At least 19 records

Integration of an Axcelis Optima HD Single Wafer High Current Implanter for p- and n-S/D Implants in an Existing Batch Implanter Production Line

This paper is focused on the integration and qualification of an Axcelis Optima HD single wafer high current spot beam implanter in an existing 200 mm production line with different types of Axcelis batch implanters for high current applications. Both the design of the beamline and the beam shape are comparable between single wafer and batch high current spot beam implanters. In contrast to the single wafer high current ribbon beam implanter, energy contamination is not a concern for the considered spot beam tool because the drift mode can be used down to energies in the 2 keV region. The most important difference between single wafer and batch high current implanters is the significantly higher dose rate and, therefore, the higher damage rate for the single wafer tool due to the different scanning architecture. The results of the integration of high dose implantations, mainly for p- and n-S/D formation, for DRAM 110 nm without pre-amorphization implantation (PAI), CMOS Logic from around 250 nm down to 90 nm without and with PAI, are presented and discussed. Dopant concentration profile analysis using SIMS was performed for different technologies and implantation conditions. The impurity activation was measured using sheet resistance and in some cases spreading resistance technique was applied. The amorphous layer thickness was measured using TEM. Finally, device data are presented in combination with dose, energy and beam current variations. The results have shown that the integration of implantation processes into crystalline structure without PAI is more complex and time consuming than implantations into amorphous layer where the damage difference due to the different dose rates is negligible.

36 MATERIALS SCIENCE↗

Comparison Between Simulated And Experimental Au-ion Profiles Implanted in nanocrystalline ceria

Radiation response of nanocrystalline ceria films deposited on a silicon substrate was investigated under a 3-MeV Au-ion irradiation at 300 K. A uniform grain growth cross the ceria films is observed and effective densification of the ceria thin films occurs during irradiation. The Au ion profiling was measured by secondary ion mass spectrometry (SIMS) and compared to the Au ion distribution predicted by the Stopping and Range of Ions in Solids (SRIM) code. It is observed that the Au-ion penetration depth is underestimated in comparison with the SIMS measurements. An overestimation of the electronic stopping power for heavy incident ions in the SRIM program may account for the discrepancies between the calculations and the SIMS experimental results. This work presents an approach to compensate the overestimation of the electronic stopping powers in the SRIM program by adjusting the nanocrystalline ceria target density to better predict the ion implantation profile.

Environmental Molecular Sciences Laboratory↗

Tunnel oxide passivated contacts formed by ion implantation for applications in silicon solar cells

Passivated contacts (poly-Si/SiO{sub x}/c-Si) doped by shallow ion implantation are an appealing technology for high efficiency silicon solar cells, especially for interdigitated back contact (IBC) solar cells where a masked ion implantation facilitates their fabrication. This paper presents a study on tunnel oxide passivated contacts formed by low-energy ion implantation into amorphous silicon (a-Si) layers and examines the influence of the ion species (P, B, or BF{sub 2}), the ion implantation dose (5 × 10{sup 14 }cm{sup −2} to 1 × 10{sup 16 }cm{sup −2}), and the subsequent high-temperature anneal (800 °C or 900 °C) on the passivation quality and junction characteristics using double-sided contacted silicon solar cells. Excellent passivation quality is achieved for n-type passivated contacts by P implantations into either intrinsic (undoped) or in-situ B-doped a-Si layers with implied open-circuit voltages (iV{sub oc}) of 725 and 720 mV, respectively. For p-type passivated contacts, BF{sub 2} implantations into intrinsic a-Si yield well passivated contacts and allow for iV{sub oc} of 690 mV, whereas implanted B gives poor passivation with iV{sub oc} of only 640 mV. While solar cells featuring in-situ B-doped selective hole contacts and selective electron contacts with P implanted into intrinsic a-Si layers achieved V{sub oc} of 690 mV and fill factor (FF) of 79.1%, selective hole contacts realized by BF{sub 2} implantation into intrinsic a-Si suffer from drastically reduced FF which is caused by a non-Ohmic Schottky contact. Finally, implanting P into in-situ B-doped a-Si layers for the purpose of overcompensation (counterdoping) allowed for solar cells with V{sub oc} of 680 mV and FF of 80.4%, providing a simplified and promising fabrication process for IBC solar cells featuring passivated contacts.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of implant loss risk factors after simultaneous guided bone regeneration: A retrospective study of 5404 dental implants

