Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Simulation of image detectors in radiology for determination of scatter-to-primary ratios using Monte Carlo radiation transport code MCNP/MCNPX

Purpose: The purpose of this study was to compare and validate three methods to simulate radiographic image detectors with the Monte Carlo software MCNP/MCNPX in a time efficient way. Methods: The first detector model was the standard semideterministic radiography tally, which has been used in previous image simulation studies. Next to the radiography tally two alternative stochastic detector models were developed: A perfect energy integrating detector and a detector based on the energy absorbed in the detector material. Validation of three image detector models was performed by comparing calculated scatter-to-primary ratios (SPRs) with the published and experimentally acquired SPR values. Results: For mammographic applications, SPRs computed with the radiography tally were up to 44% larger than the published results, while the SPRs computed with the perfect energy integrating detectors and the blur-free absorbed energy detector model were, on the average, 0.3% (ranging from -3% to 3%) and 0.4% (ranging from -5% to 5%) lower, respectively. For general radiography applications, the radiography tally overestimated the measured SPR by as much as 46%. The SPRs calculated with the perfect energy integrating detectors were, on the average, 4.7% (ranging from -5.3% to -4%) lower than the measured SPRs, whereas for the blur-free absorbed energy detector model, the calculated SPRs were, on the average, 1.3% (ranging from -0.1% to 2.4%) larger than the measured SPRs. Conclusions: For mammographic applications, both the perfect energy integrating detector model and the blur-free energy absorbing detector model can be used to simulate image detectors, whereas for conventional x-ray imaging using higher energies, the blur-free energy absorbing detector model is the most appropriate image detector model. The radiography tally overestimates the scattered part and should therefore not be used to simulate radiographic image detectors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observing cosmic-ray extensive air showers with a silicon imaging detector

Extensive air showers induced from high-energy cosmic rays provide a window into understanding the most energetic phenomena in the universe. We present a new method for observing these showers using the silicon imaging detector Subaru Hyper Suprime-Cam (HSC). This method has the advantage of being able to measure individual secondary particles. When paired with a surface detector array, silicon imaging detectors like Subaru HSC will be useful for studying the properties of extensive air showers in detail. The following report outlines the first results of observing extensive air showers with Subaru HSC. The potential for reconstructing the incident direction of primary cosmic rays is demonstrated and possible interdisciplinary applications are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

The iQID Camera: An Ionizing-Radiation Quantum Imaging Detector

We have developed and tested a novel, ionizing-radiation Quantum Imaging Detector (iQID). This scintillation-based detector was originally developed as a high-resolution gamma-ray imager, called BazookaSPECT, for use in single-photon emission computed tomography (SPECT). Recently, we have investigated the detectors response and imaging potential with other forms of ionizing radiation including alpha, neutron, beta, and fission fragment particles. The detector’s response to a broad range of ionizing radiation has prompted its new title. The principle operation of the iQID camera involves coupling a scintillator to an image intensifier. The scintillation light generated particle interactions is optically amplified by the intensifier and then re-imaged onto a CCD/CMOS camera sensor. The intensifier provides sufficient optical gain that practically any CCD/CMOS camera can be used to image ionizing radiation. Individual particles are identified and their spatial position (to sub-pixel accuracy) and energy are estimated on an event-by-event basis in real time using image analysis algorithms on high-performance graphics processing hardware. Distinguishing features of the iQID camera include portability, large active areas, high sensitivity, and high spatial resolution (tens of microns). Although modest, iQID has energy resolution that is sufficient to discrimate between particles. Additionally, spatial features of individual events can be used for particle discrimination. An important iQID imaging application that has recently been developed is single-particle, real-time digital autoradiography. In conclusion, we present the latest results and discuss potential applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-51: Quantitative Assessment of X-Ray Imaging Detector Performance in a Clinical Setting - a Simple Approach Using a Commercial Instrument

