Fusion Imaging to Guide Thoracic Endovascular Aortic Repair (TEVAR): A Randomized Comparison of Two Methods, 2D/3D Versus 3D/3D Image Fusion

Purpose: To compare the accuracy of two-dimensional (2D) versus three-dimensional (3D) image fusion for thoracic endovascular aortic repair (TEVAR) image guidance. Materials and Methods: Between December 2016 and March 2018, all eligible patients who underwent TEVAR were prospectively included in a single-center study. Image fusion methods (2D/3D or 3D/3D) were randomly assigned to guide each TEVAR and compared in terms of accuracy, dose area product (DAP), volume of contrast medium injected, fluoroscopy time and procedure time. Results: Thirty-two patients were prospectively included; 18 underwent 2D/3D and 14 underwent 3D/3D TEVAR. The 3D/3D method allowed more accurate positioning of the aortic mask on top of the fluoroscopic images (proximal landing zone error vector: 1.7 ± 3.3 mm) than was achieved by the 2D/3D method (6.1 ± 6.1 mm; p = 0.03). The 3D/3D image fusion method was associated with significantly lower DAP than the 2D/3D method (50.5 ± 30.1 Gy cm{sup 2} for 3D/3D vs. 99.5 ± 79.1 Gy cm{sup 2} for 2D/3D; p = 0.03). The volume of contrast medium injected was significantly lower for the 3D/3D method than for the 2D/3D method (50.6 ± 22.9 ml vs. 98.4 ± 47.9 ml; p = 0.002). Conclusion: Higher image fusion accuracy and lower contrast volume and irradiation dose were observed for 3D/3D image fusion than for 2D/3D during TEVAR. Level of Evidence: II, Randomized trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of volume measurement using 3D ultrasound and development of CT-3D US image fusion algorithm for prostate cancer radiotherapy

Purpose: To evaluate the accuracy of measuring volumes using three-dimensional ultrasound (3D US), and to verify the feasibility of the replacement of CT-MR fusion images with CT-3D US in radiotherapy treatment planning. Methods: Phantoms, consisting of water, contrast agent, and agarose, were manufactured. The volume was measured using 3D US, CT, and MR devices. A CT-3D US and MR-3D US image fusion software was developed using the Insight Toolkit library in order to acquire three-dimensional fusion images. The quality of the image fusion was evaluated using metric value and fusion images. Results: Volume measurement, using 3D US, shows a 2.8 {+-} 1.5% error, 4.4 {+-} 3.0% error for CT, and 3.1 {+-} 2.0% error for MR. The results imply that volume measurement using the 3D US devices has a similar accuracy level to that of CT and MR. Three-dimensional image fusion of CT-3D US and MR-3D US was successfully performed using phantom images. Moreover, MR-3D US image fusion was performed using human bladder images. Conclusions: 3D US could be used in the volume measurement of human bladders and prostates. CT-3D US image fusion could be used in monitoring the target position in each fraction of external beam radiation therapy. Moreover, the feasibility of replacing the CT-MR image fusion to the CT-3D US in radiotherapy treatment planning was verified.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Lung Tumor Biopsy Under CBCT Guidance with PET-CT Fusion Imaging: Preliminary Experience

Purpose: The aim of this study is to evaluate the feasibility of percutaneous lung tumor biopsy under cone beam-computed tomography (CBCT) with PET-CT imaging fusion. Materials and Methods: Eleven patients (four women and seven men) underwent C-arm CBCT lung biopsy with PET-CT fusion imaging. A preprocedural PET-CT scan was manually fused with procedural CBCT based on anatomical landmarks; using real-time fluoroscopy, the coregistered PET-CT and CBCT images were overlaid to guide the needle trajectory. Technical success, accuracy, sensibility and specificity were evaluated. Mean total procedure time and time required for image elaboration were recorded. Results: Technical success, diagnostic accuracy, sensitivity and specificity were 100%. The mean procedure time was 38 min. The average time of PET-CT/CBCT image fusion elaboration was 3.53 min for planning and 3.42 min for needle positioning check. Conclusion: CBCT-guided percutaneous lung biopsy with PET-CT fusion imaging is a feasible and effective procedure, with the potential to further improve diagnostic yield by targeting the most metabolically active portion of a lesion, whether it is morphologically altered or normal.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multimodality Image Fusion and Planning and Dose Delivery for Radiation Therapy

