Search NASA⌕ Search

SEARCH · Search NASA

Results for “infrared array sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Monte Carlo Techniques for Calculations of Charge Deposition and Displacement Damage from Protons in Visible and Infrared Sensor Arrays

This slide presentation examines motivation for Monte Carlo methods, charge deposition in sensor arrays, displacement damage calculations, and future work. The discussion of charge deposition sensor arrays includes Si active pixel sensor APS arrays and LWIR HgCdTe FPAs. The discussion of displacement damage calculations includes nonionizing energy loss (NIEL), HgCdTe NIEL calculation results including variance, and implications for damage in HgCdTe detector arrays.

Marshall, Paul↗

Evolution of miniature detectors and focal plane arrays for infrared sensors

Sensors that are sensitive in the infrared spectral region have been under continuous development since the WW2 era. A quest for the military advantage of 'seeing in the dark' has pushed thermal imaging technology toward high spatial and temporal resolution for night vision equipment, fire control, search track, and seeker 'homing' guidance sensing devices. Similarly, scientific applications have pushed spectral resolution for chemical analysis, remote sensing of earth resources, and astronomical exploration applications. As a result of these developments, focal plane arrays (FPA) are now available with sufficient sensitivity for both high spatial and narrow bandwidth spectral resolution imaging over large fields of view. Such devices combined with emerging opto-electronic developments in integrated FPA data processing techniques can yield miniature sensors capable of imaging reflected sunlight in the near IR and emitted thermal energy in the Mid-wave (MWIR) and longwave (LWIR) IR spectral regions. Robotic space sensors equipped with advanced versions of these FPA's will provide high resolution 'pictures' of their surroundings, perform remote analysis of solid, liquid, and gas matter, or selectively look for 'signatures' of specific objects. Evolutionary trends and projections of future low power micro detector FPA developments for day/night operation or use in adverse viewing conditions are presented in the following test.

Watts, Louis A.↗

Cross-correlation and image alignment for multi-band IR sensors

We present the development of a cross-­‐correlation algorithm for correlating objects in the long wave, mid wave and short wave Infrared sensor arrays. The goal is to align the images in the multi-­‐ sensor suite by correlating multiple key features in the images. Due to the wavelength differences, the object appears very differently in the sensor images even the sensors focus on the same object. In order to perform accurate correlation of the same object in the multi-­‐band images, we perform image processing on the images so that the features of the object become similar to each other. Fourier domain band pass filters are used to enhance the images. Mexican Hat and Gaussian Derivative Wavelets are used to further enhance the features of the object. A Python based QT graphical user interface has been implemented to carry out the process. We show reliable results of the cross-­‐correlation of the objects in multiple band videos.

Torres, Gilbert↗

Differential temperature stress measurement employing array sensor with local offset

The instrument has a focal plane array of infrared sensors of the integrating type such as a multiplexed device in which a charge is built up on a capacitor which is proportional to the total number of photons which that sensor is exposed to between read-out cycles. The infrared sensors of the array are manufactured as part of an overall array which is part of a micro-electronic device. The sensor achieves greater sensitivity by applying a local offset to the output of each sensor before it is converted into a digital word. The offset which is applied to each sensor will typically be the sensor's average value so that the digital signal which is periodically read from each sensor of the array corresponds to the portion of the signal which is varying in time. With proper synchronization between the cyclical loading of the test object and the frame rate of the infrared array the output of the A/D converted signal will correspond to the stress field induced temperature variations. A digital lock-in operation may be performed on the output of each sensor in the array. This results in a test instrument which can rapidly form a precise image of the thermoelastic stresses in an object.

Lesniak, Jon R.↗

Monolithic Active-Pixel Infrared Sensors

Monolithic arrays of active-pixel junction field-effect (JFET) devices made from InGaAs proposed for use as imaging sensors sensitive to light in visible and short-wavelength infrared parts of electromagnetic spectrum. Each pixel of such array comprises photodetector monolithically integrated with JFET output-amplifier circuit of source-follower type - structure similar to charge-coupled device (CCD). Sizes of instruments reduced because large cooling systems not needed.