Abstract Purpose The purpose was to analyze the risk factors for implant loss after simultaneous guided bone regeneration (GBR). Materials and Methods Patients who underwent implant placement with simultaneous GBR between January 2011 and December 2018 were screened for this study. The cumulative survival rate (CSR) was calculated using the life table method. Log‐rank test and Kaplan–Meier survival estimates were used to identify potential risk factors for implant loss. The association between the investigated variables and implant loss was determined using hazard ratios (HRs) obtained from a multivariate Cox regression analysis. Results A total of 3973 patients with 5404 implants were included in this study. The CSRs of the implants at 1, 5, and 10 years were 99.6%, 98.9%, and 98.7%, respectively. Male patient (HR = 2.94, 95% CI: 1.41–6.14), periodontitis (HR = 4.26, 95% CI: 2.05–9.86), tissue‐level implants (HR = 3.02, 95% CI: 1.30–6.98), narrow implants (HR = 2.71, 95% CI: 1.12–6.57), and implant length ≤10 mm (HR = 2.91, 95% CI: 1.41–6.02) significantly increased the risk of implant loss ( p < 0.05). The risk of implant loss was significantly higher in the maxillary posterior region (HR = 2.26, 95% CI: 1.04–4.90) than in the maxillary anterior region ( p < 0.05). Compared to Straumann, Nobel (HR = 4.07, 95% CI: 1.75–9.44) and other implant systems (HR = 14.23, 95% CI: 4.32–46.85) showed a significantly higher risk of implant loss ( p < 0.05). Conclusion Male patient, periodontitis, maxillary posterior region, Nobel implant system, other implant systems, tissue‐level implants, narrow implants, and implant length ≤10 mm were considered risk factors for implant loss after simultaneous GBR.

Shen, Xiaoting↗

Determination of prescription dose for Cs-131 permanent implants using the BED formalism including resensitization correction

Purpose: The current widely used biological equivalent dose (BED) formalism for permanent implants is based on the linear-quadratic model that includes cell repair and repopulation but not resensitization (redistribution and reoxygenation). The authors propose a BED formalism that includes all the four biological effects (4Rs), and the authors propose how it can be used to calculate appropriate prescription doses for permanent implants with Cs-131. Methods: A resensitization correction was added to the BED calculation for permanent implants to account for 4Rs. Using the same BED, the prescription doses with Au-198, I-125, and Pd-103 were converted to the isoeffective Cs-131 prescription doses. The conversion factor F, ratio of the Cs-131 dose to the equivalent dose with the other reference isotope (F{sub r}: with resensitization, F{sub n}: without resensitization), was thus derived and used for actual prescription. Different values of biological parameters such as α, β, and relative biological effectiveness for different types of tumors were used for the calculation. Results: Prescription doses with I-125, Pd-103, and Au-198 ranging from 10 to 160 Gy were converted into prescription doses with Cs-131. The difference in dose conversion factors with (F{sub r}) and without (F{sub n}) resensitization was significant but varied with different isotopes and different types of tumors. The conversion factors also varied with different doses. For I-125, the average values of F{sub r}/F{sub n} were 0.51/0.46, for fast growing tumors, and 0.88/0.77 for slow growing tumors. For Pd-103, the average values of F{sub r}/F{sub n} were 1.25/1.15 for fast growing tumors, and 1.28/1.22 for slow growing tumors. For Au-198, the average values of F{sub r}/F{sub n} were 1.08/1.25 for fast growing tumors, and 1.00/1.06 for slow growing tumors. Using the biological parameters for the HeLa/C4-I cells, the averaged value of F{sub r} was 1.07/1.11 (rounded to 1.1), and the averaged value of F{sub n} was 1.75/1.18. F{sub r} of 1.1 has been applied to gynecological cancer implants with expected acute reactions and outcomes as expected based on extensive experience with permanent implants. The calculation also gave the average Cs-131 dose of 126 Gy converted from the I-125 dose of 144 Gy for prostate implants. Conclusions: Inclusion of an allowance for resensitization led to significant dose corrections for Cs-131 permanent implants, and should be applied to prescription dose calculation. The adjustment of the Cs-131 prescription doses with resensitization correction for gynecological permanent implants was consistent with clinical experience and observations. However, the Cs-131 prescription doses converted from other implant doses can be further adjusted based on new experimental results, clinical observations, and clinical outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An evaluation of the maximum tag burden for implantation of acoustic transmitters in juvenile Chinook salmon

