NASA airborne satellite instrumentation calibrator (NASIC) technical reference

The NASA Satellite Instrumentation Calibrator (NASIC) is a visible and near-infrared spectrometer used to calibrate various satellite instruments by underflying those instruments in a NASA ER-2 aircraft. The calibration instrument's hardware and software are documented. The design, operation, and function of an Ebert-Fastie monochronomator, which by means of a moveable diffraction grating, becomes a visible and near-infrared spectrometer used to calibrate satellite-borne instruments by high altitude underflights in the NASA ER-2.

Ward, John L.↗

Radio metric errors due to mismatch and offset between a DSN antenna beam and the beam of a troposphere calibration instrument

Two components of the error of a troposphere calibration measurement were quantified by theoretical calculations. The first component is a beam mismatch error, which occurs when the calibration instrument senses a conical volume different from the cylindrical volume sampled by a Deep Space Network (DSN) antenna. The second component is a beam offset error, which occurs if the calibration instrument is not mounted on the axis of the DSN antenna. These two error sources were calculated for both delay (e.g., VLBI) and delay rate (e.g., Doppler) measurements. The beam mismatch error for both delay and delay rate drops rapidly as the beamwidth of the troposphere calibration instrument (e.g., a water vapor radiometer or an infrared Fourier transform spectrometer) is reduced. At a 10-deg elevation angle, the instantaneous beam mismatch error is 1.0 mm for a 6-deg beamwidth and 0.09 mm for a 0.5-deg beam (these are the full angular widths of a circular beam with uniform gain out to a sharp cutoff). Time averaging for 60-100 sec will reduce these errors by factors of 1.2-2.2. At a 20-deg elevation angle, the lower limit for current Doppler observations, the beam-mismatch delay rate error is an Allan standard deviation over 100 sec of 1.1 x 10(exp -14) with a 4-deg beam and 1.3 x 10(exp -l5) for a 0.5-deg beam. A 50-m beam offset would result in a fairly modest (compared to other expected error sources) delay error (less than or equal to 0.3 mm for 60-sec integrations at any elevation angle is greater than or equal to 6 deg). However, the same offset would cause a large error in delay rate measurements (e.g., an Allan standard deviation of 1.2 x 10(exp -14) over 100 sec at a 20-deg elevation angle), which would dominate over other known error sources if the beamwidth is 2 deg or smaller. An on-axis location is essential for accurate troposphere calibration of delay rate measurements. A half-power beamwidth (for a beam with a tapered gain profile) of 1.2 deg or smaller is desired for calibration of all types of radio metrics. A water-vapor radiometer calibration beam of this size with very low sidelobes would require a clear aperture antenna with a diameter of at least 1.5 m if the primary water vapor sensing channel were in the 20-22 GHz range.

R P Linfield↗

Evaluation of two gas-dilution methods for instrument calibration

Two gas dilution methods were evaluated for use in the calibration of analytical instruments used in air pollution studies. A dual isotope fluorescence carbon monoxide analyzer was used as the transfer standard. The methods are not new but some modifications are described. The rotary injection gas dilution method was found to be more accurate than the closed loop method. Results by the two methods differed by 5 percent. This could not be accounted for by the random errors in the measurements. The methods avoid the problems associated with pressurized cylinders. Both methods have merit and have found a place in instrument calibration work.

Evans, A., Jr.↗

Apollo experience report: Flight instrumentation calibration

Three types of instrumentation-calibration data were used in the Apollo Program to provide the correct engineering data for tests and mission support. The command and service module instrumentation-component procurement specifications required individual-component calibration, and calibration data for these individual components (conventional-calibration data) were always used for mission data support. A mean standard type of calibration data derived from a statistical sampling of conventional-calibration data was used for test and checkout during the latter part of the Apollo Program. The lunar module instrumentation procurement specification permitted the use of standard-calibration data. These data were applicable to similarly instrumented measurements. The definition, merit, and application of each type of data are discussed.

Demoss, J. F.↗

USE OF THE SDO POINTING CONTROLLERS FOR INSTRUMENT CALIBRATION MANEUVERS

During the science phase of the Solar Dynamics Observatory mission, the three science instruments require periodic instrument calibration maneuvers with a frequency of up to once per month. The command sequences for these maneuvers vary in length from a handful of steps to over 200 steps, and individual steps vary in size from 5 arcsec per step to 22.5 degrees per step. Early in the calibration maneuver development, it was determined that the original attitude sensor complement could not meet the knowledge requirements for the instrument calibration maneuvers in the event of a sensor failure. Because the mission must be single fault tolerant, an attitude determination trade study was undertaken to determine the impact of adding an additional attitude sensor versus developing alternative, potentially complex, methods of performing the maneuvers in the event of a sensor failure. To limit the impact to the science data capture budget, these instrument calibration maneuvers must be performed as quickly as possible while maintaining the tight pointing and knowledge required to obtain valid data during the calibration. To this end, the decision was made to adapt a linear pointing controller by adjusting gains and adding an attitude limiter so that it would be able to slew quickly and still achieve steady pointing once on target. During the analysis of this controller, questions arose about the stability of the controller during slewing maneuvers due to the combination of the integral gain, attitude limit, and actuator saturation. Analysis was performed and a method for disabling the integral action while slewing was incorporated to ensure stability. A high fidelity simulation is used to simulate the various instrument calibration maneuvers.

