Search NASA⌕ Search

SEARCH · Search NASA

Results for “information spectrum method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Exponential Strong Converse for Successive Refinement with Causal Decoder Side Information

We consider the k-user successive refinement problem with causal decoder side information and derive an exponential strong converse theorem. The rate-distortion region for the problem can be derived as a straightforward extension of the two-user case by Maor and Merhav (2008). We show that for any rate-distortion tuple outside the rate-distortion region of the k-user successive refinement problem with causal decoder side information, the joint excess-distortion probability approaches one exponentially fast. Our proof follows by judiciously adapting the recently proposed strong converse technique by Oohama using the information spectrum method, the variational form of the rate-distortion region and Hölder’s inequality. The lossy source coding problem with causal decoder side information considered by El Gamal and Weissman is a special case (k = 1) of the current problem. Therefore, the exponential strong converse theorem for the El Gamal and Weissman problem follows as a corollary of our result.

42 ENGINEERING↗

SU-E-T-90: Accuracy of Calibration of Lithium-6 and -7 Enriched LiF TLDs for Neutron Measurements in High Energy Radiotherapy

Purpose: To determine the potential error involved in the interpretation of neutron measurements from medical linear accelerators (linacs) using TLD-600H and TLD-700H if standard AmBe and {sup 252}Cf neutron sources are used for calibration without proper inclusion of neutron energy spectrum information. Methods: The Kerma due to neutrons can be calculated from the energy released by various nuclear interactions (elastic and inelastic scatter, (n,α), (n,p), (n,d), (n,t), (n,2n), etc.). The response of each TLD can be considered the sum of the neutron and gamma components; each proportional to the Kerma. Using the difference between the measured TLD responses and the ratio of the calculated Kerma for each material, the neutron component of the response can be calculated. The Monte Carlo code MCNP6 has been used to calculate the neutron energy spectra resulting from photonuclear interactions in a Varian 21EX linac. TLDs have been exposed to the mixed (γ-n) field produced by a linac and AmBe and {sup 252}Cf standard neutron sources. Results: For dosimetry of neutrons from AmBe or {sup 252}Cf sources, assuming TLD-700H insensitivity to neutrons will Result in 10% or 20% overestimation of neutron doses respectively.For dosimetry of neutrons produced in a Varian 21EX, applying a calibration factor derived from a standard AmBe or {sup 252}Cf source will Result in an overestimation of neutron fluence, by as much as a factor of 47.The assumption of TLD-700H insensitivity to neutrons produced by linacs leads to a negligible error due to the extremely high Kerma ratio (600H/700H) of 3000 for the assumed neutron spectrum. Conclusion: Lithium-enriched TLDs calibrated with AmBe and/or {sup 252}Cf neutron sources are not accurate for use under the neutron energy spectrum produced by a medical linear accelerator.

60 APPLIED LIFE SCIENCES↗

Computing a Stability Spectrum by Use of the HHT

The Hilbert-Huang transform (HHT) is part of the mathematical basis of a method of calculating a stability spectrum. This method can be regarded as an extended and improved version of a prior HHT-based method of calculating a damping spectrum. In the prior method, information on positive damping (which leads to stability) and negative damping (which leads to instability) becomes mixed into a single squared damping loss factor. Hence, there is no way to distinguish between stability and instability by examining a damping spectrum. In contrast, in the present stabilityspectrum method, information on the mathematical sign of the damping is retained, making it possible to identify reThe Hilbert-Huang transform (HHT) is part of the mathematical basis of a method of calculating a stability spectrum. This method can be regarded as an extended and improved version of a prior HHT-based method of calculating a damping spectrum. In the prior method, information on positive damping (which leads to stability) and negative damping (which leads to instability) becomes mixed into a single squared damping loss factor. Hence, there is no way to distinguish between stability and instability by examining a damping spectrum. In contrast, in the present stabilityspectrum method, information on the mathematical sign of the damping is retained, making it possible to identify regions of instability in a spectrum. This method is expected to be especially useful for analyzing vibration-test data for the purpose of predicting vibrational instabilities in structures (e.g., flutter in airplane wings).