Abstract.—The influence of a surgically implanted acoustic micro-transmitter and passive integrated transponder (PIT) tag on the growth and survival of hatchery-reared juvenile Chinook salmon was examined. Growth and survival were compared between treatment (implanted) and control fish within three fork length (FL) size groups (80-89, 90-99, and 100-109 mm). The acoustic micro-transmitter and PIT tag implanted in our study had a combined weight of 0.74 g. Weights of study fish ranged from 4.7 to 16.3 g for treatment fish and from 5.1 to 16.8 g for control fish. The burden for the combined acoustic and PIT tag experienced by implanted fish ranged from 8.8% to 15.7% for the 80-89 mm FL group, 6.0-10.9% for the 90-99 mm FL group, and 4.5-8.6% for the 100-109 mm FL group. Results indicated that growth and survival were size-dependent among implanted juvenile Chinook salmon. Significant differences in growth rate and survival were observed between treatment and control fish in the 80-89 mm FL group. Within this group, growth of fish smaller than 88.5 mm FL (tag burden > 10.0%) was negatively affected by the implantation or presence of an acoustic micro-transmitter and PIT tag. Survival of fish in the 90-99 mm FL group did not differ between treatment and control fish. However, survival of implanted fish within this size group that were smaller than 97.2 mm FL (tag burden > 7.4%) was negatively influenced. These results indicate that the burden of an acoustic micro-transmitter and PIT tag should be maintained at or below about 7.0% for studies that use hatchery-reared juvenile Chinook salmon.

54 ENVIRONMENTAL SCIENCES↗

Nucleation and growth of cobalt disilicide precipitates during in situ transmission electron microscopy implantation

The paper is aimed at getting deeper insight into the fundamental mechanisms that govern CoSi{sub 2} precipitate nucleation and growth during Co ion implantation at high temperatures (500-650 deg. C). Information about nucleation and growth of metal silicides as a function of temperature and implantation flux is provided by experiments on cobalt implantation in silicon, performed directly by in situ transmission electron microscopy. The main attention is paid to the nucleation of B-type precipitates, which dominate under ion implantation conditions. The obtained quantitative behavior of precipitate number density and size and the scaling of these values with implantation flux are discussed and rationalized in terms of analytical and simulation approaches. An atomistic model of B-type precipitate nucleation based on the first-principles calculations of relative energetic efficiency of different Co clusters is proposed.

36 MATERIALS SCIENCE↗

Impact of implanted phosphorus on the diffusivity of boron and its applicability to silicon solar cells

Boron diffusivity reduction in extrinsically doped silicon was investigated in the context of a process combination consisting of BBr{sub 3} furnace diffusion and preceding Phosphorus ion implantation. The implantation of Phosphorus leads to a substantial blocking of Boron during the subsequent Boron diffusion. First, the influences of ion implantation induced point defects as well as the initial P doping on B diffusivity were studied independently. Here, it was found that not the defects created during ion implantation but the P doping itself results in the observed B diffusion retardation. The influence of the initial P concentration was investigated in more detail by varying the P implantation dose. A secondary ion mass spectrometry (SIMS) analysis of the BSG layer after the B diffusion revealed that the B diffusion retardation is not due to potential P content in the BSG layer but rather caused by the n-type doping of the crystalline silicon itself. Based on the observations the B diffusion retardation was classified into three groups: (i) no reduction of B diffusivity, (ii) reduced B diffusivity, and (iii) blocking of the B diffusion. The retardation of B diffusion can well be explained by the phosphorus doping level resulting in a Fermi level shift and pairing of B and P ions, both reducing the B diffusivity. Besides these main influences, there are probably additional transient phenomena responsible for the blocking of boron. Those might be an interstitial transport mechanism caused by P diffusion that reduces interstitial concentration at the surface or the silicon/BSG interface shift due to oxidation during the BBr{sub 3} diffusion process. Lifetime measurements revealed that the residual (non-blocked) B leads to an increased dark saturation current density in the P doped region. Nevertheless, electrical quality is on a high level and was further increased by reducing the B dose as well as by removing the first few nanometers of the silicon surface after the BBr{sub 3} diffusion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Productivity Implantation ''PARTIAL IMPLANT''

