Search NASA⌕ Search

SEARCH · Search NASA

Results for “image quality assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Retinal Image Quality Assessment for Spaceflight-Induced Vision Impairment Study

Long-term exposure to space microgravity poses significant risks for visual impairment. Evidence suggests such vision changes are linked to cephalad fluid shifts, prompting a need to directly quantify microgravity-induced retinal vascular changes. The quality of retinal images used for such vascular remodeling analysis, however, is dependent on imaging methodology. For our exploratory study, we hypothesized that retinal images captured using fluorescein imaging methodologies would be of higher quality in comparison to images captured without fluorescein. A semi-automated image quality assessment was developed using Vessel Generation Analysis (VESGEN) software and MATLAB® image analysis toolboxes. An analysis of ten images found that the fluorescein imaging modality provided a 36% increase in overall image quality (two-tailed p=0.089) in comparison to nonfluorescein imaging techniques.

retina↗

Retinal Image Quality Assessment for Spaceflight-Induced Visual Impairment Study

Medical reports have identified visual impairments as a risk associated with extended exposure to microgravity. Etiology of these ocular changes is currently unknown. Current hypotheses propose cephalad fluid shifts resulting from microgravity as the primary cause of ocular damage. One approach to studying ocular response to microgravity is by examining possible changes in retinal blood vessels using a NASA model of microgravity, the head-down tilt (HDT) of human subjects undergoing prolonged bed rest (BR). Retinal vessels in astronauts and BR subjects are monitored by Heidelberg Spectralis infrared (IR) imaging, in which retinal image quality is limited by insufficient resolution of small vessels. Yet small vessels respond and remodel most actively to physiological stress.For our NASA study of BR subjects, we identify retinal image quality as thecapability to capture vascular detail to acceptable resolution of small vessels. We therefore are analyzing Spectralis images acquired with fluorescein angiography(FA), where increased contrast significantly improves image resolution. The FA images are of normal subjects participating in a clinical study on diabeticretinopathy (US National Institutes of Health). We hypothesize that FA Spectralis images are of superior quality compared to non-FA Spectralis IR images.

Rodrigo Rene Rai Munoz Abujder↗

Geometric assessment of image quality using digital image registration techniques

Image registration techniques were developed to perform a geometric quality assessment of multispectral and multitemporal image pairs. Based upon LANDSAT tapes, accuracies to a small fraction of a pixel were demonstrated. Because it is insensitive to the choice of registration areas, the technique is well suited to performance in an automatic system. It may be implemented at megapixel-per-second rates using a commercial minicomputer in combination with a special purpose digital preprocessor.

Tisdale, G. E.↗

SAR calibration - An overview

Remote sensing with synthetic aperture radars (SAR's) is a rapidly developing field. Calibration of these sensors is required for the establishment of relationships between radar backscatter and geographical parameters. A review of recent progress in SAR calibration is presented. The quantities measured by SAR are defined and mathematical formulations of the three basic types of SAR images are developed. The establishment of scientific requirements for calibration and the difficulties involved are discussed. Image quality assessment is reviewed and the problems of radiometric calibration of SAR images using the radar equation and internal and external approaches are considered. Polarimetric radar calibration and the development of the necessary algorithms are described. Interferometric phase calibration and its associated problems are reviewed and future challenges in SAR calibration are discussed.

Freeman, Anthony↗

Beyond spot diagrams: end-user oriented optical design

In this talk, two examples are given of the process of translating user requirements into optimization and assessment tools. In the first place, recent work on the effects of aberrations on the perceived image quality of visual instruments is reviewed. The second example concerns the extraction of accurate spectroscopic information from pushbroom imaging spectrometers.

optical↗

Earth applications orbit analysis for a shuttle-mounted Multispectral Mapper

The earth remote sensing problem of orbit design to acquire images with inherent geometric and geodetic accuracy is addressed. The basis for precise orbit modeling is discussed. Various orbit propagation tools are compared. Orbit characteristics for a nominal case at shuttle altitude are displayed. Modeling Parameter sensitivities are evaluated to determine limits on orbit propagation accuracy versus time. It is found that attainable propagation accuracies are sufficient for image quality assessment over the short term at the 15m pixel size desired for a Multispectral Mapper.

Driver, J. M.↗

Vascular Patterning Analysis by VESGEN 2D/3D with Bioinformatics: Updates for Rodent Tissues

