Search NASA⌕ Search

SEARCH · Search NASA

Results for “improvised explosive devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Characterization and differentiation of aluminum powders used in improvised explosive devices. Part 2: Micromorphometric method refinement and preliminary statistical analysis

Abstract Aluminum (Al) powder is commonly encountered in improvised explosive devices (IEDs) as a metallic fuel due to its availability and low cost. Although available commercially in powder form, amateur bomb‐makers also produce their own Al powder via simple methods found online. In order to provide investigative leads and forensic intelligence, it is important to evaluate not only the composition of homemade devices, but also to distinguish between the various forms of Al powder they contain. To achieve this goal, a method using automated microscopy in combination with statistical techniques has been demonstrated to have the potential to provide source discrimination and investigative leads in source attribution of Al powders in IEDs. The present research refined this method and investigated 59 industrially and amateurly produced Al powder sources with seven subsamples per source using two traditional linear discriminant analyses (LDA), one with a standard data split for training and testing, and another using leave‐one‐out cross‐validation. Averaging the classification accuracies for the two LDA‐based analyses, LDA has the ability to correctly classify 59.26%, 83.35%, and 80.69% of the samples based on their powder source, type, and production method, respectively. This classification accuracy represents a 3407%, 317%, and 61.38% increase in accuracy from random class assignment, respectively. Further, in most instances of incorrect data attribution to a particular source, the subsample has been misidentified with another sample of the same powder type or production method.

Ommen, Danica M.↗

Characterization and differentiation of aluminum powders used in improvised explosive devices – Part 1: Proof of concept of the utility of particle micromorphometry

Abstract Aluminum (Al) powders are commonly used in improvised explosive devices as metallic fuels, a component of explosive mixtures. These powders can be obtained readily from industrial‐scale and consumer products, and produced using unsophisticated “kitchen chemistry” techniques. This research demonstrates the potential of automated particle micromorphometry for comparisons between known source and questioned Al powders recovered from IEDs, as well as for insight into the method of Al powder manufacture. Al powder samples were obtained from legitimate manufacturers, and 56 samples were produced “in‐house” from Al‐containing spray paints and ball‐milled Al foils. Transmitted light microscope images of Al powder particles were acquired using an automated stage with automated z‐focus; 17 size and shape parameters were measured for all particles. Approximately 37,000–2,500,000 particles/sample were analyzed using an open‐source statistical package with customized code. Dimensionality reduction was required for processing the large datasets: eight of the 17 measured variables were selected based on inspection of the correlation matrix. Data from four subsamples from each of the 56 samples produced using “in‐house” methods were analyzed using ANOVA to assess the within‐ and between‐sample variation. High within‐sample variation was noted; however, ANOVA and post‐hoc Tukey's honestly significant difference (HSD) tests demonstrated that the between‐sample variation was substantially larger than the within‐sample variation. Each sample could be differentiated from all other samples in the test set. Future experiments will focus on ways to reduce the within‐sample variation, and additional statistical and microanalytical methods to classify sources and confidently constrain the method of Al powder manufacture.

Baldaino, JenaMarie↗

Defeat system for vehicle attached improvised explosive devices

An explosive device detection and expulsion system broadly comprising a detection subsystem for sensing an IED attached to a vehicle and an expulsion subsystem for expelling the IED from the vehicle. The detection subsystem includes a sensor for detecting an IED via an electromagnetic field change or capacitance change, vibrations, and/or heat, and a controller for activating the expulsion subsystem upon receiving a detection signal from the sensor. The expulsion subsystem includes a deployable panel configured to be attached to the vehicle and a deployable mechanism for shifting the deployable panel from an undeployed state to a deployed state so as to expel the IED from the vehicle.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Defeat system for vehicle attached improvised explosive devices

An explosive device detection and expulsion system broadly comprising a detection subsystem for sensing an IED attached to a vehicle and an expulsion subsystem for expelling the IED from the vehicle. The detection subsystem includes a sensor for detecting an IED via an electromagnetic field change or capacitance change, vibrations, and/or heat, and a controller for activating the expulsion subsystem upon receiving a detection signal from the sensor. The expulsion subsystem includes a deployable panel configured to be attached to the vehicle and a deployable mechanism for shifting the deployable panel from an undeployed state to a deployed state so as to expel the IED from the vehicle.

