Search NASA⌕ Search

SEARCH · Search NASA

Results for “impact analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Grid Impact Analysis of Heavy-Duty Electric Vehicle Charging Stations

This paper presents a grid impact analysis of heavy-duty electric vehicle (EV) charging stations. In this work, heavy-duty EVs have battery capacities high enough to provide a range of 250-500 miles on a single charge, such as long-haul trucks. Heavy-duty EVs will require extremely fast charging rates to reduce charging time and will induce very high charging loads (at the multiple-megawatt scale) if several vehicles charge at the same time. Therefore, analysis is needed to understand the impact of charging station loads on the electric power grid and set the baseline for developing mitigation plans and necessary system upgrades. We develop a systematic procedure to analyze the potential impact of the placement of charging stations on the grid. Charging load is modeled using a DC fast-charging station model. A voltage load sensitivity matrix approach is leveraged to investigate the challenges of placing charging stations on the feeder. Given the charging load profiles and suggested charging station locations, time-series simulations are performed on various connection points on the feeder to understand the impact. The analysis is performed on both the IEEE 34-bus system and a realistic feeder from California. Initial mitigation solutions are developed based on insights from this analysis.

47 OTHER INSTRUMENTATION↗

Explicit Dynamic Impact Analysis of the Building 3525 Packages

The safe transport and handling of radioactive material containers is critical to ensure the protection of personnel, facilities, and the environment. Accidental drops during handling pose a significant hazard, necessitating robust design and analysis to mitigate potential consequences. This study presents an explicit dynamic impact analysis of two container designs, the Baby Sugarman and the Core Conduction Cooldown Test Facility (CCCTF) Tall Boy, used in Building 3525 at Oak Ridge National Laboratory. The analysis employed nonlinear finite element modeling in LS-DYNA to simulate free-fall impacts from a height of 16.5 ft across eight critical orientations. The study evaluated deformation, strain failure, and shielding integrity under these extreme conditions. Results demonstrated that both designs maintain structural integrity, with no breaches or loss of shielding under specified administrative controls. Notably, a maximum shielding loss of 10 lbs was observed during a top-corner drop, highlighting the need to limit drop heights to less than 1 ft for certain orientations. These findings underscore the effectiveness of engineering controls and design measures in preventing containment breaches and ensuring compliance with safety requirements. This work provides a comprehensive methodology for impact analysis, contributing valuable insights to the field of radioactive materials packaging and transportation safety.

Martinez, Oscar [ORNL] (ORCID:0000000181814046)↗

Impact Analysis of Data Integrity Attacks on FACTS-based Wide-Area Voltage Control System

Energy management system (EMS) consists of several wide-area control applications that serve as a backbone for security, stability, and reliability of the power system. Wide-area voltage control system (WAVCS), one of the critical wide-area applications, operates in coordination with local Flexible AC Transmission System (FACTS) devices to provide voltage security and optimal management of active and reactive power resources. Since the WAVCS relies on wide-area communication and data sharing devices, possible cybersecurity vulnerabilities have to be addressed to ensure the closed-loop operation of WAVCS. In this paper, we present a methodology for performing an impact analysis of cyber-attacks in WAVCS cybersecurity. In particular, different types of data integrity attacks, such as malicious tripping, fault replay, and signal altering attacks, are considered, and detailed impact analysis is conducted in a testbed environment using the Kundur's four machine two-area system. For performing an impact analysis, the transient voltage stability of the sensitive bus voltage is studied, followed by the quantitative assessment and severity ranking using the voltage profile index. Our experimental evaluation reveals that the data integrity attacks on control signals exhibit a higher attack severity than on the measurement signals. Further, the severity of these attacks varies with nature (static or dynamic), location, and types of attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Novel Simulation-Based Framework for Sensor Error Impact Analysis in Smart Building Systems: A Case Study for a Demand-Controlled Ventilation System

