Search NASA⌕ Search

SEARCH · Search NASA

Results for “infrared gas analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Intercomparison of eddy correlation carbon dioxide sensors during FIFE 1989

An intercomparison was made of the infrared gas analyzers used in the First ISLSCP Field Experiment (FIFE) 1989 to measure surface fluxes of carbon dioxide immediately following intensive field campaign 5. Fluxes of CO2 agreed to within 15 percent when all instruments are compared; when models of the same type of analyzer were compared, the agreement was within 5 percent. The stability of the calibration coefficients is examined, and it is shown that frequent calibration of the gas analyzers is required. Differences in the physical design of the analyzer models discussed here, such as sampling volume and sensitivity of the electronics to thermal drift, influence the precision of the flux estimates. Spectra and cospectra reveal the degree to which instrumental noise limits the complete sampling of all frequencies of eddies contributing to flux transport.

Moncrieff, J. B.↗

Carbon dioxide fluxes over a raised open bog at the Kinosheo Lake tower site during the Northern Wetlands Study (NOWES)

Measurements of carbon dioxide concentration and flux were made above a raised open bog at Lake Kinosheo in the southern Hudson Bay lowlands during the Northern Wetlands Study (NOWES) experiment in 1990. The flux measurements were made using micrometeorological techniques. They provide the first nondisturbing, larger-scale CO2 flux measurements for this ecosystem and are the first to integrate the exchange over the whole 24 hours of the day. Continuous concentration measurements by infrared gas analyzers (IRGA) and spot flask samples were taken over the period July 1 to July 29. Afternoon CO2 values were only 5 to 7 parts per million by volume (ppmv) lower than measurements over the same period at Canadian background monitoring stations. This suggested that there was little draw-down by local photosynthetic sinks. CO2 fluxes were measured at 8 and 18 m by Bowen ratio and eddy correlation methods, respectively. The methods produced comparable results on averaged data but often diverged considerably on individual half-hour results. Fluxes were small. Daytime values averaged to -0.068 mg/sq m/s by eddy correlation and -0.077 mg/sq m/s by Bowen ratio over the period June 25 to July 28 (negative denotes downward flux), while at night, flux densities were +0.062 mg/sq m/s and +0.085 mg/sq m/s. Integration of the mean diurnal curve gave a net flux of -1.7 g/sq m/d. Comparable data for this type of ecosystem were not found. However, Coyne and Kelley (1975), measuring near Barrow, Alaska, over wet meadow tundra dominated by sedges and grasses, found net fluxes of -7.2 g/sq m/d. Typical net CO2 fluxes from other active temperature ecosystems have been found to be -10 to -20 g/sq m/d (Monteith, 1976). Mean half hourly fluxes were almost constant at +0.06 mg/sq m/s through the nighttime hours. About one half-hour after sunrise the flux reversed direction. Uptake peaked about 0900 eastern daylight time (EDT) and then gradually declined but remained downward until near sunset. The early peak was interpreted to signify that the many plants in the bog experienced water stress during the day as evaporative demand increased and nighttime dew was evaporated.

Neumann, H. H.↗

Greenhouse (III): Gas-Exchange and Seed-to-Seed Experiments on the Russian Space Station MIR and Earth-grown, Ethylene-Treated Wheat Plants

The Mir Space Station provided an outstanding opportunity to study long-term plant responses when exposed to a microgravity environment. Furthermore, if plants can be grown to maturity in a microgravity environment, they might be used in future bioregenerative life-support systems (BLSS). The primary objective of the Greenhouse experiment onboard Mir was to grow Super Dwarf and Apogee wheat through complete life cycles in microgravity; i.e., from seed-to-seed-to-seed. Additional objectives were to study chemical, biochemical, and structural changes in plant tissues as well as photosynthesis, respiration, and transpiration (evaporation of water from plants). Another major objective was to evaluate the suitability clothe facilities on Mir for advanced research with plants. The Greenhouse experiment was conducted in the Russian/Bulgarian plant growth chamber, the Svet, to which the United States added instrumentation systems to monitor changes in CO2 and water vapor caused by the plants (with four infrared gas analyzers monitoring air entering and leaving two small plastic chambers). In addition, the US instrumentation also monitored O2; air, leaf (IR), cabin pressure; photon flux; and substrate temperature and substrate moisture (16 probes in the root module). Facility modifications were first performed during the summer of 1995 during Mir 19, which began after STS-72 left Mir. Plant development was monitored by daily observations and some photographs.