Fractally branching vascular systems are a complex physiological requirement shared by humans with all higher terrestrial life forms, including other vertebrates, insects, and higher land plants. Vascular trees, networks, and tree-network composites are therefore mapped and quantified by the VESsel GENeration Analysis (VESGEN) software according to weighted physiological vascular rules that include vessel connectivity, tapering and bifurcational branching. According to fluid dynamics, successful vascular transport depends upon a complex distributed system of highly regulated laminar flow. VESGEN has elucidated changes in vascular patterning resulting from inflammatory, developmental and other signaling pathways within numerous tissues of major model organisms important for Space Biology, especially for rodents. Important early stage regenerative opportunities have been identified by VESGEN vascular analysis for visual impairments in the human retina, and is currently being used for research into astronaut visual and ocular disorders associated with long duration missions. The VESGEN 2D software is a mature, automated, widely published capability for which beta testing and public release by NASA is planned for the upcoming year. Early-stage capabilities for VESGEN 3D analysis are under development for the rodent retina and intestine as prototype tissues. A prototype VESGEN 2D Bioinformatics software capability has also been developed to associate phenotypic changes in molecular expression with vascular structure and function. By new VESGEN bioinformatic innovations, expression patterns of the genetic, transcriptional, protein and other markers for regulatory molecules such as vascular endothelial growth factor (VEGF) and their receptors, often indicators of tissue oxygenation status, are co-localized with alterations in vascular pattern. Biomarkers are therefore mapped and quantified as information dimensions directly correlated with the spatial dimensions of a vascular pattern. Further important technology innovations by NASA include substantial image segmentation advances for more automated binary extraction of the grayscale vascular patterns, together with informative associated image quality assessments. Vascular mapping and quantification capabilities for the rodent retina and intestine are illustrated for VESGEN 2D, along with technology status reports on VESGEN 3D and Bioinformatic capabilities. Research partially supported by Ames Center Innovation Awards.

Parsons-Wingerter, P.↗

Wind sets from SMS images - An assessment of quality for GATE

The paper analyzes the accuracy, representativeness, and reproducibility of tracer winds in the 1974 GARP Atlantic Tropical Experiment whose data are used as ground truth. The tracer winds were generated by tracking clouds in SMS (Synchronous Meteorological Satellite) images. Data availability limits comparisons to satellite winds with ship winds at the surface and at 250 mb. Attention is focused on how accurately the cloud displacements can be measured and on the extent to which the cloud displacements represent the wind field. Operator errors in obtaining the cloud displacements are examined in a series of reproducibility tests and wind sets. Differences between proximate satellite and ship winds were all under 3 m/sec. Representativeness of cloud tracers for cumulus and cirrus level flow is found to be good within the accuracy of currently available ground truth data.

Suchman, D.↗

An experimental assessment of the imaging quality of the low energy gamma-ray telescope ZEBRA

One gamma-ray detection plane of the ZEBRA telescope, consisting of nine position sensitive scintillation crystal bars designed to operate over the spectral range 0.2 to 10 MeV, has been constructed in the laboratory. A series of experimental images has been generated using a scaled down flight pattern mask in conjunction with a diverging gamma-ray beam. Point and extended sources have been imaged in order to assess quantitatively the performance of the system.

Butler, R. C.↗

The applications developmental data system

This paper describes a research and development system under development at NASA Goddard Space Flight Center (GSFC) for processing Landsat-4 Thematic Mapper (TM) data at high throughput rates. This system, called the Applications Developmental Data System (ADDS) is being developed with 2 objectives. First, during the initial year of Landsat-4 operations, ADDS provides an essential link in processing the TM images for image data quality assessment. The second objective is to demonstrate the ability to produce a radiometrically corrected TM image in 8 minutes and a geometrically correct image in 16 minutes. The processing rates currently achieved are presented.

Mocarsky, W. L.↗

Evaluation of multichannel Wiener filters applied to fine resolution passive microwave images of first-year sea ice

The effectivity of multichannel Wiener filters to improve images obtained with passive microwave systems was investigated by applying Wiener filters to passive microwave images of first-year sea ice. Four major parameters which define the filter were varied: the lag or pixel offset between the original and the desired scenes, filter length, the number of lines in the filter, and the weight applied to the empirical correlation functions. The effect of each variable on the image quality was assessed by visually comparing the results. It was found that the application of multichannel Wiener theory to passive microwave images of first-year sea ice resulted in visually sharper images with enhanced textural features and less high-frequency noise. However, Wiener filters induced a slight blocky grain to the image and could produce a type of ringing along scan lines traversing sharp intensity contrasts.

Full, William E.↗

Study on spectral/radiometric characteristics of the Thematic Mapper for land use applications

Progress under the LANDSAT-4 and 5 Image Data Quality Assessment program for the Thematic Mapper is described. An initial screening of LANDSAT-5 data is performed. Tools are developed to allow access to TIPS-format data. Analysis of scan direction related signal droop is resumed with detailed analysis of nighttime data. A new mathematical model is developed to describe the effect. Coherent noise of a lower frequency than previously reported is discovered and analyzed. Coincident LANDSAT-4 TM and MSS data are analyzed to improve understanding of radiometric relationships between similar wavebands in the two sensors.

Malila, W. A.↗

Study of spectral/radiometric characteristics of the Thematic Mapper for land use applications

Progress during the Environmental Research Institute of Michigan-ERIM's and 5 image data quality assessment program for the thematic mapper is described. Analyses of LANDSAT 5 TM radiometric characteristics were performed. Effects which had earlier been found in LANDSAT 4 TM data were found to be present in LANDSAT 5 data as well, including: (1) scan direction related signal droop; (2) scan correlated level shifts; and (3) low frequency coherent noise. Coincident LANDSAT 4 and 5 raw TM data were analyzed, and band by band relationships between the two sensors were derived. Earlier efforts which developed an information theoretic measure of multispectral information content were continued, comparing TM and MSS information content.

