Search NASA⌕ Search

SEARCH · Search NASA

Results for “image spectrometer instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of the microcalorimeter and anticoincidence detector for the Line Emission Mapper x-ray probe

The Line Emission Mapper (LEM) is an x-ray probe mission concept that is designed to provide unprecedented insight into the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. LEM incorporates a light-weight x-ray optic with a large-format microcalorimeter array. The LEM detector utilizes a 14k pixel array of transition-edge sensors (TESs) that will provide <2.5 eV spectral resolution over the energy range 0.2 to 2 keV, along with a field-of-view of 30 arcmin. The microcalorimeter array and readout builds upon the technology developed for the European Space Agency’s (ESA’s) Athena/x-ray Integral Field Unit. Here, we present a detailed overview of the base- line microcalorimeter design, its performance characteristics, including a detailed energy resolution budget and the expected count-rate capability. In addition, we outline the current status and plan for continued technology maturation. Behind the LEM array sits a high-efficiency TES-based anticoincidence (antico) detector that will reject cosmic-ray background events. We will briefly describe the design of the antico and plan for continued development.

47 OTHER INSTRUMENTATION↗

A new μ -high energy resolution fluorescence detection microprobe imaging spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 6-2

In this report we describe a new synchrotron X-ray Fluorescence (XRF) imaging instrument with an integrated High Energy Fluorescence Detection X-ray Absorption Spectroscopy (HERFD-XAS) spectrometer at the Stanford Synchrotron Radiation Lightsource at beamline 6-2. The X-ray beam size on the sample can be defined via a range of pinhole apertures or focusing optics. XRF imaging is performed using a continuous rapid scan system with sample stages covering a travel range of 250 × 200 mm 2 , allowing for multiple samples and/or large samples to be mounted. The HERFD spectrometer is a Johann-type with seven spherically bent 100 mm diameter crystals arranged on intersecting Rowland circles of 1 m diameter with a total solid angle of about 0.44% of 4π sr. A wide range of emission lines can be studied with the available Bragg angle range of ~64.5°–82.6°. With this instrument, elements in a sample can be rapidly mapped via XRF and then selected features targeted for HERFD-XAS analysis. Furthermore, utilizing the higher spectral resolution of HERFD for XRF imaging provides better separation of interfering emission lines, and it can be used to select a much narrower emission bandwidth, resulting in increased image contrast for imaging specific element species, i.e., sparse excitation energy XAS imaging. This combination of features and characteristics provides a highly adaptable and valuable tool in the study of a wide range of materials.

47 OTHER INSTRUMENTATION↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Multichannel Doppler fiber-imager spectrometer for spatiotemporal characterization of high-intensity laser-driven plasmas

Here, we demonstrate a flexible multichannel fiber-based imaging Doppler spectrometer to characterize plasmas in high intensity (≥1 × 10 18 W/cm 2 ) laser-plasma experiments at high repetition rates. This instrument collects data from ×21 different plasma locations combining optical fibers and a single imaging spectrometer. This diagnostic maps the plasma velocity evolution as a function of time with sub-pico-second resolution. Experimental results showing 2D velocity measurements of plasma with 20 μm spatial resolution are presented. Intensities of the order of 10 18 W/cm 2 were used to generate a plasma, while a much less intense, frequency doubled (400 nm), probe beam (10 11 W/cm 2 ) was used to measure the Doppler shift from the plasma critical surface. The instrument can be scaled to a larger number of channels (e.g., 100) still using a single spectrometer.

47 OTHER INSTRUMENTATION↗

Integrating very-high-resolution UAS data and airborne imaging spectroscopy to map the fractional composition of Arctic plant functional types in Western Alaska

