Search NASA⌕ Search

SEARCH · Search NASA

Results for “image understandings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Understanding reliability and some limitations of the images and spectra reconstructed from a multi-monochromatic x-ray imager

Temperature and density asymmetry diagnosis is critical to advance inertial confinement fusion (ICF) science. A multi-monochromatic x-ray imager (MMI) is an attractive diagnostic for this purpose. The MMI records the spectral signature from an ICF implosion core with time resolution, 2-D space resolution, and spectral resolution. While narrow-band images and 2-D space-resolved spectra from the MMI data constrain temperature and density spatial structure of the core, the accuracy of the images and spectra depends not only on the quality of the MMI data but also on the reliability of the post-processing tools. In this paper, we synthetically quantify the accuracy of images and spectra reconstructed from MMI data. Errors in the reconstructed images are less than a few percent when the space-resolution effect is applied to the modeled images. The errors in the reconstructed 2-D space-resolved spectra are also less than a few percent except those for the peripheral regions. Spectra reconstructed for the peripheral regions have slightly but systematically lower intensities by ~6% due to the instrumental spatial-resolution effects. However, this does not alter the relative line ratios and widths and thus does not affect the temperature and density diagnostics. We also investigate the impact of the pinhole size variation on the extracted images and spectra. A 10% pinhole size variation could introduce spatial bias to the images and spectra of ~10%. A correction algorithm is developed, and it successfully reduces the errors to a few percent. Finally, it is desirable to perform similar synthetic investigations to fully understand the reliability and limitations of each MMI application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging, understanding, and control of nanoscale materials transformations

The development of liquid cells for transmission electron microscopy has enabled breakthroughs in our ability to follow nanoscale structural, morphological, or chemical changes during materials growth and applications. Time-resolved high-resolution imaging and chemical analysis through liquids opened the opportunity to capture nanoscale dynamic processes of materials, including reaction intermediates and the transformation pathways. In this article, a series of work is highlighted with topics ranging from liquid cell developments to in situ studies of nanocrystal growth and transformations, dendrite formation, and suppression of lithium dendrites through in situ characterization of the solid–electrolyte interphase chemistry. The understanding garnered is expected to accelerate the discovery of novel materials for applications in energy storage, catalysis, sensors, and other functional devices.

36 MATERIALS SCIENCE↗

Understanding structure-processing relationships in metal additive manufacturing via featurization of microstructural images

Understanding and predicting accurate property-structure-processing relationships for additively manufactured components is important for both forward and inverse design of robust, reliable parts and assemblies. While direct mapping of process parameters to properties is sometimes plausible, it is often rendered difficult due to poor microstructural control. Exploring the direct relationship between processing conditions and microstructural features can thus provide significant physical insights and aid the overall design process. Here, in this study, we develop an automated high-throughput framework to simulate an uncertainty-aware additive manufacturing (AM) process, characterize microstructural images, and extract meaningful features/descriptors. A kinetic Monte Carlo (KMC) based model of the AM process is used to simulate microstructural evolution for a diverse set of experimentally relevant processing conditions. We perform a parametric study to explore the relationship between microstructural features and processing conditions. Our results indicate that a many-to-one mapping can exist between processing conditions and typical descriptors; therefore, multiple descriptors are thus necessary to unambiguously represent microstructural images. Our work provides crucial quantitative and qualitative in-formation that would aid in the selection of features for microstructural images. Featurized microstructures could then be utilized to build data-driven models for predictive control of microstructures and thereby properties of additively manufactured components.

36 MATERIALS SCIENCE↗

Computational modeling and neutron imaging to understand interface shape and solute segregation during the vertical gradient freeze growth of BaBrCl:Eu

In this work we apply continuum models to analyze phase change, heat transfer, fluid flow, solute transport, and segregation in order to understand prior neutron imaging observations of the vertical gradient freeze growth of Eu-doped BaBrCl. The models provide a rigorous framework in which to understand the mechanisms that are responsible for the complicated evolution of interface shape and dopant distribution in the growth experiment. We explain how a transition in the solid/liquid interface shape from concave to convex is driven by changes in radial heat transfer caused by furnace design. We also provide a mechanistic explanation of how dynamic growth conditions and changes of the flow structure in the melt result in complicated segregation patterns in this system. A growth pause caused by controller lock-up is shown to result in a band of solute depletion in accordance with classical theory. However, changing flow patterns during growth result in a non-monotonic axial distribution of solute that cannot be explained by simple application of classical segregation models. We assert that the approach presented here, namely the use of rigorous models in conjunction advanced diagnostics, such as neutron imaging, provides an exciting path forward for process optimization and control, accelerating the incremental advances that have, in the past, typically relied on empiricism, experience, and intuition.