Huang, Norden E.↗

RE-CAPTURING COSMIC INFORMATION

Gravitational lensing of distant galaxies can be exploited to infer the convergence field as a function of angular position on the sky. The statistics of this field, much like that of the cosmic microwave background (CMB), can be studied to extract information about fundamental parameters in cosmology, most notably the dark energy in the universe. Unlike the CMB, the distribution of matter in the universe which determines the convergence field is highly non-Gaussian, reflecting the nonlinear processes that accompanied structure formation. Much of the cosmic information contained in the initial field is therefore unavailable to the standard power spectrum measurements. Here we propose a method for re-capturing cosmic information by using the power spectrum of a simple function of the observed (nonlinear) convergence field. We adapt the approach of Neyrinck et al. to lensing by using a modified logarithmic transform of the convergence field. The Fourier transform of the log-transformed field has modes that are nearly uncorrelated, which allows for additional cosmological information to be extracted from small-scale modes.

79 ASTRONOMY AND ASTROPHYSICS↗

Asteroid (101955) 1999 RQ36: Spectroscopy from 0.4 to 2.4 Micrometer and Meteorite Analogs

We present reflectance spectra from 0.4 to 2.4 ?m of Asteroid (101955) 1999 RQ36, the target of the OSIRIS-REx spacecraft mission. The visible spectral data were obtained at the McDonald Observatory 2.1-m telescope with the ES2 spectrograph. The infrared spectral data were obtained at the NASA Infrared Telescope Facility using the SpeX instrument. The average visible spectrum is combined with the average near-infrared wavelength spectrum to form a composite spectrum. We use three methods to constrain the compositional information in the composite spectrum of Asteroid (101955) 1999 RQ36 (hereafter RQ36). First, we perform a least-squares search for meteorite spectral analogs using 15,000 spectra from the RELAB database. Three most likely meteorite analogs are proposed based on the least-squares search. Next, six spectral parameters are measured for RQ36 and their values are compared with the ranges in parameter values of the carbonaceous chondrite meteorite classes. A most likely meteorite analog group is proposed based on the depth of overlap in parameter values. The results of the least-squares search and the parametric comparisons point to CIs and/or CMs as the most likely meteorite analogs for RQ36, and COs and CHs as the least likely. RQ36 has a spectrally blue continuum slope that is also observed in carbonaceous chondrites containing magnetite. We speculate that RQ36 is composed of a CM1 -like material. Finally, we compare RQ36 to other B-type asteroids measured by Clark et al. (Clark, B.E. et al. [2010]. J. Geophys. Res. 115, E06005). The results of this comparison are inconclusive. RQ36 is comparable to Themis spectral properties in terms of its albedo, visible spectrum, and near-infrared spectrum from 1.1 to 1.45 micrometers. However, RQ36 is more similar to Pallas in terms of its near-infrared spectrum from 1.6 to 2.3 micrometers. Thus it is possible that B-type asteroids form a spectral continuum and that RQ36 is a transitional object, spectrally intermediate between the two end-members. This is particularly interesting because Asteroid 24 Themis was recently discovered to have H2O ice on the surface (Rivkin, A., Emery, J. [2010]. Nature 464, 1322 1323; Campins, H. et al. [2010a]. Nature 464, 1320 1321).

Clark, Beth Ellen↗

Analysis and application of Fourier transform spectroscopy in atmospheric remote sensing

An analysis method for Fourier transform spectroscopy is summarized with applications to various types of distortion in atmospheric absorption spectra. This analysis method includes the fast Fourier transform method for simulating the interferometric spectrum and the nonlinear least-squares method for retrieving the information from a measured spectrum. It is shown that spectral distortions can be simulated quite well and that the correct information can be retrieved from a distorted spectrum by this analysis technique.

Park, J. H.↗

Effects of Galactic absorption on soft X-ray surveys

A bias in the spectral distribution of X-ray sources detected in X-ray surveys is discussed which is due to the combination of the intrinsic characteristics of X-ray telescopes and the effects of low-energy photoelectric absorption within the Galaxy. A statistical method for obtaining information on the average spectrum of X-ray sources detected in well-defined surveys is presented. This method can be applied to surveys performed with X-ray telescopes working at relatively soft X-ray energies, such as Einstein, Exosat, and Rosat.