Widespread changes in vegetation cover and composition are driving strong impacts on Arctic ecosystem functioning and global climate feedbacks. An accurate characterization of tundra vegetation composition is required to understand how the Arctic will respond to future climate change. However, quantifying tundra vegetation composition over large areas is challenging as commonly-used satellite observations are too coarse, spatially and spectrally, to differentiate low-lying tundra vegetation types. Recent airborne and spaceborne imaging spectroscopy platforms provide better data to characterize vegetation composition. Yet, our ability to characterize vegetation composition with imaging spectroscopy remains largely unexplored in the Arctic, particularly due to a lack of ground observations needed to train and test classification models. To address this problem, we collected very-high-resolution (VHR, ~5 cm) unoccupied aerial system (UAS) imagery at three low-Arctic tundra sites located on the Seward Peninsula, western Alaska. In this paper, we examine the feasibility of integrating imagery from the UAS and the hyperspectral Airborne Visible/Infrared Imaging Spectrometer, Next Generation (AVIRIS-NG) airborne instrument to map the fractional composition of 12 key Arctic plant functional types (PFTs). To this end, we first mapped the 12 PFTs from our VHR UAS imagery using random forest classification. We then used these UAS-derived PFT maps as ground truth to develop partial least squares regression (PLSR) models to predict the fractional cover (FCover) of each PFT from AVIRIS-NG imagery. Further, we evaluated the performance of our PLSR models using reserved UAS samples, as well as by mapping PFT FCover and dominant PFT for large tundra landscapes. Our results show that 1) Arctic PFTs can be effectively mapped using VHR UAS imagery, with overall accuracy between 86% and 92%, 2) when the UAS mapped PFTs were used to inform PLSR scaling models, the FCover of the 12 PFTs could be effectively estimated from AVIRIS-NG imagery with a mean absolute error (MAE) <0.13, and 3) our PLSR models outperformed traditional, fully constrained least-squares (FCLS) linear mixture analysis and produced high-quality, spatially contiguous PFT FCover and PFT maps that captured vegetation spatial patterns with similar accuracy to those developed from UAS imagery. The developed PLSR models have the potential to be broadly applied for quantifying vegetation composition with AVIRIS-NG images to help monitor tundra vegetation dynamics and improve process-based modeling of tundra ecosystems.

54 ENVIRONMENTAL SCIENCES↗

NEON AOP Imaging Spectroscopy Survey of Upper East River Colorado Watersheds: Raw-Space Radiance and Observational Variable Dataset

Lawrence Berkeley National Laboratory (LBNL) contracted the National Ecological Observatory Network Airborne Observation Platform (NEON AOP) to observe watersheds of interest near Crested Butte, CO with remotely sensed data including imaging spectroscopy. The flight box design encompassed the watersheds, and flight design targeted a minimum of 30% overlap between adjacent flight lines. The total area surveyed was 334 km2 across 72 lines. Flight lines were oriented north-south for consistency in solar illumination geometry. Seven days were required to cover the flight area. Some areas were flown additional times to improve data quality or temporal coincidence between airborne acquisitions and field sampling. In total, 102 lines were collected and can be downloaded here: https://portal.nersc.gov/wfsfa/doi-10-15485-1617204/. The instrument used for the acquisition was an Airborne Visible-Infrared Imaging Spectrometer - Next Generation (AVIRIS-NG), which records radiance within 426 contiguous spectral bands in the wavelength range from 380 to 2510 nm. The instrument was flown at a target aboveground altitude of 1000 m for a processed data spatial resolution of 1 m. These data are non-orthorectified, radiance data that require further processing prior to use as a surface reflectance data set.

2018 NEON and 2025 CHESS Campaigns↗

Optical calibration of the SuperCam instrument body unit spectrometers

The SuperCam remote sensing instrument on NASA’s Perseverance rover is capable of four spectroscopic techniques, remote micro-imaging, and audio recording. These analytical techniques provide details of the chemistry and mineralogy of the rocks and soils probed in the Jezero Crater on Mars. Here we present the methods used for optical calibration of the three spectrometers covering the 243–853 nm range used by three of the four spectroscopic techniques. We derive the instrument optical response, which characterizes the instrument sensitivity to incident radiation as a function of a wavelength. The instrument optical response function derived here is an essential step in the interpretation of the spectra returned by SuperCam as it converts the observed spectra, reported by the instrument as “digital counts” from an analog to digital converter, into physical values of spectral radiance.

Legett, Carey (ORCID:0000000247412841)↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

Analysis of Hybrid Gas–Dust Outbursts Observed at 67P/Churyumov–Gerasimenko

Cometary outbursts offer a valuable window into the composition of comet nuclei with their forceful ejection of dust and volatiles in explosive events, revealing the interior components of the comet. Understanding how different types of outbursts influence the dust properties and volatile abundances, to better interpret what signatures can be attributed to primordial composition and what features are the result of processing, is an important task best undertaken with a multi-instrument approach. The European Space Agency Rosetta mission to 67P/Churyumov–Gerasimenko carried a suite of instruments capable of carrying out this task in the near-nucleus coma with unprecedented spatial and spectral resolution. In this work, we discuss two outbursts that occurred 2015 November 7 and were observed by three instruments on board: the Alice ultraviolet spectrograph, the Visual Infrared and Thermal Imaging Spectrometer, and the Optical, Spectroscopic, and Infrared Remote Imaging System. Together, the observations show that mixed gas and dust outbursts can have different spectral signatures representative of their initiating mechanisms, with the first outburst showing indicators of a cliff collapse origin and the second more representative of fresh volatiles being exposed via a deepening fracture. This analysis opens up the possibility of remote spectral classification of cometary outbursts with future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission

We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.

