Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optical Diagnostic Imaging of Multi-Rocket Plume-Induced Base Flow Environments

Non-intrusive optical diagnostic imaging was used for the first time to visualize multi-rocket plume-induced reacting base flows to simulate launch vehicle ascent from sea-level to 250,000 ft. In particular, planar laser induced florescence (PLIF) and infrared (IR) imaging were implemented for the first time to visualize and quantify base flow and rocket plume environments from sub-scale, short-duration propulsion models within a shock tunnel facility. This report discusses the successful imaging diagnostic methods for capturing base flow features and dynamics as a function of altitude. Important base flow and plume features were captured with PLIF and IR diagnostics to develop a conceptual base flow physics model. This imaging data specifically provides insight into the Space Launch System vehicle core-stage and Exploration Upper Stage base environments and further validates short-duration ground test techniques and computational modeling.

Mehta, Manish↗

Autonomous Diagnostic Imaging Performed by Untrained Operators using Augmented Reality as a Form of "Just-in-Time" Training

We will address the Human Factors and Performance Team, "Risk of performance errors due to training deficiencies" by improving the JIT training materials for ultrasound and OCT imaging by providing advanced guidance in a detailed, timely, and user-friendly manner. Specifically, we will (1) develop an audio-visual tutorial using AR that guides non-experts through an abdominal trauma ultrasound protocol; (2) develop an audio-visual tutorial using AR to guide an untrained operator through the acquisition of OCT images; (3) evaluate the quality of abdominal ultrasound and OCT images acquired by untrained operators using AR guidance compared to images acquired using traditional JIT techniques (laptop-based training conducted before image acquisition); and (4) compare the time required to complete imaging studies using AR tutorials with images acquired using current JIT practices to identify areas for time efficiency improvements. Two groups of subjects will be recruited to participate in this study. Operator-subjects, without previous experience in ultrasound or OCT, will be asked to perform both procedures using either the JIT training with AR technology or the traditional JIT training via laptop. Images acquired by inexperienced operator-subjects will be scored by experts in that imaging modality for diagnostic and research quality; experts will be blinded to the form of JIT used to acquire the images. Operator-subjects also will be asked to submit feedback to improve the training modules used during the scans to improve future training modules. Scanned-subjects will be a small group individuals from whom all images will be acquired.

Martin, D. S.↗

Autonomous Diagnostic Imaging Performed by Untrained Operator Using Augmented Reality as a Form of "Just-in-Time" Training

We will address the Human Factors and Performance Team, "Risk of performance errors due to training deficiencies" by improving the JIT training materials for ultrasound and OCT imaging by providing advanced guidance in a detailed, timely, and user-friendly manner. Specifically, we will (1) develop an audio-visual tutorial using AR that guides non-experts through an abdominal trauma ultrasound protocol; (2) develop an audio-visual tutorial using AR to guide an untrained operator through the acquisition of OCT images; (3) evaluate the quality of abdominal ultrasound and OCT images acquired by untrained operators using AR guidance compared to images acquired using traditional JIT techniques (laptop-based training conducted before image acquisition); and (4) compare the time required to complete imaging studies using AR tutorials with images acquired using current JIT practices to identify areas for time efficiency improvements. Two groups of subjects will be recruited to participate in this study. Operator-subjects, without previous experience in ultrasound or OCT, will be asked to perform both procedures using either the JIT training with AR technology or the traditional JIT training via laptop. Images acquired by inexperienced operator-subjects will be scored by experts in that imaging modality for diagnostic and research quality; experts will be blinded to the form of JIT used to acquire the images. Operator-subjects also will be asked to submit feedback to improve the training modules used during the scans to improve future training modules. Scanned-subjects will be a small group individuals from whom all images will be acquired.

Martin, David S.↗

Diagnostic Imaging in the Medical Support of the Future Missions to the Moon

This viewgraph presentation is a course that reviews the diagnostic imaging techniques available for medical support on the future moon missions. The educational objectives of the course are to: 1) Update the audience on the curreultrasound imaging in space flight; 2) Discuss the unique aspects of conducting ultrasound imaging on ISS, interplanetary transit, ultrasound imaging on ISS, interplanetary transit, and lunar surface operations; and 3) Review preliminary data obtained in simulations of medical imaging in lunar surface operations.

Sargsyan, Ashot E.↗

Diagnostic imaging applications; Proceedings of the Meeting, Amsterdam, Netherlands, October 8, 9, 1984

It is more important than ever that engineers have an understanding of the future needs of clinical and research medicine, and that physicians know somthing about probable future developments in instrumentation capabilities. Only by maintaining such a dialog can the most effective application of technological advances to medicine be achieved. This workshop attempted to provide this kind of information transfer in the limited field of diagnostic imaging. Biomedical research at the Jet Propulsion Laboratory is discussed, taking into account imaging results from space exploration missions, as well as biomedical research tasks based in these technologies. Attention is also given to current and future indications for magnetic resonance in medicine, high speed quantitative digital microscopy, computer processing of radiographic images, computed tomography and its modern applications, position emission tomography, and developments related to medical ultrasound.

