Search NASA⌕ Search

SEARCH · Search NASA

Results for “industrial sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

NETL's Cost of Capturing CO2 from Industrial Sources and Industrial Carbon Capture Retrofit Database

This presentation was given on behalf of NETL's Strategic Systems Analysis and Engineering Directorate, Energy Process Analysis Team at a United States Energy Association webinar on January 24, 2023. The presentation summarizes techno economic analysis results of nine industrial CO2 capture cases, and also gave an overview and brief demonstration of the industrial sources Carbon Capture Retrofit Database, which is a publicly available tool that estimates capture costs for a subset of the industrial sources appearing in the companion systems analysis report.

Hughes, Sydney↗

Cost of Capturing CO 2 from Industrial Sources

This systems analysis by the National Energy Technology Laboratory's Strategic Systems Analysis and Engineering directorate) evaluates the cost and performance impacts of capturing CO 2 emissions from nine industrial sources (ammonia, ethylene oxide, and ethanol production, natural gas process, coal- and gas-to-liquids, refinery hydrogen production, iron and steel, and cement manufacturing). The industrial sectors examined are segregated according to the CO 2 purity level of the flue gas stream, prior to treatment. Certain sectors naturally produce a gas stream that is inherently high in CO 2 purity, and these sectors can achieve 99-100% removal. Other sectors produce a lower purity CO 2 flue gas stream and achieving 90-99% removal requires deeper levels of treatment, adding cost. In addition to the report that documents the analysis, a Carbon Capture Retrofit Database tool was also created that allows users to apply CO 2 capture to selected industries, to evaluate the cost of capture and compare across multiple plants, as well as across different industries. Users have the ability to change select input parameters (such as fuel price, capture rate, and financing assumptions) to evaluate the impact on industrial CO 2 capture economics.

20 FOSSIL-FUELED POWER PLANTS↗

Integrating an Industrial Source and Commercial Algae Farm with Innovative CO 2 Transfer Membrane and Improved Strain Technologies

This report describes the overall findings of the research project “Integrating an Industrial Source and Commercial Algae Farm with Innovative CO 2 Transfer Membrane and Improved Strain Technologies”. The motivation and goal for this project were to increase the carbon utilization efficiency (CUE) and areal productivity for algal cultivations, thereby reducing CO 2 costs to cultivation operations and improving economics. This was achieved through a combination of enhanced delivery of inorganic carbon and improved strains of Nannochloropsis oceanica capable of higher rates of bicarbonate uptake and metabolism. The project succeeded in these goals. First, a bubble-free, membrane-based technology was developed for delivering CO 2 to cultivations, which increased the CUE from the 15-20% that is standard in the industry to more than 65%. In addition, N. oceanica was modified to express a bicarbonate transporter protein, BicA, which enabled the cells to grow more quickly. In addition, advances were made in the protein engineering of carbonic anhydrase (CA) for enhanced stability and catalytic performance, the computational fluid dynamics modeling of algal cultivation systems, and in the life-cycle assessment and technoeconomic analysis of algal production. Together, these outcomes contribute to advancing algal cultivation as an economically viable platform for production of fuels, materials, and other chemical products. The project results aid in addressing the dual challenges of reducing atmospheric CO 2 levels and achieving green energy solutions.

09 BIOMASS FUELS↗

Pinned Clouds over Industrial Sources of Heat during TRACER

An analysis of stereo-camera data from the Tracking Aerosol Convection Interactions Experiment (TRACER) campaign in Houston, Texas, reveals the existence of pinned clouds sitting atop industrial heat sources. These are not plumes of vapor and condensate emanating from stacks: The pinned shallow cumuli have cloud bases at about the lifting condensation of near-surface air. On many mornings, the pinned clouds are the only shallow cumuli in the field of view of the stereo cameras, persisting by themselves for at least an hour. On those mornings, the lower atmosphere straddles the boundary between stable and unstable, and the waste heat from industrial facilities is able to pin moist convection overhead. When solar heating of the surface becomes sufficient later in the morning, those mornings transition to having widespread shallow moist convection. Occurring within the field of view of the stereo cameras and other TRACER instruments, these pinned clouds represent steady plume-like moist convection triggered by known heat sources in a well-characterized atmosphere, making them a rich target for further study. Significance Statement This article introduces steady-state cumulus clouds observed during the Tracking Aerosol Convection Interactions Experiment (TRACER) campaign that were pinned to industrial heat sources. These pinned clouds were present in the early morning only when conditions were primed for moist convection, but for which there was not yet enough solar heating to trigger widespread convection. They persist in a statistical steady state and therefore provide a natural setting to explore the mechanisms controlling convective dynamics, which play a central role in Earth’s atmospheric circulation and radiative balance.