Purpose: To measure and compare the performance of X-ray imaging detectors in a clinical setting using a dedicated instrument for the quantitative determination of detector performance. Methods: The DQEPro (DQE Instruments Inc., London, Ontario Canada) was used to determine the MTF, NPS and DQE using an IEC compliant methodology for three different imaging modalities: conventional radiography (CsI-based detector), general-purpose radioscopy (CsI-based detector), and mammography (a-Se based detector). The radiation qualities (IEC) RQA-5 and RQA-M-2 were used for the CsI-based and a-Se-based detectors, respectively. The DQEPro alleviates some of the difficulties associated with DQE measurements by automatically positioning test devices over the detector, guiding the user through the image acquisition process and providing software for calculations. Results: A comparison of the NPS showed that the image noise of the a-Se detector was less correlated than the CsI detectors. A consistently higher performance was observed for the a-Se detector at all spatial frequencies (MTF: 0.97@0.25 cy/mm, DQE: 0.72@0.25 cy/mm) and the DQE drops off slower than for the CsI detectors. The CsI detector used for conventional radiography displayed a higher performance at low spatial frequencies compared to the CsI detector used for radioscopy (DQE: 0.65 vs 0.60@0.25 cy/mm). However, at spatial frequencies above 1.3 cy/mm, the radioscopy detector displayed better performance than the conventional radiography detector (DQE: 0.35 vs 0.24@2.00 cy/mm). Conclusion: The difference in the MTF, NPS and DQE that was observed for the two different CsI detectors and the a-Se detector reflect the imaging tasks that the different detector types are intended for. The DQEPro has made the determination and calculation of quantitative metrics of X-ray imaging detector performance substantially more convenient and accessible to undertake in a clinical setting.

60 APPLIED LIFE SCIENCES↗

Development of a cold-neutron imaging detector based on thick gaseous electron multiplier

We present the results of our recent studies on a cold-neutron imaging detector prototype based on THick Gaseous Electron Multiplier (THGEM). The detector consists of a thin Boron layer, for neutron-to-charged particle conversion, coupled to two THGEM electrodes in cascade for charge amplification and a position-sensitive charge-readout anode. The detector operates in Ne/(5%)CF{sub 4}, at atmospheric pressure, in a stable condition at a gain of around 10{sup 4}. Due to the geometrical structure of the detector elements (THGEM geometry and charge read-out anode), the image of detector active area shows a large inhomogeneity, corrected using a dedicated flat-filed correction algorithm. The prototype provides a detection efficiency of 5% and an effective spatial resolution of the order of 1.3 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty identification in mass estimation applications with imaging detectors

Mass quantification using standoff gamma imaging techniques is a boon to the special nuclear material holdup monitoring community, but before the method is deemed acceptable as a replacement for historical gamma detection-based methods, there are several considerable sources of uncertainty that must be addressed. These uncertainty sources have received sparse coverage in the literature, but provide the bulk of the uncertainty estimated in practice outside of standard counting statistics. For imaging, there is a fundamental difference between detection/localization and mass estimation operating modalities, where detection/localization can tolerate significantly larger uncertainty because the goal is detection of a distant source, rather than the quantification of that source. Historically, quantification requires a known geometry between source and detector, as well as a calibrated efficiency correction curve, which is well suited to laboratory practice for a stationary detector; however, this requires some corrections and assumptions (e.g., generalized geometry) for field applications, since additional degrees of freedom are present in the source-to-detector position, intervening materials, and non-uniform source distributions, when compared against the laboratory case. Use of an imaging detector during holdup measurements would address these issues by calculating the spatial geometry of the distant source as seen by the detector, with efficiency corrected according to the source-to-detector angle. While this aim promises a better estimation accuracy than generalized geometry assumptions, additional uncertainties are added from the imaging mechanism itself. Of these uncertainties, some are readily mitigated and methods to do so are included in the discussion, while some uncertainties are specific to the imaging class of instruments and are investigated and discussed in detail. Uncertainties are categorized into two general areas: instrument design and algorithmic. Instrument design-based uncertainties include basic detector characteristics for timing and energy resolution, handling of list mode data for coincidence detection, and geometric layout of and propagation of spatial uncertainty into imaging uncertainty. Algorithmic-based uncertainties discussed herein pertain to image reconstruction, the weight assignment problem from cone interactions, and the effects of spatial discretization on mass estimation. With these major sources of uncertainty identified, the path towards acceptance of imaging as a holdup monitoring method becomes clearer.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-H-CAMPUS-IeP1-01: Bias and Computational Efficiency of Variance Reduction Methods for the Monte Carlo Simulation of Imaging Detectors

Purpose: Variance reduction techniques (VRTs) are employed in Monte Carlo simulations to obtain estimates with reduced statistical uncertainty for a given simulation time. In this work, we study the bias and efficiency of a VRT for estimating the response of imaging detectors. Methods: We implemented Directed Sampling (DS), preferentially directing a fraction of emitted optical photons directly towards the detector by altering the isotropic model. The weight of each optical photon is appropriately modified to maintain simulation estimates unbiased. We use a Monte Carlo tool called fastDETECT2 (part of the hybridMANTIS open-source package) for optical transport, modified for VRT. The weight of each photon is calculated as the ratio of original probability (no VRT) and the new probability for a particular direction. For our analysis of bias and efficiency, we use pulse height spectra, point response functions, and Swank factors. We obtain results for a variety of cases including analog (no VRT, isotropic distribution), and DS with 0.2 and 0.8 optical photons directed towards the sensor plane. We used 10,000, 25-keV primaries. Results: The Swank factor for all cases in our simplified model converged fast (within the first 100 primaries) to a stable value of 0.9. The root mean square error per pixel for DS VRT for the point response function between analog and VRT cases was approximately 5e-4. Conclusion: Our preliminary results suggest that DS VRT does not affect the estimate of the mean for the Swank factor. Our findings indicate that it may be possible to design VRTs for imaging detector simulations to increase computational efficiency without introducing bias.