Hower, Brent↗

Impact of Blast Overpressure on the Pharmacokinetics of Various Antibiotics in Sprague Dawley Rats

ABSTRACT Introduction Combat injuries are complex and multimodal. Most injuries to the extremities occur because of explosive devices such as improvised explosive devices. Blast exposure dramatically increases the risk of infection in combat wounds, and there is limited available information on the best antibiotic treatments for these injuries. We previously demonstrated that mice exposed to blast displayed a delayed clearance of cefazolin from the plasma and liver; further semi-mechanistic modeling determined that cefazolin concentrations in the skin of these mice were reduced. Our objective was to investigate the effects of blast on the pharmacokinetics of antibiotics of different types used for the treatment of combat wounds in the rat model. Materials and Methods Male Sprague Dawley rats were exposed to blast overpressure followed by injection of a bolus of animal equivalent doses of an antibiotic (cefazolin, cefepime, ertapenem, or clindamycin) into the tail vein at 1-hour post-blast exposure. Blood was collected at predetermined time points via repeated sampling from the tail vein. Animals were also euthanized at predetermined time points, at which time liver, kidney, skin, and blood via cardiac puncture were collected. Antibiotic concentrations were determined by ultra-performance liquid chromatography–tandem mass spectrometry. Results Blast-exposed rats exhibited a similar rate of clearance compared to non-blasted rats in the blood, liver, kidney, and skin, which is inconsistent with the data regarding cefazolin in blast-exposed mice. Conclusions Our results in rats do not recapitulate our previous observation of delayed cefazolin clearance in mice following the blast overpressure exposure. Although using rats permitted us to collect multiple blood samples from the same animals, rats may not be a suitable model for measuring the pharmacokinetics of antibiotics following blast. The interpretation of the results may be challenging because of variation in data among rat subjects in the same sample groups.

General & Internal Medicine↗

Blast resistant vehicle seat

Disclosed are various seats for vehicles particularly military vehicles that are susceptible to attack by road-bed explosive devices such as land mines or improvised explosive devices. The seats often have rigid seat shells and may include rigid bracing for rigidly securing the seat to the chassis of the vehicle. Typically embodiments include channels and particulate media such as sand disposed in the channels. A gas distribution system is generally employed to pump a gas through the channels and in some embodiments the gas is provided at a pressure sufficient to fluidize the particulate media when an occupant is sitting on the seat.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Forward-Looking IED Detector Ground Penetrating Radar

There have been many developments of mine or metal detectors based on ground penetrating radar techniques, usually in hand-held or rover-mounted devices. In most mine or metal detector applications, conditions are in a stationary mode and detection speed is not an important factor. A novel, forward-looking, stepped-frequency ground penetrating radar (GPR) has been developed with a capability to detect improvised explosive devices (IEDs) at vehicular speeds of 15 to 20 mph (24 to 32 km/h), 10 to 20 m ahead of the vehicle, to ensure adequate time for response. The GPR system employs two horn antennas (1.7 to 2.6 GHz, 20 dBi) as transmit and receive. The detector system features a user-friendly instantaneous display on a laptop PC and is a low-power-consumption (3 W) compact system with minimal impact on vehicle operations. In practice, the whole GPR system and a laptop PC can be powered by plugging into a cigarette lighter of a vehicle. The stepped-frequency continuous-wave (CW) radar scans frequency from 1.7 to 2.6 GHz in 1,000 steps of 0.9 MHz, with the full frequency scan in 60 ms. The GPR uses a bi-static configuration with one horn antenna used as a transmitter and the other used as a receiver so that isolation between transmitter and receiver is improved. Since the horn antennas (20 dBi) are mounted on the roof of a vehicle at a shallow inclination angle (15 to 25 with respect to horizontal), there is a first-order reduction in ground reflection so that a significant amount of the total reflected power received by the GPR comes from the scattering of RF energy off of buried objects. The stepped-frequency technique works by transmitting a tone at a particular frequency, while the received signal is mixed with the transmitted tone. As a result, the output of the mixer produces a signal that indicates the strength of the received signal and the extent to which it is in phase or out of phase with the transmitted tone. By taking measurements of the phase relationship between the transmitted and received signals over a wide frequency range, an interference pattern is produced showing all target reflections. When a Fourier transform is performed on this pattern, the result is a time-domain representation of targets. Among the advantages of this technique over impulse radar is the ability to transmit and receive much more total energy, and to use non-damped, highly focused horn antennas. The novelty of the IED detector GPR has been achieved by miniaturization of GPR electronics (single electronics board, 10x5x2 cm), low power consumption (3 W), faster signal processing capability, and minimal impact on vehicle operations.

