More About the Phase-Synchronized Enhancement Method

A report presents further details regarding the subject matter of "Phase-Synchronized Enhancement Method for Engine Diagnostics" (MFS-26435), NASA Tech Briefs, Vol. 22, No. 1 (January 1998), page 54. To recapitulate: The phase-synchronized enhancement method (PSEM) involves the digital resampling of a quasi-periodic signal in synchronism with the instantaneous phase of one of its spectral components. This resampling transforms the quasi-periodic signal into a periodic one more amenable to analysis. It is particularly useful for diagnosis of a rotating machine through analysis of vibration spectra that include components at the fundamental and harmonics of a slightly fluctuating rotation frequency. The report discusses the machinery-signal-analysis problem, outlines the PSEM algorithms, presents the mathematical basis of the PSEM, and presents examples of application of the PSEM in some computational simulations.

Jong, Jen-Yi↗

Digital Doppler measurement with spacecraft

Digital and analog phase-locked loop (PLL) receivers were operated in parallel, each tracking the residual carrier from a spacecraft. The PLL tracked the downlink carrier and measured its instantaneous phase. This information, combined with a knowledge of the uplink carrier and the transponder ratio, permitted the computation of a Doppler observable. In this way, two separate Doppler measurements were obtained for one observation window. The two receivers agreed on the magnitude of the Doppler effect to within 1 mHz. There was less jitter on the data from the digital receiver. This was due to its smaller noise bandwidth. The demonstration and its results are described.

Kinman, Peter W.↗

Helium Cryo Testing of a SLMS(TM) (Silicon Lightweight Mirrors) Athermal Optical Assembly

SLMS (TM) a thermal technology has been demonstrated in the small 4-foot helium cryogenic test chamber located at the NASA/MSFC X-Ray Calibration Facility (XRCF). A SLMS (TM) Ultraviolet Demonstrator Mirror (UVDM) produced by Schafer under a NASA/MSFC Phase I SBIR was helium cryo tested both free standing and bonded to a Schafer designed prototype carbon fiber reinforced silicon carbide (Cesic) mount. Surface figure data was obtained with a test measurement system that featured an Instantaneous Phase Interferometer (IPI) by ADE Phase Shift. The test measurement system s minimum resolvable differential figure deformation and possible contributions from test chamber ambient to cryo window deformation are under investigation. The free standing results showed differential figure deformation of 10.4 nm rms from 295K to 27K and 3.9 nm rms after one cryo cycle. The surface figure of the UVDM degraded by lambda/70 rms HeNe once it was bonded to the prototype Cesic mount. The change was due to a small astigmatic aberration in the rototype Cesic mount due to lack of finish machining and not the bonding technique. This effect was seen in SLMST (TM) optical assembly results, which showed differential figure deformation of 46.5 nm rms from 294K to 27K, 42.9 nm rms from 294K to 77K, 28.0 nm rms from 294K to 193K and 6.2 nm rms after one cryo cycle.

Jacoby, Marc T.↗

Interferometer for Testing in Vibration Environments

Temporal phase shifting interferometers require a stable environment during the data acquisition, so that well controlled phase steps can be introduced between successively acquired interferograms. In contrast, single-frame interferometers need to acquire only one interferogram to provide a phase map with very good precision at high spatial resolution. Thus these interferometers are well suited for the interferometric testing of large optics with long radius of curvature for which vibration isolation is difficult, eg. testing astronomical telescope mirrors in a test tower, or testing space optics inside a cryogenic vacuum chamber. This paper describes the Instantaneous Phase Interferometer (IPI) by ADE Phase Shift, together with measurement results at NASA. The IPI consists of a polarization Twyman-Green interferometer operating at 632.8 nm, with single-frame data acquisition based on a spatial carrier technique. The spatial carrier fringes are generated by introducing large amount of tilt between the test beam and the reference beam. The phase information of the optical surface under test is encoded in the straightness of the interference fringes, which can be detected in a single frame with spatial sampling of 1000 x 1000 pixels. Measurements taken at the NASA Marshall Space Flight Cater in support of the characterization of developmental optics for the Next Generation Space Telescope are presented. Such tests consist of a mirror placed inside a cryogenic vacuum chamber, with the IPI placed outside the test chamber without any additional vibration isolation.