Atmosphere↗

Cost of Capturing CO 2 from Industrial Sources

The objective of this study is to provide an estimate of the cost to capture carbon dioxide (CO 2 ) from select industrial processes (ammonia, ethylene oxide, ethanol, natural gas processing, coal-to-liquids, gas-to-liquids, refinery hydrogen, cement, iron/steel, and pulp/paper). Each of the ten processes were chosen for analysis due to either the high purity of the CO 2 emission source (99–100 mole percent CO 2 ) or the large quantity of CO 2 potentially available. For each industrial process considered, available plant information, such as existing average plant size, projected new development plant size, or existing plant operations data was used to develop a reference plant for this study.

20 FOSSIL-FUELED POWER PLANTS↗

Immobilization of Uranium in a Wetland 8-km Downstream from an Industrial Source (Report)

A three-day walk-over survey with portable gamma detecting equipment was conducted over a uranium-contaminated wetland located 8-km downstream from a former fuel fabrication facility. 97,000 spectra were collected, individually processed to extract uranium activity data, and then integrated with topographical information (LIDAR) to create maps. These maps reveal that 50 years after being released into the environment, 11% of the uranium is retained in the 9-ha wetland area. Combined with measurement collected closer to the source, it was determined that 94% of the released uranium is presently being held in downstream wetlands. This demonstrates that wetlands can be very effective at immobilizing contaminants for long durations. The survey also showed that previous flyover maps overestimated the size of the contaminated areas by 140% but had the advantage of being completed in orders-of-magnitude fewer labor hours. Depending on project needs, the walk-over technique may be useful to include in tandem with flyover measurements to acquire maps with greater sensitivity and spatial resolution.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ultralightweight Power System for Human-Portable Linac-Based X-Ray Sources

Industrial human-portable X-ray sources are widely used by security, nuclear safeguard, and defense agencies. However, the employed sources have significant energy, dose, size, weight, and power (SWaP) limitations, greatly affecting their practical application. RF linear accelerators (linacs) can serve as a flexible, reliable, and robust type of X-ray source if they can match the size, weight, cost, and imaging performance requirements of conventional ones. One of the most critical elements affecting these parameters is the high-voltage pulsed power supply system or modulator, which can make the largest contribution to the total weight and dimensions of the accelerator. Here, in this article, we present the design and demonstration results of a novel ultra lightweight power system based on a 24-kV solid-state Marx modulator for a hand-portable 0.15–2.0-MeV Ku -band linac-based X-ray source.

47 OTHER INSTRUMENTATION↗

Roughrider Carbon Storage Hub (Final Report)

The Roughrider Carbon Storage Hub was a 2-year project (October 2023 – September 2025) conducted by the Energy & Environmental Research Center (EERC) focused on advancing the feasibility of a commercial-scale carbon dioxide (CO 2 ) geologic storage hub in McKenzie County, North Dakota. The project’s objective was to investigate the potential that stacked storage complexes (multiple deep saline formations) can safely and economically store at least 50 million tonnes of CO 2 within 30 years. The captured CO 2 would be sourced from industrial emitters including project partner ONEOK, Inc.’s gas-processing plants and a planned gas-to-liquids facility. Drilling of the Roughrider 1 stratigraphic test well (14,979-ft total depth) was completed in November 2024. The wellbore intersected four candidate storage formations: Inyan Kara, Broom Creek, Mission Canyon, and Black Island–Deadwood. Operational challenges, including a stuck drill string, were resolved without long-term impact. A comprehensive logging and coring program was conducted, followed by successful well abandonment and site reclamation. Over 660 ft of 4-in. whole core was retrieved. Core plug samples were processed and analyzed for petrophysical and geochemical properties. Results confirmed promising porosity and permeability in the Inyan Kara and Broom Creek Formations and removal of the Mission Canyon and Black Island–Deadwood horizons from further investigation. Data derived from the logging and coring program were used to improve initial geologic models built from legacy data. CO 2 injection simulations showed that the Inyan Kara alone can feasibly store the target mass of CO 2 . Because of subtle differences in geologic structure and porosity trends between the formations, a stacked storage scenario using the Broom Creek and Inyan Kara Formations resulted in a larger overall plume area than using the Inyan Kara alone. Preliminary CO 2 pipeline routes from the industrial sources were mapped utilizing existing rights of way and evaluated for capacity and cost using U.S. Department of Energy Office of Fossil Energy and Carbon Management/National Energy Technology Laboratory models and U.S. Environmental Protection Agency emissions data. Integrating capture, transport, and storage cost estimates with policy incentives (e.g., 45Q credits) provided a total cost-per-ton analysis. Results indicate that the small scale of the volumes to be transported over the cumulative large distances does not support the project’s financial viability. However, the groundwork laid during this project from geological, regulatory, and social perspectives positions the Roughrider hub site as a promising candidate for commercial carbon storage in North Dakota, especially if the economy of scale is introduced for CO 2 transportation to the hub site.

