Search NASA⌕ Search

SEARCH · Search NASA

Results for “installation tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Full-Scale Hydrogen Mitigation Installation and Testing at Nevada Solar One

This project was performed under a Cooperative Research & Development Agreement (CRADA) between the National Renewable Energy Laboratory (NREL) and Acciona Energy USA (AE). The purpose was to advance an NREL TRL 3 technology that was developed during the previous CRADA from completed laboratory testing to full-scale process installation and testing at AE's Nevada Solar One (NSO) power plant. The project's objective was to complete full-scale implementation and performance verification of the NREL hydrogen mitigation technology at the Nevada Solar One (NSO) power plant in Boulder City, Nevada.

08 HYDROGEN↗

Multi-Faceted Approach to Evaluate Discharge Locations at a FUSRAP Site - 18421

Following the completion of a Soil and Groundwater Remedial Investigation by USACE at a FUSRAP site located in Nassau County, New York, groundwater data indicated the presence of contaminant source(s) that had not been identified. As a result, a targeted investigation was undertaken to understand how materials were handled and disposed of at a site located in Nassau County, Long Island, New York. The FUSRAP site is a 4.3-hectare (10.5-acre) site encompassing three parcels which had historically been utilized as a nuclear materials manufacturing facility (e.g., cores, slug, and fuel elements) for reactors used in both research and electric power generation in early 1950's until late 1960's; however, the targeted investigation was on the southern-most parcel known as the '70 Property' (the Site). The 70 Property contained a building that was used for atomic fuel-element manufacturing from 1958 until 1966 under license to the Atomic Energy Commission (AEC), and involved the use of natural, enriched, and depleted uranium as well as lesser amounts of thorium. The major contaminants of concern are tetrachloroethene, nickel, uranium and thorium. During the RI, significant sources of contamination were not found in Site soils despite records indicating that chemicals and radionuclides had been disposed of on the property. In addition, downgradient groundwater data indicated a source(s) on the 70 Property that could not be identified by known sources on other the other FUSRAP parcels or from adjacent sites. This conclusion was further supported following development of groundwater contaminant transport and flow models. The main objective of the targeted investigation was to evaluate the potential discharge points on the 70 Property that may have been utilized for liquids waste disposal. However, several challenges existed including 1) lack of building construction details; 2) historical changes to Site building and property; 3) the use of the Site by various tenants; and 4) the commingling of Site contaminants with impacts from multiple sources. To overcome these challenges, historic documents/reports with information about the handling and disposal of liquid wastes were reviewed to evaluate quantities, contents and locations of waste disposal. Thereafter, an investigation was undertaken that included geophysical surveys; pipe tracing and video inspection; in-situ smoke and water testing; installation of test trenches and soil borings; and, sampling sludge residuals, soils and water within the various drainage structures that were located. This paper describes the multi-faceted investigation approach that was utilized to overcome the challenges faced during the investigation as well as insights into the waste disposal practices of the time period and the findings of the investigation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

U.S. Department of Energy Competitiveness Improvement Project (CIP) 2024 Prototype Installation and Testing Awardee: Accelerate Wind

This fact sheet describes the 2024 Competitiveness Improvement Project (CIP) award received by Accelerate Wind for Prototype Installation and Testing. The U.S. Department of Energy's (DOE's) CIP awards cost-shared subcontracts and technical support to manufacturers of small and medium-sized wind turbines. Managed by NREL on behalf of DOE's Wind Energy Technologies Office, CIP helps advance wind energy as a cost-effective, distributed generation technology option.

17 WIND ENERGY↗

U.S. Department of Energy Competitiveness Improvement Project (CIP) 2024 Prototype Installation and Testing Awardee: Pecos Wind Power

This fact sheet describes the 2024 Competitiveness Improvement Project (CIP) award received by Pecos Wind Power for Prototype Installation and Testing. The U.S. Department of Energy's (DOE's) CIP awards cost-shared subcontracts and technical support to manufacturers of small and medium-sized wind turbines. Managed by NREL on behalf of DOE's Wind Energy Technologies Office, CIP helps advance wind energy as a cost-effective, distributed generation technology option.