Image-guided radiation therapy (IGRT) relies on the quality of fused images to yield accurate and reproducible patient setup prior to dose delivery. The registration of 2 image datasets can be characterized as hardware-based or software-based image fusion. Hardware-based image fusion is performed by hybrid scanners that combine 2 distinct medical imaging modalities such as positron emission tomography (PET) and computed tomography (CT) into a single device. In hybrid scanners, the patient maintains the same position during both studies making the fusion of image data sets simple. However, it cannot perform temporal image registration where image datasets are acquired at different times. On the other hand, software-based image fusion technique can merge image datasets taken at different times or with different medical imaging modalities. Software-based image fusion can be performed either manually, using landmarks, or automatically. In the automatic image fusion method, the best fit is evaluated using mutual information coefficient. Manual image fusion is typically performed at dose planning and for patient setup prior to dose delivery for IGRT. The fusion of orthogonal live radiographic images taken prior to dose delivery to digitally reconstructed radiographs will be presented. Although manual image fusion has been routinely used, the use of fiducial markers has shortened the fusion time. Automated image fusion should be possible for IGRT because the image datasets are derived basically from the same imaging modality, resulting in further shortening the fusion time. The advantages and limitations of both hardware-based and software-based image fusion methodologies are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image fusion for neutron tomography of nuclear fuel

Image fusion, the process of combining different images together, can be useful to create a more complete picture. In this work, image fusion is applied to neutron tomography of nuclear fuel with the goal of enhancing the information obtained about the fuel. Different reconstruction methods, such as Feldkamp, Davis and Kress filtered back projection and Simultaneous Reconstruction Technique, were combined to enhance image quality. This methodology was shown to reduce noise and ring artifacts without sacrificing sharp edges, allowing for a more accurate representation of sample geometry. Technique enhancements and future applications for the neutron imaging community are also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Percutaneous Thermal Ablation with Ultrasound Guidance. Fusion Imaging Guidance to Improve Conspicuity of Liver Metastasis

PurposeTo assess whether fusion imaging-guided percutaneous microwave ablation (MWA) can improve visibility and targeting of liver metastasis that were deemed inconspicuous on ultrasound (US).Materials and MethodsMWA of liver metastasis not judged conspicuous enough on US was performed under CT/US fusion imaging guidance. The conspicuity before and after the fusion imaging was graded on a five-point scale, and significance was assessed by Wilcoxon test. Technical success, procedure time, and procedure-related complications were evaluated.ResultsA total of 35 patients with 40 liver metastases (mean size 1.3 ± 0.4 cm) were enrolled. Image fusion improved conspicuity sufficiently to allow fusion-targeted MWA in 33 patients. The time required for image fusion processing and tumors’ identification averaged 10 ± 2.1 min (range 5–14). Initial conspicuity on US by inclusion criteria was 1.2 ± 0.4 (range 0–2), while conspicuity after localization on fusion imaging was 3.5 ± 1 (range 1–5, p < 0.001). Technical success rate was 83% (33/40) in intention-to-treat analysis and 100% in analysis of treated tumors. There were no major procedure-related complications.ConclusionsFusion imaging broadens the scope of US-guided MWA to metastasis lacking adequate conspicuity on conventional US. Fusion imaging is an effective tool to increase the conspicuity of liver metastases that were initially deemed non visualizable on conventional US imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional Image Fusion Guidance for Transjugular Intrahepatic Portosystemic Shunt Placement

