Search NASA⌕ Search

SEARCH · Search NASA

Results for “instantaneous phase shifting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Compact instantaneous phase-shifting Sagnac interferometer for nanoscale tilt measurement

There is a large inter disciplinary need for high precision angular sensors in state-of-the-art technologies. This particularly applies to optical metrology in the field of Extreme Ultraviolet (EUV) or X-ray where the optics are commonly characterized in terms of slope errors at a nanoradian scale level. Here, in this paper, we present the in-lab development of an angular sensor based on a single reflection compact Sagnac interferometer using instantaneous phase shifting. Our automated prototype and first results show less than 15 nrad RMS repeatability, at least 200 nrad sensitivity and 280 nrad reproducibility over 100 μrad angular range.

36 MATERIALS SCIENCE↗

New Cryogenic Optical Test Capability at Marshall Space Flight Center's Space Optics Manufacturing Technology Center

A new cryogenic optical testing capability exists at Marshall Space Flight Center's Space Optics Manufacturing Technology Center (SOMTC). SOMTC has been performing optical wavefront testing at cryogenic temperatures since 1999 in the X-ray Cryogenic Test Facility's (XRCF's) large vacuum chamber. Recently the cryogenic optical testing capability has been extended to a smaller vacuum chamber. This smaller horizontal cylindrical vacuum chamber has been outfitted with a helium-cooled liner that can be connected to the facility's helium refrigeration system bringing the existing kilowatt of refrigeration capacity to bear on a 1 meter diameter x 2 meter long test envelope. Cryogenic environments to less than 20 Kelvin are now possible in only a few hours. SOMTC's existing instruments (the Instantaneous Phase-shifting Interferometer (IPI) from ADE Phase-Shift Technologies and the PhaseCam from 4D Vision Technologies) view the optic under test through a 150 mm clear aperture BK-7 window. Since activation and chamber characterization tests in September 2001, the new chamber has been used to perform a cryogenic (less than 30 Kelvin) optical test of a 22.5 cm diameter x 127 cm radius of curvature SiO2 mirror, a cryogenic survival (less than 30 Kelvin) test of an adhesive, and a cryogenic cycle (less than 20 Kelvin) test of a ULE mirror. A vibration survey has also been performed on the test chamber. Chamber specifications and performance data, vibration environment data, and limited test results will be presented.

Kegley, Jeff↗

New Cryogenic Optical Test Capability at Marshall Space Flight Center's Space Optics Manufacturing Technology Center

A new cryogenic optical testing capability exists at Marshall Space Flight Center's Space Optics Manufacturing Technology Center (SOMTC). SOMTC has been performing optical wavefront testing at cryogenic temperatures since 1999 in the X-ray Cryogenic Test Facility's (XRCF's) large vacuum chamber. Recently the cryogenic optical testing capability has been extended to a smaller vacuum chamber. This smaller horizontal cylindrical vacuum chamber has been outfitted with a helium-cooled liner that can be connected to the facility's helium refrigeration system bringing the existing kilowatt of refrigeration capacity to bear on a 1 meter diameter x 2 meter long test envelope. Cryogenic environments to less than 20 Kelvin are now possible in only a few hours. SOMTC's existing instruments (the Instantaneous Phase-shifting Interferometer (IPI) from ADE Phase-Shift Technologies and the PhaseCam from 4D Vision Technologies) view the optic under test through a 150 mm clear aperture BK-7 window. Since activation and chamber characterization tests in September 2001, the new chamber has been used to perform a cryogenic (less than 30 Kelvin) optical test of a 22.5 cm diameter x 127 cm radius of curvature Si02 mirror, a cryogenic survival (less than 30 Kelvin) test of an adhesive, and a cryogenic cycle (less than 20 Kelvin) test of a ULE mirror. A vibration survey has also been performed on the test chamber. Chamber specifications and performance data, vibration environment data, and limited test results will be presented.