The patterned ion implantation 'PARTIAL IMPLANT' has been developed as a productivity improvement tool. The Partial Implant can form several different ion dose areas on the wafer surface by controlling the speed of wafer moving and the stepwise rotation of twist axis. The Partial Implant system contains two implant methods. One method is 'DIVIDE PARTIAL IMPLANT', that is aimed at reducing the consumption of the wafer. The Divide Partial Implant evenly divides dose area on one wafer surface into two or three different dose part. Any dose can be selected in each area. So the consumption of the wafer for experimental implantation can be reduced. The second method is 'RING PARTIAL IMPLANT' that is aimed at improving yield by correcting electrical characteristic of devices. The Ring Partial Implant can form concentric ion dose areas. The dose of wafer external area can be selected to be within plus or minus 30% of dose of wafer central area. So the electrical characteristic of devices can be corrected by controlling dose at edge side on the wafer.

43 PARTICLE ACCELERATORS↗

Effects of high-dose hydrogen implantation on defect formation and dopant diffusion in silver implanted ZnO crystals

This work reports on the effects of a deep high-dose hydrogen ion implant on damage accumulation, defect retention, and silver diffusion in silver implanted ZnO crystals. Single-crystal ZnO samples were implanted with Ag ions in a region ∼150 nm within the surface, and some of these samples were additionally implanted with hydrogen ions to a dose of 2 × 10{sup 16 }cm{sup −2}, close to the depth ∼250 nm. Rutherford backscattering/ion channeling measurements show that crystal damage caused by Ag ion implantation and the amount of defects retained in the near surface region following post-implantation annealing were found to diminish in the case with the H implantation. On the other hand, the additional H ion implantation resulted in a reduction of substitutional Ag atoms upon post-implantation annealing. Furthermore, the presence of H also modified the diffusion properties of Ag atoms in ZnO. We discuss these findings in the context of the effects of nano-cavities on formation and annihilation of point defects as well as on impurity diffusion and trapping in ZnO crystals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The effect of metallic implants on radiation therapy in spinal tumor patients with metallic spinal implants

The aim of this study was to evaluate the effect of metallic implants on the dose calculation for radiation therapy in patients with metallic implants and to find a way to reduce the error of dose calculation. We made a phantom in which titanium implants were inserted into positions similar to the implant positions in spinal posterior/posterolateral fusion. We compared the calculated dose of the treatment planning systems with the measured dose in the treatment equipment. We used 3 kinds of computed tomography (CT) (kilovoltage CT, extended-scaled kilovoltage CT, and megavoltage CT) and 3 kinds of treatment equipment (ARTISTE, TomoTherapy Hi-Art, and Cyberknife). For measurement of doses, we used an ionization chamber and Gafchromic external beam therapy film. The absolute doses that were measured using an ionization chamber at the isocenter in the titanium phantom were on average 1.9% lower than those in the reference phantom (p = 0.002). There was no statistically significant difference according to the kinds of CT images, the treatment equipment, and the size of the targets. As the distance from the surface of the titanium implants became closer, the measured doses tended to decrease (p < 0.001), and this showed a statistically significant difference among the kinds of CT images: the effect of metallic implants was less in the megavoltage CT than in the kilovoltage CT or the extended-scaled kilovoltage CT. The error caused by the titanium implants was beyond a clinically acceptable range. To reduce the error of dose calculation, we suggest that the megavoltage CT be used for planning. In addition, it is necessary to consider the distance between the titanium implants and the targets or the organs at risk to prescribe the dose for the target and the dose constraint for the organs at risk.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effective dopant activation by susceptor-assisted microwave annealing of low energy boron implanted and phosphorus implanted silicon