IntroductionTo assess the safety, feasibility and effectiveness of image fusion guidance with pre-procedural portal phase computed tomography with intraprocedural fluoroscopy for transjugular intrahepatic portosystemic shunt (TIPS) placement.Materials and methodsAll consecutive cirrhotic patients presenting at our interventional unit for TIPS creation from January 2015 to January 2016 were prospectively enrolled. Procedures were performed under general anesthesia in an interventional suite equipped with flat panel detector, cone-beam computed tomography (CBCT) and image fusion technique. All TIPSs were placed under image fusion guidance. After hepatic vein catheterization, an unenhanced CBCT acquisition was performed and co-registered with the pre-procedural portal phase CT images. A virtual path between hepatic vein and portal branch was made using the virtual needle path trajectory software. Subsequently, the 3D virtual path was overlaid on 2D fluoroscopy for guidance during portal branch cannulation. Safety, feasibility, effectiveness and per-procedural data were evaluated.ResultsSixteen patients (12 males; median age 56 years) were included. Procedures were technically feasible in 15 of the 16 patients (94%). One procedure was aborted due to hepatic vein catheterization failure related to severe liver distortion. No periprocedural complications occurred within 48 h of the procedure. The median dose-area product was 91 Gy cm{sup 2}, fluoroscopy time 15 min, procedure time 40 min and contrast media consumption 65 mL. Clinical benefit of the TIPS placement was observed in nine patients (56%).ConclusionThis study suggests that 3D image fusion guidance for TIPS is feasible, safe and effective. By identifying virtual needle path, CBCT enables real-time multiplanar guidance and may facilitate TIPS placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fusion Imaging Reduces Radiation and Contrast Medium Exposure During Endovascular Revascularization of Iliac Steno-Occlusive Disease

Introduction: To evaluate feasibility, safety and efficacy of fusion imaging in order to guide endovascular revascularization of iliac steno-occlusive disease. Materials and Methods: Retrospectively, we identified twenty-six patients (20 male, mean age 63 ± 8y; Rutherford II-V) who underwent revascularization of a chronic total occlusion (n = 6; 23%) or severe stenosis (n = 20; 77%) of the common and/or external iliac artery. Median lesion length was 33 mm (IQR 20–60). In one group of patients (NEW; n = 11), fusion imaging with 2-D/3-D registration was used to guide revascularization. No baseline digital subtraction angiography (DSA) had been acquired in these patients. In another group of patients (OLD; n = 15), no fusion imaging had been utilized and at least one DSA run had been performed to guide the procedure. In both groups, final DSA of the treated lesions was performed. Number of DSA runs, radiation and contrast medium exposure, technical success (residual stenosis < 30%) and complications were analyzed. Results: Median DSA runs needed in OLD for guidance were n = 2 (IQR 2–3) and in NEW n = 0 (IQR 0–0; p = 0.001). Compared to OLD, median dose area product (DAP) was reduced by 17,118 mGy*cm{sup 2} (IQR 10,407–23,614; p = 0.016) if fusion imaging guidance had been used (NEW). Based on the median DAP of the final angiogram in NEW, median DAP reduction was 6007 mGy*cm{sup 2} (IQR 5012–16,105; p = 0.1). Median total contrast medium volume injected in NEW was 45 ml (IQR 30–90) and in OLD 120 ml (IQR 100–140; p = 0.001). Technical success was 100% for both groups. In 1/27 patients (3.7%) a minor complication (embolism) occurred. Conclusion: Fusion imaging proved to be feasible as well as safe and significantly reduces radiation and contrast medium exposure during endovascular revascularization of iliac steno-occlusive disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Fusion Guidance for In Situ Laser Fenestration of Aortic Stent graft for Endovascular Repair of Complex Aortic Aneurysm: Feasibility, Efficacy and Overall Functional Success

Objective: To evaluate feasibility, efficacy and overall functional success of image fusion guidance during laser-assisted in situ fenestration of aortic stent graft (LISFAS) for endovascular repair of complex aortic aneurysm (complex-EVAR) in a prospective study. Methods: Between September 2016 and July 2018, 20 patients were included and treated with LISFAS for complex-EVAR. Aortic aneurysms were either para-renal (n = 15) or thoraco-abdominal (n = 5) with 57 mm [first quartile: 54; third quartile: 68] median aneurysm diameter in 69 years [68;78] patients. All interventions were performed using the same angiographic system and 3D image fusion software for overlying pre-intervention CTA on per-intervention 2D fluoroscopy with cone-beam CT images to display target vessels ostia. Results: LISFAS for complex-EVAR with image fusion was performed in all patients, and no endovascular intervention required conversion to an open aortic repair. LISFAS of all target vessels was feasible in 18 patients (90%); 48 fenestrations out of 50 were performed successfully. Two fenestrations failed for renal arteries in two patients. Median ischemic times were as follows: 34 min [25;43] for superior mesenteric artery; 69 min [56;83] for left renal artery; 73 min [36;102] for right renal artery; and 93 min [89;96] for the celiac trunk. Median intervention and fluoroscopy times, iodinated contrast volume and X-ray exposure were 180 min [150;180], 74 min [64;87], 80 mL [59;113] and 338 Gy.cm{sup 2} [259;495], respectively. Efficacy was found in 17 patients (85%) on one-week follow-up CTA: Two patients had type 1 and 3 endoleaks, respectively, that were successfully embolized. Overall functional success was 90%. Median hospitalization stay was 9 days [8, 17]. The 30-day safety analysis was 90% (n = 2 deaths) owing to an undetermined cause and to bowel ischemia after low flow in intensive care unit. Conclusions: LISFAS using image fusion was feasible, efficient and overall functionally successful for complex-EVAR in this preliminary study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Evaluation of Spatial Accuracy of a Fusion Imaging Technique Combining Previously Acquired Computed Tomography and Real-Time Ultrasound for Imaging of Liver Metastases