Kim, Soon Sam↗

Iraq/Afghanistan war lung injury reflects burn pits exposure

This descriptive case series retrospectively reviewed medical records from thirty-one previously healthy, war-fighting veterans who self-reported exposure to airborne hazards while serving in Iraq and Afghanistan between 2003 and the present. They all noted new-onset dyspnea, which began during deployment or as a military contractor. Twenty-one subjects underwent non-invasive pulmonary diagnostic testing, including maximum expiratory pressure (MEP) and impulse oscillometry (IOS). In addition, five soldiers received a lung biopsy; tissue results were compared to a previously published sample from a soldier in our Iraq Afghanistan War Lung Injury database and others in our database with similar exposures, including burn pits. We also reviewed civilian control samples (5) from the Stony Brook University database. Military personnel were referred to our International Center of Excellence in Deployment Health and Medical Geosciences, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell under the auspices of Northwell IRB: 17-0140-FIMR Feinstein Institution for Medical Research “Clinicopathologic characteristics of Iraq Afghanistan War Lung Injury.” We retrospectively examined medical records, including exposure data, radiologic imaging, and non-invasive pulmonary function testing (MGC Diagnostic Platinum Elite Plethysmograph) using the American Thoracic Society (ATS) standard interpretation based on Morgan et al., and for a limited cohort, biopsy data. Lung tissue, when available, was examined for carbonaceous particles, polycyclic aromatic hydrocarbons (Raman spectroscopy), metals, titanium connected to iron (Brookhaven National Laboratory, National Synchrotron Light Source II, Beamline 5-ID), oxidized metals, combustion temperature, inflammatory cell accumulation and fibrosis, neutrophil extracellular traps, Sirius red, Prussian Blue, as well as polarizable crystals/particulate matter/dust. Among twenty-one previously healthy, deployable soldiers with non-invasive pulmonary diagnostic tests, post-deployment, all had severely decreased MEP values, averaging 42% predicted. These same patients concurrently demonstrated abnormal airways reactance (X5Hz) and peripheral/distal airways resistance (D5–D20%) via IOS, averaging – 1369% and 23% predicted, respectively. These tests support the concept of airways hyperresponsiveness and distal airways narrowing, respectively. Among the five soldiers biopsied, all had constrictive bronchiolitis. We detected the presence of polycyclic aromatic hydrocarbons (PAH)—which are products of incomplete combustion—in the lung tissue of all five warfighters. All also had detectable titanium and iron in the lungs. Metals were all oxidized, supporting the concept of inhaling burned metals. Combustion temperature was consistent with that of burned petrol rather than higher temperatures noted with cigarettes. All were nonsmokers. Neutrophil extracellular traps were reported in two biopsies. Compared to our prior biopsies in our Middle East deployment database, these histopathologic results are similar, since all database biopsies have constrictive bronchiolitis, one has lung fibrosis with titanium bound to iron in fixed mathematical ratios of 1:7 and demonstrated polarizable crystals. These results, particularly constrictive bronchiolitis and polarizable crystals, support the prior data of King et al. (N. Engl. J. Med. 365:222–230, 2011) Soldiers in this cohort deployed to Iraq and Afghanistan since 2003, with exposure to airborne hazards, including sandstorms, burn pits, and improvised explosive devices, are at high risk for developing chronic clinical respiratory problems, including: (1) reduction in respiratory muscle strength; (2) airways hyperresponsiveness; and (3) distal airway narrowing, which may be associated with histopathologic evidence of lung damage, reflecting inhalation of burned particles from burn pits along with particulate matter/dust. Non-invasive pulmonary diagnostic tests are a predictor of burn pit-induced lung injury