60 APPLIED LIFE SCIENCES↗

Thermal neutron imaging detector with wavelength shifting fiber and digital readout

Here, we developed a large area, digital thermal neutron imaging detector. The detector uses a 6 LiF/ZnS(Ag) neutron-sensitive scintillator combined with wavelength shifting fiber technology. The signals from fiber channels are amplified, integrated, and digitized using individual analog-to-digital converters for each channel. The neutron position is determined from the digitized signal using a least-squares gaussian-fitting algorithm. The detector size was 77 × 38 cm 2 (2926 cm 2 ), it provided 1.3 mm resolution, and its resolution can further be improved. The detector was designed for a powder diffraction neutron scattering beamline and provided substantial improvement of d-space resolution compared with existing detectors. This detector may have broader applications due to its large area and high spatial resolution extended over its large area.

6LiF/ZnS(Ag) scintillator↗

SU-E-I-29: Generalized Relative Object Detectability (G-ROD): A Metric for Comparing X-Ray Imaging Detector Systems

Purpose: To determine the relative task-specific performance of two x-ray imaging detectors including the effect of other components of the imaging chain. Methods: The relative object detectability (ROD) was defined as the ratio of the integral of the detective-quantum efficiency (DQE) of a detector weighted by the square of the Fourier Transform (or frequency spectrum) of the object to the same integral for a second detector. The generalized ROD (G-ROD) is calculated by replacing DQE by the generalized DQE (GDQE) which includes geometric unsharpness and scatter to evaluate the total imaging chain. The G-ROD was calculated for the micro-angiographic fluoroscope (MAF) relative to a flat-panel detector (FPD) for low (1.05) and high (1.2) magnifications with two focal-spot sizes, small (0.3 mm) and medium (0.5 mm), and for the same value of scatter fraction. Solid spheres from 50 to 600 microns were simulated as the objects for this evaluation. The G-ROD results were compared with those of the ROD which considers the detectors alone. Results: For 50-micron spheres, the ROD is 7.93 and, for the small [medium] focus, the G-ROD is 6.74 [5.22] at low magnification and 3.03 [1.66] at high magnification, indicating superior performance of the MAF particularly at low magnification. Both ROD and G-ROD decrease monotonically with size and remain around one above 400-microns. The G-ROD decreases more dramatically with low compared to high magnification for both focal spots. Conclusion: In all cases, the MAF performs better than the FPD and the decreasing trend of the G-ROD indicates that the performance of both detectors becomes similar as the object size increases and becomes nearly equal above 400-micron diameter sphere size. Finally, increased magnification and focal-spot size decrease the G-ROD, indicting that they degrade the performance of the MAF more than that of the FPD for a small-object viewing task. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

60 APPLIED LIFE SCIENCES↗

Energy-sensitive imaging detector applied to the dissociative recombination of D{sub 2}H{sup +}

We report on an energy-sensitive imaging detector for studying the fragmentation of polyatomic molecules in the dissociative recombination of fast molecular ions with electrons. The system is based on a large area (10x10 cm{sup 2}) position-sensitive, double-sided Si-strip detector with 128 horizontal and 128 vertical strips, whose pulse height information is read out individually. The setup allows us to uniquely identify fragment masses and is thus capable of measuring branching ratios between different fragmentation channels, kinetic energy releases, and breakup geometries as a function of the relative ion-electron energy. The properties of the detection system, which has been installed at the Test Storage Ring (TSR) facility of the Max-Planck Institute for Nuclear Physics in Heidelberg, is illustrated by an investigation of the dissociative recombination of the deuterated triatomic hydrogen cation D{sub 2}H{sup +}. A huge isotope effect is observed when comparing the relative branching ratio between the D{sub 2} + H and the HD + D channel; the ratio 2B(D{sub 2} + H)/B(HD + D), which is measured to be 1.27{+-}0.05 at relative electron-ion energies around 0 eV, is found to increase to 3.7{+-}0.5 at {approx}5 eV.

74 ATOMIC AND MOLECULAR PHYSICS↗