Purpose: This study was designed to evaluate the spatial accuracy of matching volumetric computed tomography (CT) data of hepatic metastases with real-time ultrasound (US) using a fusion imaging system (VNav) according to different clinical settings. Methods: Twenty-four patients with one hepatic tumor identified on enhanced CT and US were prospectively enrolled. A set of three landmarks markers was chosen on CT and US for image registration. US and CT images were then superimposed using the fusion imaging display mode. The difference in spatial location between the tumor visible on the CT and the US on the overlay images (reviewer no. 1, comment no. 2) was measured in the lateral, anterior-posterior, and vertical axis. The maximum difference (Dmax) was evaluated for different predictive factors.CT performed 1-30 days before registration versus immediately before. Use of general anesthesia for CT and US versus no anesthesia.Anatomic landmarks versus landmarks that include at least one nonanatomic structure, such as a cyst or a calcificationResultsOverall, Dmax was 11.53 {+-} 8.38 mm. Dmax was 6.55 {+-} 7.31 mm with CT performed immediately before VNav versus 17.4 {+-} 5.18 with CT performed 1-30 days before (p < 0.0001). Dmax was 7.05 {+-} 6.95 under general anesthesia and 16.81 {+-} 6.77 without anesthesia (p < 0.0015). Landmarks including at least one nonanatomic structure increase Dmax of 5.2 mm (p < 0.0001). The lowest Dmax (1.9 {+-} 1.4 mm) was obtained when CT and VNav were performed under general anesthesia, one immediately after the other. Conclusions: VNav is accurate when adequate clinical setup is carefully selected. Only under these conditions (reviewer no. 2), liver tumors not identified on US can be accurately targeted for biopsy or radiofrequency ablation using fusion imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of early stage atherosclerotic plaques using PET and CT fusion imaging targeting P-selectin in low density lipoprotein receptor-deficient mice

Highlights: ► P-selectin regulates leukocyte recruitment as an early stage event of atherogenesis. ► We developed an antibody-based molecular imaging probe targeting P-selectin for PET. ► This is the first report on successful PET imaging for delineation of P-selectin. ► P-selectin is a candidate target for atherosclerotic plaque imaging by clinical PET. -- Abstract: Background: Sensitive detection and qualitative analysis of atherosclerotic plaques are in high demand in cardiovascular clinical settings. The leukocyte–endothelial interaction mediated by an adhesion molecule P-selectin participates in arterial wall inflammation and atherosclerosis. Methods and results: A {sup 64}Cu-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid conjugated anti-P-selectin monoclonal antibody ({sup 64}Cu-DOTA-anti-P-selectin mAb) probe was prepared by conjugating an anti-P-selectin monoclonal antibody with DOTA followed by {sup 64}Cu labeling. Thirty-six hours prior to PET and CT fusion imaging, 3 MBq of {sup 64}Cu-DOTA-anti-P-selectin mAb was intravenously injected into low density lipoprotein receptor-deficient Ldlr-/- mice. After a 180 min PET scan, autoradiography and biodistribution of {sup 64}Cu-DOTA-anti-P-selectin monoclonal antibody was examined using excised aortas. In Ldlr-/- mice fed with a high cholesterol diet for promotion of atherosclerotic plaque development, PET and CT fusion imaging revealed selective and prominent accumulation of the probe in the aortic root. Autoradiography of aortas that demonstrated probe uptake into atherosclerotic plaques was confirmed by Oil red O staining for lipid droplets. In Ldlr-/- mice fed with a chow diet to develop mild atherosclerotic plaques, probe accumulation was barely detectable in the aortic root on PET and CT fusion imaging. Probe biodistribution in aortas was 6.6-fold higher in Ldlr-/- mice fed with a high cholesterol diet than in those fed with a normal chow diet. {sup 64}Cu-DOTA-anti-P-selectin mAb accumulated selectively in aortic atherosclerotic plaques and was detectable by PET and CT fusion imaging in Ldlr-/- mice. Conclusions: P-selectin is a candidate target molecule for early-phase detection by PET and CT fusion imaging of atherosclerotic plaques.

