Search NASASearch

SEARCH · Search NASA

Results for “imaging techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

XFEL imaging techniques for high energy density and inertial fusion energy research at HED-HiBEF

The imaging platform developed at the High Energy Density-Helmholtz International Beamline for Extreme Fields (HED-HiBEF) instrument at the European X-ray Free Electron Laser (XFEL) and its applications to HED and fusion related research are presented. The platform combines the XFEL beam with the high-intensity short-pulse laser ReLaX and the high-energy nanosecond-pulse laser DiPOLE-100X. The spatial resolution is better than 500 nm and the temporal resolution of the order of 50 fs. The influence of the XFEL source in the x-ray imaging method is discussed. Free-propagation x-ray phase contrast imaging and Talbot-Lau imaging setups are shown. We show examples of blast waves and converging cylindrical shocks in aluminum, resonant absorption measurements of specific charged states in copper with ReLaX and planar shocks in polystyrene material generated by DiPOLE-100X. For the first time, we show the application of Talbot-Lau interferometry to convergent cylindrical shocks as well as resonant absorption processes. We also discuss the possibilities introduced by combining this imaging platform with a kJ-class laser.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Correlating energy density induced residual stress, porosity, and mechanical property variations in directed energy deposition using neutron diffraction and imaging techniques

In a directed energy deposition (DED) process, the energy density deposited into the materials drives the structure and properties. The energy density is influenced by several printing parameters, such as laser power, hatch spacing, scanning speed, etc. In this study, 316L stainless steels samples were fabricated with varying hatch spacing aiming to induce variations in sample microstructure and properties. A combination of techniques including engineering neutron diffraction, neutron computed tomography, and tensile testing, were employed to correlate the structure and macroscopic properties. Porosity was predominantly observed at the bottom of the deposited materials and was effectively reduced by decreased hatch spacing. Correlatively, compressive residual stress was observed at the bottom of the specimens, while internal stress is largely determined by the hatch spacing. The residual stress in general decreases as the hatch spacing decreases. The maximum ultimate tensile strength (UTS) was found to increase from 517.4 to 528.6 MPa with a strain increased from 0.847 to 0.897 as the hatch spacing decreased from 0.45 to 0.42 mm. However, further increase in energy density by reducing the hatch spacing resulted in a significant decrease in UTS (as low as 452 MPa). This work provides new insights from bulk non-destructive techniques into correlating energy density induced residual stress, porosity, and mechanical property variations in directed energy deposition.

316L stainless steel

An Internal Digital Image Correlation Technique for High-Strain Rate Dynamic Experiments

Full-field, quantitative visualization techniques, such as digital image correlation (DIC), have unlocked vast opportunities for experimental mechanics. However, DIC has traditionally been a surface measurement technique, and has not been extended to perform measurements on the interior of specimens for dynamic, full-scale laboratory experiments. This limitation restricts the scope of physics which can be investigated through DIC measurements, especially in the context of heterogeneous materials. The focus of this study is to develop a method for performing internal DIC measurements in dynamic experiments. The aim is to demonstrate its feasibility and accuracy across a range of stresses (up to 650 MPa), strain rates (10 3 - 10 6 s -1 ), and high-strain rate loading conditions (e.g., ramped and shock wave loading). Internal DIC is developed based on the concept of applying a speckle pattern at an inner-plane of a transparent specimen. The high-speed imaging configuration is coupled to the traditional dynamic experimental setups, and is focused on the internal speckle pattern. During the experiment, while the sample deforms dynamically, in-plane, two-dimensional deformations are measured via correlation of the internal speckle pattern. In this study, the viability and accuracy of the internal DIC technique is demonstrated for split-Hopkinson (Kolsky) pressure bar (SHPB) and plate impact experiments. The internal DIC experimental technique is successfully demonstrated in both the SHPB and plate impact experiments. In the SHPB setting, the accuracy of the technique is excellent throughout the deformation regime, with measurement noise of approximately 0.2% strain. In the case of plate impact experiments, the technique performs well, with error and measurement noise of 1% strain. The internal DIC technique has been developed and demonstrated to work well for full-scale dynamic high-strain rate and shock laboratory experiments, and the accuracy is quantified. Here, the technique can aid in investigating the physics and mechanics of the dynamic behavior of materials, including local deformation fields around dynamically loaded material heterogeneities.