36 MATERIALS SCIENCE↗

The VIBES Are Shifting: Assessing Emergent Capabilities in Multi-Modal Models

Researchers assessing open-source domains such as the internet, and particularly those studying information conflict, often have no single prescribed workflow. In the course of their research, they may need to perform a diverse array of tasks far beyond simply identifying an ever-changing set of objects. These analytical tasks can include ascertaining the provenance of images, understand an image in the context of accompanying text-based data, or identifying indicators of digital image manipulation. They must further be able to do this at the scale of tens of thousands of images or more. Traditional machine vision models have typically lacked the flexibility and breadth of performance sufficient for these needs. The research team from Pacific Northwest National Laboratory assessed the performance of a single baseline CLIP ViT-L model against a series of analytical tasks relevant for the study of online information conflict.

97 MATHEMATICS AND COMPUTING↗

Fill Factor Loss in Fielded Photovoltaic Modules Due to Metallization Failures, Characterized by Luminescence and Thermal Imaging

Understanding the causes of photovoltaic module failure in the field can be achieved using spatially-resolved imaging tools in combination with current-voltage (IV) characterization. We evaluate 23 field-degraded modules by comparing their IV characteristics with module images obtained by electroluminescence, photoluminescence, UV-fluorescence, and dark lock-in thermography. We identify primarily metallization failures (metallization series resistance, solder point heating, broken fingers, disrupted interconnects) in these modules that has led to a severe drop in the fill factor and up to 35% power loss over only 2 years of deployment.

14 SOLAR ENERGY↗

Space charge effects in ultrafast electron diffraction and imaging

Understanding space charge effects is central for the development of high-brightness ultrafast electron diffraction and microscopy techniques for imaging material transformation with atomic scale detail at the fs to ps timescales. We present methods and results for direct ultrafast photoelectron beam characterization employing a shadow projection imaging technique to investigate the generation of ultrafast, non-uniform, intense photoelectron pulses in a dc photo-gun geometry. Combined with N-particle simulations and an analytical Gaussian model, we elucidate three essential space-charge-led features: the pulse lengthening following a power-law scaling, the broadening of the initial energy distribution, and the virtual cathode threshold. The impacts of these space charge effects on the performance of the next generation high-brightness ultrafast electron diffraction and imaging systems are evaluated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterizing high energy spectra of NIF ignition hohlraums using a differentially filtered high energy multi-pinhole X-ray imager

Understanding hot electron distributions generated inside hohlraums is important to the ignition campaign for controlling implosion symmetry and sources of preheat. While direct imaging of hot electrons is difficult, their spatial distribution and spectrum can be deduced by detecting high energy x-rays generated as they interact with the target materials. We used an array of 18 pinholes, with four independent filter combinations, to image entire hohlraums with a magnification of 0.87x during the hohlraum energetics campaign on NIF. Comparing our results with hohlraum simulations indicates that the characteristic 30 keV hot electrons are mainly generated from backscattered laser plasma interactions rather than from hohlraum hydrodynamics.

42 ENGINEERING↗

Characterizing high energy spectra of NIF ignition Hohlraums using a differentially filtered high energy multipinhole x-ray imager

Understanding hot electron distributions generated inside Hohlraums is important to the national ignition campaign for controlling implosion symmetry and sources of preheat. While direct imaging of hot electrons is difficult, their spatial distribution and spectrum can be deduced by detecting high energy x-rays generated as they interact with target materials. We used an array of 18 pinholes with four independent filter combinations to image entire Hohlraums with a magnification of 0.87x during the Hohlraum energetics campaign on NIF. Comparing our results with Hohlraum simulations indicates that the characteristic 10-40 keV hot electrons are mainly generated from backscattered laser-plasma interactions rather than from Hohlraum hydrodynamics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic compaction of nickel powder examined by x-ray phase contrast imaging

Understanding the shock response of porous, granular materials is important for many scientific applications. In this work, a propagation-based x-ray phase contrast imaging technique was used to examine the shock compaction response of Ni powder (particle size: 30 and 45 µm), encapsulated in PMMA cylinders, in situ and in real time. The propagating shock wave in the PMMA cylinder and the deformation of the Ni powder column were recorded, but the compaction wave in the Ni powder could not be observed due to insufficient penetration of x-ray photons through the sample. The overall shape of the deformed Ni column downstream of the PMMA shock looked qualitatively similar for both particle sizes: it deformed inward and then outward similar to a converging-diverging nozzle, followed by a ‘mushroom’-like structure at the impact face. A preliminary analysis of our data using shock-polar method provided insight into the observed shock and flow deflection angles at the PMMA/Ni interface, and permitted evaluation of the Ni powder EOS used in this work.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantifying particle-scale 3D granular dynamics during rapid compaction from time-resolved in situ 2D x-ray images