17 WIND ENERGY↗

Slow control and TDAQ systems installation and tests in the Mu2e experiment

The Mu2e experiment at Fermilab will attempt to detect a coherent neutrinoless conversion of a muon into an electron in the field of an aluminum nucleus, with a sensitivity that is 10,000 times greater than existing limits. The Mu2e trigger and data acquisition system (TDAQ) uses the otsdaqframework as its online Data Acquisition System (DAQ) solution. Developed at Fermilab, otsdaq integrates several components, such as an artdaq-based DAQ, an art-based event processing, and an EPICS-based detector control system (DCS), and provides a uniform multi-user interface toits components through a web browser. The data streams from the Mu2e tracker and calorimeter are handled by the artdaq-based DAQ and processed by a one-level software trigger implemented within the art framework. Events accepted by the trigger have their data combined, post-trigger, with the separately read-out data from the Mu2e Cosmic Ray Veto system. The foundation of Mu2e DCS, EPICS, an Experimental Physics and Industrial Control System, is an open-source platform for monitoring, controlling, alarming, and archiving. Over the last three years, a prototype ofthe TDAQ and DCS systems has been built and tested at Fermilab’s Feynman Computing Center.Currently, the production system installation is underway. At the end, this work presents a brief update on the installation of racks and DAQ hardware.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VERA Infrastructure

The Virtual Environment for Reactor Applications (VERA) Infrastructure provides the infrastructure to build, configure, test, install, and package for release the VERAS suite of codes that is being developed by the Consortium for the Advanced Simulation of Light-water reactors (CASL). It includes the list of codes that can be built within VERA, the location on the configuration-controlled CASL development computer, the version number used in any particular software installation, the location of the third-party libraries used for testing VERA on a suite of the CASL testing and development computers, and the scripts to configure, build, test, install, and package for release a particular version of VERA. The VERA Infrastructure contains a list of scripts, configuration options, and utilities that are specific to CASL, but contain no physics or numeric, nuclear technology, or encryption technology.

Baird, Mark↗

Status Report: Design and Fabricate Installation-Ready Test Capsule for the In-Situ Measurement of Elastic Properties Using an Optical Fiber-Based Measurement Technique

Microstructure evolution due to irradiation in a nuclear reactor can have a dramatic effect on material properties. A better understanding of this evolution is necessary for developing improved nuclear fuels and materials. The ability to measure such changes in real time is extremely limited due to the harsh conditions, high radiation fields, and limited access of the reactor environment. Through carefully designed experiments, measurement of elastic properties can be tied directly to microstructure. We present the methodology, design, and deployment plan for an instrument that has been developed to monitor grain microstructural changes during irradiation. Our measurement approach involves exciting and measuring the resonant frequency of a thin cantilever beam. Excitation and detection of the flexural vibrations of the beam are accomplished using optical methods that require only an optical fiber connection between the instrumentation and the sample. This technique has been demonstrated in a laboratory setting to monitor the recrystallization of highly textured copper during high temperature annealing. A test capsule incorporating this technique has been developed for in reactor testing. The capsule has been designed to be compatible with a reusable test module that allows simplified insertion in the TREAT reactor at INL. An exact replica of the instrument described in this Status Report, constructed from Quality Level 3 materials, is slated to be inserted into the TREAT reactor in FY19.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cryogenics and purification systems of the ICARUS T600 detector installation at Fermilab

This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, U.S.A. The ICARUS T600 detector is made of four large Time Projection Chambers, installed in two separate containers of about 275 m 3 each. The detector uses liquid argon both as target and as active medium. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions and the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector was previously operated in Italy, at the INFN Gran Sasso Underground Laboratory (LNGS), in a three-year run on the CERN to LNGS Long Baseline Neutrino Beam. For its operation on the Booster and NuMI neutrino beams at Fermilab, for the search of sterile neutrinos and measurements of neutrino-argon cross sections, the detector was moved from Gran Sasso to CERN for the upgrades required for operation at shallow depth with high intensity neutrino beams. The liquid argon containers, the thermal insulation and all the cryogenic equipment have been completely re-designed and rebuilt, following the schemes of the previous installation in Gran Sasso. The detector and all the equipment have been transported to Fermilab, where they have been installed, tested and recently put into operation. The work described in this paper has been conducted as a joint responsibility of CERN and Fermilab with the supervision provided by the ICARUS Collaboration. Design, installation, testing, commissioning and operation are the result of a common effort of CERN, Fermilab and INFN groups.

Cryogenic detectors↗

Gas Atomization Equipment Statement of Work and Specification for Engineering design, Fabrication, Testing, and Installation

The Gas Atomization Equipment will be used to fabricate metallic powder suitable for Powder Bed Fusion additive Manufacturing material to support Lawrence Livermore National Laboratory (LLNL) research and development. The project will modernize our capabilities to develop spherical reactive, refractory, and radioactive powders in the 10-75 μm diameter size range at LLNL.