Kegley, Jeff↗

Interferometer for Testing in Vibration Environments

Temporal phase shifting interferometers require a stable environment during the data acquisition, so that well controlled phase steps can be introduced between successively acquired interferograms. In contrast, single-frame interferometers need to acquire only one interferogram to provide a phase map with very good precision at high spatial resolution. Thus these interferometers are well suited for the interferometric testing of large optics with long radius of curvature for which vibration isolation is difficult, eg. testing astronomical telescope mirrors in a test tower, or testing space optics inside a cryogenic vacuum chamber. This paper describes the Instantaneous Phase Interferometer (IPI) by ADE Phase Shift, together with measurement results at NASA. The IPI consists of a polarization Twyman-Green interferometer operating at 632.8 nm, with single-frame data acquisition based on a spatial carrier technique. The spatial carrier fringes are generated by introducing large amount of tilt between the test beam and the reference beam. The phase information of the optical surface under test is encoded in the straightness of the interference fringes, which can be detected in a single frame with spatial sampling of 1000 x 1000 pixels. Measurements taken at the NASA Marshall Space Flight Cater in support of the characterization of developmental optics for the Next Generation Space Telescope are presented. Such tests consist of a mirror placed inside a cryogenic vacuum chamber, with the IPI placed outside the test chamber without any additional vibration isolation.

Eng, Ron↗

Helium Cryo Testing of a SLMS(TM) (Silicon Lightweight Mirrors) Athermal Optical Assembly

SLMS (TM) a thermal technology has been demonstrated in the small 4-foot helium cryogenic test chamber located at the NASA/MSFC X-Ray Calibration Facility (XRCF). A SLMS (TM) Ultraviolet Demonstrator Mirror (UVDM) produced by Schafer under a NASA/MSFC Phase I SBIR was helium cryo tested both free standing and bonded to a Schafer designed prototype carbon fiber reinforced silicon carbide (Cesic) mount. Surface figure data was obtained with a test measurement system that featured an Instantaneous Phase Interferometer (IPI) by ADE Phase Shift. The test measurement system s minimum resolvable differential figure deformation and possible contributions from test chamber ambient to cryo window deformation are under investigation. The free standing results showed differential figure deformation of 10.4 nm rms from 295K to 27K and 3.9 nm rms after one cryo cycle. The surface figure of the UVDM degraded by lambda/70 rms HeNe once it was bonded to the prototype Cesic mount. The change was due to a small astigmatic aberration in the rototype Cesic mount due to lack of finish machining and not the bonding technique. This effect was seen in SLMST (TM) optical assembly results, which showed differential figure deformation of 46.5 nm rms from 294K to 27K, 42.9 nm rms from 294K to 77K, 28.0 nm rms from 294K to 193K and 6.2 nm rms after one cryo cycle.

Jacoby, Marc T.↗

Cryogenic Test Results of Hextek Mirror

A 250 mm diameter lightweight borosilicate mirror has been interferometrically tested from room-temperature down to 30 K at the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center (MSFC). The minor blank was manufactured by Hextek Corporation using a high-temperature gas fusion process and was then polished at MSFC. It is a sandwich-type mirror consisting of a thin face-sheet (approx.1.5 mm thick), a core structure (20 mm thick, approx.43 mm diameter cells, & 0.5-1.2 mm thick walls), and a thin back-sheet (3 mm thick). The mirror has a 2500 mm spherical radius-of- curvature @/lo). The areal density is 14 kg/sq m. The mirror was tested in the 1 m x 2 m chamber using an Instantaneous Phase Interferometer (PI) from ADE Phase Shift Technologies. The mirror was tested twice. The first test measured the change in surface figure from ambient to 30 K and the repeatability of the change. An attempt was then made by QED Technologies to cryo-figure the mirror using magnetorheological finishing. The second test measured the effectiveness of the cryo- figuring. This paper will describe the test goals, the test instrumentation, and the test results for these cryogenic tests.

