Comparing Cetane Number Measurement Methods

Cetane number is one of the most important fuel performance metrics for mixing controlled compression-ignition “diesel” engines, quantifying a fuel’s propensity for autoignition when injected into end-of-compression-type temperature and pressure conditions. The historical default and referee method on a Cooperative Fuel Research (CFR) engine configured with indirect fuel injection and variable compression ratio is cetane number (CN) rating. A subject fuel is evaluated against primary reference fuel blends, with heptamethylnonane defining a low-reactivity endpoint of CN = 15 and hexadecane defining a high-reactivity endpoint of CN = 100. While the CN scale covers the range from zero (0) to 100, typical testing is in the range of 30 to 65 CN. Alternatively, several constant-volume combustion chamber (CVCC)-based cetane rating devices have been developed to rate fuels with an equivalent derived cetane number (DCN) or indicated cetane number (ICN). These devices measure ignition delay for fuel injected into a fixed volume of high-temperature and high-pressure air to simulate end-of-compression-type conditions. In this study, a range of novel fuel compounds are evaluated across three CVCC methods: the Ignition Quality Tester (IQT), Fuel Ignition Tester (FIT), and Advanced Fuel Ignition Delay Analyzer (AFIDA). Resulting DCNs and ICNs are compared for fuels within the normal diesel fuel range of reactivity, as well as very high (~100) and very low DCNs/ICNs (~5). Distinct differences between results from various devices are discussed. This is important to consider because some new, high-efficiency advanced compression-ignition (CI) engine combustion strategies operate with more kinetically controlled distributed combustion as opposed to mixing controlled diffusion flames. These advanced combustion strategies may benefit from new fuel chemistries, but current rating methods of CN, DCN, and ICN may not fully describe their performance. In addition, recent evidence suggests ignition delay in modern on-road diesel engines with high-pressure common rail fuel injection systems may no longer directly correlate to traditional CN fuel ratings. Simulated end-of-compression conditions are compared for CN, DCN, and ICN and discussed in the context of modern diesel engines to provide additional insight. Results highlight the potential need for revised and/or multiple fuel test conditions to measure fuel performance for advanced CI strategies.

47 OTHER INSTRUMENTATION↗

Kinetic model-based group contribution method for derived cetane number prediction of oxygenated fuel components and blends

A four-step autoignition model was used to derive an expression for the ignition delay (ID) measured in ignition quality testers (IQT) with the derived cetane number (DCN) determined from this ID using the ASTM D6890 standard correlation. The model predicts DCN for individual compounds and blends as a function of each compound's global initiation and net chain branching rate constants. Expressions for these values were determined assuming they could be related to the functional groups present in each compound. Measurement data for 125 compounds and 94 binary and ternary blends (including oxygenates: alcohols, aldehydes, esters, ethers, and ketones), from literature and from measurements performed in our lab, were used to obtain the dependence of the measured ignition delay on each functional group. The new kinetic model-based group contribution method was able to predict the ignition delay of both pure compounds and blends, with an average DCN error of 4.4 (19%) and 2.8 (11%), respectively. Here, the blend model was also used to develop an ID mixing rule by incorporating existing IQT ignition delay data for each compound. Use of the mixing rule gave an average DCN error of 3.6 (16%) for blends. Both the blend model and mixing rule were found to be superior compared to standard linear by volume fraction or mole fraction mixing rules commonly used to estimate the DCN of mixtures.

42 ENGINEERING↗

Simple Autoignition Model for the Derived Cetane Number of Oxygenated Compounds and Fuel Blends

A four-step autoignition model was used to derive an expression for the ignition delay and derived cetane number (DCN) measured by ignition quality testers (IQT) for oxygenated compounds and blends as a function of each compound’s global initiation and net chain branching rate constants. Expressions for these values were determined assuming they could be related to the functional groups present in a compound. Measurements for 124 compounds and 94 binary and ternary blends, gathered from the literature and performed at UW-Madison, were used to obtain the dependence of the measured ignition delay on each functional group. The new model was able to describe the ignition behavior of both the compounds and blends, with an average DCN error of 5.0 (22%) and 3.5 (15%), respectively. Additionally, the blend model was transformed into a mixing rule by incorporating existing IQT ignition delay data for each compound. Use of the mixing rule was found to offer improvements over the full prediction, with an average DCN error of 3.2 (14%).

Witkowski, Dustin↗

Simple Autoignition Model for the Derived Cetane Number of Oxygenated Compounds and Fuel Blends

A simple four-step autoignition model was used to derive an expression for the ignition delay and derived cetane number (DCN) measured by ignition quality testers (IQT) for oxygenated compounds and blends as a function of each compound’s global initiation and net chain branching rate constants. Expressions for these values were determined assuming they could be related to the functional groups present in a given compound. Measurements for 124 compounds and 94 binary and ternary blends, gathered from the literature and performed at UW-Madison, were used to obtain the explicit dependence of the measured ignition delay on each functional group. The new model was able to successfully describe the ignition behavior of both the compounds and blends, with an average DCN error of 5.0 (22%) and 3.5 (15%), respectively. Additionally, the blend model could naturally be modified into a mixing rule by incorporating existing IQT ignition delay data for each compound. Use of the mixing rule was found to offer improvements over the full prediction, with an average DCN error of 3.2 (14%).

09 BIOMASS FUELS↗

Oxidation and pyrolysis of methyl propyl ether

The ignition, oxidation, and pyrolysis chemistry of methyl propyl ether (MPE) was probed experimentally at several different conditions, and a comprehensive chemical kinetic model was constructed to help understand the observations, with many of the key parameters computed using quantum chemistry and transition state theory. Experiments were carried out in a shock tube measuring time variation of CO concentrations, in a flow tube measuring product concentrations, and in a rapid compression machine (RCM) measuring ignition delay times. The detailed reaction mechanism was constructed using the Reaction Mechanism Generator software. Sensitivity and flux analyses were used to identify key rate and thermochemical parameters, which were then computed using quantum chemistry to improve the mechanism. Validation of the final model against the 1-20 bar 600-1500 K experimental data is presented with a discussion of the kinetics. The model is in excellent agreement with most of the shock tube and RCM data. Strong non-monotonic variation in conversion and product distribution is observed in the flow-tube experiments as the temperature is increased, and unusually strong pressure dependence and significant heat release during the compression stroke is observed in the RCM experiments. These observations are largely explained by a close competition between radical decomposition and addition to O2 at different sites in MPE; this causes small shifts in conditions to lead to big shifts in the dominant reaction pathways. The validated mechanism was used to study the chemistry occurring during ignition in a diesel engine, simulated using Ignition Quality Test (IQT) conditions. At the IQT conditions, where the MPE concentration is higher, bimolecular reactions of peroxy radicals are much more important than in the RCM.