Search NASA⌕ Search

SEARCH · Search NASA

Results for “image quality assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Retinal Image Quality Assessment for Spaceflight-Induced Vision Impairment Study

Long-term exposure to space microgravity poses significant risks for visual impairment. Evidence suggests such vision changes are linked to cephalad fluid shifts, prompting a need to directly quantify microgravity-induced retinal vascular changes. The quality of retinal images used for such vascular remodeling analysis, however, is dependent on imaging methodology. For our exploratory study, we hypothesized that retinal images captured using fluorescein imaging methodologies would be of higher quality in comparison to images captured without fluorescein. A semi-automated image quality assessment was developed using Vessel Generation Analysis (VESGEN) software and MATLAB® image analysis toolboxes. An analysis of ten images found that the fluorescein imaging modality provided a 36% increase in overall image quality (two-tailed p=0.089) in comparison to nonfluorescein imaging techniques.

retina↗

Retinal Image Quality Assessment for Spaceflight-Induced Visual Impairment Study

Medical reports have identified visual impairments as a risk associated with extended exposure to microgravity. Etiology of these ocular changes is currently unknown. Current hypotheses propose cephalad fluid shifts resulting from microgravity as the primary cause of ocular damage. One approach to studying ocular response to microgravity is by examining possible changes in retinal blood vessels using a NASA model of microgravity, the head-down tilt (HDT) of human subjects undergoing prolonged bed rest (BR). Retinal vessels in astronauts and BR subjects are monitored by Heidelberg Spectralis infrared (IR) imaging, in which retinal image quality is limited by insufficient resolution of small vessels. Yet small vessels respond and remodel most actively to physiological stress.For our NASA study of BR subjects, we identify retinal image quality as thecapability to capture vascular detail to acceptable resolution of small vessels. We therefore are analyzing Spectralis images acquired with fluorescein angiography(FA), where increased contrast significantly improves image resolution. The FA images are of normal subjects participating in a clinical study on diabeticretinopathy (US National Institutes of Health). We hypothesize that FA Spectralis images are of superior quality compared to non-FA Spectralis IR images.

Rodrigo Rene Rai Munoz Abujder↗

Geometric assessment of image quality using digital image registration techniques

Image registration techniques were developed to perform a geometric quality assessment of multispectral and multitemporal image pairs. Based upon LANDSAT tapes, accuracies to a small fraction of a pixel were demonstrated. Because it is insensitive to the choice of registration areas, the technique is well suited to performance in an automatic system. It may be implemented at megapixel-per-second rates using a commercial minicomputer in combination with a special purpose digital preprocessor.

Tisdale, G. E.↗

Visualization Quality Assessment

Understanding how inaccuracies in visualizations affect users’ perception and understanding of scientific data is hard. Inaccuracies in visualizations are quite common and could arise from a range of sources such as errors in the original dataset arising from compression artifacts, errors in the capturing device, noise during transmission of the data, effects due to the algorithm being used to convert data to visualization images, images generated from neural networks, and sources we have yet to discover. Many image quality assessment metrics have been developed to quantify image errors. However, these are usually focused on “natural images” rather than visualizations of scientific data. Common image quality assessment metrics (IQAs) include MSE, PSNR, perceptual metrics such SSIM, FSIM as well as perceptual metrics using deep learning approaches. However, a critical part of understanding how errors are perceived by humans, and subsequently developing more accurate quality assessment metrics, is through user evaluation studies. The goal of this software is to develop a visualization quality assessment (VQA) process that will enable the generation of VQAs that can be used to quantify errors in scientific data visualizations. The VQA development process will include software to support user evaluation experimental design, analysis of visualization differences against standard quality metrics, and the ability to develop additional VQA metrics specific to scientific visualization images.

Grosset, Andre↗

SAR calibration - An overview

Remote sensing with synthetic aperture radars (SAR's) is a rapidly developing field. Calibration of these sensors is required for the establishment of relationships between radar backscatter and geographical parameters. A review of recent progress in SAR calibration is presented. The quantities measured by SAR are defined and mathematical formulations of the three basic types of SAR images are developed. The establishment of scientific requirements for calibration and the difficulties involved are discussed. Image quality assessment is reviewed and the problems of radiometric calibration of SAR images using the radar equation and internal and external approaches are considered. Polarimetric radar calibration and the development of the necessary algorithms are described. Interferometric phase calibration and its associated problems are reviewed and future challenges in SAR calibration are discussed.