36 MATERIALS SCIENCE

Benchmarking image processing techniques for porosity measurement in polymer additive manufacturing: Review and experimental analysis

An image processing workflow is proposed for porosity measurement in polymer additive manufacturing. Various techniques, including global and local thresholding, region growing, and K-means clustering, were applied to microscopic images of carbon fiber reinforced acrylonitrile butadiene styrene (CF-ABS) and benchmarked for their ability to accurately measure porosity. Global methods included Otsu, minimum error, iterative, and entropy-based thresholding, while local methods included Niblack, Bernsen, Sauvola, and Bradley-Roth algorithms. Artificial uneven illumination was introduced to test local adaptive thresholds. Results showed significant differences in porosity values across methods. Otsu, region growing, and K-means clustering excelled under uniform illumination, while Sauvola and Bradley-Roth performed better with uneven illumination. Comparison with X-ray computed tomography (XCT) revealed slightly lower porosity values (2.55 %) than optimized methods (2.73–2.79 %) due to XCT's lower resolution excluding smaller pores. While XCT offers finer pore detection, it limits sample volume and underestimates porosity due to spatial variation. Validation using artificial grayscale images with 5 % porosity confirmed that Otsu, Bradley-Roth, region growing, and Sauvola algorithms produced accurate results. Although tested on a single material system, these methods can be adapted to others with optimization. In conclusion, given XCT's high computational and time costs, this study highlights suitable image processing techniques as cost-effective alternatives for porosity analysis in polymer composites.

Additive manufacturing

STEM Ptychographic Holography of Electric and Magnetic Potentials

The development of fast an efficient direct electron imaging detectors have enabled the advancement of phase-imaging techniques in STEM such as iterative ptychography. As beneficial as these techniques are to imaging phase objects, the information recorded in the raw data is due to phase gradients across the probe, so it can be challenging to reconstruct slowly varying phase at lower spatial frequencies such as those induced by electric or magnetic potentials within the specimen. STEM holography [1,2] is an interferometric 4D-STEM technique where electrons in the beam are coherently divided into a superposition of two or more spatially separated probes which are then scanned over the specimen. For example, in a two-beam superposition, the two probes form overlapping bright field discs at the detector which then interfere (left of Fig. 1). Furthermore, if one probe passes through vacuum while the other transmits through the specimen, the resulting relative phase shift can be measured by recording shifts in the interference pattern. STEM holography is thus directly sensitive to the phase of the probe relative to the reference beam, and this phase can be measured regardless of the convergence angle of the probe, unlike single beam ptychography.

Biological Sciences

Extraction of ground-state nuclear deformations from ultrarelativistic heavy-ion collisions: Nuclear structure physics context

The collective-flow-assisted nuclear shape-imaging method in ultrarelativistic heavy-ion collisions (UHICs) has recently been used to characterize nuclear collective states. In this paper, we assess the foundations of the shape-imaging technique employed in these studies. We argue that some current UHIC nuclear imaging techniques neglect fundamental aspects of spontaneous symmetry breaking and symmetry restoration in colliding ions and incorrectly infer one-body multipole moments from studies of nucleonic correlations. Therefore, the impact of this approach on nuclear structure research has been overstated. Conversely, efforts to incorporate existing knowledge on nuclear shapes into analysis pipelines can be beneficial for benchmarking tools and calibrating models used to extract information from ultrarelativistic heavy-ion experiments.

Nuclear data analysis & compilation

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Magnetic field driven emergent phenomena: Insights from magneto-optics and nanoscopy

This review explores magnetic field-driven emergent phenomena across various material systems, emphasizing the pivotal roles of magneto-optical and nanoscopy techniques. We examine fundamental aspects of Landau electrodynamics in both 2D and 3D systems, including quantum Hall and topological magnetoelectric effects in graphene and topological insulators. Particularly attention is given to magnetic excitations and magnetopolaritons, such as surface magnon polaritons, magnetoplasmons, and magnetoexcitons in novel quantum materials, including quantum magnets and hybrid heterostructures. Advanced imaging techniques, such as scattering-type scanning near-field optical microscopy (SNOM) and microwave impedance microscopy, are showcased for their capability to resolve these phenomena with microscopic and nanoscopic resolution. These insights are complemented by discussions of advanced experimental approaches, including cryogenic environments, ultrafast pump-probe techniques, and the integration of magnetic fields into near-field optical methodologies. We further investigate the potential of these imaging techniques for unraveling complex magnetic orders, quantum phases, and correlated electronic behaviors. Finally, we offer perspectives on future research directions and highlight emerging opportunities in the evolving field of optical magneto-nanoscopy.