Understanding the particle-scale dynamics of granular materials during rapid compaction and flow is of fundamental importance for manufacturing, planetary science, geology, and defense applications. Time-resolved 2D radiography and static 3D x-ray tomography are powerful in situ tools for studying particle-scale dynamics but provide detail only in 2D or with significant time-scale limitations, respectively. Here, we introduce a new method that uses 2D in situ x-ray imaging for determining time-resolved 3D particle-scale dynamics in rapidly compressed granular materials. The method employs initial particle packing structures obtained from x-ray tomography, a 2D x-ray image generation algorithm, and an optimization algorithm. We first describe and validate the method using finite element simulations. Furthermore, we then apply the technique to x-ray phase-contrast images obtained during rapid compaction of granular materials with varying particle morphology and sample thickness. The depth-resolved particle-scale dynamics reveal complex velocity and porosity fields evolving heterogeneously along and perpendicular to the compaction direction. We characterize these features, their fluctuations near the compaction front, and the compaction front thickness. Our technique can be applied to understanding granular dynamics during rapid compaction events, and rearrangements during slower, but non-quasi-static, flows.

36 MATERIALS SCIENCE↗

NaroNet: Discovery of tumor microenvironment elements from highly multiplexed images

Understanding the spatial interactions between the elements of the tumor microenvironment -i.e. tumor cells. fibroblasts, immune cells- and how these interactions relate to the diagnosis or prognosis of a tumor is one of the goals of computational pathology. We present NaroNet, a deep learning framework that models the multi-scale tumor microenvironment from multiplex-stained cancer tissue images and provides patient-level interpretable predictions using a seamless end-to-end learning pipeline. Trained only with multiplex-stained tissue images and their corresponding patient-level clinical labels, NaroNet unsupervisedly learns which cell phenotypes, cell neighborhoods, and neighborhood interactions have the highest influence to predict the correct label. To this end, NaroNet incorporates several novel and state-of-the-art deep learning techniques, such as patch-level contrastive learning, multi-level graph embeddings, a novel max-sum pooling operation, or a metric that quantifies the relevance that each microenvironment element has in the individual predictions. We validate NaroNet using synthetic data simulating multiplex-immunostained images where a patient label is artificially associated to the -adjustable- probabilistic incidence of different microenvironment elements. We then apply our model to two sets of images of human cancer tissues: 336 seven-color multiplex-immunostained images from 12 high-grade endometrial cancer patients; and 382 35-plex mass cytometry images from 215 breast cancer patients. In both synthetic and real datasets, NaroNet provides outstanding predictions of relevant clinical information while associating those predictions to the presence of specific microenvironment elements.

60 APPLIED LIFE SCIENCES↗

Spontaneous imbibition of water and determination of effective contact angles in the Eagle Ford Shale Formation using neutron imaging

Understanding of fundamental processes and prediction of optimal parameters during the horizontal drilling and hydraulic fracturing process results in economically effective improvement of oil and natural gas extraction. Although, the modern analytical and computational models can capture fracture growth, there is a lack of experimental data on spontaneous imbibition and wettability in oil and gas reservoirs for the validation of further model development. In this work, we used neutron imaging to measure the spontaneous imbibition of water into fractures of Eagle Ford Shale with known geometries and fracture orientations. An analytical solution for a set of nonlinear second-order differential equations was applied to the measured imbibition data to determine effective contact angles. The analytical solution fit the measured imbibition data reasonably well and determined effective contact angles were slightly higher than static contact angles due to effects of in-situ changes in velocity, surface roughness, and heterogeneity of mineral surfaces on the fracture surface. Additionally, small fracture widths may have retarded imbibition and affected model fits, which suggests that average fracture widths are not satisfactory for modeling imbibition in natural systems.

DiStefano, Victoria H. (ORCID:0000000160239716)↗

New perspectives on materials and device dynamics using time-resolved full-field diffraction X-ray imaging

Understanding how materials evolve during synthesis, processing, or device operation requires experimental access to structural dynamics across wide ranges of length and time scales, often in bulk samples or even within packaged devices. Time-resolved full-field diffraction X-ray microscopy has recently emerged as a powerful way to meet this need by combining the penetration and structural sensitivity of X-ray diffraction with objective-lens-based magnification, sensitive high-resolution X-ray imaging detectors, and pump-probe and real-time imaging strategies. Advances in full-field X-ray diffraction microscopy, often termed dark-field X-ray microscopy (DFXM), enable simultaneous imaging of extended fields of view while retaining crystallographic selectivity. Time-resolved DFXM promises to enable advances in materials processing and dynamics, electrochemical and photochemical processes, and the design of electronic devices. This Perspective summarizes the key instrumental concepts that define the performance of these methods, including the choice of imaging optics, detector considerations, and the impact of source time structure at synchrotron light sources and X-ray free-electron lasers (XFELs). We discuss the simultaneous use of complementary imaging modes that are increasingly used in practice. The early demonstrations of the potential of time-resolved DFXM include real-time defect and grain-boundary dynamics during metal annealing, stroboscopic imaging of functional devices with high strain sensitivity, and ultrafast pump-probe implementations at XFELs that directly visualize acoustic-wave propagation and energy dissipation in bulk crystals.