Zamorani, G.↗

Investigation of air transportation technology at Ohio University, 1990-1991

The status of the Joint University Program is given. Brief synopsis of some areas of research follow. The study of spectrum efficient methods for transmitting weather information to aircraft has resulted in definition of an improved amplitude and phase modulation process which permits reutilization of voice channels for both voice and data. The system is being implemented for testing. Multisensor navigation systems introduce increased flexibility and performance for aviation, at the expense of increased complexity. Insuring a high level of system reliability and integrity requires that faults not only be detected, but also isolated to specific elements, so that the remaining capabilities of the system may be used with confidence. An algorithm was developed. The JUP has served as a vehicle for reporting work accomplished in evoked potential vision tracking experiments to determine the engineering parameters of this input and control method. Application of GPS in an interferometric mode permits accurate measurement of differential motion; aircraft attitude may be determined using GPS only, with multiple antennas.

Lilley, Robert W.↗

TTF HOM Data Analysis with Curve Fitting Method

To investigate the possibility of using HOM signals induced in SC cavities as beam and cavity diagnostics, narrow band (20 MHz) data was recorded around the strong TE111-6(6{pi}/9-like) dipole modes (1.7 GHz) in the 40 L-band (1.3 GHz) cavities at the DESY TTF facility. The analyses of these data have so far focused on using a Singular Value Decomposition (SVD) technique to correlate the signals with each other and data from conventional BPMs to show the dipole signals provide an alternate means of measuring the beam trajectory. However, these analyses do not extract the modal information (i.e., frequencies and Q's of the nearly degenerate horizontal and vertical modes). In this paper, we described a method to fit the signal frequency spectrum to obtain this information, and then use the resulting mode amplitudes and phases together with conventional BPM data to determine the mode polarizations and relative centers and tilts. Compared with the SVD analysis, this method is more physical, and can also be used to obtain the beam position and trajectory angle.

43 PARTICLE ACCELERATORS↗

Simulation of dose reduction in tomosynthesis

Purpose: Methods for simulating dose reduction are valuable tools in the work of optimizing radiographic examinations. Using such methods, clinical images can be simulated to have been collected at other, lower, dose levels without the need of additional patient exposure. A recent technology introduced to healthcare that needs optimization is tomosynthesis, where a number of low-dose projection images collected at different angles is used to reconstruct section images of an imaged object. The aim of the present work was to develop a method of simulating dose reduction for digital radiographic systems, suitable for tomosynthesis. Methods: The developed method uses information about the noise power spectrum (NPS) at the original dose level and the simulated dose level to create a noise image that is added to the original image to produce an image that has the same noise properties as an image actually collected at the simulated dose level. As the detective quantum efficiency (DQE) of digital detectors operating at the low dose levels used for tomosynthesis may show a strong dependency on the dose level, it is important that a method for simulating dose reduction for tomosynthesis takes this dependency into account. By applying an experimentally determined relationship between pixel mean and pixel variance, variations in both dose and DQE in relevant dose ranges are taken into account. Results: The developed method was tested on a chest tomosynthesis system and was shown to produce NPS of simulated dose-reduced projection images that agreed well with the NPS of images actually collected at the simulated dose level. The simulated dose reduction method was also applied to tomosynthesis examinations of an anthropomorphic chest phantom, and the obtained noise in the reconstructed section images was very similar to that of an examination actually performed at the simulated dose level. Conclusions: In conclusion, the present article describes a method for simulating dose reduction suitable for tomosynthesis. However, the method applies equally well to any digital radiographic system, although the benefits of correcting for DQE variations may be smaller.

