Search NASASearch

SEARCH · Search NASA

Results for “impedance response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Identifying Potential Sub-Synchronous Oscillations Using Impedance Scan Approach: Preprint

This paper presents an impedance scan study on the real-world power system in Australia that has observed 17 to 20 Hz intermittent subsynchronous oscillations. Through the impedance scan of each of the IBRs, both individually and collectively, potential resonance modes are identified. The impedance scans were carried out using electromagnetic transient PSCAD models of the network. The network comprises of site-specific, black-boxed models of IBRs supplied by the generators. The impedance scan approach was divided in three major steps: (1) the first step is to identify IBRs where impedance analysis needs to be performed based on the magnitude of oscillations observed at their points of interconnection (POIs); (2) the second step focuses on performing impedance scans at selected IBRs in single-machine infinite-bus (SMIB) configuration to identify internal resonance modes of an IBR and to evaluate if any of these modes become unstable under certain grid conditions; (3) the third step performs impedance scans at a few selected IBRs while connected to the wider network model to obtain the impedance response of both the IBR and the grid - this step evaluates control interactions among IBRs. The impedance scan study found that a few IBRs have an underdamped resonance mode at around 17 Hz, which becomes unstable under a certain operating condition. Another interesting finding was that certain IBRs increase the effective grid impedance seen by another IBR in proximity for a particular operating condition. Under this operating condition, the resulting subsynchronous oscillation mode is more pronounced due to a combination of control interactions among IBRs through the transmission network under study and a resonance mode inside the IBRs.

control interactions

Exceptional Electrical Detection of Trace NO 2 via Mixed Metal MOF-on-MOF Film-Based Sensors

The tunability of metal–organic frameworks (MOFs) makes them exceptional materials for the development of highly selective, low-power sensors for toxic gas detection. Herein, we demonstrate enhanced detection of NO 2 gas by a MOF-based electrical impedance sensor made using a unique mixed metal MOF-on-MOF synthesis. For this work, a combined experimental and computational study was performed using the exemplar Ni x Mg 1–x -MOF-74 to understand the fundamental structure–property relationships behind metal mixing and MOF film synthesis methods on sensor performance. Density functional theory results indicated that the presence of Ni in Mg-MOF-74 increased framework stability and increased the electron density of states at lower energies near the HOMO, as well as enhanced the NO 2 –Mg adsorption interaction. Impedance data of the Ni x Mg 1–x -MOF-74 films with larger Ni contents showed greater impedance change after exposure to 1 ppm of NO 2 gas. Furthermore, when synthesized through either a drop-cast or direct solvothermal film growth approach, the monometallic Ni-based sensors had the best performance. However, the mixed metal Ni x Mg 1–x -MOF-74 sensors synthesized through a MOF-on-MOF approach resulted in the highest impedance change, outperforming all monometallic Ni-based sensors. In particular, the mixed metal Ni-on-Mg-MOF-74 film was the best-performing sensor with an impedance change of 309 upon trace NO 2 exposure. Change in impedance response after NO 2 exposure was improved by 52% compared to the best monometallic Ni-on-Ni-MOF-74 sensor. Structural analysis of the Ni-on-Mg film showed that the first Mg-MOF-74 layer acts as a structural template controlling the structural features of the final film after metal exchange with Ni. This led to improved film quality, evidenced by the greater crystallinity and larger MOF grain sizes, and resulted in enhanced sensor performance which was not achievable through other metal mixing methods. Altogether, this study identifies structure–property relationships and synthetic templating methods that inform MOF-based sensor design, allowing for improved detection of toxic compounds.

36 MATERIALS SCIENCE

Electric-field enhanced water-dissociation catalysis on oxide surfaces

Ion-transfer reactions in the presence of electric fields are ubiquitous in (bio/electro)chemical systems and catalysis, yet the impact of the electric field is poorly understood. Here, we use bipolar membranes (BPMs) to isolate electric-field-driven non-faradaic water dissociation (WD: H 2 O → H + + OH − ) on catalytic surfaces. We find the catalyst layer's ionic properties dictate both the transport and kinetic processes within the BPM. The role of these properties are explored via a series of membrane architectures, and catalyst poisoning experiments, and the corresponding current–voltage and impedance responses. Arrhenius analyses show that an acidic graphene-oxide (GO x ) catalyst layer gives rise to low interfacial H 2 O entropy in the heterojunction, illustrated via a >100 fold increase in the Arrhenius prefactor relative to baseline TiO 2 measurements. Furthermore, ∼50% of the applied driving force goes towards reducing the apparent enthalpic activation barrier in the case of GO x , while other metal-oxide catalysts have enthalpic barriers independent of driving force. This analysis demonstrates a new mechanistic understanding of WD, where local electric fields augment enthalpic transition-state barriers, and the local ionic environment facilitates field-driven ion transfer. Ultimately, these results present a new design space for designing ion-transfer catalytic processes, and ionic heterojunctions more broadly.