Dark-field X-ray microscopy↗

Temperature-Dependent Morphological Evolution during Corrosion of the Ni-20Cr Alloy in Molten Salt Revealed by Multiscale Imaging

Understanding the mechanisms leading to the degradation of alloys in molten salts at elevated temperatures is significant for developing several key energy generation and storage technologies, including concentrated solar and next-generation nuclear power plants. Specifically, the fundamental mechanisms of different types of corrosion leading to various morphological evolution characteristics for changing reaction conditions between the molten salt and alloy remain unclear. Here, in this work, the three-dimensional (3D) morphological evolution of Ni–20Cr in KCl–MgCl 2 is studied at 600 °C by combining in situ synchrotron X-ray and electron microscopy techniques. By further comparing different morphology evolution characteristics in the temperature range of 500–800 °C, the relative rates between diffusion and reaction at the salt–metal interface lead to different morphological evolution pathways, including intergranular corrosion and percolation dealloying. In this work, the temperature-dependent mechanisms of the interactions between metals and molten salts are discussed, providing insights for predicting molten salt corrosion in real-world applications.

36 MATERIALS SCIENCE↗

Feature Extraction and Selection From the Perspective of Explosive Detection

Features are extractable measurements from a sample image summarizing the information content in an image and in the process providing an essential tool in image understanding. In particular, they are useful for image classification into pre-defined classes or grouping a set of image samples (also called clustering) into clusters with similar within-cluster characteristics as defined by such features. At the lowest level, features may be the intensity levels of a pixel in an image. The intensity levels of the pixels in an image may be derived from a variety of sources. For example, it can be the temperature measurement (using an infra-red camera) of the area representing the pixel or the X-ray attenuation in a given volume element of a 3-d image or it may even represent the dielectric differential in a given volume element obtained from an MIR image. At a higher level, geometric descriptors of objects of interest in a scene may also be considered as features in the image. Examples of such features are: area, perimeter, aspect ratio and other shape features, or topological features like the number of connected components, the Euler number (the number of connected components less the number of 'holes'), etc. Occupying an intermediate level in the feature hierarchy are texture features which are typically derived from a group of pixels often in a suitably defined neighborhood of a pixel. These texture features are useful not only in classification but also in the segmentation of an image into different objects/regions of interest. At the present state of our investigation, we are engaged in the task of finding a set of features associated with an object under inspection ( typically a piece of luggage or a brief case) that will enable us to detect and characterize an explosive inside, when present. Our tool of inspection is an X-Ray device with provisions for computed tomography (CT) that generate one or more (depending on the number of energy levels used) digitized 3-dimensional attenuation images with a voxel resolution of the order of one quarter of a milimeter. In the task of feature extraction and subsequent selection of an appropriate subset thereof, several important factors need to be considered. Foremost among them are: (1) Definition of the sampling unit from which the features will be extracted for the purpose of detection/ identification of the explosives. (2) The choice of features ( given the sampling unit) to be extracted that can be used to signal the existence / identity of the explosive. (3) Robustness of the computed features under different inspection conditions. To attain robustness, invariance under the transformations of translation, scaling, rotation and change of orientation is highly desirable. (4) The computational costs in the process of feature extraction, selection and their use in explosive detection/ identification In the search for extractable features, we have done a thorough literature survey with the above factors in mind and come out with a list of features that could possibly help us in meeting our objective. We are assuming that features will be based on sampling units that are single CT slices of the target. This may however change when appropriate modifications should be made to the feature extraction process. We indicate below some of the major types of features in 2- or 3-dimensional images that have been used in the literature on application of pattern recognition (PR) techniques in image understanding and are possibly pertinent to our study. In the following paragraph, we briefly indicate the motivation that guided us in the choice of these features, and identify the nature of the constraints. The principal feature types derivable from an image will be discussed in section 2. Once the features are extracted, one must select a subset of this feature set that will retain the most useful information and remove any redundant and irrelevant information that may have a detrimental effect on the classifier performance. This is discussed in section 3. Section 4 provides a brief summary.

42 ENGINEERING↗

Linking Transient Voltage to Spatially-Resolved Luminescence Imaging to Understand Reliability of Perovskite Photovoltaics

In this work, we present a methodology to separate effects of perovskite device metastability from irreversible degradation, using stress/rest cycling under constant current bias while collecting a series of electroluminescence images and continuously monitoring voltage. We develop a simulation model and procedures for image processing to better understand the effects of ion parameters on the transient nature of voltage and evolving electroluminescence images.

electroluminescence↗