61 RADIATION PROTECTION AND DOSIMETRY↗

System and method for structural characterization of materials by supervised machine learning-based analysis of their spectra

A method of supervised machine learning-based spectrum analysis information, using a neural network trained with spectrum information, to identify a specified feature of a given material, a system for supervised machine learning-based spectrum analysis, and a method of training a neural network to analyze spectrum data. The method of supervised machine learning-base spectrum analysis comprises inputting into the neural network spectrum data obtained from a sample of the given material; and the neural network processing the spectrum data, in accordance with the training of the neural network, and outputting one or more values for the specified feature of the sample of the material. In an embodiment, the training set of data includes x-ray absorption spectroscopy data for the given material. In an embodiment, the training set of data includes electron energy loss spectra (EELS) data.

Frenkel, Anatoly↗

Analysis method for Fourier transform spectroscopy

A fast Fourier transform technique is given for the simulation of those distortion effects in the instrument line shape of the interferometric spectrum that are due to errors in the measured interferogram. The technique is applied to analyses of atmospheric absorption spectra and laboratory spectra. It is shown that the nonlinear least squares method can retrieve the correct information from the distorted spectrum. Analyses of HF absorption spectra obtained in a laboratory and solar CO absorption spectra gathered by a balloon-borne interferometer indicate that the retrieved amount of absorbing gas is less than the correct value in most cases, if the interferogram distortion effects are not included in the analysis.

Park, J. H.↗

Rapid Monitoring and Defense Approach for Resilience Improvement of Grid Cyber Security

Cyber-physical systems and electric utilities significantly depend on the reliability and efficiency of information and operational technology. However, false data injection attacks based on synchrophasor measurement data pose a serious threat to the safe and reliable operation of modern power systems. Here, to mitigate this problem, a rapid monitoring and defense approach is proposed to defend against cyber attacks. Initially, the Time and Frequency based Convolutional neural Network (TFCN) is proposed to detect different types of attacks. Within the TFCN, the advances are that both time and frequency domain information can be fused without extra spectrum analysis methods, and can save detection time to speed the calculation efficiency using the developed time-frequency block. Next, a comprehensive defense strategy is developed for multiple cyber attacks to ensure the stability and resilience of the power system according to the feedback detection results. The advances of this strategy are that different control strategies can be automatically selected to recover the stability to the greatest extent according to the detected attacks. To verify the effectiveness of the proposed approach, the high-speed frequency measurements collected from the wide-area monitoring system are used. The results demonstrate that the cyber attack detection performance can reach 95.57% accuracy, outperforming both traditional and some advanced neural networks. Importantly, the defense strategy is conducted and verified in a modified IEEE 39 bus system as well, which illustrates profound performance in faster stability restoration.

Comprehensive defense strategy↗

Two-dimensional fourier transform spectrometer

The present invention relates to a system and methods for acquiring two-dimensional Fourier transform (2D FT) spectra. Overlap of a collinear pulse pair and probe induce a molecular response which is collected by spectral dispersion of the signal modulated probe beam. Simultaneous collection of the molecular response, pulse timing and characteristics permit real time phasing and rapid acquisition of spectra. Full spectra are acquired as a function of pulse pair timings and numerically transformed to achieve the full frequency-frequency spectrum. This method demonstrates the ability to acquire information on molecular dynamics, couplings and structure in a simple apparatus. Multi-dimensional methods can be used for diagnostic and analytical measurements in the biological, biomedical, and chemical fields.

47 OTHER INSTRUMENTATION↗

Two-dimensional fourier transform spectrometer

The present invention relates to a system and methods for acquiring two-dimensional Fourier transform (2D FT) spectra. Overlap of a collinear pulse pair and probe induce a molecular response which is collected by spectral dispersion of the signal modulated probe beam. Simultaneous collection of the molecular response, pulse timing and characteristics permit real time phasing and rapid acquisition of spectra. Full spectra are acquired as a function of pulse pair timings and numerically transformed to achieve the full frequency-frequency spectrum. This method demonstrates the ability to acquire information on molecular dynamics, couplings and structure in a simple apparatus. Multi-dimensional methods can be used for diagnostic and analytical measurements in the biological, biomedical, and chemical fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The information content of projected galaxy fields

