Search NASA⌕ Search

SEARCH · Search NASA

Results for “inline”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A novel electron gun for inline MRI-linac configurations

Purpose: This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Methods: Simple electron gun geometry modifications of a Varian 600C electron gun are considered and solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Results: Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ±15 cm along the axis of the 0.5 T magnet without capture efficiency reduction below the experimental value in zero field. In this range of linac displacements, the electron beam generated by the new gun geometry is more effectively injected into the linac in the presence of an external magnetic field, resulting in approximately 20% increase of the target current compared to the original gun geometry behavior at zero field. The new gun geometry can generate and accelerate electron beams in external magnetic fields without current loss for fields higher than 0.11 T. The new electron-gun geometry is robust enough to function in the fringe fields of the other two magnets with a target current loss of no more than 16% with respect to the current obtained with no external magnetic fields. Conclusions: In this work, a specially designed electron gun was presented which can operate in the presence of axisymmetric strong magnetic fringe fields of MRI magnets. Computer simulations show that the electron gun can produce high quality beams which can be injected into a straight through linac such as Varian 600C and accelerated with more efficiency in the presence of the external magnetic fields. Also, the new configuration allows linac displacements along the magnet axis in a range equal to the diameter of the imaging spherical volume of the magnet under consideration. The new electron gun-linac system can function in the fringe field of a MRI magnet if the field strength at the cathode position is higher than 0.11 T. The capture efficiency of the linac depends on the magnetic field strength and the field gradient. The higher the gradient the better the capture efficiency. The capture efficiency does not degrade more than 16%.

43 PARTICLE ACCELERATORS↗

Mesofluidic Inline Separation for Produced Water Treatment

Mesofluidic inline separation developed by PNNL represents an opportunity to remove a key barrier in the treatment of produced water, namely suspended solids that clog downstream operations. The US alone produces over 800 billion gallons of produced water each year, most of which is reinjected underground (but not into the aquifers) as waste. The impact from treating and reusing even a fraction of this wastewater is immense as aquifers in the Midwest and elsewhere dry. The work described herein is essential to leveraging the opportunity to improve produced water quality (to allow for beneficial use) by combining mesofluidic inline separators with reverse osmosis systems. Providing water for agricultural and industrial uses in the American Southwest and Midwest by allowing the reuse of petroleum produced water may be critical to the long-term economics of the region. This is especially true as drought conditions are rapidly lowering aquifer levels in these regions. The incumbent technology for desalination is reverse osmosis (RO) due to its ability to treat a wide range of feedwaters and technological maturity. However, suspended solids cause RO (and other dissolved solids removal technologies) to become clogged and loose performance. A common strategy is to use prefilters upstream of RO systems, but these membrane-based filters easily clog and require regular maintenance. Unlike membrane filters, mesofluidic inline separators provide removal of suspended solids with much lower pressure drops than conventional systems filtration systems, permitting substantially higher flowrates. Although the amount of produced water from petroleum operations is vast, only a small fraction of it is reused or turned into potable water, for example, because of the lack of technologies to remove both dissolved and suspended solids at a significant throughput. This project shows that mesofluidic inline separators coupled with a commercial dissolved solids removal technology (RO) are positioned to do exactly that. Mesofluidic inline separators fit within commercial piping and are tunable for particle sizes of interest as described below. Indeed, mesofluidic inline separators have remarkably smaller footprints than competing filtration technologies and are easily transportable from jobsite to jobsite. This technology has no moving parts so that solids removal can be accomplished at much lower operating cost.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lagrangian transport characteristics of a class of three-dimensional inline-mixing flows with fluid inertia