Fossum, Eric R.↗

Multiple Waveband Temperature Sensor (MWTS)

This slide presentation reviews the development of Multiple Waveband Temperature Sensor (MWTS). The MWTS project will result in a highly stable, monolithically integrated, high resolution infrared detector array sensor that records registered thermal imagery in four infrared wavebands to infer dynamic temperature profiles on a laser-irradiated ground target. An accurate surface temperature measurement of a target in extreme environments in a non-intrusive manner is required. The development challenge is to: determine optimum wavebands (suitable for target temperatures, nature of the targets and environments) to measure accurate target surface temperature independent of the emissivity, integrate simultaneously readable multiband Quantum Well Infrared Photodetectors (QWIPs) in a single monolithic focal plane array (FPA) sensor and to integrate the hardware/software and system calibration for remote temperature measurements. The charge was therefore to develop and demonstrate a multiband infrared imaging camera with the detectors simultaneously sensitive to multiple distinct color bands for front surface temperature measurements Wavelength ( m) measurements. Amongst the requirements are: that the measurement system will not affect target dynamics or response to the laser irradiation and that the simplest criterion for spectral band selection is to choose those practically feasible spectral bands that create the most contrast between the objects or scenes of interest in the expected environmental conditions. There is in the presentation a review of the modeling and simulation of multi-wave infrared temperature measurement and also a review of the detector development and QWIP capacities.

infrared photodector↗

A Dry-Etch Process for Low Temperature Superconducting Transition Edge Sensors for Far Infrared Bolometer Arrays

The next generation of ultra-low power bolometer arrays, with applications in far infrared imaging, spectroscopy and polarimetry, utilizes a superconducting bilayer as the sensing element to enable SQUID multiplexed readout. Superconducting transition edge sensors (TES s) are being produced with dual metal systems of superconductinghormal bilayers. The transition temperature (Tc) is tuned by altering the relative thickness of the superconductor with respect to the normal layer. We are currently investigating MoAu and MoCu bilayers. We have developed a dry-etching process for MoAu TES s with integrated molybdenum leads, and are working on adapting the process to MoCu. Dry etching has the advantage over wet etching in the MoAu system in that one can achieve a high degree of selectivity, greater than 10, using argon ME, or argon ion milling, for patterning gold on molybdenum. Molybdenum leads are subsequently patterned using fluorine plasma.. The dry-etch technique results in a smooth, featureless TES with sharp sidewalls, no undercutting of the Mo beneath the normal metal, and Mo leads with high critical current. The effects of individual processing parameters on the characteristics of the transition will be reported.

Allen, Christine A.↗

Spectral Analysis of the Primary Flight Focal Plane Arrays for the Thermal Infrared Sensor

Thermal Infrared Sensor (TIRS) is a (1) New longwave infrared (10 - 12 micron) sensor for the Landsat Data Continuity Mission, (2) 185 km ground swath; 100 meter pixel size on ground, (3) Pushbroom sensor configuration. Issue of Calibration are: (1) Single detector -- only one calibration, (2) Multiple detectors - unique calibration for each detector -- leads to pixel-to-pixel artifacts. Objectives are: (1) Predict extent of residual striping when viewing a uniform blackbody target through various atmospheres, (2) Determine how different spectral shapes affect the derived surface temperature in a realistic synthetic scene.

Montanaro, Matthew↗

Arrays of Nano Tunnel Junctions as Infrared Image Sensors

Infrared image sensors based on high density rectangular planar arrays of nano tunnel junctions have been proposed. These sensors would differ fundamentally from prior infrared sensors based, variously, on bolometry or conventional semiconductor photodetection. Infrared image sensors based on conventional semiconductor photodetection must typically be cooled to cryogenic temperatures to reduce noise to acceptably low levels. Some bolometer-type infrared sensors can be operated at room temperature, but they exhibit low detectivities and long response times, which limit their utility. The proposed infrared image sensors could be operated at room temperature without incurring excessive noise, and would exhibit high detectivities and short response times. Other advantages would include low power demand, high resolution, and tailorability of spectral response. Neither bolometers nor conventional semiconductor photodetectors, the basic detector units as proposed would partly resemble rectennas. Nanometer-scale tunnel junctions would be created by crossing of nanowires with quantum-mechanical-barrier layers in the form of thin layers of electrically insulating material between them (see figure). A microscopic dipole antenna sized and shaped to respond maximally in the infrared wavelength range that one seeks to detect would be formed integrally with the nanowires at each junction. An incident signal in that wavelength range would become coupled into the antenna and, through the antenna, to the junction. At the junction, the flow of electrons between the crossing wires would be dominated by quantum-mechanical tunneling rather than thermionic emission. Relative to thermionic emission, quantum mechanical tunneling is a fast process.

