Graphical methods for the sensitivity analysis in discriminant analysis

Similar to regression, many measures to detect influential data points in discriminant analysis have been developed. Many follow similar principles as the diagnostic measures used in linear regression in the context of discriminant analysis. Here we focus on the impact on the predicted classification posterior probability when a data point is omitted. The new method is intuitive and easily interpretative compared to existing methods. We also propose a graphical display to show the individual movement of the posterior probability of other data points when a specific data point is omitted. This enables the summaries to capture the overall pattern of the change.

97 MATHEMATICS AND COMPUTING↗

Influence of low concentrations of scatterers and signal detection time on the results of their measurements using dynamic light scattering

The influence of limited detection time on the form of the autocorrelation function (ACF) has been analysed for measurements in low-concentration suspensions by dynamic light scattering with allowance for the spatial distribution of the laser beam intensity. The general view of the ACF of the scattered light intensity is obtained for a Gaussian beam and a finite measurement time. The results of the theoretical analysis are compared with the experimental data and the results obtained by computer simulation of the scattering from an ensemble of particles involved in Brownian motion in a Gaussian beam. It is shown that, in the case of low suspension concentrations, the ACF distortions related to finite detection time lead to underestimation of the particle sizes and occurrence of an artefact peak in the distribution of the scattered light intensity over scatterer sizes. An empirical dependence of the measured size of particles on their number in the scattering volume is found. (light scattering)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of bleeder cloth impressions on the use of polar backscatter to detect porosity

The influence of the nature of the composite's surface on ultrasonic polar backscatter measurements for detecting and characterizing porosity in composite laminates is studied, focusing on the effects of bleeder cloth impressions noted by Bar-Cohen (1987). The results indicate that the presence of the bleeder cloth impressions substantially influences the degree of anisotropy. It is found that, for relatively thin samples in which selective time gating is not feasible, the state of the insonified surface and the state of the back surface both influence the received signal.

Handley, S. M.↗

Quantitative Measurements of Nitric Oxide Concentration in High-Pressure, Swirl-Stabilized Spray Flames

Lean direct-injection (LDI) spray flames offer the possibility of reducing NO(sub x) emissions from gas turbines by rapid mixing of the liquid fuel and air so as to drive the flame structure toward partially-premixed conditions. We consider the technical approaches required to utilize laser-induced fluorescence methods for quantitatively measuring NO concentrations in high-pressure LDI spray flames. In the progression from atmospheric to high-pressure measurements, the LIF method requires a shift from the saturated to the linear regime of fluorescence measurements. As such, we discuss quantitative, spatially resolved laser-saturated fluorescence (LSF), linear laser-induced fluorescence (LIF), and planar laser-induced fluorescence (PLIF) measurements of NO concentration in LDI spray flames. Spatially-resolved LIF measurements of NO concentration (ppm) are reported for preheated, LDI spray flames at pressures of two to five atmospheres. The spray is produced by a hollow-cone, pressure-atomized nozzle supplied with liquid heptane. NO is excited via the Q(sub 2)(26.5) transition of the gamma(0,0) band. Detection is performed in a two nanometer region centered on the gamma(0,1) band. A complete scheme is developed by which quantitative NO concentrations in high-pressure LDI spray flames can be measured by applying linear LIF. NO is doped into the reactants and convected through the flame with no apparent destruction, thus allowing a NO fluorescence calibration to be taken inside the flame environment. The in-situ calibration scheme is validated by comparisons to a reference flame. Quantitative NO profiles are presented and analyzed so as to better understand the operation of lean-direct injectors for gas turbine combustors. Moreover, parametric studies are provided for variations in pressure, air-preheat temperature, and equivalence ratio. Similar parametric studies are performed for lean, premixed-prevaporized flames to permit comparisons to those for LDI flames. Finally, PLIF is expanded to high pressure in an effort to quantify the detected fluorescence image for LDI flames. Success is achieved by correcting the PLIF calibration via a single-point LIF measurement. This procedure removes the influence of any preferential background that occurs in the PLIF detection window. In general, both the LIF and PLIF measurements verify that the LDI strategy could be used to reduce NO(sub x) emissions in future gas turbine combustors.