01 COAL, LIGNITE, AND PEAT↗

NETL's Carbon Capture Retrofit Databases

This PowerPoint presentation summarizes the recently published Carbon Capture Retrofit Databases and their supporting documents, such as user guides and studies used to inform cost and performance estimates. NETL publications used to develop slide contents include Cost of Capturing CO2 from Industrial Sources, 2022; Industrial CCRD, 2022; Eliminating the Derate of Carbon Capture Retrofits, 2023; PC CCRD, 2023; Cost and Performance of Retrofitting NGCC Units for Carbon Capture, 2023; and NGCC CCRD, 2023.

Hughes, Sydney↗

Progression to Compatibility Evaluations in Flowing Molten Salts

Molten salt compatibility with structural alloys has been identified as a key issue for the development of Generation 3 concentrating solar power (CSP) systems with thermal storage. To accelerate this evaluation to pumped systems, the goal of this project was to conduct thermal convection loop (TCL) experiments with a peak temperature of ≥700°C and a typical temperature gradient of ~100°C. The experiments indicated that conventional ~16wt.%Cr Ni-based alloys are compatible up to 700°C with purified (i.e. low O) or dried (low H₂O) industrial-sourced Mg-K-Na chloride salt with <10 μm/yr loss. This two-year project was conducted based on the experimental and mechanistic understanding developed more than 60 years ago at Oak Ridge National Laboratory (ORNL). The first TCL experiment met the <15 μm/yr corrosion metric for this project with specimens of Ni-based alloy 600 exposed at 580°-700°C for 1000 h and post-exposure room temperature tensile tests showed minimal degradation. The second TCL experiment successfully deployed an electrochemical sensor from Argonne National Laboratory and had a peak temperature of 750°C but only ran for ~110 h due to a furnace failure. Both experiments used highly purified industrial-sourced salt with an O content of ~3 μg O/g salt and a Mg addition of 0.04 wt.%. In the second year, the Chloride Collective developed a more economical drying procedure such that the O content was much higher (>20,000 μg O/g salt). A third TCL experiment was conducted with a sensor and a peak temperature of 700°C using dried salt from the same industrial source and increased NaCl content (~20 wt.%). In addition to a 0.05% Mg addition to the salt, a Mg coupon was added in the coldest part of the loop which dissolved during the experiment. Again, small mass changes were noted for specimens of alloys 600 and C276 but the values were slightly higher than those measured in purified salt with Mg. A thin non-continuous and non-adherent oxide layer was deposited on most specimens containing Mg, Si and Al but Cr depletion also was observed. Both years included facilities qualification crucible experiments and then capsule experiments to confirm a baseline isothermal reaction rate. The first year capsule experiment led to the conclusion that the two-stage ORNL purification process using NH₄Cl and CCl₄ left the salt with a high Cl potential and a Mg addition (~0.05wt.%) was needed to lower the potential. The second year capsule experiments at 600° and 700°C found little difference in depth of attack for 0-0.25%Mg additions. In general, the complex reactions where salt can be trapped in the porous surface layer of metal indicated that mass change is an unreliable metric and average depth of Cr depletion is a better metric for assessing the extent of attack. These results have created a new baseline that is contrary to the recent published literature for chloride salts where mass losses have been reported that can be extrapolated to very significant annual metal loss rates. Chloride salt corrosion can be controlled and the results also indicate that salt purification to low O levels may not be necessary. However, additional TCL experiments are needed at different times and temperatures to generate important engineering information such as temperature dependent corrosion rates and reaction rate laws for extrapolation to long-term behavior and isolate the effect of salt additives and impurities.