Nathan Stovall, T. [University of California, Berk

Degradation science: Integrating modeling and experiments to predict localized corrosion processes (Annual Progress Report)

Additively manufactured (AM) eutectic high-entropy alloys (EHEAs), such as nano-lamellar AlCoCrFeNi 2.1 , have excellent strength, ductility, and wear resistance even at elevated temperatures, but their corrosion behavior in aggressive acids at different length scales remain poorly understood. This work investigates the corrosion behavior of laser powder bed–fused (L-PBF) AlCoCrFeNi 2.1 as a function of annealing temperatures, probing degradation mechanisms from nanoscopic to macroscopic length scales. The alloy is dual phase consisting of a ductile FCC L1 2 phase and a high-strength BCC B2 phase. Rapid solidification during L-PBF produces a far-from-equilibrium nano-lamellar structure with nearly homogeneous elemental distribution, which tends to evolve upon annealing toward Cr/Co/Fe-enriched FCC and Al/Ni-enriched B2. Three conditions were studied: as-printed, 600 °C/5 h, and 1000 °C/1 h, over which B2 lamellae coarsen, lamellar spacing increases, and elemental segregation becomes more prominent. Microstructure and chemistry were characterized by scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS), while in-situ electrochemical atomic force microscopy (EC-AFM) was used to link early (<5 h) local dissolution to microstructure after exposure in sulfuric acid. EC-AFM highlights preferential dissolution of the BCC/B2 phase where the surrounding matrix is Cr-depleted and directly quantifies the dissolution rates within individual phases, tracks the transition from early nano-scale attack to partial repassivation, to correlate height differences with current and impedance responses. To monitor longer-term behavior (up to 96 h), ex-situ AFM, SEM, and confocal imaging were combined with conventional bulk electrochemical tests, bridging nanoscale observations to micro/meso-scale damage morphologies. At the meso-scale, the deepest dissolution channels align with the build-direction lamellae and melt-pool boundaries, indicating that printing directionality guides the propagation of these localized corrosion sites. Annealing modifies corrosion by restructuring BCC/FCC phase fractions, lamellar spacing, and Cr/Al segregation, thereby changing the cathode/anode ratio and passive film stability. The results clarify how as-printed and annealed nano-lamellar architectures differ in their susceptibility to selective dissolution; how elemental segregation competes with residual stresses along the build direction. With these insights, future work will use CALPHAD-guided alloy modification to stabilize higher Cr contents in the B2 phase while retaining a dominant FCC+B2/BCC microstructure, with the goal of designing mechanically robust, corrosion-resistant EHEAs for safety-critical applications to leverage the LLNL’s broader national and global security mission.

36 MATERIALS SCIENCE

Prelithiated SiO x /Graphite-NMC811 Cells: Capacity Loss, Impedance Rise and Hidden Degradation Pathways Revealed Using Three-Electrode Diagnostics

Electrodes containing SiO x /graphite (Gr) materials are attractive as anodes for high-energy lithium-ion batteries. However, their mechanical deformation, electrochemical response, and impedance evolution during long-term cycling are strongly coupled, complicating accurate diagnosis of performance fade mechanisms. In this work, the behavior of electrochemically prelithiated SiO x /Gr anodes paired with NMC811 cathodes is systematically investigated using techniques that include in-situ dilatometry, three-electrode electrochemistry, and multiscale post-cycling microscopy. The SiO x /Gr electrode exhibits a maximum expansion of 49% upon lithiation to 10 mV vs Li + /Li, with 84% of the expansion and 91% of the capacity being reversible. In full cells, relatively stable cycling with only 12% capacity fade over 500 cycles is observed. Three-electrode experiments reveal cell-level impedance growth, which is dominated by the NMC811 cathode: the SiO x /Gr anode exhibits minimal net impedance rise and an initial impedance decrease at low potentials. Despite this apparent electrochemical stability, cross-sectional SEM, PFIB tomography, and cryo-STEM reveal irreversible anode thickening caused by the accumulation of an inorganic-rich solid electrolyte interphase (SEI) permeating the anode bulk. Electrode potential-shift analysis further demonstrates that Li + ions released from lithium reservoirs in the prelithiated anode mask true lithium inventory loss during aging. These results demonstrate that low-expansion SiO x /Gr anodes can simultaneously exhibit favorable cycling and impedance metrics while undergoing substantial, hidden degradation, underscoring the importance of electrode-resolved diagnostics for evaluating prelithiated silicon-based anodes.