Beckenbach, E. S.↗

Characterizing core and edge turbulence regimes with fluctuation imaging diagnostics in Wendelstein 7-X

Two density fluctuation imaging systems, phase contrast imaging (PCI) and gas puff imaging (GPI) measure spatially resolved density fluctuations with high time resolution throughout the core plasma (PCI) and in the scrape-off layer (GPI) of the Wendelstein 7-X (W7-X) stellarator. Both systems combined give a comprehensive overview of overall fluctuation levels, spectral properties such as their distribution in frequency and wavenumber space as well as their spatial distribution. These tools are used to assess changes in density turbulence in three representative discharges that transition into stable divertor detachment by different strategies (impurity seeding, density ramping and power starvation). Several general trends are identified when the radiated power fraction is systematically increased: In the plasma edge, the line emission observed by GPI shifts radially inward with a drop in electron temperature, and normalized intensity fluctuation profiles follow this inward shift. Skewness and kurtosis of these edge fluctuations are reduced, indicating a reduction of large intermittent transport events, and poloidal phase velocities decrease in magnitude. These observations are consistent with a reduced power input into the plasma edge and a general reduction of turbulent activity. Core density fluctuation levels remain nearly constant in the impurity seeding scenario, indicating that detachment does not significantly impact turbulence there. However, a strong reduction in the dominant outboard fluctuation phase velocity is observed that deviates from the previous interpretation of neoclassical radial electric field changes, showing that the core plasma is not completely unaffected. In the density ramp and power starvation scenarios, undesirable and irregular large-scale events arise clearly in both diagnostic systems as the radiative fraction is increased. Impurity seeding therefore seems to be a promising strategy on W7-X to achieve detachment without significantly altering core turbulence, especially when targeting a specific operating point in core density and heating power.

Wendelstein 7-X↗

Experimental investigation of H-mode pedestal turbulence using a charge exchange imaging diagnostic system at DIII-D

Microtearing modes (MTMs) (ω ~ ω de k θ ρ s ~ 0.1, k r ρ s ~ 0.3 – 1.0) are predicted to cause substantial electron thermal transport in the H-mode pedestal, limiting fusion performance on high-power devices. Localized 2D measurements of low-to-intermediate wavenumber density fluctuations in the edge of DIII-D H-mode plasmas suggest the presence of temporally intermittent or ‘bursting’ MTMs during the inter-ELM cycle in the steep gradient region. These measurements are obtained using a new intermediate radial resolution multichannel Charge eXchange Imaging (CXI) diagnostic that analyzes the intensity of the CVI emission at 529 nm. The mode is peaked near ρ = 0.97 with a radial full-width half maximum of 1.5–2.0 cm and a normalized density fluctuation amplitude peak of $\frac{dn_C}{n_C}$ ~ 5%, peaking near 60 kHz in the lab frame. The mode additionally features a broad spectral width from 30 to 180 kHz and propagates in the electron diamagnetic direction in the plasma frame. CXI measurements taken during discharges with high density and current ramps provide evidence that MTMs become unstable at finite collisionality and remain at nearly the same location in ρ-space despite scanning of rational surface position. This indicates that the location of the peak in the electron diamagnetic frequency is a stronger driving force than individual rational surfaces.

DIII-D↗

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION↗

Hierarchical Segmentation Enhances Diagnostic Imaging

Bartron Medical Imaging LLC (BMI), of New Haven, Connecticut, gained a nonexclusive license from Goddard Space Flight Center to use the RHSEG software in medical imaging. To manage image data, BMI then licensed two pattern-matching software programs from NASA's Jet Propulsion Laboratory that were used in image analysis and three data-mining and edge-detection programs from Kennedy Space Center. More recently, BMI made NASA history by being the first company to partner with the Space Agency through a Cooperative Research and Development Agreement to develop a 3-D version of RHSEG. With U.S. Food and Drug Administration clearance, BMI will sell its Med-Seg imaging system with the 2-D version of the RHSEG software to analyze medical imagery from CAT and PET scans, MRI, ultrasound, digitized X-rays, digitized mammographies, dental X-rays, soft tissue analyses, moving object analyses, and soft-tissue slides such as Pap smears for the diagnoses and management of diseases. Extending the software's capabilities to three dimensions will eventually enable production of pixel-level views of a tumor or lesion, early identification of plaque build-up in arteries, and identification of density levels of microcalcification in mammographies.

