Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A soft x-ray transmission grating imaging-spectrometer for the National Ignition Facility

A soft x-ray transmission grating spectrometer has been designed for use on high energy-density physics experiments at the National Ignition Facility (NIF); coupled to one of the NIF gated x-ray detectors it records 16 time-gated spectra between 250 and 1000 eV with 100 ps temporal resolution. The trade-off between spectral and spatial resolution leads to an optimized design for measurement of emission around the peak of a 100-300 eV blackbody spectrum. Performance qualification results from the NIF, the Trident Laser Facility and vacuum ultraviolet beamline at the National Synchrotron Light Source, evidence a <100 {mu}m spatial resolution in combination with a source-size limited spectral resolution that is <10 eV at photon energies of 300 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A split imaging spectrometer for temporally and spatially resolved titanium absorption spectroscopy

We present a temporally and a spatially resolved spectrometer for titanium x-ray absorption spectroscopy along 2 axial symmetric lines-of-sight. Each line-of-sight of the instrument uses an elliptical crystal to acquire both the 2p and 3p Ti absorption lines on a single, time gated channel of the instrument. The 2 axial symmetric lines-of-sight allow the 2p and 3p absorption features to be measured through the same point in space using both channels of the instrument. The spatially dependent material temperature can be inferred by observing the 2p and the 3p Ti absorption features. The data are recorded on a two strip framing camera with each strip collecting data from a single line-of-sight. The design is compatible for use at both the OMEGA laser and the National Ignition Facility. The spectrometer is intended to measure the material temperature behind a Marshak wave in a radiatively driven SiO{sub 2} foam with a Ti foam tracer. In this configuration, a broad band CsI backlighter will be used for a source and the Ti absorption spectrum measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photodissociation Dynamics of Astrophysically Relevant Propyl Derivatives (C 3 H 7 X; X = CN, OH, HCO) at 157 nm Exploiting an Ultracompact Velocity Map Imaging Spectrometer: The (Iso)Propyl Channel

The photodissociation dynamics of astrophysically relevant propyl derivatives (C 3 H 7 X; X = CN, OH, HCO) at 157 nm exploiting an ultracompact velocity map imaging (UVMIS) setup has been reported. The successful operation of UVMIS allowed the exploration of the 157 nm photo dissociation of six (iso)propyl systems - n/i-propyl cyanide (C 3 H 7 CN), n/i-propyl alcohol (C 3 H 7 OH), and (iso)butanal (C 3 H 7 CHO) – to explore the C 3 H 7 loss channel. The distinct center-of-mass translational energy distributions for the i-C 3 H 7 X (X= CN, OH, HCO) could be explained through preferential excitation of the low frequency C-H bending modes of the formyl moiety compared to the higher frequency stretchings of the cyano and hydroxy moieties. Although the ionization energy of the n-C 3 H 7 radical exceeds the energy of a 157 nm photon, C 3 H 7 + was observed in the n-C 3 H 7 X (X= CN, OH, HCO) systems as a result of photoionization of vibrationally "hot" n-C 3 H 7 fragments, photoionization of i-C 3 H 7 after a hydrogen shift in vibrationally "hot" n-C 3 H 7 radicals, and/or two-photon ionization. Our experiments reveal that at least the isopropyl radical (i-C 3 H 7 ) and possibly the normal propyl radical (n-C 3 H 7 ) should be present in the interstellar medium and hence searched for by radio telescopes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WARM AND FUZZY: TEMPERATURE AND DENSITY ANALYSIS OF AN Fe XV EUV IMAGING SPECTROMETER LOOP

The Hinode EUV Imaging Spectrometer (EIS) and X-Ray Telescope (XRT) were designed in part to work together. They have the same spatial resolution and cover different but overlapping coronal temperature ranges. These properties make a combined data set ideal for multithermal analysis, where EIS provides the best information on the cooler corona (log T < 6.5) and XRT provides the best information on the hotter corona (log T > 6.5). Here, we analyze a warm non-flaring loop detected in images made in a strong EIS Fe XV emission line with a wavelength of 284.16 A and peak formation temperature of log T = 6.3. We perform differential emission measure (DEM) analysis in three pixels at different heights above the footpoint and find multithermal results with the bulk of the emission measure in the range 6.0 < log T < 6.6. Analysis with the EIS lines alone gave a DEM with huge amounts of emission measure at very high temperatures (log T >7.2); analysis with XRT data alone resulted in a DEM that was missing most of the cooler emission measure required to produce many of the EIS lines. Thus, both results were misleading and unphysical. It was only by combining the EIS and XRT data that we were able to produce a reasonable result, one without ad hoc assumptions on the shape and range of the DEM itself.