Sensors are one of the fundamental components for sensor-rich controls in buildings but are prone to different errors. Existing studies show that sensor errors hold a place among top-priority faults in building systems. Before we take countermeasures to mitigate the sensor errors, it is vital to prioritize key sensors and quantify the collective impacts of concurrent sensor errors. In response to this, a simulation-based methodology is introduced to conduct a comprehensive sensor error impact analysis in building systems, which adds a stochastic sensor prioritization through a sensitivity analysis on top of a commonly used deterministic sensor error quantification. The synergies of these two parts help better interpret the sensor error impacts on building energy consumption, ventilation performance, thermal comfort, etc. A sensor-rich CO2-based Demand-Controlled Ventilation system is used as a case study to demonstrate the viability of the methodology as a proof-of-the-concept. The results show that the energy savings potential and ventilation performance are mostly influenced by the accuracy of the AHU outdoor airflow sensors. The accuracy of zone level airflow sensors has a negligible impact on both energy savings and ventilation performance. The accuracy of zone CO2 sensors has more influence on the ventilation performance compared with the accuracy of zone airflow sensors. Compared with the baseline case with zero errors, the largest deviation percentages could reach 16.90% and 94.32%, respectively, in terms of the Heating, Ventilation, and Air-Conditioning (HVAC) annual energy consumption and the Outdoor Air Ratio (OAR) when multiple key sensors suffer from normal error intensities simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact analysis of personalized thermostat demand response

Demand response (DR) aims to curtail peak electric load to avoid running inefficient power plants, reduce costly transmission capacity increases, and improve grid reliability. One method of DR for residential settings involves the utility or third part remotely adjusting thermostat temperatures. Cooling setpoints may be increased 2°F – 6°F for hours, irrespective of occupant comfort. To maintain their comfort, occupants override these setpoint changes impacting the reliability of DR services provided to the grid. This paper presents a preliminary impact analysis of replacing the current DR approach of uniform thermostat setbacks for an entire population with personalized and context aware DR based on a dynamic model of occupant thermal comfort behavior. Over 151k interactions with ecobee thermostats are analyzed to predict the impact of such personalized DR on overrides, energy curtailment magnitude, and reliability.

Kane, Michael↗

Impact Analysis of Future Electric Vehicles Using Model of Real Distribution Feeders

Globally, the number of electric vehicles (EVs) continues to increase. This on-going trend poses challenges for power distribution systems. The inclusion of electric vehicle supply equipment (EVSE) should be compatible with a changing energy system, whose structure is becoming increasingly distributed. The impact of future EVs should be analyzed and considered in the system planning and upgrades. In this study, impact analysis of future EVs is conducted for a utility company of U.S. West Coast. Real data of distribution feeders is converted into the GridLAB-D model for running power flow analysis. An estimation of the additional loading of EVs in 2050 is provided by the utility company. Simple mitigation methods are tested to improve voltage profiles and complete this case study.

Xie, Jing↗

Security assessment and impact analysis of cyberattacks in integrated T&D power systems

In this paper, we examine the impact of cyberattacks in an integrated transmission and distribution (T&D) power grid model with distributed energy resource (DER) integration. We adopt the OCTAVE Allegro methodology to identify critical system assets, enumerate potential threats, analyze and prioritize risks for threat scenarios. Based on the analysis, attack strategies and exploitation scenarios are identified which could lead to system compromise. Specifically, we investigate the impact of data integrity attacks in inverted-based solar PV controllers, control signal blocking attacks in protective switches and breakers, and coordinated monitoring and switching time-delay attacks. Index Terms—Cyberattacks, security assessment, impact analysis, case studies, integrated power systems.

14 SOLAR ENERGY↗

CO 2 conversion to syngas via electrification of endothermal reactors: Process design and environmental impact analysis

CO 2 utilization via reverse water gas shift (rWGS) reaction has been proposed as a path to the sustainable utilization. Here this work presents a detailed process modelling study where steam methane reforming (SMR) generated hydrogen was combined with rWGS to produce syngas (CO + H 2 ) with various hydrogen-to-carbon oxide ratios. To further decrease CO 2 emissions that may offset the benefits of CO 2 converted in rWGS, electrification of endothermal reactors, both SMR and rWGS was considered where CO 2 emitting fuel burning in the furnace was replaced by the emerging ohmic (resistive) heating. Material and energy inventory obtained from process design calculations was used to perform Life Cycle Analysis (LCA) to calculate environmental impacts of CO 2 consumption and reactor electrification. The results showed that greenhouse gas emissions, in CO 2 kg equivalent, were the lowest when both SMR and rWGS were heated using wind-generated electricity, decreasing from 25 to 10 kg CO 2 equivalent for H 2 :CO = 2:1 while the conventional electricity mix used for furnace electrical heating across the board of scenarios generated highest environmental impacts, much higher than those that used natural gas as fuel. Process economics calculations suggested that, when both SMR and rWGS were electrically heated, the process only showed product syngas cost parity with the conventional fuel heated design when electricity cost was ~$0.008/kWh. This suggests that CO 2 utilization scenarios involving process electrification need to be carefully considered from the total design perspective so they do not produce more greenhouse gases than in conventional non-electrified scenarios.