Hadaway, James↗

Transitional Bubble in Periodic Flow Phase Shift

One particular characteristic observed in unsteady shear layers is the phase shift relative to the main flow. In attached boundary layers this will have an effect both on the instantaneous skin friction and heat transfer. In separation bubbles the contribution to the drag is dominated by the pressure distribution. However, the most significant effect appears to be the phase shift on the transition process. Unsteady transition behaviour may determine the bursting of the bubble resulting in an un-recoverable full separation. An early analysis of the phase shift was performed by Stokes for the incompressible boundary layer of an oscillating wall and an oscillating main flow. An amplitude overshoot within the shear layer as well as a phase shift were observed that can be attributed to the relatively slow diffusion of viscous stresses compared to the fast change of pressure. Experiments in a low speed facility with the boundary layer of a flat plate were evaluated in respect to phase shift. A pressure distribution similar to that on the suction surface of a turbomachinery aerofoil was superimposed generating a typical transitional separation bubble. A periodically unsteady main flow in the suction type wind tunnel was introduced via a rotating flap downstream of the test section. The experiments covered a range of the three similarity parameters of momentum-loss-thickness Reynolds-number of 92 to 226 and Strouhal-number (reduced frequency) of 0.0001 to 0.0004 at the separation point, and an amplitude range up to 19 %. The free stream turbulence level was less than 1% .Upstream of the separation point the phase shift in the laminar boundary layer does not appear to be affected significantly bay either of the three parameters. The trend perpendicular to the wall is similar to the Stokes analysis. The problem scales well with the wave velocity introduced by Stokes, however, the lag of the main flow near the wall is less than indicated analytically. The separation point comes closest to the Stokes analysis but the phase is still 20 degrees lower at the wall.

Talan, M.↗

Wideband infrared receiver backend

The design, operation, and configuration of the receiver backend for a wideband infrared tracking receiver are described. A squaring loop is incorporated into the receiver design to enable it to track the Doppler shifted carrier which is Phase Shift Keyed modulated. The receiver has a 400 MHz instantaneous bandwidth and tracks signals whose carrier frequency at the backend input is between 200 and 900 MHz with frequency variation rates greater than 20 MHz/second. The output data is compatible with MECL 3 logic.

Flattau, T.↗

Behavior Of Costas Loop In Reception Of Telemetry

Report presents theoretical study of behavior of Costas loop in reception of radio carrier signal modulated in phase by sinusoidal or square-wave subcarrier, further modulated in phase by nonreturn-to-zero binary data signal. Phase and frequency of received signal affected by Doppler shift, and instantaneous amplitude of received signal corrupted by additive white Gaussian noise. Signals of this type ordinarily used in spacecraft telemetry, sine-wave subcarrier being preferred for shorter signal paths and square-wave subcarrier for longer signal paths.

Nguyen, Tien M.↗

Measuring rainwater content by radar using propagation differential phase shift

While radars measure several quantities closely coupled to the rainfall rate, for frequencies less than 15 GHz, estimates of the rainwater content W are traditionally computed from the radar reflectivity factor Z or the rate of attenuation A--quantities only weakly related to W. Consequently, instantaneous point estimates of W using Z and A are often erroneous. A more natural, alternative parameter for estimating W at these frequencies is the specific polarization propagation differential phase shift phi(sub DP), which is a measure of the change in the difference between phases of vertically (V) and horizontally (H) polarized waves with increasing distance from a radar. It is now well known that W is nearly linearly related to phi(sub DP) divided by (1 - reversed R), where reversed R is the mass-weighted mean axis ratio of the raindrops. Unfortunately, such relations are not widely used in part because measurements of phi(sub DP) are scarce but also because one must determine reversed R. In this work it is shown that this parameter can be estimated using the differential reflectivity (Z(sub H)/Z(sub V) at 3 GHz. An alternative technique is suggested for higher frequencies when the differential reflectivity becomes degraded by attenuation. While theory indicates that it should be possible using phi(sub DP) to estimate W quite accurately, measurement errors increase the uncertainty to +/- 18%-35% depending on reversed R. While far from ideal, it appears that these estimates are likely to be considerably more accurate than those deduced using currently available methods.