Freeman, Anthony↗

Beyond spot diagrams: end-user oriented optical design

In this talk, two examples are given of the process of translating user requirements into optimization and assessment tools. In the first place, recent work on the effects of aberrations on the perceived image quality of visual instruments is reviewed. The second example concerns the extraction of accurate spectroscopic information from pushbroom imaging spectrometers.

optical↗

Earth applications orbit analysis for a shuttle-mounted Multispectral Mapper

The earth remote sensing problem of orbit design to acquire images with inherent geometric and geodetic accuracy is addressed. The basis for precise orbit modeling is discussed. Various orbit propagation tools are compared. Orbit characteristics for a nominal case at shuttle altitude are displayed. Modeling Parameter sensitivities are evaluated to determine limits on orbit propagation accuracy versus time. It is found that attainable propagation accuracies are sufficient for image quality assessment over the short term at the 15m pixel size desired for a Multispectral Mapper.

Driver, J. M.↗

Vascular Patterning Analysis by VESGEN 2D/3D with Bioinformatics: Updates for Rodent Tissues

Fractally branching vascular systems are a complex physiological requirement shared by humans with all higher terrestrial life forms, including other vertebrates, insects, and higher land plants. Vascular trees, networks, and tree-network composites are therefore mapped and quantified by the VESsel GENeration Analysis (VESGEN) software according to weighted physiological vascular rules that include vessel connectivity, tapering and bifurcational branching. According to fluid dynamics, successful vascular transport depends upon a complex distributed system of highly regulated laminar flow. VESGEN has elucidated changes in vascular patterning resulting from inflammatory, developmental and other signaling pathways within numerous tissues of major model organisms important for Space Biology, especially for rodents. Important early stage regenerative opportunities have been identified by VESGEN vascular analysis for visual impairments in the human retina, and is currently being used for research into astronaut visual and ocular disorders associated with long duration missions. The VESGEN 2D software is a mature, automated, widely published capability for which beta testing and public release by NASA is planned for the upcoming year. Early-stage capabilities for VESGEN 3D analysis are under development for the rodent retina and intestine as prototype tissues. A prototype VESGEN 2D Bioinformatics software capability has also been developed to associate phenotypic changes in molecular expression with vascular structure and function. By new VESGEN bioinformatic innovations, expression patterns of the genetic, transcriptional, protein and other markers for regulatory molecules such as vascular endothelial growth factor (VEGF) and their receptors, often indicators of tissue oxygenation status, are co-localized with alterations in vascular pattern. Biomarkers are therefore mapped and quantified as information dimensions directly correlated with the spatial dimensions of a vascular pattern. Further important technology innovations by NASA include substantial image segmentation advances for more automated binary extraction of the grayscale vascular patterns, together with informative associated image quality assessments. Vascular mapping and quantification capabilities for the rodent retina and intestine are illustrated for VESGEN 2D, along with technology status reports on VESGEN 3D and Bioinformatic capabilities. Research partially supported by Ames Center Innovation Awards.

Parsons-Wingerter, P.↗

Wind sets from SMS images - An assessment of quality for GATE

The paper analyzes the accuracy, representativeness, and reproducibility of tracer winds in the 1974 GARP Atlantic Tropical Experiment whose data are used as ground truth. The tracer winds were generated by tracking clouds in SMS (Synchronous Meteorological Satellite) images. Data availability limits comparisons to satellite winds with ship winds at the surface and at 250 mb. Attention is focused on how accurately the cloud displacements can be measured and on the extent to which the cloud displacements represent the wind field. Operator errors in obtaining the cloud displacements are examined in a series of reproducibility tests and wind sets. Differences between proximate satellite and ship winds were all under 3 m/sec. Representativeness of cloud tracers for cumulus and cirrus level flow is found to be good within the accuracy of currently available ground truth data.

Suchman, D.↗

An experimental assessment of the imaging quality of the low energy gamma-ray telescope ZEBRA

One gamma-ray detection plane of the ZEBRA telescope, consisting of nine position sensitive scintillation crystal bars designed to operate over the spectral range 0.2 to 10 MeV, has been constructed in the laboratory. A series of experimental images has been generated using a scaled down flight pattern mask in conjunction with a diverging gamma-ray beam. Point and extended sources have been imaged in order to assess quantitatively the performance of the system.