Vess, Melissa F.↗

Satellite Instrument Calibration for Measuring Global Climate Change. Report of a Workshop at the University of Maryland Inn and Conference Center, College Park, MD. , November 12-14, 2002

Measuring the small changes associated with long-term global climate change from space is a daunting task. To address these problems and recommend directions for improvements in satellite instrument calibration some 75 scientists, including researchers who develop and analyze long-term data sets from satellites, experts in the field of satellite instrument calibration, and physicists working on state of the art calibration sources and standards met November 12 - 14, 2002 and discussed the issues. The workshop defined the absolute accuracies and long-term stabilities of global climate data sets that are needed to detect expected trends, translated these data set accuracies and stabilities to required satellite instrument accuracies and stabilities, and evaluated the ability of current observing systems to meet these requirements. The workshop's recommendations include a set of basic axioms or overarching principles that must guide high quality climate observations in general, and a roadmap for improving satellite instrument characterization, calibration, inter-calibration, and associated activities to meet the challenge of measuring global climate change. It is also recommended that a follow-up workshop be conducted to discuss implementation of the roadmap developed at this workshop.

NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY (NI↗

NASA Aircraft-Satellite Instrument Calibration Project

Ground based prelaunch calibration of satellite instruments usually is not adequate to provide an accurate characterization of the in-orbit performance of a satellite instrument. This is because the ground calibrations may not simulate the in-orbit environment observations of the satellite sensor, or because the sensor characteristics have changed during launch and in-orbit operations. One technique to obtain a meaningful in-orbit calibration of satellite sensors is to acquire simultaneous observations of an Earth scene with the satellite and a well calibrated aircraft or shuttle sensor which has similar characteristics to the satellite sensor. This is a direct in-orbit calibration technique and is usually called vicarious calibration. The experiment with the control instrument must occur above the sensible atmosphere as measured by the satellite sensor to provide a useful improvement to the calibration of the satellite sensor. Some observations on the experiments are made.

Guenther, B. W.↗

Solar-Stellar Irradiance Comparison Experiment 1. II - Instrument calibrations

The science objective for the Solar-Stellar Irradiance Comparison Experiment (SOLSTICE) is to accurately measure the full disk solar spectral irradiance in the ultraviolet (UV) spectral region over a long time period. The SOLSTICE design was driven by the requirement for long-term, precise solar photometry conducted from space. The SOLSTICE 1 is on the Upper Atmosphere Research Satellite (UARS), launched in September 1991 with the possibility for a 10-year operational mission. The in-flight calibration for SOLSTICE to meet its primary objective is the routine measurements of the UV radiation from a set of early-type stars, using the identical optical elements employed for the solar observations. The extensive preflight calibrations of the instrument have yielded a precise characterization of the three SOLSTICE channels. Details of the preflight and in-flight SOLSTICE calibrations are discussed in this paper.

Woods, Thomas N.↗

Satellite Instrument Calibration

Satellite remote sensing is an integral part of global earth observation. Satellite remote sensing data enable us to observe the whole globe at a reasonably high frequency. To maintain the accuracy of satellite remote sensing data, it is critical to continuously perform instrument calibration throughout the lifetime of the mission. This presentation describes the common characteristics of earth observing satellite sensors, the calibration processes and potential issues, the implication on science data, and how we understand the globe.

calibration↗

A Preliminary Study of Inter-Facility LWC Differences in Appendix C and Supercooled Large Drop Conditions due to Calibration Instruments

The simulation of clouds containing Supercooled Large Droplets has received increasing attention due to the introduction of Appendix O and future associated requirements for means of compliance. Supercooled Large Droplet conditions can cover four orders of magnitude in drop sizes, imposing a larger instrument measurement challenge than for Appendix C conditions. Wind tunnel facilities have adopted different instrumentation for liquid water content measurement, with fundamentally different principles of operation. In order to explore the comparability of the different instruments used for Appendix C and SLD measurement, and its impact on confidence in measurements used for means of compliance, a project was established to conduct a series of dedicated tests at three wind tunnel facilities. To date, liquid water content measurements have been completed using a Multi-Element sensor as the common instrument at two of the facilities. The data have provided preliminary information suggesting that substantial inter-facility differences likely exist in liquid water content estimates in Supercooled Large Droplet conditions that appear to be largely attributable to the choice of calibration instruments. These results are dependent on the assumption that the Multi-Element probe would produce equivalent measurements at the two facilities if the liquid water content were the same, regardless of other environmental differences that may exist between the two facilities. Planned further testing with other liquid water content measurement techniques may provide further information to confirm or refute the results of this study.