36 MATERIALS SCIENCE↗

Verification and Validation of Simulation Framework for Analysis of Traumatic Brain Injury

Many U.S. troops deployed in Iraq and Afghanistan have suffered blast-related, closed-head injuries as a result of being within non-lethal distance of a detonated improvised explosive device (IED). Consequently, we are conducting a modeling & simulation investigation, coupled with clinical diagnostics of brain injury, into the mechanisms associated with blast to the human head that give rise to traumatic brain injury (TBI). In particular, we are attempting to identify the specific conditions of focused stress wave energy within the brain, resulting from blast loading to the head, which define a threshold for persistent brain injury. As these threshold injury conditions are identified, one can then employ a modeling & simulation toolset to assess the efficacy of various helmet designs to mitigate blast exposure that would otherwise lead to traumatic brain injury. In this report, we describe our efforts to establish the role of stress wave interactions in the genesis of traumatic brain injury (TBI) from exposure to explosive blast. We discuss our effort to correlate simulation predictions with clinical assessments of TBI subjects whose brain injuries have been diagnosed by advanced magnetic resonance imaging techniques. This work has been funded through the U.S. Naval Health Research Center, Office of Naval Research, Mr. James Mackiewicz, project funding manager.

59 BASIC BIOLOGICAL SCIENCES↗

Stingray Case Study

Improvised explosive devices (IEDs) have injured and killed numerous soldiers and civilians as a consequence of military operations in the Middle East. With gaps in existing technologies, the US military required devices for quickly addressing deadly IEDs without harming military personnel or inflicting severe damage to the environment. In response to this need, Sandia developed Stingray, a clear, plastic handheld device to quickly and safely disable threatening IEDs. Stingray is designed to be used in two configurations: a coherent water blade for cutting operations and as a water slug for general device disruption. Prior to disabling an IED, Explosive Ordnance Disposal (EOD) technicians will x-ray the target using tools such as Sandia's X-ray Toolkit (XTK) to determine which function operators should use to dismantle the IED. For example, if the operator knows exactly which wires to cut, they can use the precision water blade. If the operator wants to create a general disruption, they can use the water slug function.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Exposure Levels for Chemical Threat Compounds; Information to Facilitate Chemical Incident Response

Exposure Standards, Limits and Guidelines for Chemical Threat Compunds ABSTRACT Exposure criteria for chemical warfare (CW) agents and certain toxic industrial chemicals (TICs) used as CW agents (such as chlorine fill in an improvised explosive device) have been developed for protection of the civilian general public, civilian employees in chemical agent processing facilities and deployed military populations. In addition, compound-specific concentrations have been developed to serve as how clean is clean enough clearance criteria guiding facility recovery following chemical terrorist or other hazardous release events. Such criteria are also useful to verify compound absence, identify containment boundaries and expedite facility recovery following chemical threat release. There is no single right value or concentration appropriate for all chemical hazard control applications. It is acknowledged that locating and comparing the many sources of CW agent and TIC exposure criteria has not been previously well-defined. This paper summarizes many of these estimates and assembles critical documentation regarding their derivation and use.

chemical terrorist↗

Robots Save Soldiers' Lives Overseas (MarcBot)