60 APPLIED LIFE SCIENCES↗

Multispectral medical image fusion in Contourlet domain for computer based diagnosis of Alzheimer’s disease

Computer based diagnosis of Alzheimer’s disease can be performed by dint of the analysis of the functional and structural changes in the brain. Multispectral image fusion deliberates upon fusion of the complementary information while discarding the surplus information to achieve a solitary image which encloses both spatial and spectral details. This paper presents a Non-Sub-sampled Contourlet Transform (NSCT) based multispectral image fusion model for computer-aided diagnosis of Alzheimer’s disease. The proposed fusion methodology involves color transformation of the input multispectral image. The multispectral image in YIQ color space is decomposed using NSCT followed by dimensionality reduction using modified Principal Component Analysis algorithm on the low frequency coefficients. Further, the high frequency coefficients are enhanced using non-linear enhancement function. Two different fusion rules are then applied to the low-pass and high-pass sub-bands: Phase congruency is applied to low frequency coefficients and a combination of directive contrast and normalized Shannon entropy is applied to high frequency coefficients. The superiority of the fusion response is depicted by the comparisons made with the other state-of-the-art fusion approaches (in terms of various fusion metrics).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-Time US-{sup 18}FDG-PET/CT Image Fusion for Guidance of Thermal Ablation of {sup 18}FDG-PET-Positive Liver Metastases: The Added Value of Contrast Enhancement

Purpose: To assess the feasibility of US-{sup 18}FDG-PET/CT fusion-guided microwave ablation of liver metastases either poorly visible or totally undetectable with US, CEUS and CT, but visualized by PET imaging. Materials and Methods: Twenty-three patients with 58 liver metastases underwent microwave ablation guided by image fusion system that combines US with {sup 18}FDG-PET/CT images. In 28/58 tumors, {sup 18}FDG-PET/CT with contrast medium (PET/CECT) was used. The registration technical feasibility, registration time, rates of correct targeting, technical success at 24 h, final result at 1 year and complications were analyzed and compared between the PET/CT and PET/CECT groups. Results: Registration was successfully performed in all cases with a mean time of 7.8 + 1.7 min (mean + standard deviation), (4.6 + 1.5 min for PET/CECT group versus 10.9 + 1.8 min for PET/CT group, P < 0.01). In total, 46/58 (79.3%) tumors were correctly targeted, while 3/28 (10.7%) and 9/30 (30%) were incorrectly targeted in PET/CT and PET/CECT group, respectively (P < 0.05). Complete ablation was obtained at 24 h in 70.0% of cases (n = 40 tumors), 23/28 (82.1%) in the PET/CECT group and 17/30 (56.7%) in the PET/CT group (P < 0.037). Fourteen tumors underwent local retreatment (11 ablations, 2 with resection and 1 with stereotactic body radiation therapy), while 4 tumors could not be retreated because of distant disease progression and underwent systemic therapy. Finally, 54/58 (93.1%) tumors were completely treated at 1 year. One major complication occurred, a gastrointestinal hemorrhage which required surgical repair. Conclusions: Percutaneous ablation of {sup 18}FDG-PET-positive liver metastases using fusion imaging of real-time US and pre-acquired {sup 18}FDG-PET/CT images is feasible, safe and effective. Contrast-enhanced PET/CT improves overall ablation accuracy and shortens procedural duration time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time US-CT/MRI Image Fusion for Guidance of Thermal Ablation of Liver Tumors Undetectable with US: Results in 295 Cases