Campbell, William F.↗

Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

Providing adequate carbon dioxide (CO2) washout is essential to the reduction of risk in performing suited operations. Long term CO2 exposure can lead to symptoms such as headache, lethargy, dizziness, and in severe cases can lead to unconsciousness and death. Thus maintaining adequate CO2 washout in both ground testing and during in flight EVAs is a requirement of current and future suit designs. It is necessary to understand the inspired CO2 of suit wearers such that future requirements for space suits appropriately address the risk of inadequate washout. Testing conducted by the EVA Physiology Laboratory at the NASA Johnson Space Center aimed to characterize a method for noninvasively measuring inspired oronasal CO2 under pressurized suited conditions in order to better inform requirements definition and verification techniques for future CO2 washout limits in space suits. Prior work conducted by the EPL examined several different wearable, respirator style, masks that could be used to sample air from the vicinity surround the nose and mouth of a suited test subject. Previously published studies utilized these masks, some being commercial products and some novel designs, to monitor CO2 under various exercise and flow conditions with mixed results for repeatability and/or consistency between subjects. Based on a meta-analysis of those studies it was decided to test a nasal cannula as it is a commercially available device that is placed directly in the flow path of the user as they breathe. A nasal cannula was used to sample air inhaled by the test subjects during both rest and exercise conditions. Eight subjects were tasked with walking on a treadmill or operating an arm ergometer to reach target metabolic rates of 1000, 2000, and 3000 BTU/hr. Suit pressure was maintained at 4.3 psid for all tests, with supply flow rates of 6, 4, and 2 actual cubic feet per minute depending on the test condition. Each test configuration was conducted twice with subjects breathing either through their nose only, or however they felt comfortable. By restricting breathing through a single orifice, we are able to more accurately define exactly what flow stream the sampled CO2 is taken from. Oronasal CO2 was monitored using real time infrared gas analyzers fed via sample tubes connected to the nasal cannula within the suit. Two additional sampling tubes were placed at the head and chin of the test subject, in an effort to capture CO2 concentrations across the entire flow stream of the Mark-III vent system (flow path is head to neck). Metabolic rate was calculated via the exhaust CO2 concentration and used to adjust subject workload on either the treadmill or arm ergometer until the target was reached. Forward work will aim to characterize the historically accepted minimum ppCO2 in suit during EVA by repeating this study in the Extravehicular Mobility Unit (EMU) space suit. This will help to define washout requirements for future suits, be they NASA (e.g. Z-2) or Commercial Crew designed. Additionally it is important to determine the functional consequences of CO2 exposure during EVA. Severe CO2 symptoms are a result of very high concentration, acute exposures. While long term, low concentration exposures have been shown to result in slight cognitive decline, symptoms resolve upon quickly returning to nominal concentrations and it remains unknown the impact that minor deficits in cognitive performance can have on EVA performance.

Norcross, J.↗

Carbon monoxide measurements at Mace Head, Ireland

The North Atlantic Ocean is bordered by continents which may each, under the influence of seasonal weather patterns, act as sources of natural and anthropogenic trace gas and particulate species. Photochemically active species such as carbon monoxide (CO) react to form ozone (O3), a species of critical importance in global climate change. CO is sparingly soluble in water, and the relatively long lifetime of CO in the troposphere makes this species an ideal tracer of air masses with origin over land. We have measured CO using a nondispersive infrared gas filter correlation analyzer at Mace Head on the west coast of Ireland nearly continuously since August 9, 1991. Measurements of CO were acquired at 20-sec resolution and recorded as 60-sec averages. Daily, monthly, and diurnal variation data characteristics of CO mixing ratios observed at this site are reported. Depending on source regions of air parcels passing over this site, 60-min concentrations of CO range from clean air values of approximately 90 ppbv to values in excess of 300 ppbv. Data characterizing the correlation between 60-min CO and O3 mixing ratio data observed at this site are reported also.

Doddridge, Bruce G.↗

In-situ analysis of hydrazine decomposition products

A gas analyzer utilizing a nondispersive infrared (NDIR) detection system was used to monitor the ammonia and water vapor content of the products of a previously unused hydrazine gas generator. This provided an in-situ measurement of the generator's efficiency difficult to obtain by other means. The analyzer was easily installed in both the calibration and hydrazine systems, required no maintenance other than periodic zero adjustments, and performed well for extended periods in the operating range tested. The catalyst bed operated smoothly and repeatably during the 28 hr of testing. No major transients were observed on startup or during steady state operation. The amount of ammonia in the output stream of the gas generator was found to be a strong function of temperature at catalyst bed temperatures below 450 C. At temperatures above this, the efficiency remained nearly constant. On startup the gas generator efficiency was found to decrease with time until a steady state value was attained. Elevated catalyst bed temperatures in the periods before steady state operation was found to be responsible for this phenomenon.