Cooper, Clayton S.↗

Electronic Tongue for Quantitation of Contaminants in Water

An assembly of sensors, denoted an electronic tongue, is undergoing development as a prototype of compact devices for use in measuring concentrations of contaminants in water. Thus far, the electronic tongue has been tested on ions of Cu, Zn, Pb, and Fe and shown to respond to concentrations as low as about 10 parts per million. This electronic tongue is expected to be capable of measuring concentrations of other metal ions and organic compounds. Potential uses for electronic tongues include monitoring the chemical quality of water in a variety of natural, industrial, and laboratory settings; detecting micro-organisms indirectly by measuring microbially influenced corrosion; and characterizing compounds of interest to the pharmaceutical and food industries. This version of the electronic tongue includes a heater, a temperature sensor, an array of ion-specific electrodes, an oxidation/ reduction sensor pair, an electrical-conductivity sensor, and an array of galvanic cells, all on one compact ceramic substrate. Special-purpose electronic excitation and readout circuitry for the sensors has also been constructed. The main advantage of the electronic tongue, relative to electrodes of this type used traditionally to assess water quality, is extreme ruggedness. The types of measurements that can be performed by use of the sensors on the electronic tongue are quite varied. The best combination of types of measurements for a given application depends on the specific contaminants that one seeks to detect. Experimental studies to identify such combinations were in progress at the time of reporting the information for this article.

Buehler, Marlin↗

Evaluating and modeling the effects of surface sampling factors on the recovery of organic chemical attribution signatures using the accelerated diffusion sampler and solvent extraction

In this study, an experimental design matrix was created and executed in order to test the effects of various real-world factors on the ability of the (1) accelerated diffusion sampler with solid phase micro-extraction (ADS-SPME) and (2) solvent extraction to capture organic chemical attribution signatures (CAS) from dimethyl methylphosphonate (DMMP) spiked onto painted wall board (PWB) surfaces. The DMMP CAS organic impurities sampled by ADS-SPME and solvent extraction were analyzed by gas chromatography/mass spectrometry (GC/MS). The number of detected DMMP CAS impurities and their respective GC/MS peak areas were determined as a function of DMMP stock, DMMP spiked volume, exposure time, SPME sampling time, and ADS headspace pressure. Based on the statistical analysis of experimental results, several general conclusions are made: (1) ADS-SPME with vacuum (i.e., reduced pressure) increased the amount of detected CAS impurity, as measured by GC/MS peak area, by a factor of 1.7 to 1.9 for PWB under certain experimental conditions, (2) the amount of detected CAS impurity was most influenced by spiked volume, stock, and ADS headspace pressure, (3) the ADS had no measurable effect on the number of detected DMMP impurities, that is, the ADS (with and without reduced pressure) had no practical effect on the DMMP impurity profile collected from spiked PWB, and (4) solvent extraction out performed ADS-SPME in terms of consistently capturing all or most of the targeted DMMP impurities from spiked PWB.

36 MATERIALS SCIENCE↗

Electronic Tongue Containing Redox and Conductivity Sensors

The Electronic Tongue (E-tongue 2) is an assembly of sensors for measuring concentrations of metal ions and possibly other contaminants in water. Potential uses for electronic tongues include monitoring the chemical quality of water in a variety of natural, industrial, and laboratory settings, and detecting micro-organisms indirectly by measuring microbially influenced corrosion. The device includes a heater, a temperature sensor, an oxidation/reduction (redox) sensor pair, an electrical sensor, an array of eight galvanic cells, and eight ion-specific electrodes.

Buehler, Martin↗

An Extension to the Kalman Filter for an Improved Detection of Unknown Behavior

The use of Kalman filter (KF) interferes with fault detection algorithms based on the residual between estimated and measured variables, since the measured values are used to update the estimates. This feedback results in the estimates being pulled closer to the measured values, influencing the residuals in the process. Here we present a fault detection scheme for systems that are being tracked by a KF. Our approach combines an open-loop prediction over an adaptive window and an information-based measure of the deviation of the Kalman estimate from the prediction to improve fault detection.