PurposeThis study was designed to assess feasibility of US-CT/MRI fusion-guided ablation in liver tumors undetectable with US.MethodsFrom 2002 to 2012, 295 tumors (162 HCCs and 133 metastases; mean diameter 1.3 ± 0.6 cm, range 0.5–2.5 cm) detectable on contrast-enhanced CT/MRI, but completely undetectable with unenhanced US and either totally undetectable or incompletely conspicuous with contrast-enhanced US (CEUS), were treated in 215 sessions using either internally cooled radiofrequency or microwave with standard ablation protocols, guided by an image fusion system (Virtual Navigation System, Esaote S.p.A., Genova, Italy) that combines US with CT/ MRI images. Correct targeting and successful ablation of tumor were verified after 24 hours with CT or MRI.ResultsA total of 282 of 295 (95.6 %) tumors were correctly targeted with successful ablation achieved in 266 of 295 (90.2 %). Sixteen of 295 (5.4 %) tumors were correctly targeted, but unsuccessfully ablated, and 13 of 295 (4.4 %) tumors were unsuccessfully ablated due to inaccurate targeting. There were no perioperative deaths. Major complications were observed in 2 of the 215 treatments sessions (0.9 %).ConclusionsReal-time virtual navigation system with US-CT/MRI fusion imaging is precise for targeting and achieving successful ablation of target tumors undetectable with US alone. Therefore, a larger population could benefit from ultrasound guided ablation procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Fusion Guidance with Pre-procedural CT with Real-Time Fluoroscopy for Adrenal Venous Sampling

PurposeTo assess the effectiveness of image fusion guidance (IF) with pre-procedural computed tomography (CT) with intraprocedural fluoroscopy for adrenal venous sampling (AVS).Materials and MethodsAVS before and after ACTH stimulation including bilateral segmental sampling of effluent tributaries was performed in 62 patients with IF. A 3D volume rendering image, including adrenal glands and veins extracted from previously obtained contrast-enhanced CT images, was manually registered to the real-time X-ray fluoroscopy. The technical success rates, procedure time, radiation exposure, and volume of contrast medium used were compared with 49 patients who underwent AVS without IF.ResultsNo significant differences in the technical success rates with and without IF were observed (98.4 vs. 91.8% for the right adrenal veins, p = 0.168, and 98.4 vs. 100% for the left adrenal veins, p = 1.000). The procedure time with IF was significantly shorter than that without IF (95.6 ± 18.8 vs. 108.4 ± 20.0 min, p = 0.001). The total dose-area product with IF was significantly lower than that without IF (43.1 ± 30.7 vs. 72.2 ± 45.3 Gy cm{sup 2}, p < 0.001). The contrast medium volume used with IF was significantly lower than that without IF (54.6 ± 21.9 vs. 65.7 ± 27.6 mL, p = 0.020).ConclusionsAlthough the contribution to improving the technical success rates was small in our study, IF can effectively reduce procedure time, radiation exposure, and volume of contrast medium during AVS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phantom Study Investigating the Accuracy of Manual and Automatic Image Fusion with the GE Logiq E9: Implications for use in Percutaneous Liver Interventions

PurposeTo determine the accuracy of automatic and manual co-registration methods for image fusion of three-dimensional computed tomography (CT) with real-time ultrasonography (US) for image-guided liver interventions.Materials and MethodsCT images of a skills phantom with liver lesions were acquired and co-registered to US using GE Logiq E9 navigation software. Manual co-registration was compared to automatic and semiautomatic co-registration using an active tracker. Also, manual point registration was compared to plane registration with and without an additional translation point. Finally, comparison was made between manual and automatic selection of reference points. In each experiment, accuracy of the co-registration method was determined by measurement of the residual displacement in phantom lesions by two independent observers.ResultsMean displacements for a superficial and deep liver lesion were comparable after manual and semiautomatic co-registration: 2.4 and 2.0 mm versus 2.0 and 2.5 mm, respectively. Both methods were significantly better than automatic co-registration: 5.9 and 5.2 mm residual displacement (p < 0.001; p < 0.01). The accuracy of manual point registration was higher than that of plane registration, the latter being heavily dependent on accurate matching of axial CT and US images by the operator. Automatic reference point selection resulted in significantly lower registration accuracy compared to manual point selection despite lower root-mean-square deviation (RMSD) values.ConclusionThe accuracy of manual and semiautomatic co-registration is better than that of automatic co-registration. For manual co-registration using a plane, choosing the correct plane orientation is an essential first step in the registration process. Automatic reference point selection based on RMSD values is error-prone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fundus image fusion in EYEPLAN software: An evaluation of a novel technique for ocular melanoma radiation treatment planning