Butler, R. C.↗

Image Analysis for Rapid Assessment and Quality-Based Sorting of Corn Stover

Imaging in the visible spectrum is a low-cost tool that can be readily deployed for in-field or over-belt monitoring of biomass quality for bio-refining operations. Rapid image analysis coupled with innovative preprocessing may reduce the impacts of feedstock variability through identification of contaminants or other material attributes to guide selective sorting and quality management. Image analysis was employed to evaluate the quality of corn stover in red-green-blue (RGB) chromatic space. This study used controlled, bench-scale imaging as a proof-of-concept for rapid quality assessment of corn stover based on variations in material attributes, including chemical and physical attributes, that relate to biological degradation and soil contamination. Additionally, logistic regression-based classification algorithms were used to develop a method for biomass screening as a function of biological degradation or soil contamination. This study demonstrated the use of image analysis to extract features from RGB color space to investigate variations in critical material attributes from chemical composition of corn stover. Fourier transform infrared (FT-IR) suggested a correlation between red band intensity and biological degradation, while detailed surface texture analysis was found to distinguish among variations in ash. These insights offer promise for development of a rapid screening tool that could be deployed by farmers for in-field assessment of biomass quality or biorefinery operators for in-line sorting and process optimization.

09 BIOMASS FUELS↗

Uncertainty quantification and propagation in lithium-ion battery electrodes using bayesian convolutional neural networks

The complex nature of manufacturing processes stipulates electrodes to possess high variability with increased heterogeneity during production. X-ray computed tomography imaging has proved to be critical in visualizing the complicated stochastic particle distribution of as-manufactured electrodes in lithium-ion batteries. However, accurate prediction of their electrochemical performance necessitates precise evaluation of kinetic and transport properties from real electrodes. Image segmentation that characterizes voxels to particle/pore phase is often meticulous and fraught with subjectivity owing to a myriad of unconstrained choices and filter algorithms. Here we utilize a Bayesian convolutional neural network to tackle segmentation subjectivity and quantify its pertinent uncertainties. Otsu inter-variance and Blind/Referenceless Imaging Spatial Quality Evaluator are used to assess the relative image quality of grayscale tomograms, thus evaluating the uncertainty in the derived microstructural attributes. We analyze how image uncertainty is correlated with the uncertainties and magnitude of kinetic and transport properties of an electrode, further identifying pathways of uncertainty propagation within microstructural attributes. The coupled effect of spatial heterogeneity and microstructural anisotropy on the uncertainty quantification of transport parameters is also understood. This work demonstrates a novel methodology to extract microstructural descriptors from real electrode images through quantification of associated uncertainties and discerning the relative strength of their propagation, thus facilitating feedback to manufacturing processes from accurate image based electrochemical simulations.

25 ENERGY STORAGE↗

The applications developmental data system

This paper describes a research and development system under development at NASA Goddard Space Flight Center (GSFC) for processing Landsat-4 Thematic Mapper (TM) data at high throughput rates. This system, called the Applications Developmental Data System (ADDS) is being developed with 2 objectives. First, during the initial year of Landsat-4 operations, ADDS provides an essential link in processing the TM images for image data quality assessment. The second objective is to demonstrate the ability to produce a radiometrically corrected TM image in 8 minutes and a geometrically correct image in 16 minutes. The processing rates currently achieved are presented.

Mocarsky, W. L.↗

A combination interferometric and morphological image processing approach to rapid quality assessment of additively manufactured cellular truss core components

Advanced manufacturing (AM) processes such as laser powder bed fusion (LPBF) are increasingly capable of fabricating components with useful and unprecedented mechanical properties by incorporating complex internal bracing structures. From the standpoint of quality control and assessment, however, internally complex assemblies present significant build-verification challenges. Here we propose a hybrid approach to the inspection involving the application of computer-aided speckle interferometry (CASI) and morphological image processing as a rapid, inexpensive, and facile method for AM quality control. The described methodology has low capital equipment costs, is full-field and non-contact, can be used in an industrial setting, and has very low requirements in terms of operator training and expertise. Consisting primarily of the combination of image processing software with a simple optical system of variable sensitivity, the method is shown to be effective for inspection of a titanium honeycomb component subjected to differential pressure. Results are compared to those achieved with computed tomography (CT), immersion ultrasound testing (UT), and optical holographic interferometry. Here we propose several possible processing strategies for automated quality assessment based on this powerful hybrid approach.