Eng, Ron↗

Amplitude-steered, pseudophased antenna array

Beam may be smoothly scanned around ring array without instantaneous phase transitions while maintaining constant radiated power by gradually transferring power from receding element to element next to leading edge of driven segment, and by accomplishing antenna element switching during intervals when no power is being applied to elements being switched.

Johnson, C. C.↗

Automated nystagmus analysis

Several methods have recently been used for on-line analysis of nystagmus: A digital computer program has been developed to accept sampled records of eye position, detect fast phase components, and output cumulative slow phase position, continuous slow phase velocity, instantaneous fast phase frequency, and other parameters. The slow phase velocity is obtained by differentiation of the calculated cumulative position rather than the original eye movement record. Also, a prototype analog device has been devised which calculates the velocity of the slow phase component during caloric testing. Examples of clinical and research eye movement records analyzed with these devices are shown.

Oman, C. M.↗

MITNYS-II - A digital program for on-line analysis of nystagmus

A digital computer program, MITNYS-II, has been developed for on-line analysis of nystagmus which results from visual, vestibular or caloric stimulation. The program accepts sampled records of eye position and yields cumulative slow phase position, slow phase velocity, instantaneous fast phase frequency and other parameters in 25 ms. In this paper the algorithms by which fast phases are detected, and by which slow phase cumulative eye position is extrapolated across the fast phase interval are described. Extensive tests with vestibular, optokinetic and caloric nystagmus yield reliability figures of the order of 2% for false identification of fast phases and missed fast phases. MITNYS-II has been successfully employed to interpret clinical EOG records, examples of which are presented.

Allum, J. H. J.↗

Lessons Learned During Cryogenic Optical Testing of the Advanced Mirror System Demonstrators (AMSDs)

Optical testing in a cryogenic environment presents a host of challenges above and beyond those encountered during room temperature testing. The Advanced Mirror System Demonstrators (AMSDs) are 1.4 m diameter, ultra light-weight (<20 kg/mA2), off-axis parabolic segments. They are required to have 250 nm PV & 50 nm RMS surface figure error or less at 35 K. An optical testing system, consisting of an Instantaneous Phase Interferometer (PI), a diffractive null corrector (DNC), and an Absolute Distance Meter (ADM), was used to measure the surface figure & radius-of-curvature of these mirrors at the operational temperature within the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center (MSFC). The Ah4SD program was designed to improve the technology related to the design, fabrication, & testing of such mirrors in support of NASA s James Webb Space Telescope (JWST). This paper will describe the lessons learned during preparation & cryogenic testing of the AMSDs.

Hadaway, James↗

Cryogenic Test Results of Hextek Mirror

A 250 mm diameter lightweight borosilicate mirror has been interferometrically tested from room-temperature down to 30 K at the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center (MSFC). The minor blank was manufactured by Hextek Corporation using a high-temperature gas fusion process and was then polished at MSFC. It is a sandwich-type mirror consisting of a thin face-sheet (approx.1.5 mm thick), a core structure (20 mm thick, approx.43 mm diameter cells, & 0.5-1.2 mm thick walls), and a thin back-sheet (3 mm thick). The mirror has a 2500 mm spherical radius-of- curvature @/lo). The areal density is 14 kg/sq m. The mirror was tested in the 1 m x 2 m chamber using an Instantaneous Phase Interferometer (PI) from ADE Phase Shift Technologies. The mirror was tested twice. The first test measured the change in surface figure from ambient to 30 K and the repeatability of the change. An attempt was then made by QED Technologies to cryo-figure the mirror using magnetorheological finishing. The second test measured the effectiveness of the cryo- figuring. This paper will describe the test goals, the test instrumentation, and the test results for these cryogenic tests.