Benazera, Emmanuel↗

Effect of air on energy and rise-time spectra measured by proportional gas counter

Air exerts a negative effect on radiation detection using a gas counter because oxygen contained in air has a high electron attachment coefficient and can trap electrons from electron-ion pairs created by ionization from incident radiation in counting gas. This reduces radiation counts. The present study examined the influence of air on energy and rise-time spectra measurements using a proportional gas counter. In addition, a decompression procedure method was proposed to reduce the influence of air and its effectiveness was investigated. For the decompression procedure, the counting gas inside the gas counter was decompressed below atmospheric pressure before radiation detection. For the spectrum measurement, methane as well as various methane and air mixtures were used as the counting gas to determine the effect of air on energy and rise-time spectra. Results showed that the decompression procedure was effective for reducing or eliminating the influence of air on spectra measurement using a proportional gas counter. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fault detection of helicopter gearboxes using the multi-valued influence matrix method

In this paper we investigate the effectiveness of a pattern classifying fault detection system that is designed to cope with the variability of fault signatures inherent in helicopter gearboxes. For detection, the measurements are monitored on-line and flagged upon the detection of abnormalities, so that they can be attributed to a faulty or normal case. As such, the detection system is composed of two components, a quantization matrix to flag the measurements, and a multi-valued influence matrix (MVIM) that represents the behavior of measurements during normal operation and at fault instances. Both the quantization matrix and influence matrix are tuned during a training session so as to minimize the error in detection. To demonstrate the effectiveness of this detection system, it was applied to vibration measurements collected from a helicopter gearbox during normal operation and at various fault instances. The results indicate that the MVIM method provides excellent results when the full range of faults effects on the measurements are included in the training set.

Chin, Hsinyung↗

Evaluation of a frequency-dependent phase shift in chirped Raman lasers for atom gravimeters

Light-pulse atom gravimetry has emerged as a powerful technique for precisely measuring absolute gravitational acceleration. Raman lasers are commonly used in this technique to coherently manipulate the atomic wave packet, of which the effective frequency is chirped continuously to compensate for the Doppler shift. In this study we investigate an additional phase shift in the Raman lasers that arises due to the frequency chirp. Here, we directly measure this phase shift by recording the beat signal of the Raman lasers with a high-speed oscilloscope, providing an independent evaluation of the resultant error in atom gravimeters caused by this phase shift. Concurrently, we detect the influence of the additional phase shift on gravity measurements using our atom gravimeter, and the results are in good agreement with the independent evaluation. Notably, there may still be a residual error at the microgal level when performing differential measurements by reversing the direction of the effective wave vector of the Raman lasers. We propose that this residual error can in principle be eliminated by selecting the same chirp frequency range for both directions in the differential measurement.

Xu, Yaoyao [Huazhong Univ. of Science and Technolo↗

Impact of Measurement Error on Synchrophasor Applications

Phasor measurement units (PMUs), a type of synchrophasor, are powerful diagnostic tools that can help avert catastrophic failures in the power grid. Because of this, PMU measurement errors are particularly worrisome. This report examines the internal and external factors contributing to PMU phase angle and frequency measurement errors and gives a reasonable explanation for them. It also analyzes the impact of those measurement errors on several synchrophasor applications: event location detection, oscillation detection, islanding detection, and dynamic line rating. The primary finding is that dynamic line rating is more likely to be influenced by measurement error. Other findings include the possibility of reporting nonoscillatory activity as an oscillation as the result of error, failing to detect oscillations submerged by error, and the unlikely impact of error on event location and islanding detection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Domain Reflectometry Modeling and Measurement for Nondestructive Evaluation of Nuclear Power Plant Cables