Jameson, A. R.↗

Measurement System and Method

System and methods are disclosed for fluid measurements which may be utilized to determine mass flow rates such as instantaneous mass flow of a fluid stream. In a preferred embodiment, the present invention may be utilized to compare an input mass flow to an output mass flow of a drilling fluid circulation stream. In one embodiment, a fluid flow rate is determined by utilizing a microwave detector in combination with an acoustic sensor. The acoustic signal is utilized to eliminate 2pi phase ambiguities in a reflected microwave signal. In another embodiment, a fluid flow rate may be determined by detecting a phase shift of an acoustic signal across two different predetermined transmission paths. A fluid density may be determined by detecting a calibrated phase shift of an acoustic signal through the fluid. In another embodiment, a second acoustic signal may be transmitted through the fluid to define a particular 2pi phase range which defines the phase shift. The present invention may comprise multiple transmitters/receivers operating at different frequencies to measure instantaneous fuel levels of cryogenic fuels within containers positioned in zero or near zero gravity environments. In one embodiment, a moveable flexible collar of transmitter/receivers may be utilized to determine inhomogenuities within solid rocket fuel tubes.

G Dickey Arndt↗

Holographic interferometric tomography for reconstructing flow fields

Holographic interferometric tomography is a technique for instantaneously capturing and quantitatively reconstructing three-dimensional flow fields. It has a very useful application potential for high-speed aerodynamics. However, three major challenging tasks need to be accomplished before its practical applications. First, fluid flows are mostly unsteady or at least non repeatable. Consequently, a means for Instantaneously recording three-dimensional flow fields, that is, a simple holographic technique for simultaneously recording multi-directional projections, needs to be developed. Second, while holographic interferometry provides enormous data storage capabilities, expeditious data extraction from complicated interferograms is very important for timely near real-time applications. Third, unlike medical applications, flow tomography does not provide complete data sets but instead involves ill-posed reconstruction problems of incomplete projection and limited angular scanning. During this summer research period, new experimental techniques and corresponding hardware were developed and tested to address the above mentioned tasks. The first task was achieved by diffuser illumination. This concept allows instantaneous capture of many projections with a conventional setup for single-projection recording. For the second task, a phase-shifting technique was incorporated. This technique allows one to acquire multiple phase-stepped interferograms for a single projection and thus to extract phase information from intensity data almost at real-time. For the third task, the research that has been extensively conducted previously was utilized. In this research period, a complete experimental setup that provides the above three major capabilities was designed, built, and tested by integrating all the techniques. A simple laboratory experiment for simulating wind-tunnel testing was then conducted. A test flow was produced by employing a relatively simple device that generated a gravity-driven flow. The flow was then experimentally investigated to check the viability of the holographic interferometric tomographic technique before wind-tunnel application.

Cha, Soyoung S.↗

Forecasts of the 500 mb height using a dynamically oriented statistical model

The forecast skill of a simple dynamically inspired statistical model of the Northern Hemisphere 500 mb height field is evaluated in spectral and physical space for a variety of forecast lead times (1-32 days) and predictand averaging times (1-32 days). The model includes viscous damping, wave propagation, climatology and implicit stochastic forcing. The largest model skill was found for forecasts of the zonal flow and the largest waves. In general, the largest forecast skills were also associated with the largest forecast error, there being a slight geographic phase shift of the skill with respect to the error. Model skills for climate (time-averaged) forecasts are greater when using instantaneous rather than time averages to forecast time averages. Analysis of model errors suggests areas for improvement in representing forcing terms and model physics. However, the model error fields are largely 'white noise' which suggests that global forecast skills substantially larger than those obtained here are unlikely to be achieved by more sophisticated models.

