At least 19 records

Comprehensive Evaluation of Electrochemical Hydrogen Separator as Hydrogen Recovery Solution for Plasma Pyrolysis Assembly

The previously tested State-of-the-Art (SOA) air revitalization architecture onboard the International Space Station recovers approximately 50% of the oxygen (O 2 ) from metabolic carbon dioxide (CO 2 ) via the Sabatier process. Maximum O 2 recovery is required to reduce resupply mass for long-duration manned missions. O 2 recovery is constrained by the limited availability of reactant hydrogen (H 2 ) from water (H 2 O) electrolysis, and Sabatier-produced methane (CH 4 ) is vented as a waste product resulting in a continuous loss of reactant H 2 . The Plasma Pyrolysis Assembly (PPA) has the potential to substantially increase O 2 recovery by post-processing the Sabatier-produced methane to recover H 2 . The PPA decomposes CH 4 into predominately H 2 and acetylene (C 2 H 2 ). A separation system is needed to purify the H 2 from the PPA stream before it is recycled back to the Sabatier reactor. Two sub-scale electrochemical H 2 separation systems, developed by Skyre, Incorporated, were delivered to NASA for evaluation. Complimentary of the previous submittal, ICES-2023-260, this paper reports a summation of Phase I and Phase II testing and evaluation of the C 2 H 2 removal systems as well as lessons learned.

Plasma Pyrolysis Assembly↗

Evaluation of Low-Energy Hydrogen Separation Method Using Metal-Organic Frameworks (MOFs) for Closed-Loop ECLSS Air Revitalization (CLEAR)

The State-of-the-Art (SOA) air revitalization architecture onboard the International Space Station (ISS) recovered approximately 50% of the oxygen (O 2 ) from metabolic carbon dioxide (CO 2 ) via the Sabatier process from 2011 to 2017. O 2 recovery is currently constrained by the limited availability of reactant hydrogen (H 2 ) preventing complete conversion of CO 2 to H 2 O. Increasing O 2 recovery within Closed-Loop ECLSS is essential to reducing resupply mass for long-duration manned missions; specifically focusing on water (H 2 O) which supplies H 2 for Sabatier via water electrolysis. Past ground test endeavors at Marshall Space Flight Center (MSFC) have attempted to recover H 2 from Sabatier-produced CH 4 using technologies such as carbon vapor deposition (CVD) and plasma pyrolysis. The byproducts of these technologies can act as a catalyst poison or reactor deadload to the Sabatier reactor. Hydrogen separation techniques must be utilized to maintain the Sabatier catalyst during gas recycling and must be scalable, non-energy intensive, and safe to operate in a habitation setting. Research indicated that metal-organic frameworks (MOFs) could meet these criteria and were tested for their capability to capture the various carbon-based gaseous products of CVD and plasma pyrolysis such as acetylene (C 2 H 2 ), ethylene (C 2 H 4 ), ethane (C 2 H 6 ), and carbon monoxide (CO) which would purify the hydrogen gas stream passing through the MOF. A sub-scale adsorption column was developed by Marshall Space Flight Center to test three MOF candidates against a synthetic gas mixture comprised of process-relevant carbonous gases and hydrogen to evaluate the separation capability of the MOFs. The results of the hydrogen separation capability, isothermal desorption capability, and demonstrated cyclic reuse of the MOF are presented in this paper.

Kagen Crawford↗

Device separates hydrogen from solution in water at ambient temperatures

Separator decreases the partial pressure of hydrogen gas dissolved in the water produced by fuel cells containing an alkaline electrolyte. The unit eliminates the hazards associated with the release of hydrogen from water solution when the hydrostatic pressure is rapidly decreased.

Albright, C. F.↗

Nickel-hydrogen separator development

The separator technology is a critical element in the nickel-hydrogen (Ni-H2) systems. Previous research and development work carried out at NASA Lewis Research Center has determined that separators made from zirconium oxide (ZrO2) and potassium titanate (PKT) fibers will function satisfactorily in Ni-H2 cells without exhibiting the problems associated with the asbestos separators. These separators and their characteristics were previously discussed. A program was established to transfer the separator technology into a commercial production line. A detailed plan of this program will be presented and the preliminary results will be discussed.

Gonzalez-Sanabria, O. D.↗

Nickel-hydrogen separator development

The separator technology is a critical element in the nickel-hydrogen (Ni-H2) systems. Previous research and development work carried out at NASA Lewis Research Center has determined that separators made from zirconium oxide (ZrO2) and potassium titanate (PKT) fibers will function satisfactorily in Ni-H2 cells without exhibiting the problems associated with the asbestos separators. A program has been established to transfer the separator technology into a commercial production line. A detailed plan of this program will be presented and the preliminary results will be discussed.

Gonzalez-Sanabria, O. D.↗

Methane Post-Processing and Hydrogen Separation for Spacecraft Oxygen Loop Closure

State-of-the-art life support oxygen recovery technology on the International Space Station is based on the Sabatier reaction where only about half of the oxygen required for the crew is recovered from metabolic carbon dioxide (CO2). The Sabatier reaction produces water as the primary product and methane as a byproduct. Oxygen recovery is constrained by both the limited availability of reactant hydrogen from water electrolysis and Sabatier methane (CH4) being vented as a waste product resulting in a continuous loss of reactant hydrogen. Post-processing methane with the Plasma Pyrolysis Assembly (PPA) to recover this hydrogen has the potential to substantially increase oxygen recovery and thus dramatically reduce the logistical challenges associated with oxygen resupply. The PPA decomposes methane into predominantly hydrogen and acetylene. A purification system is necessary to purify hydrogen before it is recycled back to the Sabatier reactor. Testing and evaluation of acetylene removal systems and PPA system architectures are presented and discussed.