Cable insulation polymers are among the more susceptible materials to age-related degradation within a nuclear power plant. This is recognized by both regulators and utilities, so all plants have developed cable aging management programs to detect damage before critical component failure in compliance with regulatory guidelines. Although a wide range of tools are available to evaluate cables and cable systems, cable aging management programs vary in how condition monitoring and NDE is conducted as utilities search for the most reliable and cost-effective ways to assess cable system condition. Frequency domain reflectometry (FDR) is emerging as one valuable tool to locate and assess damaged portions of a cable system with minimal cost and only requires access in most cases to one of the cable terminal ends. This work examines a physics-based model of a cable system and relates it to FDR measurements for a better understanding of specific damage influences on defect detectability.

cable↗

CORONAL PROPERTIES OF THE SEYFERT 1.9 GALAXY MCG-05-23-016 DETERMINED FROM HARD X-RAY SPECTROSCOPY WITH NuSTAR

Measurements of the high-energy cut-off in the coronal continuum of active galactic nuclei have long been elusive for all but a small number of the brightest examples. We present a direct measurement of the cut-off energy in the nuclear continuum of the nearby Seyfert 1.9 galaxy MCG-05-23-016 with unprecedented precision. The high sensitivity of NuSTAR up to 79 keV allows us to clearly disentangle the spectral curvature of the primary continuum from that of its reflection component. Using a simple phenomenological model for the hard X-ray spectrum, we constrain the cut-off energy to 116{sub −5}{sup +6} keV with 90% confidence. Testing for more complex models and nuisance parameters that could potentially influence the measurement, we find that the cut-off is detected robustly. We further use simple Comptonized plasma models to provide independent constraints for both the kinetic temperature of the electrons in the corona and its optical depth. At the 90% confidence level, we find kT{sub e} = 29 ± 2 keV and τ {sub e} = 1.23 ± 0.08 assuming a slab (disk-like) geometry, and kT{sub e} = 25 ± 2 keV and τ {sub e} = 3.5 ± 0.2 assuming a spherical geometry. Both geometries are found to fit the data equally well and their two principal physical parameters are correlated in both cases. With the optical depth in the τ {sub e} ≳ 1 regime, the data are pushing the currently available theoretical models of the Comptonized plasma to the limits of their validity. Since the spectral features and variability arising from the inner accretion disk have been observed previously in MCG-05-23-016, the inferred high optical depth implies that a spherical or disk-like corona cannot be homogeneous.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast neutron background characterization with the Radiological Multi-sensor Analysis Platform (RadMAP)

In an effort to characterize the fast neutron radiation background, 16 EJ-309 liquid scintillator cells were installed in the Radiological Multi-sensor Analysis Platform (RadMAP) to collect data in the San Francisco Bay Area. Each fast neutron event was associated with specific weather metrics (pressure, temperature, absolute humidity) and GPS coordinates. Furthermore, the expected exponential dependence of the fast neutron count rate on atmospheric pressure was demonstrated and event rates were subsequently adjusted given the measured pressure at the time of detection. Pressure adjusted data was also used to investigate the influence of other environmental conditions on the neutron background rate. Using National Oceanic and Atmospheric Administration (NOAA) coastal area lidar data, an algorithm was implemented to approximate sky-view factors (the total fraction of visible sky) for points along RadMAPs route. In the three areas we analyzed, San Francisco, Downtown Oakland, and Berkeley, all demonstrated a suppression in the background rate of over 50% for the range of sky-view factors measured. This effect, which is due to the shielding of cosmic-ray produced neutrons by surrounding buildings, was comparable to the pressure influence which yielded a 32% suppression in the count rate over the range of pressures measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Heterodyne Radiometer for Sensitive Detection of CO2 and CH4