Astronomy and AstroPhysics↗

Spectrometer-free quantitative vapor sensing and classification via spatiotemporal imaging of porous silicon metasurfaces

Metasurfaces offer a compact platform for optical vapor sensing, but their practical deployment has been limited by weak evanescent light–matter interactions and reliance on spectrally resolved instrumentation. Here, we report porous silicon (pSi) metasurfaces for spectrometer-free quantitative detection of volatile organic compounds (VOCs) with strongly enhanced light–matter interaction. The engineered porosity increases sensitivity by >100× relative to non-porous dielectric metasurfaces, enabling limits of detection of 1.65 ppm for methanol and 9.1 ppm for ethanol across a broad dynamic range (<10 ppm to >103 ppm). Imaging-based readout provides a lightweight, spectrometer-free pathway for real-time quantitative sensing. Beyond quantitative detection, the mesoporous architecture introduces adsorption–desorption kinetics as an additional information channel. Analysis of the resulting spatiotemporal signatures enables kinetic fingerprinting without reliance on infrared spectral features or surface functionalization, and a lightweight machine-learning classifier differentiates acetone, methanol, ethanol, and isopropanol with 91.6% accuracy. These results establish porous metasurfaces as spatiotemporal sensing elements that couple quantitative vapor detection with kinetic fingerprinting through real-time dynamical responses, enabling low-cost, high-performance optical sensors.

Dash, Tomoshree [Clemson University]↗

Simulated JWST Data Sets for Multispectral and Hyperspectral Image Fusion

The James Webb Space Telescope (JWST) will provide multispectral and hyperspectral infrared images of a large number of astrophysical scenes. Multispectral images will have the highest angular resolution, while hyperspectral images (e.g., with integral field unit spectrometers) will provide the best spectral resolution. This paper aims at providing a comprehensive framework to generate an astrophysical scene and to simulate realistic hyperspectral and multispectral data acquired by two JWST instruments, namely, NIRCam Imager and NIRSpec IFU. We want to show that this simulation framework can be resorted to assess the benefits of fusing these images to recover an image of high spatial and spectral resolutions. To do so, we make a synthetic scene associated with a canonical infrared source, the Orion Bar. We develop forward models including corresponding noises for the two JWST instruments based on their physical features. JWST observations are then simulated by applying the forward models to the aforementioned synthetic scene. We test a dedicated fusion algorithm we developed on these simulated observations. We show that the fusion process reconstructs the high spatio-spectral resolution scene with a good accuracy on most areas, and we identify some limitations of the method to be tackled in future works. The synthetic scene and observations presented in the paper can be used, for instance, to evaluate instrument models, pipelines, or more sophisticated algorithms dedicated to JWST data analysis. Besides, fusion methods such as the one presented in this paper are shown to be promising tools to fully exploit the unprecedented capabilities of the JWST.

79 ASTRONOMY AND ASTROPHYSICS↗

Construction of precision sMDT detector for the ATLAS Muon Spectrometer upgrade

Here, this paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 μm. The positions of the platforms for alignment and magnetic field sensors are all installed well within the required precision. The cosmic ray test measurements show single wire tracking resolution of 100 ± 7 μm with an average detection efficiency above 99%. The infrastructure, tooling, techniques, and procedures for chamber production are described in detail. The results from the chamber quality control tests of the first 30 constructed chambers are reported.

47 OTHER INSTRUMENTATION↗

Preface to the Special Issue on Signal Processing, Data Acquisition and Front-end Systems for Radiation Detection and Measurements

This special issue of the Journal of Signal Processing Systems focuses on advancement of signal processing and data-acquisition for radiation detection and measurements. The seven articles included cover diverse topics within the scope of radiation detection ranging from understanding of fundamental fission process, instrumentation, and application of radiation interaction (e.g., tomography and imaging). The articles focus on signal processing for fission spectrometer, neutron and gamma-ray computed tomography and artificial intelligence methods, dynamic neutron imaging system, pulse-pileup correction in x-ray spectroscopy and calibration methods in radiation measurement.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Soft X-ray measurements of transport and MHD activity in the core and edge NSTX plasma (Final Technical Report)