79 ASTRONOMY AND ASTROPHYSICS↗

Dual waveband compact catadioptric imaging spectrometer

A catadioptric dual waveband imaging spectrometer that covers the visible through short-wave infrared, and the midwave infrared spectral regions, dispersing the visible through shortwave infrared with a zinc selenide grating and midwave infrared with a sapphire prism. The grating and prism are at the cold stop position, enabling the pupil to be split between them. The spectra for both wavebands are focused onto the relevant sections of a single dual waveband detector. Spatial keystone distortion is controlled to less than one tenth of a pixel over the full wavelength range, facilitating the matching of the spectra in the midwave infrared with the shorter wavelength region.

47 OTHER INSTRUMENTATION↗

C-III flow measurements with a coherence imaging spectrometer

This work describes a coherence imaging spectrometer capable of making spatially resolved CIII flow measurements in the DIII-D lower divertor. The spectrometer exploits a periscope view of the plasma to produce line-of-sight averaged velocity measurements of CIII. From these chord averaged flow measurements, a 2D poloidal cross section of the CIII flow is tomographically reconstructed. Details of the diagnostic setup, acquired data, and data analysis will be presented, along with prospects for future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting X-ray Emission from Cometary Atmospheres Using the Suzaku X-ray Imaging Spectrometer

The Suzaku X-ray imaging spectrometer has been used to observe the X-ray emission from comets 73P/Schwassmann-Wachmann 3C and 8P/Tuttle. Comet 73P/Schwassmann-Wachmann 3C was observed during May and June of 2006, while it was near perihelion and passed within 0.1 AU of the Earth. Comet 8P/Tuttle was observed during January of 2008 when it was at its closest approach to the Earth at 0.25 AU, and again near perihelion at a distance of 0.5 Au from Earth. In the case of comet 73P/Schwassmann Wachmann 3C, the XIS spectra show line emission from highly charged oxygen and carbon ions as well as emission from what is most likely L-shell transitions from Mg, Si, and S ions. This line emission is caused by charge exchange recombination between solar wind ions and cometary neutrals, and can be used as a diagnostic of the solar wind. Here we present some of the results of the observation of the comet 73P/Schwassmann-Wachmann 3C.

99 GENERAL AND MISCELLANEOUS↗

Development and characterization of a multiple-coincidence ion-momentum imaging spectrometer

The design and performance of a high-resolution momentum-imaging spectrometer for ions which is optimized for experiments using synchrotron radiation is presented. High collection efficiency is achieved by a focusing electrostatic lens; a long drift tube improves mass resolution and a position-sensitive detector enables measurement of the transverse momentum of ions. The optimisation of the lens for particle momentum measurement at the highest resolution is described. We discuss the overall performance of the spectrometer and present examples demonstrating the momentum resolution for both kinetics and for angular measurements in molecular fragmentation for carbon monoxide and fullerenes. Examples are presented that confirm that complete space-time focussing is possible for a two-field three-dimensional imaging spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospects of X-ray imaging spectrometers for impurity transport: Recent results from the stellarator Wendelstein 7-X (invited)

This paper reports on the design and the performance of the recently upgraded X-ray imaging spectrometer systems, X-ray imaging crystal spectrometer and high resolution X-ray imaging spectrometer, installed at the optimized stellarator Wendelstein 7-X. High resolution spectra of highly ionized, He-like Si, Ar, Ti, and Fe as well as H-like Ar have been observed. A cross comparison of ion and electron temperature profiles derived from a spectral fit and tomographic inversion of Ar and Fe spectra shows a reasonable match with both the spectrometers. The also measured impurity density profiles of Ar and Fe have peaked densities at radial positions that are in qualitative agreement with the expectations from the He-like impurity fractional abundances, given the measured temperature profiles. In conclusion, repeated measurements of impurity decay times have been demonstrated with an accuracy of 1 ms via injection of non-recycling Ti, Fe, and Mo impurities using a laser blow-off system.