25 ENERGY STORAGE

Multibody for Everybody (M4E) - A Linearization Approach to Enable Frequency Domain Analysis, Time Integration and Control Co-Design

1.1 Background/Objectives: Marine energy represents a promising yet underexploited source of power. To increase the harvested power, significant efforts have been made to improve wave energy converter (WEC) modeling capabilities and optimize power take-off (PTO) performance; however, these efforts have often treated WEC dynamics, PTO design, and controller development sequentially. In contrast, control co-design (CCD) is emerging as a promising strategy to address these issues directly, creating a growing need for fast analysis tools suitable for repeated simulation and parametric studies [1]. To support this need, this work presents the Multibody for Everybody (M4E) [2] linearization module, which employs a symbolic toolbox to provide deeper insight of WEC design parameters. The objective is to demonstrate that a minimal-coordinate linearization of articulated WEC dynamics can provide accurate wave response predictions and substantial computational savings relative to nonlinear time-domain simulation, while preserving compatibility with broader wave-energy analysis workflows, enabling CCD. 1.2 Approach/Activities: The proposed approach linearizes the equations of motion, generated by M4E, in minimal coordinates about a selected operating point and combines the resulting system with frequencydomain hydrodynamic terms to incorporate the reduced mass, damping, stiffness, and forcing operators. The linearized model is used for both impedance-based response amplitude operator (RAO) prediction and rapid regular-wave time integration. The methodology is demonstrated on a single-flap device and a FOSWEC configuration, with linearized M4E responses compared against the corresponding nonlinear M4E simulations and WEC-Sim results. Regular-wave time histories, RAO trends, and runtime differences are assessed. The framework is also compatible with broader wave-energy workflows, including coupling to WecOptTool, although that capability is not the focus of this work [3]. 1.3 Results/Lessons: The linearized M4E model reproduces key regularwave response characteristics such as integration and Response Amplitude over multiple frequencies. This module matches nonlinear M4E and WEC-Sim results while substantially reducing integration cost. Thus, the proposed framework can serve as a rapid analysis layer for articulated WEC design, parameter studies, and controls-oriented workflows. The analysis is most appropriate in the near-equilibrium regime, about the linearization point.

16 TIDAL AND WAVE POWER

The HHV-6B U20 glycoprotein binds ULBP1, masking it from recognition by NKG2D and interfering with natural killer cell activation

Human Herpesvirus 6B (HHV-6B) impedes host immune responses by downregulating class I MHC molecules (MHC-I), hindering antigen presentation to CD8+ T cells. Downregulation of MHC-I disengages inhibitory receptors on natural killer (NK) cells, resulting in activation and killing of the target cell if NK cell activating receptors such as NKG2D have engaged stress ligands upregulated on the target cells. Previous work has shown that HHV-6B downregulates three MHC-like stress ligands MICB, ULBP1, and ULBP3, which are recognized by NKG2D. The U20 glycoprotein of the related virus HHV-6A has been implicated in the downregulation of ULBP1, but the precise mechanism remains undetermined. We set out to investigate the role of HHV-6B U20 in modulating NK cell activity. We used HHV-6B U20 expressed as a recombinant protein or transduced into target cells, as well as HHV-6B infection, to investigate binding interactions with NK cell ligands and receptors and to assess effects on NK cell activation. Small-angle X-ray scattering was used to align molecular models derived from machine-learning approaches. We demonstrate that U20 binds directly to ULBP1 with sub-micromolar affinity. Transduction of U20 decreases NKG2D binding to ULBP1 at the cell surface but does not decrease ULBP1 protein levels, either at the cell surface or in toto. HHV-6B infection and soluble U20 have the same effect. Transduction of U20 blocks NK cell activation in response to cell-surface ULBP1. Structural modeling of the U20 – ULBP1 complex indicates some similarities to the m152-RAE1γ complex.