Roads, J. O.↗

The roles of photochemical and non-photochemical quenching in regulating photosynthesis depend on the phases of fluctuating light conditions

We report the induction and relaxation of photochemistry and non-photochemical quenching (NPQ) are not instantaneous and require time to respond to fluctuating environments. There is a lack of integrated understanding on how photochemistry and NPQ influence photosynthesis in fluctuating environments. We measured the induction and relaxation of chlorophyll a fluorescence and gas exchange in poplar and cotton at varying temperatures under saturating and fluctuating lights. When the light shifted from dark to high, the fraction of open reaction centers in photosystem II (q L ) gradually increased while NPQ increased suddenly and then remained stable. Temperature significantly changed the response of q L but not that of NPQ during the dark to high light transition. Increased q L led to higher photosynthesis but their precise relationship was affected by NPQ and temperature. q L was significantly related to biochemical capacity. Thus, q L appears to be a strong indicator of the activation of carboxylase, leading to the similar dynamics between q L and photosynthesis. When the light shifted from high to low intensity, NPQ is still engaged at a high level, causing a stronger decline in photosynthesis. Our finding suggests that the dynamic effects of photochemistry and NPQ on photosynthesis depend on the phases of environmental fluctuations and interactive effects of light and temperature. Across the full spectra of light fluctuation, the slow induction of q L is a more important limiting factor than the slow relaxation of NPQ for photosynthesis in typical ranges of temperature for photosynthesis. The findings provided a new perspective to improve photosynthetic productivity with molecular biology under natural fluctuating environments.

59 BASIC BIOLOGICAL SCIENCES↗

Large aperture interferometer with phase-conjugate self-reference beam

A large aperture self-referencing interferometer consisting of a Twyman-Green interferometer using a self-pumped phase conjugator in series with test section optics is described and experimentally demonstrated. This interferometer provides twice the fringe shift of a Mach-Zehnder (M-Z) interferometer for a given optical phase change induced within the test section. It also provides greater irradiance in the reference beam than does a similar series setup utilizing a M-Z interferometer incorporating a local reference beam. Whereas the ordinary interferometer records instantaneous conditions, the new one records overage conditions if a BaTiO3 crystal is used as the phase conjugator.

Howes, W. L.↗

Secondary Inorganic Aerosol Chemistry and Its Impact on Atmospheric Visibility Over an Ammonia-Rich Urban Area in Central Taiwan

This study investigated the hourly inorganic aerosol chemistry and its impact on atmospheric visibility over an urban area in Central Taiwan, by relying on measurements of aerosol light extinction, inorganic gases, and PM 2.5 water-soluble ions (WSIs), and simulations from a thermodynamic equilibrium model. On average, the sulfate (SO 4 2− ), nitrate (NO 3 − ), and ammonium (NH 4 + ) components (SNA) contributed ∼90% of WSI concentrations, which in turn made up about 50% of the PM 2.5 mass. During the entire observation period, PM 2.5 and SNA concentrations, aerosol pH, aerosol liquid water content (ALWC), and sulfur and nitrogen conversion ratios all increased with decreasing visibility. In particular, the NO 3 − contribution to PM 2.5 increased, whereas the SO 4 2− contribution decreased, with decreasing visibility. The diurnal variations of the above parameters indicate that the interaction and likely mutual promotion between NO 3 − and ALWC enhanced the hygroscopicity and aqueous-phase reactions conducive for NO 3 − formation, thus led to severely impaired visibility. The high relative humidity (RH) at the study area (average 70.7%) was a necessary but not sole factor leading to enhanced NO 3 − formation, which was more directly associated with elevated ALWC and aerosol pH. Simulations from the thermodynamic model depict that the inorganic aerosol system in the study area was characterized by fully neutralized SO 4 2− (i.e. a saturated factor in visibility reduction) and excess NH 4 + amidst a NH 3 -rich environment. As a result, PM 2.5 composition was most sensitive to gas-phase HNO 3 , and hence NOx, and relatively insensitive to NH 3 . Consequently, a reduction of NOx would result in instantaneous cuts of NO 3 − , PM 2.5 , and ALWC, and hence improved visibility. On the other hand, a substantial amount of NH 3 reduction (>70%) would be required to lower the aerosol pH, driving more than 50% of the particulate phase NO 3 − to the gas phase, thereby making NH 3 a limiting factor in shifting PM 2.5 composition.