ABSTRACT The power spectrum of the non-linearly evolved large-scale mass distribution recovers only a minority of the information available on the mass fluctuation amplitude. We investigate the recovery of this information in 2D ‘slabs’ of the mass distribution averaged over ≈100 h−1 Mpc along the line of sight, as might be obtained from photometric redshift surveys. We demonstrate a Hamiltonian Monte Carlo method to reconstruct the non-Gaussian mass distribution in slabs, under the assumption that the projected field is a point-transformed Gaussian random field, Poisson-sampled by galaxies. When applied to the Quijote N-body suite at z = 0.5 and at a transverse resolution of 2 h−1 Mpc, the method recovers ∼30 times more information than the 2D power spectrum in the well-sampled limit, recovering the Gaussian limit on information. At a more realistic galaxy sampling density of 0.01 h3 Mpc−3, shot noise reduces the information gain to a factor of 5 improvement over the power spectrum at resolutions of 4 h−1 Mpc or smaller.

79 ASTRONOMY AND ASTROPHYSICS↗

Informing solar blind radioluminescence imaging through a calibrated spectrum

While direct radiation detection methods offer great insight into the origin of ionizing particles and photons, their use to locate contaminated areas or concealed radioactive sources can lead to undue exposure of personnel and equipment to ionizing radiation or the potential for contamination. These same sources induce ultraviolet (UV) optical photon fluorescence in air – a process referred to as radioluminescence – that may be imaged from low dose regions over larger attenuation lengths than ionizing radiation. However, most optical detection methods are limited to low lighting conditions to image the more abundant ultraviolet-A (UV-A) photons. To extend this capability to room light or daytime conditions, the solar blind region (Ultraviolet-C (UV-C), <280 nm) can be tapped. Though the emission yield of UV-C photons is roughly two orders of magnitude lower than that in the UV-A regime, the UV-C offers dramatic improvements in signal-to-noise ratios under bright lighting conditions due to decreased background interferences. The yield of specific UV-C lines, if present in the literature at all, varies widely, which has a large impact in modeling and analyzing standoff UV-C measurement scenarios. Thus, we have captured improved radioluminescence spectra over 250–400 nm and identified observed emission peaks in ambient air. Many of the UV-C photons produced by ionizing radiation excitation result from high-energy, molecular nitrogen Gaydon-Herman transitions which have had limited study to date for this application. Relating these findings to published UV-A yields, we estimate emissions between 0.15–0.19 photons/MeV over 250–280 nm. Additionally, we also use a commercial corona-discharge imaging camera to demonstrate outdoor UV-C radiation mapping of alpha and gamma emitters from 50 and 75 m standoffs, respectively. The imaged “counts” are compared to optically modelled values and show the same trend over distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Origin, Composition and History of Comets from Spectroscopic Studies

A wealth of information essential to understanding the composition and physical structure of cometary ice and hence gain deep insight into the comet's origin and history, can be gleaned by carrying out a full range of spectroscopic studies on the returned sample. These studies ought to be among the first performed as they are generally non-destructive and will provide a broad data bank which will be crucial in planning subsequent analysis. Examples of the spectroscopic techniques along with relative sensitivities and transitions probed, are discussed. Different kind of "spectroscopy" is summarized, with emphasis placed on the kind of information each provides. Infrared spectroscopy should be the premier method of analysis as the mid-IR absorption spectrum of a substance contains more global information about the identity and structure of that material than any other property. In fact, the greatest strides in our understanding of the composition of interstellar ices (thought by many to be the primordial material from which comets have formed) have been taken during the past ten years or so because this was when high quality infrared spectra of the interstellar medium (ISM) first became available. The interpretation of the infrared spectra of mixtures, such as expected in comets, is often (not always) ambiguous. Consequently, a full range of other non-destructive, complementary spectroscopic measurements are required to fully characterize the material, to probe for substances for which the IR is not well suited and to lay the groundwork for future analysis. Given the likelihood that the icy component (including some of the organic and mineral phases) of the returned sample will be exceedingly complex, these techniques must be intensely developed over the next decade and then made ready to apply flawlessly to what will certainly be one of the most precious, and most challenging, samples ever analyzed.

Allamandola, L. J.↗