60 APPLIED LIFE SCIENCES

Simply Fabricatable Reference Electrode for Studying Li Metal Interfaces Operando

Reference electrodes are essential for studying Li metal interfaces, yet their integration into coin cells remains challenging due to geometric constraints and assembly complexity. Here, we present a simple three-electrode coin cell design in which a thin Cu film is evaporated directly onto a trilayer PP/PE/PP separator, forming a conductive and flexible in situ current collector. The microporous Cu preserves separator porosity and pressure uniformity, avoiding artifacts introduced by wire- or mesh-type references. It is easily activated by Li plating and provides stable potentials for over 10 days in ether-based electrolytes without affecting Coulombic efficiency (>99%) or Li deposition morphology. Operando measurements using this design reveal electrode-specific impedance evolution and voltage responses otherwise obscured in two-electrode setups, uncovering a correlation between the SEI resistance and electrolyte ionic conductivity. This microporous Cu reference electrode offers a robust and accessible platform for characterizing reactive interfaces under realistic cycling conditions.

Sacci, Robert [ORNL] (ORCID:0000000200735221)

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE

Low-Cost and Portable Biosensor Based on Monitoring Impedance Changes in Aptamer-Functionalized Nanoporous Anodized Aluminum Oxide Membrane

We report a low-cost, portable biosensor composed of an aptamer-functionalized nanoporous anodic aluminum oxide (NAAO) membrane and a commercial microcontroller chip-based impedance reader suitable for electrochemical impedance spectroscopy (EIS)-based sensing. The biosensor consists of two chambers separated by an aptamer-functionalized NAAO membrane, and the impedance reader is utilized to monitor transmembrane impedance changes. The biosensor is utilized to detect amodiaquine molecules using an amodiaquine-binding aptamer (OR7)-functionalized membrane. The aptamer-functionalized membrane is exposed to different concentrations of amodiaquine molecules to characterize the sensitivity of the sensor response. The specificity of the sensor response is characterized by exposure to varying concentrations of chloroquine, which is similar in structure to amodiaquine but does not bind to the OR7 aptamer. A commercial potentiostat is also used to measure the sensor response for amodiaquine and chloroquine. The sensing response measured using both the portable impedance reader and the commercial potentiostat showed a similar dynamic response and detection threshold. The specific and sensitive sensing results for amodiaquine demonstrate the efficacy of the low-cost and portable biosensor.

60 APPLIED LIFE SCIENCES

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline-based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive-sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

current measurement

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis: Preprint

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline- based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive- sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

grid following inverter

An Impedance Humidity Sensor Based on CVD Grown WSe 2 2D Films

2D materials-based planar devices have been sought after for gas and humidity sensor applications owing to their high sensitivity due to their ultrathin nature and increased surface area. Herein, 2D WSe 2 films-based planner devices were fabricated to evaluate their performance for potential application in humidity sensors. The structure and morphology of the WSe 2 sensing films were studied by Raman spectroscopy, photoluminescence, optical microscopy, and scanning electron microscopy (SEM) techniques. The relative humidity-dependent sensing performances of the 2D WSe 2 films were evaluated using current–voltage (I–V), relative impedance, and complex total impedance (electrochemical impedance spectroscopy, EIS) techniques. This sensor showed a very stable and repeatable performance investigated over the period of 18 months. The response and recovery times of the WSe 2 -based impedance sensors were found to be 40 and 30 s, respectively. The WSe 2 sensor exhibits a 2 ± 1% minimum hysteresis at a lower humidity level (50% RH) and around 8 ± 2% maximum hysteresis at relative humidity level (70% RH). This value of hysteresis is in the acceptable range during the initial investigation of any material to explore its potential for application in humidity sensors. The density functional theory (DFT) analysis was performed with the interaction from water molecules of the WSe 2 sample for a better understanding of the sensing mechanism of devices.

2D- WSe2

Morphological Degradation of Oxygen Evolution Reaction-Electrocatalyzing Nickel Selenides at Industrially Relevant Current Densities