Laminar mixing by the inline-mixing principle is a key to many industrial fluids-engineering systems of size extending from micrometers to meters. However, insight into fundamental transport phenomena particularly under the realistic conditions of three-dimensionality (3D) and fluid inertia remains limited. This study addresses these issues for inline mixers with cylindrical geometries and adopts the Rotated Arc Mixer (RAM) as a representative system. Transport is investigated from a Lagrangian perspective by identifying and examining coherent structures that form in the 3D streamline portrait. 3D effects and fluid inertia introduce three key features that are not found in simplified configurations: transition zones between consecutive mixing cells of the inline-mixing flow; local upstream flow (in certain parameter regimes); transition/inertia-induced breaking of symmetries in the Lagrangian equations of motion (causing topological changes in coherent structures). Topological considerations strongly suggest that there nonetheless always exists a net throughflow region between inlet and outlet of the inline-mixing flow that is strictly separated from possible internal regions. The Lagrangian dynamics in this region admits representation by a 2D time-periodic Hamiltonian system. This establishes one fundamental kinematic structure for the present class of inline-mixing flows and implies universal behavior in that all states follow from the Hamiltonian breakdown of one common integrable state. A so-called period-doubling bifurcation is the only way to eliminate transport barriers originating from this state and thus is a necessary (yet not sufficient) condition for global chaos. Important in a practical context is that a common simplification in literature, i.e., cell-wise fully-developed Stokes flow (“2.5D approach”), retains these fundamental kinematic properties and deviates from the generic 3D inertial case only in a quantitative sense. This substantiates its suitability for (at least first exploratory) studies on (qualitative) mixing properties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-G-BRD-05: Inline Magnetic Fields Enhance Tumor Dose for Small Lung Cancers

Purpose: To report on significant dose enhancement effects caused by magnetic fields aligned parallel to 6MV photon beam radiotherapy of small lung tumors. Findings are applicable to future inline MRI-guided radiotherapy systems. Methods: 9 clinical lung plans were recalculated using Monte Carlo methods and external inline (parallel to the beam direction) magnetic fields of 0.5 T, 1.0 T and 3 T were included. Three plans were 6MV 3D-CRT and six were 6MV IMRT. The GTV’s ranged from 0.8 cc to 73 cc, while the PTV ranged from 1 cc to 180 cc. Results: The inline magnetic field has a moderate impact in lung dose distributions by reducing the lateral scatter of secondary electrons and causing a small local dose increase. Superposition of multiple small beams acts to superimpose the small dose increases and can lead to significant dose enhancements, especially when the GTV is low density. Two plans with very small, low mean density GTV’s (<1 cc, ρ(mean)<0.35g/cc) showed uniform increases of 16% and 23% at 1 T throughout the PTV. Three plans with moderate mean density PTV’s (3–13 cc, ρ(mean)=0.58–0.67 g/cc) showed 6% mean dose enhancement at 1 T in the PTV, however not uniform throughout the GTV/PTV. Replanning would benefit these cases. The remaining 5 plans had large dense GTV’s (∼ 1 g/cc) and so only a minimal (<2%) enhancement was seen. In general the mean dose enhancement at 0.5 T was 60% less than 1 T, while 5–50% higher at 3 T. Conclusions: A paradigm shift in the efficacy of small lung tumor radiotherapy is predicted with future inline MRI-linac systems. This will be achieved by carefully taking advantage of the reduction of lateral electronic disequilibrium withing lung tissue that is induced naturally inside strong inline magnetic fields.

60 APPLIED LIFE SCIENCES↗

Technical Note: Experimental results from a prototype high-field inline MRI-linac

Purpose: The pursuit of real-time image guided radiotherapy using optimal tissue contrast has seen the development of several hybrid magnetic resonance imaging (MRI)-treatment systems, high field and low field, and inline and perpendicular configurations. As part of a new MRI-linac program, an MRI scanner was integrated with a linear accelerator to enable investigations of a coupled inline MRI-linac system. This work describes results from a prototype experimental system to demonstrate the feasibility of a high field inline MR-linac. Methods: The magnet is a 1.5 T MRI system (Sonata, Siemens Healthcare) was located in a purpose built radiofrequency (RF) cage enabling shielding from and close proximity to a linear accelerator with inline (and future perpendicular) orientation. A portable linear accelerator (Linatron, Varian) was installed together with a multileaf collimator (Millennium, Varian) to provide dynamic field collimation and the whole assembly built onto a stainless-steel rail system. A series of MRI-linac experiments was performed to investigate (1) image quality with beam on measured using a macropodine (kangaroo) ex vivo phantom; (2) the noise as a function of beam state measured using a 6-channel surface coil array; and (3) electron contamination effects measured using Gafchromic film and an electronic portal imaging device (EPID). Results: (1) Image quality was unaffected by the radiation beam with the macropodine phantom image with the beam on being almost identical to the image with the beam off. (2) Noise measured with a surface RF coil produced a 25% elevation of background intensity when the radiation beam was on. (3) Film and EPID measurements demonstrated electron focusing occurring along the centerline of the magnet axis. Conclusions: A proof-of-concept high-field MRI-linac has been built and experimentally characterized. This system has allowed us to establish the efficacy of a high field inline MRI-linac and study a number of the technical challenges and solutions.