Source record↗

Advanced Diagnostics for Megahertz Imaging of Mixing, Fuel Spray, and Combustion Processes for Rotating Detonation Combustors

Recent advancements in megahertz rate, high-power, burst-mode laser technology are leveraged to perform and explore imaging measurements that spatially and temporally resolve the mixing, combustion, and detonation flow field in two laboratory-scale rotating detonation combustors (RDCs). In a non-premixed annular RDC, multiple imaging diagnostics are explored to investigate gaseous and liquid injector behavior, the detonation wave structure, and the propellant refill. In one instance, OH planar laser-induced fluorescence (OH-PLIF) imaging is performed up to a 2 MHz repetition rate to track the combustion products and reaction zone locations. In the same annular RDC, a single liquid fuel jet is injected, and laser-based 355-nm imaging of the fuel spray is performed up to a 1 MHz repetition rate. For this configuration, the annular RDC is used as a detonation driver to impose periodic detonation waves to interact with the fuel spray. Moreover, in this annular RDC, a range of tracer-based laser imaging measurements are explored to time-resolve the unsteady oxidizer air recovery and refill process. In a non-premixed linear RDC, planar imaging measurements of the fuel mixing are performed up to a 200 kHz repetition rate using PLIF of a tracer in the fuel supply. The fuel mixing imaging helps explain the origin of the observed pre and post wave burning, detonation structure, and enables quantifying injector recovery timescales. This paper will provide a high-level broad survey of diagnostics applied in these RDCs, lessons learned, and interesting observations.

Combustion↗

Advanced Diagnostics For Megahertz Imaging Of Mixing, Fuel Spray, And Combustion Processes For Rotating Detonation Combustors

Recent advancements in megahertz rate, high-power, burst-mode laser technology are leveraged to perform and explore imaging measurements that spatially and temporally resolve the mixing, combustion, and detonation flow field in two laboratory-scale rotating detonation combustors (RDCs). In a non-premixed annular RDC, multiple imaging diagnostics are explored to investigate gaseous and liquid injector behavior, the detonation wave structure, and the propellant refill. In one instance, OH planar laser-induced fluorescence (OH-PLIF) imaging is performed up to a 2 MHz repetition rate to track the combustion products and reaction zone locations. In the same annular RDC, a single liquid fuel jet is injected, and laser-based 355-nm imaging of the fuel spray is performed up to a 1 MHz repetition rate. For this configuration, the annular RDC is used as a detonation driver to impose periodic detonation waves to interact with the fuel spray. Moreover, in this annular RDC, a range of tracer-based laser imaging measurements are explored to time-resolve the unsteady oxidizer air recovery and refill process. In a non-premixed linear RDC, planar imaging measurements of the fuel mixing are performed up to a 200 kHz repetition rate using PLIF of a tracer in the fuel supply. The fuel mixing imaging helps explain the origin of the observed pre and post wave burning, detonation structure, and enables quantifying injector recovery timescales. This paper will provide a high-level broad survey of diagnostics applied in these RDCs, lessons learned, and interesting observations.

Combustion↗

Electrical design of the flexible imaging diffraction diagnostic for laser experiments (FIDDLE) at the National Ignition Facility (NIF)—Requirements, design, and performance

The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a newly developed diagnostic for imaging time resolved diffraction in experiments at the National Ignition Facility (NIF). It builds on the successes of its predecessor, the Gated Diffraction Development Diagnostic (G3D). The FIDDLE was designed to support eight Daedalus version 2 sensors (six more hCMOS sensors than any other hCMOS-based diagnostic in NIF to date) and an integrated streak camera. We will review the electrical requirements, design, and performance of the electrical subsystems that were created to support this large number of cameras in the FIDDLE. The analysis of the data that the FIDDLE is intended to collect relies heavily on the accurate and well-understood timing of each sensor. We report camera-to-camera timing jitter of less than 100 ps rms and sensor integration times of 2.2 ns FWHM in 2-2 timing mode. Additionally, diffraction experiments on the NIF produce electric fields (EMI) on the order of 1 kV/m, which have been observed to negatively impact the performance of some electrical components of the FIDDLE. We report on the results of testing hCMOS camera electronics in a similar EMI environment generated in an offline lab. In addition, we also summarize the use of a novel approach to using a vector network analyzer as an EMI leak detector to understand and reduce the negative impacts of EMI on the FIDDLE.

47 OTHER INSTRUMENTATION↗

Implementation of heterodyne detection of radio frequency waves using phase contrast imaging

An upgrade to the DIII–D phase contrast imaging (PCI) diagnostic for detection of radio frequency waves has been implemented using low-noise optical heterodyning. Electro-optical modulation allows detection of waves with frequencies up to 500 MHz with wide flexibility restricted only by the driver electronics, with continuous adjustability up to 100 MHz and fixed frequency drivers needed for higher frequencies. The PCI diagnostic images the line-integrated plasma density fluctuations and provides absolutely calibrated measurements with good wavenumber resolution.

Rost, J. C. [Massachusetts Institute of Technology↗