36 MATERIALS SCIENCE

Observation of nanoparticle coalescence during core-shell metallic nanowire growth in colloids via nanoscale imaging

The surface morphology and shape of crystalline nanowires significantly influence their functional properties, including phonon transport, electrocatalytic performance, to name but a few. However, the kinetic pathways driving these morphological changes remain underexplored due to challenges in real-space and real-time imaging at single-particle and atomic resolutions. This study investigates the dynamics of shell (Au, Pd, Pt, Fe, Cu, Ni) deposition on AuAg alloy seed nanowires during core-shell formation. By using chiral/non-chiral seed nanowires, advanced imaging techniques, including liquid-phase transmission electron microscopy (LPTEM), cryogenic TEM, and three-dimensional electron tomography, a three-step deposition process is revealed: heterogeneous nucleation, nanoparticle attachment, and coalescence. It is found that colloidal Ostwald ripening, metal reactivity, and deposition amount modulate nanoparticle size and surface roughness, shaping final morphologies. Noble metal nanoparticles (Au, Ag, Pd, Pt) coalesce with seed nanowire along the 〈111〉 direction, distinct from that of other metals. These findings are consistent across different metals, including Ru, Cu, Fe, and Ni, highlighting the hypothesis of these processes in nanowire formation. These findings enhance traditional crystallographic theories and provide a framework for designing nanowire morphology. Additionally, our imaging techniques may be applied to investigate phenomena like electrodeposition, dendrite growth in batteries, and membrane deformation.

Yang, Dahai

Image registration for accurate electrode deformation analysis in operando microscopy of battery materials

Operando imaging techniques have become increasingly valuable in both battery research and manufacturing. However, the reliability of these methods can be compromised by instabilities in the imaging setup and operando cells, particularly when utilizing high-resolution imaging systems. The acquired imaging data often include features arising from both undesirable system vibrations and drift, as well as the scientifically relevant deformations occurring in the battery sample during cell operation. For meaningful analysis, it is crucial to distinguish and separately evaluate these two factors. To address these challenges, we employ a suite of advanced image-processing techniques. These include fast Fourier transform analysis in the frequency domain, power spectrum-based assessments for image quality, as well as rigid and non-rigid image-registration methods. These techniques allow us to identify and exclude blurred images, correct for displacements caused by motor vibrations and sample holder drift and, thus, prevent unwanted image artifacts from affecting subsequent analyses and interpretations. Additionally, we apply optical flow analysis to track the dynamic deformation of battery electrode materials during electrochemical cycling. This enables us to observe and quantify the evolving mechanical responses of the electrodes, offering deeper insights into battery degradation. Together, these methods ensure more accurate image analysis and enhance our understanding of the chemomechanical interplay in battery performance and longevity.

Sun, Tianxiao

Whole-scene, one-sided backscatter x-ray imaging with coded apertures

X-ray radiography can be an important diagnostic for emergency response, providing timely diagnostic information about a suspect object. However, there are situations where similar information would be better obtained with a one-sided imaging technique. X-ray backscatter imaging is a proven technology that could provide such information, but current implementations have drawbacks that render it unsuitable for emergency response. We are exploring the use of coded-aperture imaging to create one-sided images, targeting a key benefit: implementation requiring minimal additional resources, bypassing logistics issues. We present results demonstrating the feasibility of this approach.

Ziock, Klaus-Peter [ORNL]

Fresnel diffraction imaging of surface nanostructure using coherent resonant x-ray scattering

We investigated surface nanostructures on an antiferromagnet MnBi 2 Te 4 using a novel imaging technique, direct (real)-space and real time coherent x-ray imaging (direct-CXI). This technique has provided new insights into antiferromagnetic textures, including the formation of anti-phase antiferromagnetic (AFM) domains and thermal dynamics of AFM domains and domain walls. While this method produces real-space images of AFM textures without requiring a complex imaging retrieval process, its underlying imaging mechanism has not been fully understood, limiting a deep understanding of AFM textures and the information they contain. By investigating the well-defined structural characteristics of the nanostructures fabricated on MnBi 2 Te 4 ⁠, we elucidate the imaging principle of this novel technique. We find that the observed images can be well explained by the Fresnel diffraction integral. Using a simple model from classical optics, our calculations successfully reproduce the experimentally observed images of the nanostructures. This demonstrates that direct-CXI not only provides straightforward real-space imaging but also contains phase information through its Fresnel diffraction integral.