60 APPLIED LIFE SCIENCES↗

Efficient 3-D velocity model building using joint inline and crossline plane-wave wave-equation migration velocity analyses

SUMMARY Wave-equation migration velocity analysis (WEMVA) is an image-domain inversion method for velocity model building. Automatic plane-wave WEMVA (PWEMVA) calculates the moveouts of plane-wave common-image gathers (CIGs) by searching a best-fitting parabola with semblance analysis and backprojects residual CIG moveouts into wavefield wave paths with a reflection tomographic kernel. However, 3-D PWEMVA is very computationally expensive because 3-D reflection tomographic inversion requires at least five 3-D reverse-time migrations per iteration and stores two types of source wavefields at model boundaries. We develop a joint inline and crossline PWEMVA method for efficient 3-D velocity model building. We alternatively implement the inline and crossline PWEMVAs with a constraint for each other, in which we iteratively construct the 3-D velocity model update through 1-D spline interpolation of 2-D gradients. The inline and crossline joint inversion is practical since PWEMVA only inverts for low-wavenumber velocity perturbations along wave paths, and the method can take less than 1 per cent of the computational cost of full 3-D PWEMVA. To construct unaliased plane waves for our joint inline and crossline PWEMVA, we develop a 3-D data interpolation method in the frequency–wavenumber (FK) domain to recover regularly and randomly missing traces. The method minimizes the misfit on sufficiently localized data subsets with iterative optimal step lengths and a gradient preconditioner that iteratively selects dominant dips along different azimuths. In numerical experiments, we use a 3-D synthetic seismic data set and a land 3-D field seismic data set acquired at the Farnsworth CO2-EOR (enhanced oil recovery) field to demonstrate the efficacy of our velocity model building and data interpolation methods.

Liu, Xuejian↗

Dose enhancement in radiotherapy of small lung tumors using inline magnetic fields: A Monte Carlo based planning study

Purpose: To report on significant dose enhancement effects caused by magnetic fields aligned parallel to 6 MV photon beam radiotherapy of small lung tumors. Findings are applicable to future inline MRI-guided radiotherapy systems. Methods: A total of eight clinical lung tumor cases were recalculated using Monte Carlo methods, and external magnetic fields of 0.5, 1.0, and 3 T were included to observe the impact on dose to the planning target volume (PTV) and gross tumor volume (GTV). Three plans were 6 MV 3D-CRT plans while 6 were 6 MV IMRT. The GTV’s ranged from 0.8 to 16 cm{sup 3}, while the PTV’s ranged from 1 to 59 cm{sup 3}. In addition, the dose changes in a 30 cm diameter cylindrical water phantom were investigated for small beams. The central 20 cm of this phantom contained either water or lung density insert. Results: For single beams, an inline magnetic field of 1 T has a small impact in lung dose distributions by reducing the lateral scatter of secondary electrons, resulting in a small dose increase along the beam. Superposition of multiple small beams leads to significant dose enhancements. Clinically, this process occurs in the lung tissue typically surrounding the GTV, resulting in increases to the D{sub 98%} (PTV). Two isolated tumors with very small PTVs (3 and 6 cm{sup 3}) showed increases in D{sub 98%} of 23% and 22%. Larger PTVs of 13, 26, and 59 cm{sup 3} had increases of 9%, 6%, and 4%, describing a natural fall-off in enhancement with increasing PTV size. However, three PTVs bounded to the lung wall showed no significant increase, due to lack of dose enhancement in the denser PTV volume. In general, at 0.5 T, the GTV mean dose enhancement is around 60% lower than that at 1 T, while at 3 T, it is 5%–60% higher than 1 T. Conclusions: Monte Carlo methods have described significant and predictable dose enhancement effects in small lung tumor plans for 6 MV radiotherapy when an external inline magnetic field is included. Results of this study indicate that future clinical inline MRI-guided radiotherapy systems will be able to deliver a dosimetrically superior treatment to small (PTV < 15 cm{sup 3}), isolated lung tumors over non-MRI-Linac systems. This increased efficacy coincides with the reimbursement in the United States of lung CT screening and the likely rapid growth in the number of patients with small lung tumors to be treated with radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-AB-BRA-12: Experimental Results From the First High-Field Inline MRI-Linac