Hadaway, James↗

Characterization of the JWST Pathfinder Mirror Dynamics Using the Center of Curvature Optical Assembly (CoCOA)

The JWST (James Webb Space Telescope) Optical Telescope Element (OTE) consists of a 6.6 meter clear aperture, 18-segment primary mirror, all-reflective, three-mirror anastigmat operating at cryogenic temperatures. To verify performance of the primary mirror, a full aperture center of curvature optical null test is performed under cryogenic conditions in Chamber A at NASA Johnson Space Center using an instantaneous phase measuring interferometer. After phasing the mirrors during the JWST Pathfinder testing, the interferometer is utilized to characterize the mirror relative piston and tilt dynamics under different facility configurations. The correlation between the motions seen on detectors at the focal plane and the interferometer validates the use of the interferometer for dynamic investigations. The success of planned test hardware improvements will be characterized by the multi-wavelength interferometer (MWIF) at the Center of Curvature Optical Assembly (CoCOA).

Wells, Conrad↗

Characterization of the JWST Pathfinder Mirror Dynamics Using the Center of Curvature Optical Assembly (CoCOA)

The JWST (James Webb Space Telescope) Optical Telescope Element (OTE) consists of a 6.6 meter clear aperture, 18-segment primary mirror, all-reflective, three-mirror anastigmat operating at cryogenic temperatures. To verify performance of the primary mirror, a full aperture center of curvature optical null test is performed under cryogenic conditions in Chamber A at NASA Johnson Space Center using an instantaneous phase measuring interferometer. After phasing the mirrors during the JWST Pathfinder testing, the interferometer is utilized to characterize the mirror relative piston and tilt dynamics under different facility configurations. The correlation between the motions seen on detectors at the focal plane and the interferometer validates the use of the interferometer for dynamic investigations. The success of planned test hardware improvements will be characterized by the multi-wavelength interferometer (MWIF) at the Center of Curvature Optical Assembly (CoCOA).

Wells, C.↗

Time-Frequency Analysis of Experimental and Analytical Hub Loads of a Rotor Undergoing a Rotor Speed Change

A two-part analytical study was conducted examining a small-scale, two-bladed rotor undergoing a change in rotor speed in a wind tunnel setting. First, a parametric study was conducted to understand how rotor transient response, determined using a time-marching solution, is affected by the choice of rotor wake model, blade elasticity, and inclusion of an elastic support structure model. The second part of the study compared results from an analytical model of the NASA Multirotor Test Bed (MTB) undergoing a rotor speed change to experimental data. Since the analytical and experimental time histories were non-stationary signals, a Stockwell transform was employed to analyze the data in lieu of traditional Fourier transform-based methods. The analysis included extraction of time-varying frequency content of the rotor thrust and hub motion, damping ratios, instantaneous rotor speed, and instantaneous phase difference between thrust and hub motion. Use of a free wake model was found to be necessary to predict higher-harmonic thrust, however, it underpredicted the amplitude of the unsteady loads. Modeling the elasticity of the stiff rotor blades installed on the MTB resulted in minimal impact on the vibratory loads compared to a rigid blade model. The current analytical model of the MTB, including an elastic support structure, properly predicted the measured trends in the frequency content of the thrust.

Rotor dynamics↗

Time-Frequency Analysis of Experimental and Analytical Hub Loads of a Rotor Undergoing a Rotor Speed Change

A two-part analytical study was conducted examining a small-scale, two-bladed rotor undergoing a change in rotor speed. First, a parametric study was conducted to understand how rotor transient response, determined using a time-marching solution, is affected by the choice of rotor wake model, blade elasticity, and inclusion of an elastic support structure model. The second part of the study compared results from an analytical model of the NASA Multirotor Test Bed (MTB) undergoing a rotor speed change to wind tunnel data. Since the analytical and experimental time histories were nonstationary signals, a Stockwell transform was employed to analyze the data in lieu of traditional Fourier transform-based methods. The analysis included extraction of time-varying frequency content of the rotor thrust and hub motion, damping ratios, instantaneous rotor speed, and instantaneous phase difference between thrust and hub motion. Use of a free wake model was found to be necessary to predict higher-harmonic thrust, however, it underpredicted the amplitude of the unsteady loads. Modeling the elasticity of the stiff rotor blades installed on the MTB resulted in minimal impact on the computed vibratory loads compared to a rigid blade model. The current analytical model of the MTB, including an elastic support structure, properly predicted the measured trends in the frequency content of the thrust.