A comprehensive suite of innovative diagnostic instrumentation and techniques has been developed by the Johns Hopkins collaboration for measurements of transport and MHD activity in the core and edge of the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Laboratory (PPPL). These include ultrafast multi-energy poloidal soft X-ray arrays, high spatial resolution multi-energy tangential soft X-ray arrays, high spectral resolution transmission grating imaging VUV spectrometers and ultrafast bolometric arrays, which measure over a broad range of spatial, spectral, and temporal scales the emission from ohmic, RF, and beam driven NSTX plasmas. The instrumentation was designed to fulfill the specific measurement needs of the Spherical Torus (ST) magnetic fusion concept and is accompanied by a comprehensive set of numerical tools for data analysis and modeling, aimed at determining as many as possible plasma parameters and at extracting as much as possible physics information from NSTX experiments. The Johns Hopkins diagnostics have been and continue to be instrumental for essentially all the NSTX experiments. In addition, our own research and experiments using these diagnostics has led over the years to fundamental conclusions for the ST fusion physics, such as the establishment of near neoclassical impurity transport in the NSTX core and edge plasma, and the critical role of the Global Alfven Eigenmode (GAE) MHD activity for the ST core electron thermal transport. The Johns Hopkins Diagnostics continue to be operational on the upgraded NSTX-U and will provide key plasma information in its upcoming high field, current and power experimental campaigns. The present report summarizes the main technical characteristics and measurement capabilities of the diagnostic instrumentation and methods developed within our research and describes a key physics result achieved during this research. Success in our research was made possible also by the excellent support and cooperation of the NSTX research team and of PPPL researchers, who are warmly acknowledged here.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dissociative electron attachment studies of gas-phase acetic acid using a velocity map imaging technique

Abstract Advancing instrumentation to explore dissociative electron attachment (DEA) studies allows previously unattainable information to be acquired. Using a newly constructed velocity map imaging spectrometer, we revisited a study on DEA to gas-phase acetic acid. We discuss possible fragmentation channels and compared the corresponding ion yields with previous high electron-energy resolution results. We focus on the channels occurring at higher energies, particularly near 10 eV, and calculate their thermodynamic thresholds. Moreover, we expand previous studies and perform time-sliced imaging near the 10 eV resonance to obtain the kinetic energy distribution of the fragment ions.

Optics↗

Advanced Instrumentation for Metal Additive Manufacturing

Laser powder bed fusion (LPBF) is the most widely used process for metal additive manufacturing (AM), particularly where complex geometries provide performance advantages unattainable with traditional manufacturing techniques. However, LPBF is highly sensitive to innate variability in both the powder spreading and fusion steps, often leading to defects such as pores that are difficult to detect yet significantly impair component mechanical properties and fatigue life. This thesis presents a range of novel instruments enabling both precise assessment of powder layer characteristics and in-situ thermal metrology of metal AM to advance the quality control of LPBF. First, leveraging a custom X-ray microscope and a radiation-transport model developed through this work, transmission X-ray imaging is used to study spreading of thin metal powder layers. Effective layer depth is directly mapped at a process-relevant size scale, surpassing optical techniques that can only estimate local deposition from layer surface topography. Layer packing density and quality are shown to be influenced by powder flowability and particle size relative to nominal powder layer thickness. Layer quality is additionally connected to the geometry of the spreading implement and its velocity. This technique and its presented findings enable pairing feedstocks with spreading strategies that create layers with consistent packing density and uniformity. Second, a twofold approach is employed to optically interrogate the laser fusion step of LPBF for observing signatures of defect formation. Aperture division multiplexing is conceptualized, providing for simultaneous laser delivery and high-fidelity infrared (IR) process monitoring through a common optic. In-situ microscopy at 50 μm spatial resolution and at mid-wave IR wavelengths is proven readily achievable with the first purpose-built optic of this type. Next, a bespoke imaging spectrometer, along with a temperature-emissivity separation technique, is used to retrieve accurate process temperatures over a 1000 K range. Data from these instruments are correlated to porosity as fine as 4.3 μm in two LPBF test artifacts, as verified using computed tomography (CT), establishing the viability of robust optically-based component qualification.

Penny, Ryan↗

A Replacement Cold Neutron Guide System for HFIR (Conceptual Design Report)

The design of a replacement cold neutron guide system for the High Flux Isotope Reactor (HFIR) is presented. The proposed six-channel design uses the latest technologies and is optimally designed to account for operational and site constraints. These include the design of the cold source and the beam tube, the size and shape of the penetrations in the reactor confinement boundary, and the shape and orientation of the guide hall. The existing user instruments are a macromolecular diffractometer (IMAGINE), an IMAGING station, two small-angle neutron scattering (SANS) instruments (Bio-SANS and GP-SANS), and a cold triple-axis spectrometer (C-TAX). These instruments will all be reinstalled at end-of-guide positions with improved performance, and a position for a new high-performance neutron spin echo instrument will be created. The proposed guide design requires an extension to the guide hall toward the south. The calculated flux gain for a typical experiment is between a factor of 1.3 and 3 for all instruments, with the exception of the C-TAX instrument, which stands to gain a factor of >30 in flux at the sample. The new guide system will also offer additional performance gains, such as an increase in Q-range on Bio-SANS. The stated performance gains do not take into account any potential performance gains resulting from renewal and realignment of the guide system. The design of the guide system in the common sections up to about 25 m from the source is considered to be complete and ready for engineering design, while the designs of the instrument-specific guides are in some cases still a work in progress. The present report describes the current status of those designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