Purpose: The pursuit of real-time image guided radiotherapy using optimal tissue contrast has seen the development of several hybrid MRI-treatment systems, high field and low field, and inline and perpendicular configurations. As part of a new MRI-Linac program, an MRI scanner was integrated with a linear accelerator to enable investigations of a coupled inline MRI-Linac system. This work describes our experimental results from the first high-field inline MRI-Linac. Methods: A 1.5 Tesla magnet (Sonata, Siemens) was located in a purpose built RF cage enabling shielding from and close proximity to a linear accelerator with inline orientation. A portable linear accelerator (Linatron, Varian) was installed together with a multi-leaf collimator (Millennium, Varian) to provide dynamic field collimation and the whole assembly built onto a stainless-steel rail system. A series of MRI-Linac experiments was performed to investigate: (1) image quality with beam on measured using a macropodine (kangaroo) ex vivo phantom; (2) the noise as a function of beam state measured using a 6-channel surface coil array and; (3) electron focusing measured using GafChromic film. Results: (1) The macropodine phantom image quality with the beam on was almost identical to that with the beam off. (2) Noise measured with a surface RF coil produced a 25% elevation of background noise when the radiation beam was on. (3) Film measurements demonstrated electron focusing occurring at the center of the radiation field. Conclusion: The first high-field MRI-Linac has been built and experimentally characterized. This system has allowed us to establish the efficacy of a high field in-line MRI-Linac and study a number of the technical challenges and solutions. Supported by the Australian National Health and Medical Research Council, the Australian Research Council, the Australian Cancer Research Foundation and the Health and Hospitals Fund.

60 APPLIED LIFE SCIENCES↗

Raytheon's next generation compact inline cryocooler architecture

Since the 1970s, Raytheon has developed, built, tested and integrated high performance cryocoolers. Our versatile designs for single and multi-stage cryocoolers provide reliable operation for temperatures from 10 to 200 Kelvin with power levels ranging from 50 W to nearly 600 W. These advanced cryocoolers incorporate clearance seals, flexure suspensions, hermetic housings and dynamic balancing to provide long service life and reliable operation in all relevant environments. Today, sensors face a multitude of cryocooler integration challenges such as exported disturbance, efficiency, scalability, maturity, and cost. As a result, cryocooler selection is application dependent, oftentimes requiring extensive trade studies to determine the most suitable architecture. To optimally meet the needs of next generation passive IR sensors, the Compact Inline Raytheon Stirling 1-Stage (CI-RS1), Compact Inline Raytheon Single Stage Pulse Tube (CI-RP1) and Compact Inline Raytheon Hybrid Stirling/Pulse Tube 2-Stage (CI-RSP2) cryocoolers are being developed to satisfy this suite of requirements. This lightweight, compact, efficient, low vibration cryocooler combines proven 1-stage (RS1 or RP1) and 2-stage (RSP2) cold-head architectures with an inventive set of warm-end mechanisms into a single cooler module, allowing the moving mechanisms for the compressor and the Stirling displacer to be consolidated onto a common axis and in a common working volume. The CI cryocooler is a significant departure from the current Stirling cryocoolers in which the compressor mechanisms are remote from the Stirling displacer mechanism. Placing all of the mechanisms in a single volume and on a single axis provides benefits in terms of package size (30% reduction), mass (30% reduction), thermodynamic efficiency (>20% improvement) and exported vibration performance (≤25 mN peak in all three orthogonal axes at frequencies from 1 to 500 Hz). The main benefit of axial symmetry is that proven balancing techniques and hardware can be utilized to null all motion along the common axis. Low vibration translates to better sensor performance resulting in simpler, more direct mechanical mounting configurations, eliminating the need for convoluted, expensive, massive, long lead damping hardware.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D simulations of inertial confinement fusion implosions part 1: inline modeling of polarized cross beam energy transfer and subsequent drive anomalies on OMEGA and NIF