We propose to develop an inexpensive, miniaturized, passive laser heterodyne radiometer (LHR) using commercially available telecommunications laser components to measure two significant carbon cycle gases in the atmospheric column: carbon dioxide (CO2) and methane (CH4). This instrument would operate in tandem with the passive aerosol sensor currently used in AERONET (an established network of more than 450 ground aerosol monitoring instruments worldwide). Because aerosols induce a radiative effect that influences terrestrial carbon exchange, simultaneous detection of aerosols with these key carbon cycle gases offers a uniquely comprehensive measurement approach that supports the Decadal Survey. Laser heterodyne radiometry is a technique for detecting weak signals that was adapted from radio receiver technology. In a radio receiver, a weak input signal from a radio antenna is mixed with a stronger local oscillator signal. The mixed signal (beat note, or intermediate frequency) has a frequency equal to the difference between the input signal and the local oscillator. The intermediate frequency is amplified and sent to a detector that extracts the audio from the signal. In a laser heterodyne radiometer, the weak input signal is light that has undergone absorption by a trace gas. The local oscillator is a laser at a near-by frequency - in this case a low-cost distributed feedback (DFB) telecommunications laser. These two light waves are superimposed in either a beamsplitter or in a fiber coupler (as is the case in this design). The signals are mixed in the detector, and the RF beat frequency is extracted. Changes in concentration of the trace gas are realized through analyzing changes in the beat frequency amplitude. A schematic of the progression of the LHR development project is shown in the figure below. At the center (within the dashed line), light from the local oscillator is superimposed upon light that has undergone absorption by a trace gas, in a single mode fiber coupler. Superimposed light is mixed in a fast photoreceiver, and the beat signal is analyzed for changes in absorption. The left portion of the figure depicts a progression of light sources that pass through the trace gas, increasing in complexity in the downward direction. On the right side of the figure, RF signal processing progresses from a commercially available spectrum analyzer to a RF receiver, and finally to an RF filter bank to deconvolute portions of the beat frequency more heavily weighted for different altitudes.

Wilson, Emily L.↗

High Time Resolution Modelled and Measured New Particle Formation Rates During the 2023 Pittsburgh, PA Campaign

Particle size distributions are used to calculate nucleation rates during new particle formation (NPF). However, the low time resolution and poor sensitivity of instruments deployed to observe particle size distributions can lead to inaccurate estimates of nucleation rates. We calculated nucleation rates in Pittsburgh, PA from particle size distributions measured with the new high time resolution Condensation Particle Counters For Atmospheric Rapid Measurements (CPC FARM) and from gas precursor concentrations measured with a chemical ionization mass spectrometer. The CPC FARM nucleation rates were calculated by examining the appearance rate of particles in the smallest size bin at 1.6 nm. The nucleation rate of 1.6 nm determined every second resulted in positive and negative rates, indicating the influence of inhomogeneous mixing and advection of precursor gases and clusters. These effects are not currently considered when estimating nucleation rates from measurements. The nucleation rates from the CPC FARM were compared to the nucleation rates determined from a transient acid‐base reaction model using measured sulfuric acid concentration, strong base concentrations, and CPC detection efficiencies. The transient form of the model allowed the advection of heterogeneously mixed precursors to influence the nucleation rate. Good agreement between particle and gas‐based nucleation rates is observed during sulfuric acid‐driven NPF events. This study demonstrates that high time resolution measurements of short‐lived and rapidly formed particles are needed to accurately capture nucleation rates, which are likely influenced by advection of nucleation precursors and clusters in heterogeneous environments such as urban areas.

Cheng, D. [Carnegie Mellon Univ., Pittsburgh, PA (↗

Physical electronics and surface physics

Current analytical and experimental investigations of the influence of surface processes on the rate of permeation of gases through solids are summarized. A brief description is presented of an analytical model that provides an approximate prediction of the dependence of the permeation rate on the rates of surface processes relative to the rate of the diffusion process. Results of experiments indicate that the desorption process of hydrogen from various materials is influenced by surface impurities to the degree that substantial changes in the spatial distribution of the desorbed molecules are observed when the impurities are varied. Except possibly for H-Nb, the permeation measurements indicate that the desorption process is not influenced to the degree that detectable changes in the permeation rates are observed when the impurities and temperatures are varied. On the basis of analysis, it is unlikely that the desorption process will be the rate-controlling step under the conditions of the present experiments.

Stickney, R. E.↗