36 MATERIALS SCIENCE

Associated Particle Imaging of Neutron Inelastic Scatter: 3-D Reconstruction, Capabilities, and Challenges

Associated particle imaging (API) offers unique advantages for 3-D imaging of neutron inelastic scatter, including single-view tomographic imaging and data acquisition when access is limited to only one side of the interrogated object. However, widespread adoption of neutron inelastic scatter imaging has been impeded by several inherent challenges, most prominently spatial resolution, self-attenuation, and statistical noise. Here, in this work, the capabilities and challenges of neutron inelastic scatter imaging are investigated. Instead of focusing on a single imaging application, we identify imaging principles that hold for various neutron inelastic scatter imaging techniques. The primary challenges for 3-D imaging are characterized. The inherent spatial resolution in the time-of-flight (TOF) dimension is derived based on the known system timing resolution and scan geometry. Three reconstruction algorithms are described and demonstrated, including the introduction of modern iterative reconstruction incorporating a physics-based system model. Simulation is leveraged to demonstrate imaging capability with varying coincidence count levels and system timing resolution. An example of measured data with both back-scatter and forward-scatter detector positioning is presented. System design characteristics and their effects on image quality are identified. The imaging framework presented in this article has the potential to facilitate growth of 3-D neutron inelastic scatter API by identifying applications that are a good match for the technique and by targeting system development resources toward the requirements of a specific imaging task.

Associated particle imaging (API)

Longitudinal position dependence of dark line defect growth rate in high-power diode lasers at 790 nm

Using a nondestructive, in situ near-infrared defect imaging technique, we obtained time-resolved images of dark line defect (DLD) growth in the cavities of several high-power 790-nm diode lasers and calculated individual DLD growth rates. A clear longitudinal spatial dependence in the DLD growth rate was observed, in which the DLD growth rate was faster near the anti-reflective (AR) facet. Longitudinal spatial hole burning simulation results indicate that the total photon density increases toward the AR facet, while the carrier density decreases toward the AR facet. Here, these results suggest that photon absorption plays a key role in enhancing DLD growth beyond the contribution of the traditional carrier capture mechanism. Asymmetric DLD growth that was preferentially directed toward the high-reflectivity facet was also observed, providing further support for the role of photon absorption in the growth process. To account for these findings, we propose a photon-accelerated mechanism for the enhancement of DLD growth in which the slower carrier capture process in the traditional recombination-enhanced dislocation glide mechanism is replaced by a faster photon absorption process.

Engineering - Electronic and electrical engineerin

Development of high throughput light-sheet fluorescence lifetime imaging microscopy for 3D functional imaging of metabolic pathways in plant and microorganisms (Final Technical Report)

This research program will enable new biochemical contrast in the nanosecond lifetime domain through use of the recently demonstrated electro-optic fluorescence lifetime imaging technique (EO-FLIM) for wide-field lifetime imaging. The Stanford/Stanford Linear Accelerator Center multidisciplinary collaboration -- physics, applied physics, and structural biology -- will develop a light-sheet fluorescence lifetime imaging microscope for functional studies of microbial and plant metabolic pathways and dynamic interactions between plants and microorganisms in the rhizosphere. The proposed approach overcomes the imaging time bottleneck associated with existing fluorescence lifetime imaging methods. Initial demonstrations have shown a factor of 100,000 improvement in photon throughput compared to existing methods. High photon efficiency allowed the first wide-field fluorescence lifetime imaging of single molecules. Recent work has improved the technique’s repetition rate to enable compatibility with mode-locked lasers and demonstrated the combination of wide-field fluorescence lifetime imaging with super-resolution localization microscopy, observations of single molecule dynamics, and observation of donor lifetime quenching in single-molecule imaging. These results were achieved on standard camera sensors and would not have been possible with other wide-field approaches. The throughput and photon economy of the EO-FLIM method enables new BER-relevant imaging opportunities. In particular, scanned single- and two-photon light-sheet excitation will be used to achieve volumetric imaging with time-domain contrast.