We investigated electrodeposited nanoparticulate nickel selenide (pre)catalysts that transform into nickel oxides/ oxyhydroxides under oxygen evolution reaction conditions in alkaline solutions. Previous studies of this transformation were conducted at lower current densities than those of industrial relevance (≥1 A cm −2 ). We used ultramicroelectrodes (UMEs) to achieve such current densities, benefiting from their small size, ensuring low absolute currents and low ohmic drop but high current densities. Morphological degradation of the catalyst material was only observed at current densities exceeding 1 A cm −2 but not for smaller ones. Using X-ray absorption, Xray photoemission spectroscopy, and X-ray diffraction, we confirmed that the degradation was accompanied by the literature-known transformation of nanoparticulate Ni 3 Se 2 (bulk)/NiSe (surface) into nickel oxyhydroxide. The transformation of the precatalyst goes along with a significant improvement in the charge transfer kinetics observed by decreasing Tafel slopes with ongoing experimental time extracted from cyclic voltammetry (CV) experiments and electrochemical impedance spectroscopy (EIS) in the high-frequency range. However, these kinetic improvements are accompanied by limitations in mass transport concluded from decreasing current responses at high overpotentials in CVs and increasing impedance in the low-frequency range of the EIS spectra after extended CV cycling. These mass transport limitations originated from morphological degradations at the UME exceeding 1 A cm −2 which we proved by applying identical location scanning electron microscopy. This has not been reported in studies that have been limited to lower current densities before. Our findings showcase how UMEs can be used to study (pre)catalysts (herein nickel selenides) under current densities of industrial relevance in the absence of ohmic drop-related ambiguities, combined with in-depth materials characterization studies, e.g., identical location microscopy and advanced spectroscopic methods. This approach enables direct evaluation and comparison of catalyst materials and thus demonstrates how to overcome long-standing limitations of electrocatalyst design and testing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Impedance Based Fixture Neutralization (FINE) Method to Replicate Field Environments in Laboratory Settings

Test article vibration test responses will vary from one test laboratory to another due to differences in shaker and fixture dynamic characteristics. This is also seen between the field and laboratory due to the differing dynamic characteristics between field assembly loading and boundary conditions compared to the laboratory configuration. This work introduces a technique called Impedance Fixture Neutralization which customizes input forces to cause consistent responses for the Device Under Test across different vibration testing conditions. The customized force neutralizes the dynamic variations between configurations for the Device Under Test. The device responses can be replicated in several situations: when using a different fixture with the same attachment points, when the test article mounting location on the fixture changes, when the force location changes, or any combination of these situations. Impedance Fixture Neutralization uses the uncoupled dynamic characteristics of the test article and excitation fixtures to customize the input thereby causing the same test article responses between two mounting configurations (either field to laboratory or two different laboratory configurations). The application of the technique is shown using an analytical model of a two-beam system and analytically using experimental FRFs from plate and frame component hardware characterization tests. In both cases a device under test is attached to two test fixtures wherein the dynamic differences in the configurations are neutralized.

Laboratory

Rotated-Droop Control for Enhanced Stability and Power Decoupling in Microgrids With Complex Line Impedances

Classical droop control in microgrids predominantly assumes inductive line impedance, which simplifies implementation but causes power coupling and steady-state errors in systems with resistive and inductive lines. This paper proposes a rotated-droop control strategy for grid-forming inverters that reformulates the power equations by incorporating the magnitude and angle of the line impedance within a rotated reference frame. This method enhances the decoupling of active and reactive power dynamics without increasing complexity or requiring communication links. A small-signal state-space model was created to capture the dynamic behavior of the system under varying impedance parameters, preserving the original droop gains by rotating the power control structure. This allows eigenvalue-based stability analysis and enhances damping and transient performance. Simulation and experimental results validated the improved power-sharing performance, faster response, and robustness of the proposed method under different impedance conditions. This approach maintains the decentralized structure of the conventional droop control while enabling greater adaptability and scalability, making it suitable for modern inverter-based microgrids with dynamic topologies.

Campo-Ossa, Daniel Dario [Univ. of Puerto Rico, Ag

Correcting impedance measurements for background parasitics to characterize circuit components in cryogenic environments

Predictable circuit response is a critical prerequisite for accurate electronic measurements. Here, we describe a powerful yet straightforward experimental method and analysis model that utilizes an affordable LCR meter in conjunction with an in situ parasitic-impedance background-correction procedure to measure the temperature-dependent impedance (magnitude and phase) of up to ten individual passive circuit elements in a single cryostat run. We show how the model unambiguously identified a ∼20× drop in capacitance for 22 μF 5XR multilayer ceramic capacitors cooled from 300 K to 360 mK in an environment with a parasitic capacitance of ∼300 pF. The same experimental procedure, based on a simple two-wire measurement, was also used to measure 10 and 22 pF thin-film capacitors and 100 MΩ thick-film resistors. The results showed that the resistor values increased by up to an order of magnitude when the devices were cooled from 300 K to 360 mK. Most importantly, we showed that the simple data-acquisition method, coupled with our analysis model, enabled the measurement of component parasitics, and effectively extended the accuracy of a commercial LCR meter beyond its manufacturer-guaranteed values for a wide range of measurement frequencies. We also showed that, in the current configuration, our simple approach is limited to a capacitance accuracy of ∼10 pF.

Carpenter, R. J. [Santa Clara Univ., Santa Clara,