Curran, Francis M.↗

In-situ analysis of hydrazine decomposition products

A gas analyzer utilizing a nondispersive infrared (NDIR) detection system was used to monitor the ammonia and water vapor content of the products of a previously unused hydrazine gas generator. This provided an in-situ measurement of the generator's efficiency difficult to obtain by other means. The analyzer was easily installed in both the calibration and hydrazine systems, required no maintenance other than periodic zero adjustments, and performed well for extended periods in the operating range tested. The catalyst bed operated smoothly and repeatably during the 28 hr of testing. No major transients were observed on startup or during steady state operation. The amount of ammonia in the output stream of the gas generator was found to be a strong function of temperature at catalyst bed temperatures below 450 C. At temperatures above this, the efficiency remained nearly constant. On startup the gas generator efficiency was found to decrease with time until a steady state value was attained. Elevated catalyst bed temperatures in the periods before steady state operation was found to be responsible for this phenomenon.

Curran, Francis M.↗

Carrier suppression device for a heterodyne gas analyzer

Analyzer operates with broadband light from blackbody infrared source. Light is passed sequentially through two gas-filled chambers to suitable infrared detector while pressures in gas-filled chambers are modulated in sinusoidal manner. Because pressure of infrared-absorbing gases in chambers is modulated, amount of light absorbed by gases is also modulated.

Mcclatchie, E. A.↗

Characterization of the physico-chemical properties of polymeric materials for aerospace flight

Materials intended for use in spacecraft are routinely tested at low pressures, and outgassed substances are condensed on cold surfaces at liquid nitrogen temperature, -196 C. These condensates are then analyzed by infrared spectroscopy, and gas chromotography-mass spectroscopy. The polymers were tested and allowed to outgas isothermally at 125 C and 0.000001 torr or less. Valuable information was obtained by extending the temperature range below and above 125 C. The performance of substances of interest to NASA were investigated by thermogravimetric analysis (TGA) from room temperature to 450 C or until the substance decomposed. Thermogravimetric analysis of a substance is a useful technique for studying its thermal nature in both static and dynamic thermal environments. It gives considerable insight into the stability and characterization of substances and the changes they undergo in varying thermal environments. The system is able to get pressures down to 1 micron or 0.001 torr.

Rock, M.↗

Laboratory Methods for the Measurement of Pollutants in Water and Waste Effluents

The requirement for accurate, precise, and rapid analytical procedures for the examination of water and waste samples requires the use of a variety of instruments. The instrumentation in water laboratories includes atomic absorption, UV-visible. and infrared spectrophotometers, automatic colorimetric analyzers, gas chromatographs and mass spectrometers. Because of the emphasis on regulatory action, attention is being directed toward quality control of analytical results. Among the challenging problems are the differentiation of metallic species in water at nanogram concentrations, rapid measurement of free cyanide and free ammonia, more sensitive methods for arsenic and selenium and improved characterization of organic contaminants.

Ballinger, Dwight G.↗

Three stage gas dilution system for calibration of air quality instrumentation

Tests were conducted on a three stage gas dilution system to evaluate the performance of the system for preparation of gas mixtures in the range of concentrations from 1 to 200 ppm. The test gas used in the evaluation was carbon monoxide. Mixtures of carbon monoxide and air were prepared in the gas dilution system and analyzed on stream with a commercially available infrared CO detector. Results showed the gas dilution system to be accurate to within 5, 3, and 2 percent in the respective ranges of 1-20 ppm, 20-50 ppm, and 50-200 ppm.

Gregory, G. L.↗

Discourse for slide presentation: An overview of chemical detection systems

A brief overview of some of the analytical techniques currently used in monitoring and analyzing permanent gases and selected volatile organic compound in air are presented. Some of the analytical considerations in developing a specific method are discussed. Four broad groups of hardware are discussed: compound class specific personal monitors, gas chromatographic systems, infrared spectroscopic systems, and mass spectrometric residual gas analyzer systems. Three types of detectors are also discussed: catalytic sensor based systems, photoionization detectors, and wet or dry chemical reagent systems. Under gas chromatograph based systems five detector systems used in combination with a GC are covered: thermal conductivity detectors, photoionization detectors, Fourier transform infrared spectrophotometric systems, quadrapole mass spectrometric systems, and a relatively recent development, a surface acoustic wave vapor detector.

