Search NASASearch

SEARCH · Search NASA

Results for “indium tin oxide”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

High Temperature - Thin Film Strain Gages Based on Alloys of Indium Tin Oxide

A stable, high temperature strain gage based on reactively sputtered indium tin oxide (ITO) was demonstrated at temperatures up to 1050 C. These strain sensors exhibited relatively large, negative gage factors at room temperature and their piezoresistive response was both linear and reproducible when strained up to 700 micro-in/in. When cycled between compression and tension, these sensors also showed very little hysteresis, indicating excellent mechanical stability. Thin film strain gages based on selected ITO alloys withstood more than 50,000 strain cycles of +/- 500 micro-in/in during 180 hours of testing in air at 1000 C, with minimal drift at temperature. Drift rates as low as 0.0009%/hr at 1000 C were observed for ITO films that were annealed in nitrogen at 700 C prior to strain testing. These results compare favorably with state of the art 10 micro-m thick PdCr films deposited by NASA, where drift rates of 0.047%/hr at 1050 C were observed. Nitrogen annealing not only produced the lowest drift rates to date, but also produce the largest dynamic gage factors (G = 23.5). These wide bandgap, semiconductor strain sensors also exhibited moderately low temperature coefficients of resistance (TCR) at temperatures up to 1100 C, when tested in a nitrogen ambient. A TCR of +230 ppm/C over the temperature range 200 C < T < 500 C and a TCR of -469 ppm/C over the temperature range 600 C < T < 1100 C was observed for the films tested in nitrogen. However, the resistivity behavior changed considerably when the same films were tested in oxygen ambients. A TCR of -1560 ppm/C was obtained over the temperature range of 200 C < T < 1100 C. When similar films were protected with an overcoat or when ITO films were prepared with higher oxygen contents in the plasma, two distinct TCR's were observed. At T < 800 C, a linear TCR of -210 ppm/C was observed and at T > 800 C, a linear TCR of -2170 DDm/C was observed. The combination of a moderately low TCR and a relatively large gage factor make these semiconducting oxide films promising candidates for the active strain elements in high temperature thin film strain gages, particularly in applications where static strain measurement is desired.

Otto J Gregory

Polyimide/Carbon Nanotube Composite Films for Electrostatic Charge Mitigation

Low color, space environmentally durable polymeric films with sufficient electrical conductivity to mitigate electrostatic charge (ESC) build-up have potential applications on large, deployable, ultra-light weight Gossamer spacecraft as thin film membranes on antennas, solar sails, thermal/optical coatings, multi-layer insulation blankets, etc.. The challenge has been to develop a method to impart robust electrical conductivity into these materials without increasing solar absorptivity (alpha ) or decreasing optical transparency or film flexibility. Since these spacecraft will require significant compaction prior to launch, the film portion of the spacecraft will require folding. The state-of-the-art clear, conductive coating (e.g. indium-tin-oxide, ITO) is brittle and cannot tolerate folding. In this report, doping a polymer with single-walled carbon nanotubes (SWNTs) using two different methods afforded materials with good flexibility and surface conductivities in the range sufficient for ESC mitigation. A coating method afforded materials with minimal effects on the mechanical, optical, and thermo-optical properties as compared to dispersal of SWNTs in the matrix. The chemistry and physical properties of these nanocomposites are discussed.

Smith, Joseph G., Jr.

Radiation-Resistant Ti/BN Coatings: Insights From 171 Days Exposure to Space Radiation and Atomic Oxygen in Low Orbit

Atmospheric Plasma Spray (APS) and Vacuum Plasma Spray (VPS) techniques were used to develop Ti/2 vol.% hBN coatings, for extreme space environments and tested aboard the International Space Station as part of the MISSE-17 (Materials International Space Station Experiments) program. The coatings were exposed to atomic oxygen, space radiation, and low-orbit thermal cycling. VPS coatings showed a 56% increase in microhardness, a 26% rise in elastic modulus, minimal porosity and crack density changes compared to APS coatings. The change in mechanical properties is attributed to the formation of TiO, TiO₂ and TiN from nitrogen retention, alongside radiation-induced dislocations, which enhanced surface hardening. The oxidation of titanium led to the formation of TiO and TiO₂, while boron nitride was retained and underwent transmutation in VPS coatings. XPS and EDS analyses confirmed the enhanced space-environment resistance of VPS coatings, making them ideal for long-term spacecraft protection in lunar and Martian conditions.

Abhijith Kunneparambil Sukumaran

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters

X-Ray Absorption Spectroscopy in High Temperature Oxidation of Metals and Alloys

An experimental technique is described that allows for the joint study of the kinetics and of the oxide structure during the high temperature oxidation of metal surfaces. Oxygen is supplied at the metal through an electrochemical oxygen pump and the oxygen pressure, at the metal surface, is measured during oxidation by a YSZ (yttria stabilized zirconia) oxygen sensor. XAS (x-ray absorption spectroscopy) is performed in fluorescence mode at the cation K edge and after each oxidation step. An appropriate analysis of the XAS spectra could provide information on both the oxidation kinetics and oxide structure. Experimental data on the high temperature oxidation of nickel, cobalt, and Fe(64%)Ni(36%) alloy, at low oxygen pressure, are reported and analyzed according to the proposed data reduction. These results indicate the presented technique to be particularly suitable for studying the hot corrosion of oxide film too thick for common surface spectroscopy (AUGER, ESCA) and too thin for conventional thermogravimetric technique.

Daniele Gozzi

A High Temperature Cyclic Oxidation Data Base for Selected Materials Tested at NASA Glenn Research Center

The cyclic oxidation test results for some 1000 high temperature commercial and experimental alloys have been collected in an EXCEL database. This database represents over thirty years of research at NASA Glenn Research Center in Cleveland, Ohio. The data is in the form of a series of runs of specific weight change versus time values for a set of samples tested at a given temperature, cycle time, and exposure time. Included on each run is a set of embedded plots of the critical data. The nature of the data is discussed along with analysis of the cyclic oxidation process. In addition examples are given as to how a set of results can be analyzed. The data is assembled on a read-only compact disk which is available on request from Materials Durability Branch, NASA Glenn Research Center, Cleveland, Ohio.

Scale Spalling Models

Multikilowatt hydrogen-nickel oxide battery system

The potential of the H2-NiO battery for terrestrial applications was assessed. A multicell design approach that differs significantly from the aerospace individual pressure vessel was used. A number of experimental 100-Ah cells were built to evaluate the new design concepts and components. The experimental cells provided the input needed for a multicell battery design. It is found that new multicell H2-NiO battery has a number of potential advantages for aerospace applications such as the manned space station. The advantages are discussed, and a design concept is presented for a multikilowatt battery in a lightweight pressure vessel.

Dunlop, J. D.