36 MATERIALS SCIENCE↗

User Guide for the Public Industrial CO2 Capture Retrofit Database Models

OBSOLETE CCRD – SUPERSEDED<p>The National Energy Technology Laboratory (NETL) user manual accompanies the carbon capture retrofit database (CCRD) model that allows users to evaluate the cost of carbon capture on industrial sources (ammonia, cement, ethanol, hydrogen, and natural gas processing). The model was created by the National Energy Technology Laboratory (NETL) based on the technical report titled &quot;Cost of Capturing CO2 from Industrial Sources&quot; (NETL/DOE-2022/3319). Revised 12/21/22.</p>

Hughes, Sydney↗

Industrial CO2 Capture Retrofit Database (IND CCRD)

OBSOLETE CCRD - SUPERSEDED<p>This carbon capture retrofit database (CCRD) model allows users to evaluate the cost of carbon capture on industrial sources (ammonia, cement, ethanol, hydrogen, and natural gas processing). The model was created by the National Energy Technology Laboratory (NETL) based on the technical report titled Cost of Capturing CO2 from Industrial Sources (NETL/DOE-2022/3319). Revised 12/21/22.</p>

Hughes, Sydney↗

Security of Mobile Radiological Sources: Overview of Industry Applied Technologies

Small radiological sources used in industrial settings recurrently require transit between job sites. Securing these sources, while stationary, can be addressed with standard security approaches and equipment. Transport of these sources increases the risk and complexity of managing and maintaining control of these sources. Implementing methodologies to securely monitor and locate sources improves response and resolution of anomalous events during transit. The Mobile Source Transit Security (MSTS) system was developed to improve security and provide situational awareness of these mobile sources throughout their job cycle. The MSTS development effort focused on creating a set of systems that could be successfully implemented in industrial radiography and well-logging applications. The MSTS team worked to address source presence and location through use and storage. The MSTS system monitors radiological sources as they move from the base of operations to the job site and back. The system provides near-real-time monitoring of the mobile source location and status and early notification of source loss or theft by transmitting operational status and alerting anomalous conditions over telematic links worldwide. The MSTS system can trigger an armed response or initiation of search and recovery operations and will automatically alert management and responsible staff if a radioactive source is lost or stolen whether it is on-site, in transport, or in storage.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Energy-efficient carbon capture from industrial point sources via commercially available green solvent and hollow fiber membrane contactors

Solvent-based absorption systems have emerged in the carbon capture space due to their high absorption capacities, reusability, and favorable energy requirements. Using diethyl sebacate as a solvent for pre- and post-combustion carbon capture has advantages over other solvents, including high hydrophobicity, low viscosity, low vapor pressure, high CO 2 solubility, high CO 2 selectivity, and being commercially available in large quantities. Despite these advantageous properties, the use of diethyl sebacate as a solvent for post-combustion carbon capture has not been studied in detail. To examine the capability of diethyl sebacate, a scalable, energy-efficient, hollow fiber membrane (microporous polypropylene and polyvinylidene fluoride) contactor (HFMC)-based process with low-cost and high surface area is investigated. A purity of 95.3 % CO 2 with 46 % recovery in one absorption stage was achieved, with a permeate flux over one magnitude greater than using a deep eutectic solvent in the same system. Technoeconomic analysis determined a ∼ 0.8 GJ per ton of CO 2 at a processing cost of ∼$93 per ton of CO 2 . Results from this work underscore the potential for utilizing green solvents in HFMC-based separation processes for effective carbon capture and provide a pathway towards practical deployment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetron R&D for high efficiency CW RF sources for industrial accelerators

The scheme of using high-efficiency magnetrons to drive radiofrequency accelerators has been demonstrated at 2450 MHz in CW mode *. Magnetron test stands at JLab and GA have been set up to further test the noise figure and the locking speed of the injection phase-lock method. For higher power applications, power combining experiments using a TM010 cavity-type combiner and a magic tee for the binary combiner while using a single clean injection signal has been carried out at 2450 MHz. The frequency pulling effect between the magnetron and a low-Q cavity has been shown to enhance the frequency locking bandwidth compared to the injection phase-lock alone. The principle has been studied by the equivalent circuit simulation, analytical model, and finally confirmed experimentally on the magnetrons. Due to the pandemic delay in 2020, the equivalent high power tests using a 75kW, 915MHz industrial magnetron will be done in 2021 and will be reported in a future paper.

Wang, H.↗

Magnetron R&D Progress for High Efficiency CW RF Sources of Industrial Accelerators

After the demonstration of using high efficiency magnetron power to combine and aim to drive a radio frequency accelerator at 2450MHz in CW mode [1], we have used trim coils adding to a water-cooled magnetron and three amplitude modulation methods in an open-loop control to further suppress the 120Hz side-band noise to -46.7dBc level. We have also successfully demonstrated the phase-locking to an industrial grade cooking magnetron transmitter at 915MHz with a 75kW CW power delivered to a water load by using a -26.6dBc injection signal. The sideband noise at 360Hz from the 3-Phase SCRs DC power supply can be reduced to -16.2dBc level. Their power combing scheme and higher power application to industrial accelerators are foreseeing.

Wang, H.↗