Peters, Randy Alan↗

A HIRES analysis of the FIR emission of supernova remnants

The high resolution (HiRes) algorithm has been used to analyze the far infrared emission of shocked gas and dust in supernova remnants. In the case of supernova remnant IC 443, we find a very good match between the resolved features in the deconvolved images and the emissions of shocked gas mapped in other wavelengths (lines of H2, CO, HCO+, and HI). Dust emission is also found to be surrounding hot bubbles of supernova remnants which are seen in soft X-ray maps. Optical spectroscopy on the emission of the shocked gas suggests a close correlation between the FIR color and local shock speed, which is a strong function of the ambient (preshock) gas density. These provide a potentially effective way to identify regions of strong shock interaction, and thus facilitate studies of kinematics and energetics in the interstellar medium.

Wang, Zhong↗

Application of Long-Path Gas Cell Assisted Infrared Spectroscopy for Detection of Lunar Volatiles and Advanced Curation Efforts

The motivation behind analyzing gaseous samples from the Permanently Shadowed Regions (PSRs) on the lunar surface is built upon the volatiles observed during the LCROSS mission. Advanced curation techniques under cold conditions are essential to the critical scientific analysis of these returned samples. The detection of various volatiles in returned samples by gas-phase infrared (IR) spectroscopy is known to be a powerful tool to understand the resources present in planetary bodies and Astro-materials. The identification and quantification of volatile compounds in returned planetary samples and regolith simulants by advanced and custom-built analytical devices are areas of primary research interest in our group and the Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility. In this context, we discuss recent advancements and experimental results for quick analysis of the major volatiles detected by the LCROSS (water, CO 2 , CH 3 OH, and NH 3 ) by a long-path gas cell/FTIR (Fourier Transform Infrared) spectrometer system. The applicability of this system is demonstrated by qualitative analysis of a series of volatiles measured individually. In addition, the linear dependence of absorption intensity on headspace sample volumes was checked by measuring gas-phase IR absorption spectra of increasing volumes of pure CO 2 gas aliquots. Finally, the instrument performance was evaluated by measuring the relative concentration of NH 3 (g) in methanol solution.

Curation↗

Improved nondispersive infrared analyzer

Light from radiant energy source passes through filter, sample, and reference gas chambers to detector. Chamber with amount of gas to be measured is sealed. Filter may be gelatinous, interference, dispersive, or negative-gas, as required.

Dimeff, J.↗

Measurements of C02 Distribution in Saturn's Atmosphere by Cassini-Infrared Observations

The Fourier transform infrared spectrometer aboard the Cassini spacecraft, inserted in Saturn s orbit in July 2004, has been providing high resolution/high sensitivity infrared (IR) spectra of the Saturnian system. The measurements cover the spectral range of 10-1400/cm with variable spectral resolutions of 0.53 to 15/cm, exhibiting spectral features of a series of trace gases including CO2 and H2O. The observed spectra may be analyzed for retrieval of global P/T and gas density profiles of Saturn. The infrared measurements of Saturn by ISO(SWS) have indicated unexpected large abundances of CO2 in Saturn's atmosphere. The rigorous photochemical models of Saturn's atmosphere that have been developed indicate exogenic oxygen influx of icy dust grains that lead to the production of CO2. The distribution of CO2 in Saturn's atmosphere needs to be confirmed, and the nature of exogenic sources remains to be investigated. This paper presents comprehensive measurements of the CO2 distribution in Saturn's atmosphere by Cassini IR observations.

Abbas, M. M.↗

Molecule formation and infrared emission in fast interstellar shocks. I Physical processes

The paper analyzes the structure of fast shocks incident upon interstellar gas of ambient density from 10 to the 7th per cu cm, while focusing on the problems of formation and destruction of molecules and infrared emission in the cooling, neutral post shock gas. It is noted that such fast shocks initially dissociate almost all preexisting molecules. Discussion covers the physical processes which determine the post shock structure between 10 to the 4 and 10 to the 2 K. It is shown that the chemistry of important molecular coolants H2, CO, OH, and H2O, as well as HD and CH, is reduced to a relatively small set of gas phase and grain surface reactions. Also, the chemistry follows the slow conversion of atomic hydrogen into H2, which primarily occurs on grain surfaces. The dependence of this H2 formation rate on grain and gas temperatures is examined and the survival of grains behind fast shocks is discussed. Post shock heating and cooling rates are calculated and an appropriate, analytic, universal cooling function is developed for molecules other than hydrogen which includes opacities from both the dust and the lines.

Hollenbach, D.↗