47 OTHER INSTRUMENTATION

FIRM image analysis: A machine learning workflow for quantifying extracellular matrix components from electron microscopy images

The extracellular matrix (ECM) is a complex network of biomolecules that plays an integral role in the structure, processes, and signaling mechanisms of cells and tissues. Identifying and quantifying changes in these matrix components provides insight into the mechanisms behind specific tissue remodeling processes; however, quantifying these changes is challenging due to difficult imaging conditions, complexity of the ECM, and the subtlety of these changes. Current imaging techniques allow us to visualize these critical remodeling events and developments in image analysis have employed a combination of analysis software and machine learning techniques to improve the efficiency and accuracy with which features are measured. Although image analysis has seen much improvement in recent years, there has been no technique developed to address ambiguity in feature edges in electron microscopy images. Presented here is a new machine learning-based workflow for the analysis of microscopy images named FIRM (Feature Identification from Raw Microscopy) that uses a random forest classifier to identify ECM features of interest and generate binary segmentation masks for quantification with ImageJ-FIJI. FIRM performed with an F1 score of 0.794 and greater than 80% accuracy for number and size of features detected. FIRM had similar deviation from the ground truth in the number of identified fibrils, fibril size, and size distributions when compared to human analyses. The results suggest that FIRM performs as well as manual analysis and requires a fraction of the time. This analysis technique is more efficient, eliminates user bias, and can be easily optimized to identify a variety of features, making it useful for any discipline requiring image analysis.

Science & Technology - Other Topics

Quantitative Modeling of High-Energy Electron Scattering in Thick Samples Using Monte Carlo Techniques

Cryo-electron microscopy (cryo-EM) is a powerful tool for imaging biological samples but is typically limited by sample thickness, which is restricted to a few hundred nanometers depending on the electron energy. However, there is a growing need for imaging techniques capable of studying biological samples up to 10 µm in thickness while maintaining nanoscale resolution. This need motivates the use of mega-electron-volt scanning transmission electron microscopy (MeV-STEM), which leverages the high penetration power of MeV electrons to generate high-resolution images of thicker samples. In this study, we employ Monte Carlo simulations to model electron–sample interactions and explore the signal decay of imaging electrons through thick specimens. By incorporating material properties, interaction cross-sections for energy loss, and experimental parameters, we investigate the relationship between the incident and transmitted beam intensities. Key factors such as detector collection angle, convergence semi-angle, and the material properties of samples were analyzed. Our results demonstrate that the relationship between incident and transmitted beam intensities follows the Beer–Lambert law over thicknesses ranging from a few microns to several tens of microns, depending on material composition, electron energy, and collection angles. The linear depth of silicon dioxide reaches 3.9 µm at 3 MeV, about 6 times higher than that at 300 keV. Meanwhile, the linear depth of amorphous ice reaches 17.9 µm at 3 MeV, approximately 11.5 times higher than that at 300 keV. These findings are crucial for advancing the study of thick biological and semiconductor samples using MeV-STEM.

36 MATERIALS SCIENCE

Experimental study of multiple-orientation muon tomography with image optimization in sparse data environments

Due to the high penetrating power of cosmic-ray muons, they can be used to probe very thick and dense objects. As muons are charged particles, they can be tracked by ionization detectors, determining the position and direction of the muons. With detectors on either side of an object to measure particle direction change, scattering information within the object can be found. This can be used to produce a scattering-intensity image within the object related to density and atomic number. Such imaging is typically performed with a single detector-object orientation, taking advantage of the more intense downward flux of muons, producing planar imaging with some depth-of-field information in the third dimension. Several simulation studies were published with multiorientation tomography, which can form a three-dimensional representation faster than a single-orientation view. In this study, experimental muon-scatter-based tomography was performed using a concrete filled steel drum with several different metal wedges inside, with the drum between detector planes. Data were collected from different detector-object orientations by rotating the steel drum. The data collected from each orientation were combined using two different tomographic methods. A traditional inverse Radon transform approach used for computed tomography and a combination of multiple depth-of-field reconstructions were applied to the data. As cosmic-ray muon flux imaging is rate limited, the imaging techniques were compared for sparse data. Using the combined depth-of-field reconstruction technique, fewer detector-object orientations were needed to reconstruct images that could be used to differentiate the metal wedges.

47 OTHER INSTRUMENTATION