Ac ratio transformer technique for precision insertion loss measurements.
Precision microwave insertion loss measurement using AC ratio transformer technique
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Precision microwave insertion loss measurement using AC ratio transformer technique
This paper describes a laboratory study of add-on acoustic treatments for a propeller-driven light aircraft fuselage. The treatments included: no treatment (i.e., baseline fuselage); a production-type double-wall interior; and various amounts of high density fiberglass added to the baseline fuselage. The sound source was a pneumatic-driver with attached exponential horn, supplied with a broadband signal. Data were acquired at the approximate head positions of the six passenger seats. The results were analyzed on space-averaged narrowband, one-third octave band and overall insertion loss basis. In addition, insertion loss results for the different configurations at specific frequencies representing propeller tone spectra are presented. The propeller tone data includes not only the space-averaged insertion loss, but also the variation of insertion loss at these particular frequencies across the six microphone positions.
Radome material insertion loss measurement by radiometric method noting error analysis
Dual-channel microwave insertion loss test set which incorporates power meter coaxial thermistors with dc nulling scheme
Precision dc potentiometer microwave insertion loss test set for calibrating low noise microwave receiving systems used in space communications
Radiometer system measures effective noise temperature directed towards sky, with and without radome over antenna horn. Data is then translated into computer format. With additional transmission line insertion loss data from other measurements, computer calculates insertion loss of radome material.
A method to intended for measurement of the insertion loss of an acoustic treatment applied to an aircraft fuselage in-situ is documented in this paper. Using this method, the performance of a treatment applied to a limited portion of an aircraft fuselage can be assessed even though the untreated fuselage also radiates into the cabin, corrupting the intensity measurement. This corrupting noise in the intensity measurement incoherent with the panel vibration of interest is removed by correlating the intensity to reference transducers such as accelerometers. Insertion loss of the acoustic treatments is estimated from the ratio of correlated intensity measurements with and without a treatment applied. In the case of turbulent boundary layer excitation of the fuselage, this technique can be used to assess the performance of noise control methods without requiring treatment of the entire fuselage. Several experimental studies and numerical simulations have been conducted, and results from three case studies are documented in this paper. Conclusions are drawn about the use of this method to study aircraft sidewall treatments.
Dual channel waveguide insertion loss test set for calibrations at 90 GHz in radio astronomy and communication systems, using sprayed thermistor mount
An improved test method accurately measures the insertion loss of RF components while avoiding amplifier drift. Currents are balanced across a bridge transformer with shorted probes and then with each component to be tested. Differences in adjustments indicate the loss.
This paper describes two independent methods for estimating the insertion loss of patch array antennas that were developed for the Juno Microwave Radiometer instrument. One method is based principally on pattern measurements while the other method is based solely on network analyzer measurements. The methods are accurate to within 0.1 dB for the measured antennas and show good agreement (to within 0.1dB) of separate radiometric measurements.
Thermistor mount for dc potentiometer insertion loss test set
A key challenge of photon counting optical communication is delivering light with atmospherically distorted wavefronts from the telescope to detectors efficiently. When using fiber coupled single photon detectors, the efficiency of the transmittance is constrained by the modes supported by the fiber. The number of modes supported by a fiber depends on the size of the core. The larger the core, the more modes supported. However, commercial off the shelf superconducting nanowire single photon detectors (SNSPDs) are currently limited in area, which limits the core size of the fibers that can efficiently couple to the detectors. To increase the amount of light that can be delivered to the detectors, NASA Glenn Research Center is considering many different fiber/detector architectures. This paper compares insertion loss of the fiber device for two different architectures: • a multi-plane light conversion device to split the light from a 30 µm core diameter fiber into 7 separate, 15 µm core diameter few-mode fibers butt-coupled to 7 single-element SNSPDs, and • a 30 µm core diameter multimode fiber butt-coupled to a 16 multi-element, SNSPD array. The measured insertion loss for each fiber device under emulated atmospheric conditions with D/r0 between 2 and 30 is presented. The multi-plane light conversion device shows a consistent ~1 dB loss more than the multimode fiber. Also presented is the measured uneven power splitting of the multiplane light conversion device, especially at lower D/r0. How this uneven power splitting contributes to system loss called blocking loss is discussed.
A key challenge of photon counting optical communication is delivering light with atmospherically distorted wavefronts from the telescope to detectors efficiently. When using fiber coupled single photon detectors, the efficiency of the transmittance is constrained by the modes supported by the fiber. The number of modes supported by a fiber depends on the size of the core. The larger the core, the more modes supported. However, commercial off the shelf superconducting nanowire single photon detectors (SNSPDs) are currently limited in area, which limits the core size of the fibers that can efficiently couple to the detectors. To increase the amount of light that can be delivered to the detectors, NASA Glenn Research Center is considering many different fiber/detector architectures. This paper compares insertion loss of the fiber device for two different architectures: • a multi-plane light conversion device to split the light from a 30 µm core diameter fiber into 7 separate, 15 µm core diameter few-mode fibers butt-coupled to 7 single-element SNSPDs, • and a 30 µm core diameter multimode fiber butt-coupled to a 16 multi-element, SNSPD array. The measured insertion loss for each fiber device under emulated atmospheric conditions with D/r0 between 2 and 30 is presented. The multi-plane light conversion device shows a consistent ~1 dB loss more than the multimode fiber. Also presented is the measured uneven power splitting of the multiplane light conversion device, especially at lower D/r0. How this uneven power splitting contributes to system loss called blocking loss is discussed.
Low insertion loss, capacitively scanned goniometer for faraday rotation in very high frequency range
Precision DC potentiometer microwave test set for coaxial or waveguide insertion loss measurement
Precision DC potentiometer test for measuring microwave coaxial or waveguide insertion loss
High impedance alternating current sensing transformer device between two bolometers for measuring insertion loss of test component
Two superconducting Tl-Ca-Cu-Ba-O bandpass filters were fabricated for JPL by Superconductor Technologies Incorporated, Santa Barbara, California. The filters were designed to operate at 2.3 GHz (S-band) with a 0.5-dB bandwidth of 60 MHz and at 8.45 GHz (X-band) with a 0.5-dB bandwidth of 150 MHz. The structure selected for both filters incorporates half-wavelength thin-film resonators in a stripline configuration. The S-band filter uses an edge-coupled interdigital design and the X-band filter uses an end-coupled design. The insertion loss and the noise-temperature contribution were measured at 12 K for both filters.