Rapid processing and reduced end-of-range diffusion result from susceptor-assisted microwave (MW) annealing, making this technique an efficient processing alternative for electrically activating dopants within ion-implanted semiconductors. Sheet resistance and Hall measurements provide evidence of electrical activation. Susceptor-assisted MW annealing, of ion-implanted Si, enables more effective dopant activation and at lower temperatures than required for rapid thermal annealing (RTA). Raman spectroscopy and ion channeling analyses are used to monitor the extent of ion implantation damage and recrystallization. The presence and behavior of extended defects are monitored by cross-section transmission electron microscopy. Phosphorus implanted Si samples experience effective electrical activation upon MW annealing. On the other hand, when boron implanted Si is MW annealed, the growth of extended defects results in reduced crystalline quality that hinders the electrical activation process. Further comparison of dopant diffusion resulting from MW annealing and rapid thermal annealing is performed using secondary ion mass spectroscopy. MW annealed ion implanted samples show less end-of-range diffusion when compared to RTA samples. In particular, MW annealed P{sup +} implanted samples achieve no visible diffusion and equivalent electrical activation at a lower temperature and with a shorter time-duration of annealing compared to RTA. In this study, the peak temperature attained during annealing does not depend on the dopant species or dose, for susceptor-assisted MW annealing of ion-implanted Si.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Comparison of Ion Implantation at Room Temperature and Heated Ion Implantation on the Body Diode Degradation of Commercial 3.3 kV 4H-SiC Power MOSFETs

It has been demonstrated that basal plane dislocations (BPDs)-induced stacking faults (SFs) cause body diode degradation in commercial 4H-SiC power MOSFETs, especially with higher voltage ratings. BPDs originate from 4H-SiC boule, epi growth, and ion implantation. Considering the lower cost of ion implantation at room temperature (RT), this work investigates the potential of RT ion implantation replacing heated (HT) ion implantation by comparing the influence of both ion implantations on the body diode degradation of commercial 3.3 kV 4H-SiC power MOSFETs. We demonstrate with long-term (up to 1000 hours) forward current stress that RT implantation can keep the body diode degradation of 3.3 kV 4H-SiC power MOSFETs within the specification limits compared with HT implantation.

4H-SiC↗

The impact of low-Z and high-Z metal implants in IMRT: A Monte Carlo study of dose inaccuracies in commercial dose algorithms

Purpose: The aim of the study was to evaluate the dosimetric impact of low-Z and high-Z metallic implants on IMRT plans. Methods: Computed tomography (CT) scans of three patients were analyzed to study effects due to the presence of Titanium (low-Z), Platinum and Gold (high-Z) inserts. To eliminate artifacts in CT images, a sinogram-based metal artifact reduction algorithm was applied. IMRT dose calculations were performed on both the uncorrected and corrected images using a commercial planning system (convolution/superposition algorithm) and an in-house Monte Carlo platform. Dose differences between uncorrected and corrected datasets were computed and analyzed using gamma index (Pγ{sub <1}) and setting 2 mm and 2% as distance to agreement and dose difference criteria, respectively. Beam specific depth dose profiles across the metal were also examined. Results: Dose discrepancies between corrected and uncorrected datasets were not significant for low-Z material. High-Z materials caused under-dosage of 20%–25% in the region surrounding the metal and over dosage of 10%–15% downstream of the hardware. Gamma index test yielded Pγ{sub <1}>99% for all low-Z cases; while for high-Z cases it returned 91% < Pγ{sub <1}< 99%. Analysis of the depth dose curve of a single beam for low-Z cases revealed that, although the dose attenuation is altered inside the metal, it does not differ downstream of the insert. However, for high-Z metal implants the dose is increased up to 10%–12% around the insert. In addition, Monte Carlo method was more sensitive to the presence of metal inserts than superposition/convolution algorithm. Conclusions: The reduction in terms of dose of metal artifacts in CT images is relevant for high-Z implants. In this case, dose distribution should be calculated using Monte Carlo algorithms, given their superior accuracy in dose modeling in and around the metal. In addition, the knowledge of the composition of metal inserts improves the accuracy of the Monte Carlo dose calculation significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