Greenwood, Zachary W.↗

High-Temperature Proton-Conducting Ceramics Developed

High-temperature protonic conductors (HTPC) are needed for hydrogen separation, hydrogen sensors, fuel cells, and hydrogen production from fossil fuels. The HTPC materials for hydrogen separation at high temperatures are foreseen to be metal oxides with the perovskite structure A(sup 2+)B(sup 4+)C(sup 2-, sub 3) and with the trivalent cation (M(sup 3+)) substitution at the B(sup 4+)-site to introduce oxygen vacancies. The high affinity for hydrogen ions (H(sup +)) is advantageous for protonic transport, but it increases the reactivity toward water (H2O) and carbon dioxide (CO2), which can lead to premature membrane failure. In addition, there are considerable technological challenges related to the processing of HTPC materials. The high melting point and multi-cation chemistry of HTPC materials creates difficulties in in achieving high-density, single-phase membranes by solid-state sintering. The presence of secondary phases and grain-boundary interfaces are detrimental to the protonic conduction and environmental stability of polycrystalline HTPC materials.

Sayir, Ali↗

Development of a nitrogen generation system

An eight-stage nitrogen generation module was developed. The design integrated a hydrazine catalytic dissociator, three ammonia dissociation stages and four palladium/silver hydrogen separator stages. Alternating ammonia dissociation and hydrogen separation stages are used to remove hydrogen and ammonia formed in the dissociation of hydrazine which results in negligible ammonia and hydrogen concentrations in the product nitrogen stream. An engineering breadboard nitrogen supply subsystem was also developed. It was developed as an integratable subsystem for a central spacecraft air revitalization system. The subsystem consists of the hydrazine storage and feed mechanism, the nitrogen generation module, the peripheral mechanical and electrical components required to control and monitor subsystem performance, and the instrumentation required to interface with other subsystems of an air revitalization system. The breadboard nitrogen supply subsystem was integrated and tested with a one-person capacity experimental air revitalization system. The integration, checkout and testing was successfully accomplished.

Heppner, D. B.↗

Thermal Analysis of Cryogenic Hydrogen Liquid Separator

During launch for the new Space Launch System (SLS) liquid hydrogen is bleed through the engines during replenish, pre-press, and extended pre-press to condition the engines prior to launch. The predicted bleed flow rates are larger than for the shuttle program. A consequence of the increased flow rates is having liquif hydrogen in the vent system, which the facilities was never designed to handle. To remedy the problem a liquid separator is being designed in the system to accumulated the liquid propellant and protect the facility flare stack (which can only handle gas). The attached document is a presentation of the current thermalfluid analysis performed for the separator and will be presented at the Thermal and Fluid Analysis Workshop (NASA workshop) next week in Cleveland, Ohio.

liquid separator↗

Evaluation of Electrochemical Nitrogen/hydrogen Gas Separator

An electrochemical nitrogen-hydrogen separator subsystem was investigated for use following catalytic dissociation of ammonia or hydrazine in a storage system being considered for long-duration manned space flight. An experimental cell with concentric tubular Pd-25Ag alloy hydrogen diffusion electrodes and hermetically sealed aqueous caustic electrolyte was developed.It was found that this cell operated satisfactorily at 210 C to 245 C and produced dry nitrogen and dry hydrogen with either or both gases at pressures up to 6.8 atmospheres (100 psia) or higher for storage. The final cell developed was operated satisfactorily for 176 days (4200 hours) with no evidence of deterioration of current-voltage performance. The best experimental performance was obtained at 245 C at currents up to 4 amperes (180 ma/sq cm and 360 ma/sq cm anode and cathode current densities, respectively) with a maximum steady-state cell voltage of 0.125 volt for an anode feed of pure hydrogen.

Clifford, J. E.↗

GC/MS Gas Separator Operates At Lower Temperatures

Experiments show palladium/silver tube used to separate hydrogen carrier gas from gases being analyzed in gas-chromatography/mass-spectrometry (GC/MS) system functions satisfactorily at temperatures as low as 70 to 100 degrees C. Less power consumed, and catalytic hydrogenation of compounds being analyzed diminished. Because separation efficiency high even at lower temperatures, gas load on vacuum pump of mass spectrometer kept low, permitting use of smaller pump. These features facilitate development of relatively small, lightweight, portable GC/MS system for such uses as measuring concentrations of pollutants in field.

Sinha, Mahadeva P.↗

Hydrogen Masers as Time and Frequency Standards

Track each other with 100 times more precision than cesium standards. Geographically separated hydrogen masers tracked each other for more than year to within few parts in 10 to the 15th power. Frequency offset of hydrogen-maser output from hyperfine line frequency is function of ambient magnetic field, cavity mistuning, thermal motion of atoms in cavity and collisions of atoms with walls of the cavity. If maser remains at one location some of small offsets in frequency will remain constant throughout life of maser.