47 OTHER INSTRUMENTATION↗

Transfer-matrix-based method for an analytical description of velocity-map-imaging spectrometers

We propose a simple and general analytical model describing the operation of a velocity-map-imaging spectrometer. We show that such a spectrometer, possibly equipped with a magnifying lens, can be efficiently modeled by combining analytical expressions for the axial potential distributions along with a transfer matrix method. The model leads transparently to the prediction of the instrument's operating conditions as well as to its resolution. A photoelectron velocity-map-imaging spectrometer with a magnifying lens, built and operated along the lines suggested by the model has been successfully employed for recording images at threshold photoionization of atomic lithium. The model's reliability is demonstrated by the fairly good agreement between experimental results and calculations. Finally, the limitations of the analytical method along with possible generalizations, extensions, and potential applications are also discussed. The model may serve as a guide for users interested in building and operating such spectrometers as well as a tutorial tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Echelle grating multi-order imaging spectrometer utilizing a catadioptric lens

A cryogenically cooled imaging spectrometer that includes a spectrometer housing having a first side and a second side opposite the first side. An entrance slit is on the first side of the spectrometer housing and directs light to a cross-disperser grating. An echelle immersions grating and a catadioptric lens are positioned in the housing to receive the light. A cryogenically cooled detector is located in the housing on the second side of the spectrometer housing. Light from the entrance slit is directed to the cross-disperser grating. The light is directed from the cross-disperser grating to the echelle immersions grating. The light is directed from the echelle immersions grating to the cryogenically cooled detector on the second side of the spectrometer housing.

47 OTHER INSTRUMENTATION↗

MULTIPLE COMPONENT OUTFLOWS IN AN ACTIVE REGION OBSERVED WITH THE EUV IMAGING SPECTROMETER ON HINODE

We have used the Extreme Ultraviolet Imaging Spectrometer on the Hinode spacecraft to observe large areas of outflow near an active region. These outflows are seen to persist for at least 6 days. The emission line profiles suggest that the outflow region is composed of multiple outflowing components, Doppler-shifted with respect to each other. We have modeled this scenario by imposing a double-Gaussian fit to the line profiles. These fits represent the profile markedly better than a single-Gaussian fit for Fe XII and XIII emission lines. For the fastest outflowing components, we find velocities as high as 200 km s{sup -1}. However, there remains a correlation between the fitted line velocities and widths, suggesting that the outflows are not fully resolved by the double-Gaussian fit and that the outflow may be comprised of further components.

79 ASTRONOMY AND ASTROPHYSICS↗

Wide swath imaging spectrometer utilizing a multi-modular design

A wide swath imaging spectrometer utilizing an array of individual spectrometer modules in the telescope focal plane to provide an extended field of view. The spectrometer modules with their individual detectors are arranged so that their slits overlap with motion on the scene providing contiguous spatial coverage. The number of modules can be varied to take full advantage of the field of view available from the telescope.

Chrisp, Michael P↗

THE ABSOLUTE CALIBRATION OF THE EUV IMAGING SPECTROMETER ON HINODE

We investigate the absolute calibration of the EUV Imaging Spectrometer (EIS) on Hinode by comparing EIS full-disk mosaics with irradiance observations from the EUV Variability Experiment on the Solar Dynamics Observatory. We also use extended observations of the quiet corona above the limb combined with a simple differential emission measure model to establish new effective area curves that incorporate information from the most recent atomic physics calculations. We find that changes to the EIS instrument sensitivity are a complex function of both time and wavelength. We find that the sensitivity is decaying exponentially with time and that the decay constants vary with wavelength. The EIS short wavelength channel shows significantly longer decay times than the long wavelength channel.

79 ASTRONOMY AND ASTROPHYSICS↗

High-resolution imaging spectrometer for recording absolutely calibrated far ultraviolet spectra from laser-produced plasmas

An imaging spectrometer was designed and fabricated for recording far ultraviolet spectra from laser-produced plasmas with wavelengths as short as 155 nm. The spectrometer implements a Cassegrain telescope and two gratings in a tandem Wadsworth optical configuration that provides diffraction limited resolution. Spectral images were recorded from plasmas produced by the irradiation of various target materials by intense KrF laser radiation with 248 nm wavelength. Two pairs of high-resolution gratings can be selected for the coverage of two wavebands, one grating pair with 1800 grooves/mm and covering approximately 155-175 nm and another grating pair with 1200 grooves/mm covering 230-260 nm. The latter waveband includes the 248 nm KrF laser wavelength, and the former waveband includes the wavelength of the two-plasmon decay instability at (2/3) the KrF laser wavelength (165 nm). The detection media consist of a complementary metal oxide semiconductor imager, photostimulable phosphor image plates, and a linear array of 1 mm{sup 2} square silicon photodiodes with 0.4 ns rise time. The telescope mirrors, spectrometer gratings, and 1 mm{sup 2} photodiode were calibrated using synchrotron radiation, and this enables the measurement of the absolute emission from the laser-produced plasmas with temporal, spatial, and spectral resolutions. The spectrometer is capable of measuring absolute spectral emissions at 165 nm wavelength as small as 5x10{sup -7} J/nm from a plasma source area of 0.37 mm{sup 2} and with 0.4 ns time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VELOCITY CHARACTERISTICS OF EVAPORATED PLASMA USING HINODE/EUV IMAGING SPECTROMETER