Purpose: The purpose of this study is to evaluate a novel approach for treatment planning using digital fundus image fusion in EYEPLAN for proton beam radiation therapy (PBRT) planning for ocular melanoma. The authors used a prototype version of EYEPLAN software, which allows for digital registration of high-resolution fundus photographs. The authors examined the improvement in tumor localization by replanning with the addition of fundus photo superimposition in patients with macular area tumors. Methods: The new version of EYEPLAN (v3.05) software allows for the registration of fundus photographs as a background image. This is then used in conjunction with clinical examination, tantalum marker clips, surgeon's mapping, and ultrasound to draw the tumor contour accurately. In order to determine if the fundus image superimposition helps in tumor delineation and treatment planning, the authors identified 79 patients with choroidal melanoma in the macular location that were treated with PBRT. All patients were treated to a dose of 56 GyE in four fractions. The authors reviewed and replanned all 79 macular melanoma cases with superimposition of pretreatment and post-treatment fundus imaging in the new EYEPLAN software. For patients with no local failure, the authors analyzed whether fundus photograph fusion accurately depicted and confirmed tumor volumes as outlined in the original treatment plan. For patients with local failure, the authors determined whether the addition of the fundus photograph might have benefited in terms of more accurate tumor volume delineation. Results: The mean follow-up of patients was 33.6{+-}23 months. Tumor growth was seen in six eyes of the 79 macular lesions. All six patients were marginal failures or tumor miss in the region of dose fall-off, including one patient with both in-field recurrence as well as marginal. Among the six recurrences, three were managed by enucleation and one underwent retreatment with proton therapy. Three patients developed distant metastasis and all three patients have since died. The replanning of six patients with their original fundus photograph superimposed showed that in four cases, the treatment field adequately covered the tumor volume. In the other two patients, the overlaid fundus photographs indicated the area of marginal miss. The replanning with the fundus photograph showed improved tumor coverage in these two macular lesions. For the remaining patients without local failure, replanning with fundus photograph superimposition confirmed the tumor volume as drawn in the original treatment plan. Conclusions: Local control was excellent in patients receiving 56 GyE of PBRT for uveal melanomas in the macular region, which traditionally can be more difficult to control. Posterior lesions are better defined with the additional use of fundus image since they can be difficult to mark surgically. In one-third of treatment failing patients, the superposition of the fundus photograph would have clearly allowed improved localization of tumor. The current practice standard is to use the superimposition of the fundus photograph in addition to the surgeon's clinical and clip mapping of the tumor and ultrasound measurement to draw the tumor volume.

60 APPLIED LIFE SCIENCES↗

Unenhanced Cone Beam Computed Tomography and Fusion Imaging in Direct Percutaneous Sac Injection for Treatment of Type II Endoleak: Technical Note

AimTo evaluate safety, feasibility, technical success, and clinical success of direct percutaneous sac injection (DPSI) for the treatment of type II endoleaks (T2EL) using anatomical landmarks on cone beam computed tomography (CBCT) and fusion imaging (FI).Materials and MethodsEight patients with T2EL were treated with DPSI using CBCT as imaging guidance. Anatomical landmarks on unenhanced CBCT were used for referencing T2EL location in the first five patients, while FI between unenhanced CBCT and pre-procedural computed tomography angiography (CTA) was used in the remaining three patients. Embolization was performed with thrombin, glue, and ethylene–vinyl alcohol copolymer. Technical and clinical success, iodinated contrast utilization, procedural time, fluoroscopy time, and mean radiation dose were registered.ResultsDPSI was technically successful in all patients: the needle was correctly positioned at the first attempt in six patients, while in two of the first five patients the needle was repositioned once. Neither minor nor major complications were registered. Average procedural time was 45 min and the average administered iodinated contrast was 13 ml. Mean radiation dose of the procedure was 60.43 Gy cm{sup 2} and mean fluoroscopy time was 18 min. Clinical success was achieved in all patients (mean follow-up of 36 months): no sign of T2EL was reported in seven patients until last CT follow-up, while it persisted in one patient with stability of sac diameter.ConclusionsDPSI using unenhanced CBCT and FI is feasible and provides the interventional radiologist with an accurate and safe alternative to endovascular treatment with limited iodinated contrast utilization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