Marshall Space Flight Center mobile communications platform designs for future lunar missions led to improvements to fleets of tactical robots now being deployed by U.S. Army. The Multi-function Agile Remote Control Robot (MARCbot) helps soldiers search out and identify improvised explosive devices. NASA used the MARCbots to test its mobile communications platform, and in working with it, made the robot faster while adding capabilities -- upgrading to a digital camera, encrypting the controllers and video transmission, as well as increasing the range and adding communications abilities. They also simplified the design, providing more plug-and-play sensors and replacing some of the complex electronics with more trouble-free, low-cost components. Applied Geo Technology, a tribally-owned corporation in Choctaw, Mississippi, was given the task of manufacturing the modified robots. The company is now producing 40 units per month, 300 of which have already been deployed overseas.

Source record↗

Leveraging Game Consoles for the Delivery of TBI Rehabilitation

Military personnel are at a greater risk for traumatic brain injury (TBI) than the civilian population. In addition, the increase in exposure to explosives, i.e. , improvised explosive devices, in the Afghanistan and Iraq wars, along with more effective body armor, has resulted in far more surviving casualties suffering from TBI than in previous wars. This effort presents the results of a feasibility study and early prototype of a brain injury rehabilitation delivery system (BIRDS). BIRDS is designed to provide medical personnel treating TBI with a capability to prescribe game activities for patients to execute using a commercially available game console, either in a clinical setting or in their homes. These therapeutic activities will contribute to recovery or remediation of the patients' cognitive dysfunctions. Solutions such as this that provide new applications for existing platforms have significant potential to address the growing incidence of TBI today.

Super, Taryn↗

Data Farming and Defense Applications

.Data farm,ing uses simulation modeling, high performance computing, experimental design and analysis to examine questions of interest with large possibility spaces. This methodology allows for the examination of whole landscapes of potential outcomes and provides the capability of executing enough experiments so that outliers might be captured and examined for insights. It can be used to conduct sensitivity studies, to support validation and verification of models, to iteratively optimize outputs using heuristic search and discovery, and as an aid to decision-makers in understanding complex relationships of factors. In this paper we describe efforts at the Naval Postgraduate School in developing these new and emerging tools. We also discuss data farming in the context of application to questions inherent in military decision-making. The particular application we illustrate here is social network modeling to support the countering of improvised explosive devices.

Horne, Gary↗

Near-Infrared Photon-Counting Camera for High-Sensitivity Observations

The dark current of a transferred-electron photocathode with an InGaAs absorber, responsive over the 0.9-to-1.7- micron range, must be reduced to an ultralow level suitable for low signal spectral astrophysical measurements by lowering the temperature of the sensor incorporating the cathode. However, photocathode quantum efficiency (QE) is known to reduce to zero at such low temperatures. Moreover, it has not been demonstrated that the target dark current can be reached at any temperature using existing photocathodes. Changes in the transferred-electron photocathode epistructure (with an In- GaAs absorber lattice-matched to InP and exhibiting responsivity over the 0.9- to-1.7- m range) and fabrication processes were developed and implemented that resulted in a demonstrated >13x reduction in dark current at -40 C while retaining >95% of the approximately equal to 25% saturated room-temperature QE. Further testing at lower temperature is needed to confirm a >25 C predicted reduction in cooling required to achieve an ultralow dark-current target suitable for faint spectral astronomical observations that are not otherwise possible. This reduction in dark current makes it possible to increase the integration time of the imaging sensor, thus enabling a much higher near-infrared (NIR) sensitivity than is possible with current technology. As a result, extremely faint phenomena and NIR signals emitted from distant celestial objects can be now observed and imaged (such as the dynamics of redshifting galaxies, and spectral measurements on extra-solar planets in search of water and bio-markers) that were not previously possible. In addition, the enhanced NIR sensitivity also directly benefits other NIR imaging applications, including drug and bomb detection, stand-off detection of improvised explosive devices (IED's), Raman spectroscopy and microscopy for life/physical science applications, and semiconductor product defect detection.

Jurkovic, Michael↗