This paper presents a detailed study of chromospheric evaporation using the EUV Imaging Spectrometer (EIS) onboard Hinode in conjunction with hard X-ray (HXR) observations from Reuven Ramaty High-Energy Solar Spectroscopic Imager (RHESSI). The advanced capabilities of EIS were used to measure Doppler shifts in 15 emission lines covering the temperature range T = 0.05-16 MK during the impulsive phase of a C-class flare on 2007 December 14. Blueshifts indicative of the evaporated material were observed in six emission lines from Fe XIV-XXIV (2-16 MK). Upflow velocity (v{sub up}) was found to scale with temperature as v{sub up} (km s{sup -1}) {approx} 8-18T(MK). Although the hottest emission lines, Fe XXIII and Fe XXIV, exhibited upflows of >200 km s{sup -1}, their line profiles were found to be dominated by a stationary component in contrast to the predictions of the standard flare model. Emission from O VI-Fe XIII lines (0.5-1.5 MK) was found to be redshifted by v{sub down} (km s{sup -1}) {approx} 60-17T (MK) and was interpreted as the downward-moving 'plug' characteristic of explosive evaporation. These downflows occur at temperatures significantly higher than previously expected. Both upflows and downflows were spatially and temporally correlated with HXR emission observed by RHESSI that provided the properties of the electron beam deemed to be the driver of the evaporation. The energy flux of the electron beam was found to be {approx}>5 x 10{sup 10} erg cm{sup -2} s{sup -1}, consistent with the value required to drive explosive chromospheric evaporation from hydrodynamic simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Momentum imaging spectrometer for molecular fragmentation dynamics induced by pulsed electron beam

A momentum imaging spectrometer has been built for studying the electron impact molecular fragmentation dynamics. The setup consists of a pulsed electron gun and a time of flight system as well as a two-dimensional time and position sensitive multi-hit detector. The charged fragments with kinetic energy up to 10 eV can be detected in 4π solid angles and their three-dimensional momentum vectors can be reconstructed. The apparatus is tested by electron impact ionization of Ar and dissociative ionization of CO{sub 2}. By analyzing the ion-ion coincidence spectra, the complete and incomplete Coulomb fragmentation channels for CO{sub 2}{sup 2+} and CO{sub 2}{sup 3+} are identified. The kinetic energy release (KER) and angular correlation for the two-body breakup channel CO{sub 2}{sup 2+*}→ O{sup +}+ CO{sup +} are reported. The peak value of total KER is found to be 6.8 eV which is consistent with the previous photoion-photoion coincidence studies, and the correlation angle of O{sup +} and CO{sup +} is also explicitly determined to be 172.5°.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

USING HINODE/EXTREME-ULTRAVIOLET IMAGING SPECTROMETER TO CONFIRM A SEISMOLOGICALLY INFERRED CORONAL TEMPERATURE

The Extreme-Ultraviolet Imaging Spectrometer on board the HINODE satellite is used to examine the loop system described in Marsh et al. by applying spectroscopic diagnostic methods. A simple isothermal mapping algorithm is applied to determine where the assumption of isothermal plasma may be valid, and the emission measure locii technique is used to determine the temperature profile along the base of the loop system. It is found that, along the base, the loop has a uniform temperature profile with a mean temperature of 0.89 +- 0.09 MK which is in agreement with the temperature determined seismologically in Marsh et al., using observations interpreted as the slow magnetoacoustic mode. The results further strengthen the slow mode interpretation, propagation at a uniform sound speed, and the analysis method applied in Marsh et al. It is found that it is not possible to discriminate between the slow mode phase speed and the sound speed within the precision of the present observations.

79 ASTRONOMY AND ASTROPHYSICS↗