Son, Kyung-Ah↗

The Cloud Detection and UV Monitoring Experiment (CLUE)

We propose a large-area, low-power instrument to perform CLoud detection and Ultraviolet monitoring, CLUE. CLUE will combine the W detection capabilities of the NIGHTGLOW payload, with an array of infrared sensors to perform cloud slicing measurements. Missions such as EUSO and OWL which seek to measure UHE cosmic-rays at 1W20 eV use the atmosphere as a fluorescence detector. CLUE will provide several important correlated measurements for these missions, including: monitoring the atmospheric W emissions &om 330 - 400 nm, determining the ambient cloud cover during those W measurements (with active LIDAR), measuring the optical depth of the clouds (with an array of narrow band-pass IR sensors), and correlating LIDAR and IR cloud cover measurements. This talk will describe the instrument as we envision it.

Barbier, L.↗

Performance of the QWIP Focal Plane Array for NASA's Landsat 9 Mission

The flight focal plane array (FPA) for the Thermal Infrared Sensor 2 (TIRS-2) instrument, to be flown on Landsat 9, was built and characterized at NASA Goddard Space Flight Center (GSFC). The FPA was assembled using GaAs quantum well infrared photodetector (QWIP) arrays from the same lot as the TIRS instrument on Landsat 8. Each QWIP array is hybridized to an Indigo ISC9803 readout integrated circuit (ROIC) with 640 x 512, 25µm by 25µm pixels. Each QWIP hybrid was tested at the NASA/GSFC Detector Characterization Laboratory (DCL) as a single sensor chip assembly (SCA). The best SCAs in terms of performance were then built up into an FPA consisting of three SCAs, required to provide the necessary 15-degree field of view of the instrument. The FPA was tested to determine if project requirements were being met as a fully assembled unit. The performance of the QWIP SCAs and the fully assembled, NASA flight-qualified FPA will be reviewed.

Quantum well infrared photodiode↗

NASA Tech Briefs, April 2006

The topics covered include: 1) Replaceable Sensor System for Bioreactor Monitoring; 2) Unitary Shaft-Angle and Shaft-Speed Sensor Assemblies; 3) Arrays of Nano Tunnel Junctions as Infrared Image Sensors; 4) Catalytic-Metal/PdO(sub x)/SiC Schottky-Diode Gas Sensors; 5) Compact, Precise Inertial Rotation Sensors for Spacecraft; 6) Universal Controller for Spacecraft Mechanisms; 7) The Flostation - an Immersive Cyberspace System; 8) Algorithm for Aligning an Array of Receiving Radio Antennas; 9) Single-Chip T/R Module for 1.2 GHz; 10) Quantum Entanglement Molecular Absorption Spectrum Simulator; 11) FuzzObserver; 12) Internet Distribution of Spacecraft Telemetry Data; 13) Semi-Automated Identification of Rocks in Images; 14) Pattern-Recognition Algorithm for Locking Laser Frequency; 15) Designing Cure Cycles for Matrix/Fiber Composite Parts; 16) Controlling Herds of Cooperative Robots; 17) Modification of a Limbed Robot to Favor Climbing; 18) Vacuum-Assisted, Constant-Force Exercise Device; 19) Production of Tuber-Inducing Factor; 20) Quantum-Dot Laser for Wavelengths of 1.8 to 2.3 micron; 21) Tunable Filter Made From Three Coupled WGM Resonators; and 22) Dynamic Pupil Masking for Phasing Telescope Mirror Segments.

Source record↗

Integrated infrared and visible image sensors

Semiconductor imaging devices integrating an array of visible detectors and another array of infrared detectors into a single module to simultaneously detect both the visible and infrared radiation of an input image. The visible detectors and the infrared detectors may be formed either on two separate substrates or on the same substrate by interleaving visible and infrared detectors.