42 ENGINEERING↗

2021 Prototype Installation and Testing Awardee: XFlow Energy Company

XFlow Energy Company (XFlow Energy) aims to reduce the cost of wind energy by designing vertical-axis wind turbines (VAWTs), which have a cheaper blade manufacturing process and a mechanically simpler design than traditional wind turbines, among other cost-saving advantages. However, a lack of modeling or simulation tools that can predict the coupling between aerodynamic and structural forces poses a significant challenge to developers of VAWTs. Known as aeroelastic models, these are not just important design tools - they're critical for certifying VAWTs of 25 kilowatts (kW), which is the size of XFlow Energy's prototype wind turbine. Without certification, XFlow Energy will not be able to deliver an independently validated product to its customers, and those customers will not be eligible for state and federal incentives. An accurate aeroelastic model could provide less-conservative structural optimization tactics than are currently used, resulting in a wind turbine with lower capital costs.

CIP↗

2022 Prototype Installation and Testing Awardee: Windward Engineering

The 60-kilowatt (kW) Zephyr 21/60 wind turbine from Windward Engineering uses a low-cost, full-span independent pitch system that can act as a redundant aerodynamic braking system. This design uses a relatively simple pneumatic rotary vane actuator, allowing each of the turbine's three blades to be pitched independently and any single blade to activate emergency braking for the entire turbine. A previous Competitiveness Improvement Project (CIP) funding award enabled Windward Engineering to design and develop the Zephyr 21/60 wind turbine's aeroelastic model and pitch system. At the end of this current Competitiveness Improvement Project award, a fully validated aeroelastic model will make it possible to certify Windward Engineering's Zephyr 21/60 design and quantify the technology's levelized cost of energy in preparation for certification and entry into the distributed wind market. The Zephyr 21/60 will feature an attractive levelized cost of energy, improved reliability, and a full-span pitch system for safe and redundant protection against rotor overspeed (which occurs when the rotor turns beyond its design limit).

CIP↗

Automated fault detection and diagnosis of airflow and refrigerant charge faults in residential HVAC systems using IoT-enabled measurements

While automated fault detection and diagnosis (AFDD) in residential heating, ventilation, and air-conditioning (HVAC) using smart thermostat data is gaining increasing attention in recent times, it still requires in-depth investigation for market adoption, especially with real-life data. Furthermore, this paper proposes an Internet of Things (IoT) - based approach that adds a smart sensor to the smart thermostat data to carry out AFDD. The approach uses a model which predicts enthalpy change across the evaporator and compares the prediction to the measured enthalpy change. Deviations which exceed analytically determined thresholds then signal faults in the HVAC system. The faults detected are either installation related or degradation related. Experimental tests were carried out in four homes located in Norman, Oklahoma. From the tests, installation issues like indoor/outdoor mismatch were detected in two homes, while a 30% low charge and low indoor airflow rate were detected in one home. The results show that the proposed AFDD algorithm was able to successfully detect two prevalent faults, namely low indoor airflow and low refrigerant charge. Unlike most of the smart thermostat-based approaches, the proposed IoT-based approach can detect and diagnose both faults but only require one additional sensor which is provided by smart thermostat manufacturers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photovoltaic Shading Testbed for Module-Level Power Electronics: 2016 Performance Data Update

The 2012 NREL report 'Photovoltaic Shading Testbed for Module-Level Power Electronics' provides a standard methodology for estimating the performance benefit of distributed power electronics under partial shading conditions. Since the release of the report, experiments have been conducted for a number of products and for different system configurations. Drawing from these experiences, updates to the test and analysis methods are recommended. Proposed changes in data processing have the benefit of reducing the sensitivity to measurement errors and weather variability, as well as bringing the updated performance score in line with measured and simulated values of the shade recovery benefit of distributed PV power electronics. Also, due to the emergence of new technologies including sub-module embedded power electronics, the shading method has been extended to include power electronics that operate at a finer granularity than the module level. An update to the method is proposed to account for these emerging technologies that respond to shading differently than module-level devices. The partial shading test remains a repeatable test procedure that attempts to simulate shading situations as would be experienced by typical residential or commercial rooftop photovoltaic (PV) systems. Performance data for multiple products tested using this method are discussed, based on equipment from Enphase, Solar Edge, Maxim Integrated and SMA. In general, the annual recovery of shading losses from the module-level electronics evaluated is 25-35%, with the major difference between different trials being related to the number of parallel strings in the test installation rather than differences between the equipment tested. Appendix D data has been added in this update.

14 SOLAR ENERGY↗