42 ENGINEERING↗

Grid impact analysis using controller-hardware-in-the-loop for high-power vehicle charging stations

A controller-hardware-in-the-loop (CHIL) architecture for the evaluation of grid impacts arising from high-power vehicle charging stations is presented in this paper. Unlike simulation-based studies, the proposed method can be used to capture the interactions of the grid and the charging load along with charger controllers in real time. The proposed method can be used to evaluate the impact of charging load on the grid in terms of voltage variations and line congestion. The proposed CHIL platform allows for de-risking the vehicle charging station deployment by simulating the complex interactions among all the components of a vehicle charging station - i.e., the grid, vehicle, and charger controller - in a realistic manner before using the charging station in a grid. Further, the proposed CHIL approach can be used to evaluate the voltage regulation causalities of the vehicle charging station. Experimental results are presented in the paper to illustrate the applicability of the proposed method in a laboratory environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CEC Quest: Long Duration Energy Storage Impact Analysis Tool

SAND2025-14389O CEC Quest is a Python tool with a user interface designed to analyze the greenhouse gas impacts of long-duration energy storage projects in California. The tool automates data collection from public sources and uses an Application Programming Interface (API) to enable users to download photovoltaic resource availability, marginal operating emissions rate, and utility rate data. It guides users in inputting parameters for a battery energy storage model and uploading site electrical load data, while also prompting for relevant analysis parameters like timestep and grid limits. CEC Quest performs monthly optimization of one year of data to assess impacts on the site’s electrical bill and the grid’s greenhouse gas emissions. Finally, it conducts a lifecycle analysis to evaluate changes over a defined quantification period, with results aggregated through automated report generation. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Rosewater, David [Sandia National Lab. (SNL-CA), L↗

Distributed Solar Utility Tariff and Revenue Impact Analysis: A Guidebook for International Practitioners

Depending on a range of technical, economic, policy, regulatory, and market-related factors, the adoption of DPV may have a net positive or negative financial impact on utilities and ratepayers. This guidebook provides a methodological approach for quantifying the net financial impact of DPV on utilities (in the form of “net revenue losses”) and ratepayers (in the form of “net tariff impacts”). Written for technical staff at utilities, regulatory bodies, energy ministries, research institutes, and civil society organizations who wish to better understand the financial impacts of DPV in their jurisdiction, this guidebook can be used to inform important decisions regarding DPV compensation, tariff design, and regulatory cost allocations, among other aspects. It is focused exclusively on customer-sited DPV systems and adopts a primarily cost-based (as opposed to an equally valid value-based) perspective to understanding DPV financial impacts. The approach for calculating net revenue losses can be applied in nearly any utility jurisdiction, regardless of institutional arrangements, business models, or regulatory paradigms.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact analysis of heating electrification in US buildings with geothermal heat pumps

Few studies have investigated the impacts of large-scale deployment of geothermal heat pumps (GHPs, also called ground source heat pumps) on the electric grid. GHPs utilize the ground as a heat source to warm buildings more efficiently than other space-heating systems. The coupling with the ground offers seasonal thermal storage so that GHPs can also cool buildings in summer more efficiently than other space-cooling systems. This study simulated the performance of GHP systems for various commercial and residential buildings in 15 climate zones in the United States. Combined with the latest End-Use Load Profiles of the US building stock and grid modeling, this study aims to assess the impacts of a national deployment of GHP systems on the US electric grid in terms of energy consumption, emissions, and operational resilience. The preliminary results show that the GHP deployment can save 429 billion kWh of electricity (a 19% reduction from baseline) and reduce carbon emissions by 496 million tons per year (a 31 % reduction from baseline). A geographical view of the results indicates that retrofitting existing HVAC systems with new GHP systems can lead to further reductions in annual electricity consumption and peak electricity demand in the southern regions of the United States than in other parts of the country. On the other hand, GHP retrofits result in higher percentages of site energy savings and carbon emission reduction in the north (cold climates) than in the south (warm climates).