Malila, W. A.↗

Study of spectral/radiometric characteristics of the Thematic Mapper for land use applications

Progress during ERIM's tenth quarter of effort under the LANDSAT-4 and 5 Image Data Quality Assessment program for the Thematic Mapper is described. Coincident LANDSAT-4 and 5 fully corrected (CCT-PT) TM data are analyzed in more detail and revised band-by-band relationships between the two sensors derived. An analysis technique employing the matching of cumulative distributions is developed and used and is believed to offer advantages over the histogram matching procedure currently used to produce LANDSAT data. Multiplicative factors ranging from 0.987 to 1.145 and offsets ranging from -2.7 to -6.2 video quantum levels are required to cause LANDSAT-5 data to match LANDSAT-4 data values. Evidence of low level clipping is found in TM Bands 5 and 7 of LANDSAT-5 but not LANDSAT-4. Analysis of the information content of LANDSAT TM and MSS data is continued. Components of information loss are identified and quantified and the effects of coarsened quantization are explored.

Malila, W. A.↗

Digital Beamforming Based RFI Mitigation for Synthetic Aperture Radar

An increasing challenge for P-band Synthetic Aperture Radar (SAR) is Radio Frequency Interference (RFI). RFI results in image distortions and degrades the derived science products. This makes it critical to apply RFI removal techniques to restore the image quality. New advanced techniques can be achieved with Digital Beamforming (DBF) radars such as EcoSAR. In this paper, we present a Range-Dependent Time Minimum Variance Distortionless Response (RDTMVDR) Beamformer and apply it to EcoSAR flight data during post-processing. The antenna pattern (AP) is adaptively changed for each range line which increases the RFI suppression compared to a fixed AP for each pulse. The interferometric image quality is assessed before and after RFI suppression.

Bollian, Tobias↗

Stereosat - A new astrodynamics challenge

The paper investigates the astrodynamics requirements for a spacecraft which produces stereo images of the land masses of the earth for use in geoscience investigations, cartography and earth resource exploration. It describes a candidate Stereosat imaging product, presents criteria for evaluating potential image quality and usability, and assesses the impact of various spacecraft and astrodynamic factors on image quality. Several challenges are identified and discussed, namely (1) securing adequate image quality for pixel level elevation measurements, (2) determining absolute location of imaged phenomena in remote regions, (3) satisfying the long-term orbit prediction requirements, and (4) transmitting accurate orbit data along with the image data stream. Meeting these challenges will greatly enhance operational facility.

Driver, J. M.↗

Smart Ultrasound Remote Guidance Experiment (SURGE)- Concept of Operations Evaluation for Using Remote Guidance Ultrasound for Planetary Space Flight

Introduction Use of remote guidance (RG) techniques aboard the International Space Station (ISS) has enabled astronauts to collect diagnostic-level ultrasound images. Exploration class missions will require this cohort of (typically) non-formally trained sonographers to operate with greater autonomy given the longer communication delays (2 seconds for ISS vs. >6 seconds for missions beyond the Moon) and communication blackouts. To determine the feasibility and training requirements for autonomous ultrasound image collection by non-expert ultrasound operators, ultrasound images were collected from a similar cohort using three different image collection protocols: RG only, RG with a computer-based learning tool (LT), and autonomous image collection with LT. The groups were assessed for both image quality and time to collect the images. Methods Subjects were randomized into three groups: RG only, RG with LT, and autonomous with LT. Each subject received 10 minutes of standardized training before the experiment. The subjects were tasked with making the following ultrasound assessments: 1) bone fracture and 2) focused assessment with sonography in trauma (FAST) to assess a patient s abdomen. Human factors-related questionnaire data were collected immediately after the assessments. Results The autonomous group did not out-perform the two groups that received RG. The mean time for the autonomous group to collect images was less than the RG groups, however the mean image quality for the autonomous group was less compared to both RG groups. Discussion Remote guidance continues to produce higher quality ultrasound images than autonomous ultrasound operation. This is likely due to near-instant feedback on image quality from the remote guider. Expansion in communication time delays, however, diminishes the capability to provide this feedback, thus requiring more autonomous ultrasound operation. The LT has the potential to be an excellent training and coaching component for autonomous ultrasound image collection during exploration missions.

Hurst, Victor, IV↗

Thematic Mapper image quality - Registration, noise, and resolution

The Landsat-4 satellite has two new imaging radiometers, including the redesigned Multispectral Scanner (MSS) and the Thematic Mapper (TM). The present investigation is concerned with an assessment of TM image quality on the basis of a study of band-to-band registration, periodic noise, and spatial resolution. In the TM images analyzed, the band-to-band registration accuracy of the instrument is very good. A few imperfections were found. Once a stable misregistration is removed, the TM should also meet its registration specifications between focal planes. Spatial resolution analyses in terms of MTF were performed in comparison modes. The forward and backward scans were shown to have virtually identical MTFs.

Wrigley, R. C.↗