Martin K Sekula↗

Simultaneous 100-kHz Acetone Planar Laser-Induced Fluorescence and OH* Chemiluminescence in a Linear Non-Premixed Detonation Channel

Reactant mixing and combustion are investigated in an optically accessible, self-excited linear detonation combustor. The mixing field is captured using 100 kHz planar laser-induced fluorescence (PLIF) imaging of acetone as a tracer in the fuel supply, while 100 kHz chemiluminescence imaging of excited-state hydroxyl (OH*) radicals simultaneously resolves the evolution of the detonation wave. Time sequences are acquired over multiple detonation cycles in each test, with acetone-PLIF images collected along multiple orthogonal planes to reveal the complex three-dimensional topography of the fuel distribution. The instantaneous and phase averaged acetone-PLIF images enable measurement of key fuel injection characteristics, such as the injector recovery time, fuel jet velocity, and refill height for a range of operating conditions. Instantaneous and phase-averaged measurements of acetone-PLIF with the time-coincident OH* chemiluminescence images also reveal a number key features, such as fuel stratification and weak detonation in the injector near field, incomplete combustion and deflagration behind the detonation wave, vitiation and deflagration of reactants ahead of the detonation wave, and fuel and oxidizer recovery time mismatch leading to combustion inefficiency. These measurements significantly enhance the ability to obtain detailed information on the intracycle and intercycle spatiotemporal evolution of the reactant refill process and its coupled effects on the detonation wave structure and propagation.

Propulsion↗

Performance characteristics of a slagging gasifier for MHD combustor systems

The performance of a two stage, coal combustor concept for magnetohydrodynamic (MHD) systems was investigated analytically. The two stage MHD combustor is comprised of an entrained flow, slagging gasifier as the first stage, and a gas phase reactor as the second stage. The first stage was modeled by assuming instantaneous coal devolatilization, and volatiles combustion and char gasification by CO2 and H2O in plug flow. The second stage combustor was modeled assuming adiabatic instantaneous gas phase reactions. Of primary interest was the dependence of char gasification efficiency on first stage particle residence time. The influence of first stage stoichiometry, heat loss, coal moisture, coal size distribution, and degree of coal devolatilization on gasifier performance and second stage exhaust temperature was determined. Performance predictions indicate that particle residence times on the order of 500 msec would be required to achieve gasification efficiencies in the range of 90 to 95 percent. The use of a finer coal size distribution significantly reduces the required gasifier residence time for acceptable levels of fuel use efficiency. Residence time requirements are also decreased by increased levels of coal devolatilization. Combustor design efforts should maximize devolatilization by minimizing mixing times associated with coal injection.

Smith, K. O.↗

Long term prediction of roll phase for an undisturbed spinning spacecraft

This paper describes the attitude control of the Pioneer 10 spacecraft since the loss of the sun-sensor signal in late 1983. It is necessary to control the attitude of the spin-stablized spacecraft so as to maintain communications with earth. Roll phase is calculated on earth using data from a science instrument on-board Pioneer 10, the imaging-photopolarimeter, which, along with its other functions, was designed to collect images of Jupiter during encounter in 1973. With calculation of instantaneous roll phase performed only once per week, the spacecraft roll angle can be predicted more than a week ahead for timing reorientation impulses. Attitude reorientation maneuvers based on roll phase predictions have been successfully executed for several years on Pioneer 10. Of 10 maneuvers analyzed in this paper, predictions were made for as many as 10 days in the future based on a roll-phase measurements spanning only 12 days of data. The average maneuver was planned by projecting the roll phase for 3 days (22,000 spacecraft revolutions) and resulted in a maneuver execution phase error of only 11 deg.

Smith, M. A.↗