aircraft icing↗

A Preliminary Study of Inter-Facility LWC Differences in Appendix C and Supercooled Large Droplet Conditions due to Calibration Instruments

The simulation of clouds containing Supercooled Large Droplets has received increasing attention due to the introduction of Appendix O and future associated requirements for means of compliance. Supercooled Large Droplet conditions can cover four orders of magnitude in drop sizes, imposing a larger instrument measurement challenge than for Appendix C conditions. Wind tunnel facilities have adopted different instrumentation for liquid water content measurement, with fundamentally different principles of operation. In order to explore the comparability of the different instruments used for Appendix C and SLD measurement, and its impact on confidence in measurements used for means of compliance, a project was established to conduct a series of dedicated tests at three wind tunnel facilities. To date, liquid water content measurements have been completed using a Multi-Element sensor as the common instrument at two of the facilities. The data have provided preliminary information suggesting that substantial inter-facility differences likely exist in liquid water content estimates in Supercooled Large Droplet conditions that appear to be largely attributable to the choice of calibration instruments. These results are dependent on the assumption that the Multi-Element probe would produce equivalent measurements at the two facilities if the liquid water content were the same, regardless of other environmental differences that may exist between the two facilities. Planned further testing with other liquid water content measurement techniques may provide further information to confirm or refute the results of this study.

aircraft icing↗

Lunar Crater Observation and Sensing Satellite (LCROSS) Instrument Calibration Summary

This document describes the calibration of the LCROSS instruments. It will be released to the public via the Planetary Data System. We need a quick review, if possible, because the data has been delivered to the PDS, and this document is needed to interpret the LCROSS impact data fully. [My mistake [shirley) in not realizing this needed to be treated as a normal publication.] The LCROSS instruments are commercially available units except for one designed and built at Ames. The commercially available instruments don't seem to me to present ITAR issues (Sony video camera, thermal camera from England, and so on.) Also, the internal design details of the instruments are not included in this report, only the process of calibrating them against standard targets. Only very high-level descriptions of the spacecraft are included, comparable to the level of detail included in the public web pages on nasa.gov.

Smith, Kimberly Ennico↗

Positioning system for single or multi-axis sensitive instrument calibration and calibration system for use therewith

A positioning and calibration system are provided for use in calibrating a single or multi axis sensitive instrument, such as an inclinometer. The positioning system includes a positioner that defines six planes of tangential contact. A mounting region within the six planes is adapted to have an inclinometer coupled thereto. The positioning system also includes means for defining first and second flat surfaces that are approximately perpendicular to one another with the first surface adapted to be oriented relative to a local or induced reference field of interest to the instrument being calibrated, such as a gravitational vector. The positioner is positioned such that one of its six planes tangentially rests on the first flat surface and another of its six planes tangentially contacts the second flat surface. A calibration system is formed when the positioning system is used with a data collector and processor.

Finley, Tom D.↗

AVHRR and VISSR satellite instrument calibration results for both Cirrus and marine stratocumulus IFO periods

Accurate characterizations of some cloud parameters are dependent upon the absolute accuracy of satellite radiance measurements. Visible wavelength measurements from both the AVHRR and VISSR instruments are often used to study cloud characteristics. Both of these instruments were radiometrically calibrated prior to launch, but neither has an onboard device to monitor degradation after launch. During the FIRE/SRB cirrus Intensive Field Operation (IFO), a special effort was made to monitor calibration of these two instruments onboard the NOAA-9 and GOES-6 spacecraft. In addition, several research groups have combined their efforts to assess the long-term performance of both instruments. These results are presented, and a limited comparison is made with the ERBE calibration standard.

Whitlock, C. H.↗

Spacecraft instrument calibration and stability

The following topics are covered: instrument degradation; the Solar Backscatter Ultraviolet (SBUV) Experiment; the Total Ozone Mapping Spectrometer (TOMS); the Stratospheric Aerosol and Gas Experiment 1 (SAGE-1) and SAGE-2 instruments; the Solar Mesosphere Explorer (SME) UV ozone and near infrared airglow instruments; and the Limb Infrared Monitor of the Stratosphere (LIMS).

Gille, J. C.↗