36 MATERIALS SCIENCE↗

Evaluation of multichannel Wiener filters applied to fine resolution passive microwave images of first-year sea ice

The effectivity of multichannel Wiener filters to improve images obtained with passive microwave systems was investigated by applying Wiener filters to passive microwave images of first-year sea ice. Four major parameters which define the filter were varied: the lag or pixel offset between the original and the desired scenes, filter length, the number of lines in the filter, and the weight applied to the empirical correlation functions. The effect of each variable on the image quality was assessed by visually comparing the results. It was found that the application of multichannel Wiener theory to passive microwave images of first-year sea ice resulted in visually sharper images with enhanced textural features and less high-frequency noise. However, Wiener filters induced a slight blocky grain to the image and could produce a type of ringing along scan lines traversing sharp intensity contrasts.

Full, William E.↗

Physics‐based iterative reconstruction for dual‐source and flying focal spot computed tomography

Purpose For single‐source helical Computed Tomography (CT), both Filtered‐Back Projection (FBP) and statistical iterative reconstruction have been investigated. However, for dual‐source CT with flying focal spot (DS‐FFS CT), a statistical iterative reconstruction that accurately models the scanner geometry and acquisition physics remains unknown to researchers. Therefore, our purpose is to present a novel physics‐based iterative reconstruction method for DS‐FFS CT and assess its image quality. Methods Our algorithm uses precise physics models to reconstruct from the native cone‐beam geometry and interleaved dual‐source helical trajectory of a DS‐FFS CT. To do so, we construct a noise physics model to represent data acquisition noise and a prior image model to represent image noise and texture. In addition, we design forward system models to compute the locations of deflected focal spots, the dimension, and sensitivity of voxels and detector units, as well as the length of intersection between x‐rays and voxels. The forward system models further represent the coordinated movement between the dual sources by computing their x‐ray coverage gaps and overlaps at an arbitrary helical pitch. With the above models, we reconstruct images by an advanced Consensus Equilibrium (CE) numerical method to compute the maximum a posteriori estimate to a joint optimization problem that simultaneously fits all models. Results We compared our reconstruction with Siemens ADMIRE, which is the clinical standard hybrid iterative reconstruction (IR) method for DS‐FFS CT, in terms of spatial resolution, noise profile, and image artifacts through both phantoms and clinical scan datasets. Experiments show that our reconstruction has a higher spatial resolution, with a Task‐Based Modulation Transfer Function (MTF task ) consistently higher than the clinical standard hybrid IR. In addition, our reconstruction shows a reduced magnitude of image undersampling artifacts than the clinical standard. Conclusions By modeling a precise geometry and avoiding data rebinning or interpolation, our physics‐based reconstruction achieves a higher spatial resolution and fewer image artifacts with smaller magnitude than the clinical standard hybrid IR.

Wang, Xiao↗

Image registration for accurate electrode deformation analysis in operando microscopy of battery materials

Operando imaging techniques have become increasingly valuable in both battery research and manufacturing. However, the reliability of these methods can be compromised by instabilities in the imaging setup and operando cells, particularly when utilizing high-resolution imaging systems. The acquired imaging data often include features arising from both undesirable system vibrations and drift, as well as the scientifically relevant deformations occurring in the battery sample during cell operation. For meaningful analysis, it is crucial to distinguish and separately evaluate these two factors. To address these challenges, we employ a suite of advanced image-processing techniques. These include fast Fourier transform analysis in the frequency domain, power spectrum-based assessments for image quality, as well as rigid and non-rigid image-registration methods. These techniques allow us to identify and exclude blurred images, correct for displacements caused by motor vibrations and sample holder drift and, thus, prevent unwanted image artifacts from affecting subsequent analyses and interpretations. Additionally, we apply optical flow analysis to track the dynamic deformation of battery electrode materials during electrochemical cycling. This enables us to observe and quantify the evolving mechanical responses of the electrodes, offering deeper insights into battery degradation. Together, these methods ensure more accurate image analysis and enhance our understanding of the chemomechanical interplay in battery performance and longevity.

Sun, Tianxiao↗