Liu, Xiaobing↗

Lessons Learned from AskGDR: Usage and Impact Analysis of the Geothermal Data Repository's AI Research Assistant: Preprint

In October of 2024, the Department of Energy's (DOE) Geothermal Data Repository (GDR) team officially launched AskGDR, an AI research assistant resulting from the integration of a Large Language Model (LLM) with the metadata and supporting documents associated with GDR datasets. AskGDR allows GDR users to ask deeper questions about the origin of datasets, the methods used to collect them, and the findings they help support. Using Retrieval Augmented Generation (RAG), AskGDR can be used to summarize findings spread across dozens of papers and technical reports or to extract relevant information describing a single data field. However, generative AI is experimental. The National Renewable Energy Laboratory (NREL) has been collecting metrics on AskGDR and documenting lessons learned during its deployment. This paper will outline the efficacy and impact of AskGDR through analysis of its use, operating costs, number and types of questions asked, and the quality of answers provided.

15 GEOTHERMAL ENERGY↗

Fuel Fabrication Specification Impact Analysis for NBSR LEU Conversion

As part of a national initiative to enhance nuclear security and reduce proliferation risks, significant efforts have been undertaken by the National Nuclear Security Administration Material Management and Minimization Office of Reactor Conversion Program to convert U.S. high performance research reactors (USHPRRs) from the use of highly enriched uranium (HEU) to low-enriched uranium (LEU), including the National Bureau of Standards Reactor (NBSR). The current plan is to procure LEU fuel assemblies from commercial fabricators according to fuel specifications tailored for each USHPRR. The analysis conducted at Brookhaven National Laboratory was part of an effort to identify the sources of uncertainty in the fuel specifications that may impact the performance of the NBSR core after its conversion and, in particular, to assess the range of acceptable tolerance limits from the perspective of core safety and reactor performance. Using the stochastic neutronics code MCNP 6.2, the variations in important NBSR neutronics characteristics were analyzed as a function of the specification parameters independently and in combination. The important NBSR specification parameters analyzed were the fuel isotopic composition, the amount of impurity content in cladding, the fuel plate thickness, and the fuel element 235U mass loading. The range of variation of each specification parameter was based on the technical specification limit or available as-fabricated assay data and uncertainties. The NBSR neutronics characteristics selected for analysis were the reactor reactivity characteristics at equilibrium and the equilibrium fuel cycle length. Results show that with variations in the fabrication parameters of the as-fabricated U-10Mo fuel within the specification limitations, the excess reactivity of the NBSR LEU core remains well below the 15% Δk/k technical specification limit, and the shutdown margin is always significantly greater than the required 0.68% Δk/k. This ensures that the NBSR can be operated safely and reliably shut down for all analyzed cases within the specified fabrication limits after the LEU conversion. In the prototypic case, the fuel cycle length was 1.5 days longer than the targeted 38.5 days. In a credible worst-case scenario, where all low-reactivity parameters were combined, the fuel cycle length was reduced to 35.5 days, which is still considered manageable for reactor operations. Variations in cycle length are primarily driven by changes in 235U loading, with other parameters having secondary effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impacts Analysis of Amendments to Mexico's Unit Commitment and Dispatch Rules

In Mexico, there are various amendments, approved and under discussion to significantly modify the order in which generation units are committed and dispatched. This report quantifies the potential impacts on Mexico's power system, utilizing a production cost model of the Mexican power system that analyzes the hourly optimal electricity dispatch of the Mexican electricity system for 1 year under four scenarios, a reference scenario, and three alternative scenarios. These scenarios are meant to evaluate the potential impacts of increasing participation of the state-owned power plants in generation mix, electricity production costs, emissions, and renewable curtailment.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Model Advancements to Enable Impact Analysis of Climate Change on Streamflow Temperature

With support from the Department of Energy’s Water Power Technologies Office, Pacific Northwest National Laboratory (PNNL) has developed new tools that incorporate cutting-edge climate and hydrological science capabilities to assess the potential long-term impacts of future climate conditions on unregulated streamflow and water temperature within watershed-river-reservoir systems. The objectives of this project were achieved by enhancing key hydrologic and hydrodynamic models and transferring them to a high-performance computing environment to provide a high-spatiotemporal resolution, multi-scale modeling framework. The new modeling framework has the potential to quantify risks related climate change impacts on runoff, unregulated streamflow, and water temperature. Initial development and demonstration of the modeling framework was conducted under historical and future climate conditions in the Columbia River Basin in the Pacific Northwest and the Connecticut River Basin in New England.

13 HYDRO ENERGY↗