Inertial confinement fusion experiments are sensitive to cross-beam energy transfer (CBET), a laser-plasma instability that redistributes laser energy in the coronal plasma through self-generated ion acoustic wave (IAW) gratings. The detailed CBET coupling depends on the polarization state of the crossing wavefields. CBET itself can also scramble the beam polarizations by inducing ellipticity through the IAW grating, and rotating the seed polarization toward that of the pump. We develop a ray-based model that describes the polarized CBET coupling and that is compatible with the framework of 3D inline radiative hydrodynamics simulations. The model is implemented in the ASTER/IFRIIT code and verified against an academic test case and an offline polarized CBET post-processor. It is then applied to the detailed configuration of the distributed polarization rotator system on OMEGA, where results highlight how polarized CBET induces significant low modes in the collisional absorption source term. Finally, the modeling is applied to a simple indirect-drive configuration, comparing CBET calculations with 96 unpolarized or polarized beams with 24 unpolarized quads. It is shown that these cases produce similar power amplification per cone of beams grouped with similar polar angles. However, the 96 beam geometry itself is found to reduce azimuthal variations in quad power after the interaction and favors beams with larger polar angles within the cones, an effect that is amplified by the polarized CBET. Application of the model to inline calculations of OMEGA implosions are presented in a companion paper.

3D inline modeling↗

WE-G-17A-09: Novel Magnetic Shielding Design for Inline and Perpendicular Integrated 6 MV Linac and 1.0 T MRI Systems

Purpose: The influence of fringe magnetic fields delivered by magnetic resonance imaging (MRI) on the beam generation and transportation in Linac is still a major challenge for the integration of linear accelerator and MRI (Linac-MRI). In this study, we investigated an optimal magnetic shielding design for Linac-MRI and further characterized the beam trajectory in electron gun. Methods: Both inline and perpendicular configurations were analyzed in this study. The configurations, comprising a Linac-MRI with a 100cm SAD and an open 1.0 T superconductive magnet, were simulated by the 3D finite element method (FEM). The steel shielding around the Linac was included in the 3D model, the thickness of which was varied from 1mm to 20mm, and magnetic field maps were acquired with and without additional shielding. The treatment beam trajectory in electron gun was evaluated using OPERA 3d SCALA with and without shielding cases. Results: When Linac was not shielded, the uniformity of diameter sphere volume (DSV) (30cm) was about 5 parts per million (ppm) and the fringe magnetic fields in electron gun were more than 0.3 T. With shielding, the magnetic fields in electron gun were reduced to less than 0.01 T. For the inline configuration, the radial magnetic fields in the Linac were about 0.02T. A cylinder steel shield used (5mm thick) altered the uniformity of DSV to 1000 ppm. For the perpendicular configuration, the Linac transverse magnetic fields were more than 0.3T, which altered the beam trajectory significantly. A 8mm-thick cylinder steel shield surrounding the Linac was used to compensate the output losses of Linac, which shifted the magnetic fields' uniformity of DSV to 400 ppm. Conclusion: For both configurations, the Linac shielding was used to ensure normal operation of the Linac. The effect of magnetic fields on the uniformity of DSV could be modulated by the shimming technique of the MRI magnet. NIH/NIGMS grant U54 GM104944, Lincy Endowed Assistant Professorship.

