expansion of the developed approach to confined spaces in an outdoor environment.
The NREL Sensor Laboratory: Hydrogen Leak Detection for Large Scale Deployments: Preprint
The NREL Hydrogen Sensor Laboratory was commissioned in 2010 as a resource for sensor developers, end-users, and regulatory agencies within the national and international hydrogen community. The Laboratory continues to provide as its core capability the unbiased verification of hydrogen sensor performance to assure sensor availability and their proper use. However, the mission and strategy of the NREL Sensor Laboratory has evolved to meet the needs of the growing hydrogen market. The Sensor Laboratory program has expanded to support research in conventional and alternative detection methods as hydrogen use expands to large-scale markets as envisioned by the DOE National Clean Hydrogen Strategy and Roadmap. Current research encompasses advanced methods of hydrogen leak detection including stand-off and wide area monitoring approaches for large scale and distributed applications. In addition to safety applications, low-level detection strategies to support the potential environmental impacts of hydrogen and hydrogen product losses along the value chain are being explored. Many of these applications utilize detection strategies that supplement and may supplant the use of traditional point sensors. The latest results of the hydrogen detection strategy research at NREL will be presented.
Ultra-fast and sensitive magneto-optical hydrogen sensors using a magnetic nano-cap array
Magnetism in curved nano-geometries has opened a new path to design novel characteristics and phenomena that could greatly impact the future fundamental and applied studies of materials. Here, in this report, a hexagonally-packed array of magnetic nano-caps (or nano-patches, NP) exhibiting unique magnetic anisotropy and optimal nanostructure for fast hydrogen kinetics is explored as a sensing element for the spark-free magnetic-circular-dichroism (MCD) H 2 sensor. The MCD H 2 sensor outperforms the state-of-the-art optical sensors reported to date and satisfies the most challenging performance targets imposed by US Department of Energy. In particular, a Pd 67 Co 33 NP sensor exhibits response time of t 90 < 0.9 s, recovery time of t 10 < 9.0 s over the 1-100 mbar H 2 partial pressure range, and limit of detection (LOD) of ~1 ppm. The LOD improves to <700 ppb, when the signal-to-noise ratio is enhanced by stacking three NP arrays. Using a 30-nm TAF (Teflon AF 2400) polymer coating, the sorption kinetics of the Pd 67 Co 33 /TAF sensor are significantly accelerated, with t 90 < 0.4 s and t 10 < 2.8 s over the same pressure range. When the Pd 67 Co 33 /TAF sensor is further coated with a 100-nm poly(methyl methacrylate) (PMMA) layer, a rapid sorption time of t 90 < 0.5 s, LOD < 1 ppm and excellent sensor accuracy (<2.5% full scale) are maintained, while the sensor obtains strong selectivity against interference gases and moisture and a negligible aging effect. The MCD nano-cap sensor platform may have a great impact on the future deployment of H 2 fuel, H 2 environmental monitoring sensors, and fast proton-based magneto-ionic devices.
High-Speed and Hysteresis-Free Near-Infrared Optical Hydrogen Sensor Based on Ti/Pd Bilayer Thin Films
Palladium (Pd) and titanium (Ti) exhibit opposite dielectric responses upon hydrogenation, with stronger effects observed in the near-infrared (NIR) region. Leveraging this contrast, we investigated Ti/Pd bilayer thin films as a platform for NIR hydrogen sensing—particularly at telecommunication-relevant wavelengths, where such devices have remained largely unexplored. Ti/Pd bilayers coated with Teflon AF (TAF) and fabricated via sequential electron-beam and thermal evaporation were characterized using optical transmission measurements under repeated hydrogenation cycles. The Ti (5 nm)/Pd (x = 2.5 nm)/TAF (30 nm) architecture showed a 2.7-fold enhancement in the hydrogen-induced optical contrast at 1550 nm compared to Pd/TAF reference films, attributed to the hydrogen ion exchange between the Ti and Pd layers. The optimized structure, with a Pd thickness of x = 1.9 nm, exhibited hysteresis-free sensing behavior, a rapid response time (t90 < 0.35 s at 4% H2), and a detection limit below 10 ppm. It also demonstrated excellent selectivity with negligible cross-sensitivity to CO2, CH4, and CO, as well as high durability, showing less than 6% signal degradation over 135 hydrogenation cycles. These findings establish a scalable, room-temperature NIR hydrogen sensing platform with strong potential for deployment in automotive, environmental, and industrial applications.
Review of noble metal and metal-oxide-semiconductor based chemiresistive hydrogen sensors
Not provided.
Rugged hydrogen sensor development for charge-exchange flux measurements on wall and divertor.
Abstract not provided.
Development of rugged hydrogen sensors for measuring charge-exchange neutral flux at the wall and divertor.
Abstract not provided.