Fossum, Eric R.↗

Report of subpanel on image sharpness

Factors effecting the sharpness of images acquired by multispectral scanners, synthetic aperture radar, thermal infrared sensors, and multispectral linear arrays are defined. Factors associated with the sensor include the atmospheric blur/scatter function, the point spread function of the sensor, the sensor aperture, the filter characteristics, and the sampling rate and quatization effects. Several research tasks are proposed which include investigating the use of optical prefilters which include investigating the use of optical prefilters and the relationships of the instantaneous field of view (aperture width) on the performance of geocorrelation systems.

Source record↗

Growing Cobalt Silicide Columns In Silicon

Codeposition by molecular-beam epitaxy yields variety of structures. Proposed fabrication process produces three-dimensional nanometer-sized structures on silicon wafers. Enables control of dimensions of metal and semiconductor epitaxial layers in three dimensions instead of usual single dimension (perpendicular to the plane of the substrate). Process used to make arrays of highly efficient infrared sensors, high-speed transistors, and quantum wires. For fabrication of electronic devices, both shapes and locations of columns controlled. One possible technique for doing this electron-beam lithography, see "Making Submicron CoSi2 Structures on Silicon Substrates" (NPO-17736).

Fathauer, Obert W.↗

Distributed Antenna-Coupled Transition Edge Sensors

We describe progress toward realizing a new architecture for focal plane arrays for the Submillimeter and Far- Infrared (FIR) bands. This architecture is based on a detector design utilizing distributed hot{electron transition edge sensors (TES) coupled to slot antenna elements. Arrays utilizing this type of detector can be considerably easier to manufacture than membrane-isolated TES arrays, because the need for micro-machining is eliminated. We present background and rationale for this new array architecture and details of a new antenna design for an imaging polarimeter, which yields greater bandwidth than past designs. In addition, we describe a cryogenic facility for testing these arrays.

bolometer↗

NASA Tech Briefs, July 2012

Topics covered include: Instrument Suite for Vertical Characterization of the Ionosphere-Thermosphere System; Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure; Pattern Recognition Algorithm for High-Sensitivity Odorant Detection in Unknown Environments; Determining Performance Acceptability of Electrochemical Oxygen Sensors; Versatile Controller for Infrared Lamp and Heater Arrays; High-Speed Scanning Interferometer Using CMOS Image Sensor and FPGA Based on Multifrequency Phase-Tracking Detection; Ultra-Low-Power MEMS Selective Gas Sensors; Compact Receiver Front Ends for Submillimeter-Wave Applications; Dynamically Reconfigurable Systolic Array Accelerator; Blocking Losses With a Photon Counter; Motion-Capture-Enabled Software for Gestural Control of 3D Mod; Orbit Software Suite; CoNNeCT Baseband Processor Module Boot Code SoftWare (BCSW); Trajectory Software With Upper Atmosphere Model; ALSSAT Version 6.0; Employing a Grinding Technology to Assess the Microbial Density for Encapsulated Organisms; Demonstration of Minimally Machined Honeycomb Silicon Carbide Mirrors; Polyimide Aerogel Thin Films; Nanoengineered Thermal Materials Based on Carbon Nanotube Array Composites; Composite Laminate With Coefficient of Thermal Expansion Matching D263 Glass; Robust Tensioned Kevlar Suspension Design; Focal Plane Alignment Utilizing Optical CMM; Purifying, Separating, and Concentrating Cells From a Sample Low in Biomass; Virtual Ultrasound Guidance for Inexperienced Operators; Beat-to-Beat Blood Pressure Monitor; Non-Contact Conductivity Measurement for Automated Sample Processing Systems; An MSK Radar Waveform; Telescope Alignment From Sparsely Sampled Wavefront Measurements Over Pupil Subapertures; Method to Remove Particulate Matter from Dusty Gases at Low Pressures; Terahertz Quantum Cascade Laser With Efficient Coupling and Beam Profile; Measurement Via Optical Near-Nulling and Subaperture Stitching; 885-nm Pumped Ceramic Nd:YAG Master Oscillator Power Amplifier Laser System; Airborne Hyperspectral Imaging System; Heat Shield Employing Cured Thermal Protection Material Blocks Bonded in a Large-Cell Honeycomb Matrix; and Asymmetric Supercapacitor for Long-Duration Power Storage.

Source record↗