43 PARTICLE ACCELERATORS↗

Phase conjugate digital inline holography (PCDIH)

We report digital inline holography (DIH) provides instantaneous three-dimensional (3D) measurements of diffracting objects; however, phase disturbances in the beam path can distort the imaging. In this Letter, a phase conjugate digital inline holography (PCDIH) configuration is proposed for removal of phase disturbances. Brillouin-enhanced four-wave mixing produces a phase conjugate signal that back propagates along the DIH beam path. Finally, the results demonstrate the removal of distortions caused by gas-phase shocks to recover 3D images of diffracting objects.

36 MATERIALS SCIENCE↗

Agglomerate Sizing in Aluminized Propellants Using Digital Inline Holography and Traditional Diagnostics

Aluminized ammonium perchlorate composite propellants can form large molten agglomerated particles that may result in poor combustion performance, slag accumulation, and increased two-phase flow losses. Quantifying agglomerate size distributions are needed to gain an understanding of agglomeration dynamics and ultimately design new propellants for improved performance. Due to complexities of the reacting multiphase environment, agglomerate size diagnostics are difficult and measurement accuracies are poorly understood. To address this, the current paper compares three agglomerate sizing techniques applied to two propellant formulations. Particle collection on a quench plate and backlit videography are two relatively common techniques, whereas digital inline holography is an emerging alternative for three-dimensional measurements. Atmospheric pressure combustion results show that all three techniques are able to capture the qualitative trends; however, significant differences exist in the quantitative size distributions and mean diameters. For digital inline holography, methods are proposed that combine temporally resolved high-speed recording with lower-speed but higher spatial resolution measurements to correct for size–velocity correlation biases while extending the measurable size dynamic range. Finally, the results from this work provide new guidance for improved agglomerate size measurements along with statistically resolved datasets for validation of agglomerate models.

42 ENGINEERING↗

Responsive Image Inline Filter

RIIF is a contributed module for the Drupal php web application framework (drupal.org). It is written as a helper or sub-module of other code which is part of version 8 "core Drupal" and is intended to extend its functionality. It allows Drupal to resize images uploaded through the user-facing text editor within the Drupal GUI (a.k.a. "inline images") for various browser widths. This resizing is already done foe other images through the parent "Responsive Image" core module. This code extends that functionality to inline images.

Freeman, Ian↗

Inline gamma-spectrometry of fission product elements after rapid high-pressure ion chromatographic separation

Analysis of irradiated material shortly after irradiation can be non-trivial due to highly radioactive activation and fission isotopes increasing dead time in gamma-ray detection systems, often requiring a “cooling-period” between receipt of a sample and the subsequent analysis. A direct separation–detection method has been developed combining ion chromatography and inductively coupled mass spectrometry for rapid, low-level analysis of fission products; it cannot, however, detect certain short-lived species below the detection limit of the system. In this paper we report the implementation of an inline gamma-ray detector, which was added post-separation, pre-analysis, to test the quality and utility of elementally-isolated gamma-ray spectroscopy.

Inline gamma-ray detection↗

Analysis of the laser welding keyhole using inline coherent imaging

Laser beam welding is a widely used fusion welding process in many industrial applications such as automotive, aerospace, energy, defense, and medical products. Industry has a fundamental need to model the laser welding process to minimize experimental testing and improve confidence in production welds. However, computational models attempting to predict weld formation are limited by an incomplete understanding of the beam-material interactions. As a consequence, these models do not accurately predict the mechanisms associated with laser weld formation. To improve the current state of prediction capabilities, it is vital to better detect/measure the physical aspects of the weld pool during high energy density welding. In this work, a novel real-time laser weld monitoring device using inline coherent imaging (ICI) was used to provide a fundamental understanding of laser weld formation via vaporization. The objective of this work was to investigate and quantify the relationship relating laser weld parameters and the vapor capillary (keyhole) through a state-of-the-art measurement technique. Bead-on-plate laser beam welds were produced with partial penetration on 304L stainless steel, 2205 duplex stainless steel, and Ti-6Al-4V. Keyhole monitoring was performed using a commercially available ICI system to collect keyhole penetration data in real time. These measurements were reconstructed to generate the vapor capillary shape at different welding parameters. Process parameters significantly influenced the keyhole shape and the keyhole root position relative to the process beam. Finally, the keyhole geometry showed distinct differences between the stainless steel alloys and Ti-6Al-4V.

2205↗