aerosol chemistry↗

Kinematic principles of primate rotational vestibulo-ocular reflex. II. Gravity-dependent modulation of primary eye position

The kinematic constraints of three-dimensional eye positions were investigated in rhesus monkeys during passive head and body rotations relative to gravity. We studied fast and slow phase components of the vestibulo-ocular reflex (VOR) elicited by constant-velocity yaw rotations and sinusoidal oscillations about an earth-horizontal axis. We found that the spatial orientation of both fast and slow phase eye positions could be described locally by a planar surface with torsional variation of <2.0 +/- 0.4 degrees (displacement planes) that systematically rotated and/or shifted relative to Listing's plane. In supine/prone positions, displacement planes pitched forward/backward; in left/right ear-down positions, displacement planes were parallel shifted along the positive/negative torsional axis. Dynamically changing primary eye positions were computed from displacement planes. Torsional and vertical components of primary eye position modulated as a sinusoidal function of head orientation in space. The torsional component was maximal in ear-down positions and approximately zero in supine/prone orientations. The opposite was observed for the vertical component. Modulation of the horizontal component of primary eye position exhibited a more complex dependence. In contrast to the torsional component, which was relatively independent of rotational speed, modulation of the vertical and horizontal components of primary position depended strongly on the speed of head rotation (i.e., on the frequency of oscillation of the gravity vector component): the faster the head rotated relative to gravity, the larger was the modulation. Corresponding results were obtained when a model based on a sinusoidal dependence of instantaneous displacement planes (and primary eye position) on head orientation relative to gravity was fitted to VOR fast phase positions. When VOR fast phase positions were expressed relative to primary eye position estimated from the model fits, they were confined approximately to a single plane with a small torsional standard deviation ( approximately 1.4-2.6 degrees). This reduced torsional variation was in contrast to the large torsional spread (well >10-15 degrees ) of fast phase positions when expressed relative to Listing's plane. We conclude that primary eye position depends dynamically on head orientation relative to space rather than being fixed to the head. It defines a gravity-dependent coordinate system relative to which the torsional variability of eye positions is minimized even when the head is moved passively and vestibulo-ocular reflexes are evoked. In this general sense, Listing's law is preserved with respect to an otolith-controlled reference system that is defined dynamically by gravity.

NASA Discipline Neuroscience↗

Forward modeling of Doppler velocity interferometer system for improved shockwave measurements

We report that when near-instantaneous shocks are recorded by using a Doppler velocity interferometer velocity interferometer system for any reflector (VISAR), they typically exceed the detector’s ability to react and “skipped fringes” result, where its visibility briefly reduces. Traditionally, replacing skipped fringes required guesswork in analysis, which increased arrival time errors. Second, the use of long but velocity-sensitive interferometer delays with fast detectors which can resolve the delay has traditionally been avoided because of the fear of confusing the arrival time signal. However, shorter delays produce smaller fringe phase shifts per velocity and, thus, can decrease velocity precision. We realize that while some loss of fringe information occurs at shock events, this is often just a partial loss and the residual fringe information can still hold valuable information. We describe a forward model (FM) of the interferometer action and detector blurring that assists with VISAR fringe analysis at skipping events: (1) more precise shock arrival times, (2) arrival time precision not limited by long delays, and (3) improved ghost subtraction, which improves accuracy over a broad time region. Lastly, we demonstrate the utility of a FM on National Ignition Facility and Laboratory for Laser Energetics Omega shots and discuss data process methods to increase the high time resolution of VISAR systems despite their limitations and complexities.

47 OTHER INSTRUMENTATION↗