Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrument flight software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A holistic approach to the optimization of neutron beam transport at the LANSCE facility

An advanced neutron beam collimation system has been developed as part of an effort to optimize neutron beam transport at the Weapons Neutron Research (WNR) Facility, located within the Los Alamos Neutron Science Center (LANSCE). The goal of this work was to develop and demonstrate techniques to tailor neutron delivery in order to provide maximum available flux on sample with a specific beam profile, while simultaneously reducing unwanted background. A holistic approach was taken, upgrading the facility spallation target, facility metrology infrastructure, and flight path shutter insert to support the implementation of this advanced collimation system. Here, modern instruments and software were employed to conduct facility surveys, characterization of as-built geometry of critical components, 3D ray tracing and neutron transport calculations. Beam images and flux measurements were acquired after installation to evaluate the performance of the collimation system and to demonstrate consistent agreement with MCNP simulations which showed an 87% increase of flux on sample while providing suppression of background neutron impingement on the sample frame by 10 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the EarthSHAB Stratospheric Solar Hot Air Balloon Flight Prediction Model Using Balloon Trajectory Data

Abstract The heliotrope is a solar balloon design which is constructed out of painter’s plastic, and the exterior is coated in charcoal powder. Darkening the plastic gives the balloon a high solar absorptance, which allows it to ascend into the lower stratosphere and float for hours at a time. The balloons have previously been used to lift scientific instruments into the stratosphere to study chemical explosions, earthquakes, and stratospheric aerosols. They have also been proposed as a platform for planetary exploration. Flight predictions are crucial to preflight planning to reduce safety risks and meet flight objectives. However, there exists a wide range of possible flight paths due to varying environmental conditions and solar balloon configurations. EarthSHAB is one such software that was designed to support flight planning using the weather forecasts and balloon properties to predict the flight path of a solar balloon. We compare EarthSHAB-simulated flight paths to a set of observed flight paths for the 3.5-m diameter heliotrope design called the “Cloudskimmer.” Using the criteria that the modeled paths must fall within 5% of the observations to be considered successful, we found that EarthSHAB successfully predicted the Cloudskimmer ascent rate and average float altitude 10% and 90% of the time, respectively. We also found that the average difference in the observed and predicted landing locations was 97 km and landing times were 54 ± 38 min. Significant deviations between the observed and predicted ascent rates and excursions at float were found to be associated with heavy payloads and convective cloud development, respectively. Significance Statement Solar balloons are used to lift scientific instruments into the lower stratosphere for hours at a time to study chemical explosions, earthquakes, stratospheric aerosols, and more. The flight paths of solar balloons can be difficult to predict due to variability in their design and surrounding environment. We evaluate the accuracy of EarthSHAB, a software that predicts the altitude profile and horizontal trajectory of a solar balloon using inputs such as the weather, balloon size, and balloon mass. Our results suggest that for the balloon design used in this study, EarthSHAB is best suited for modeling the behavior of balloons with lightweight payloads that do not fly within or directly above clouds.

Lien, Jessica M. [Sandia National Laboratories, Al↗

Mini Micropulse Lidar measurements in vertical and scanning modes

The Atmospheric Radiation Measurement (ARM) program operates ten Sigma Space (currently Droplet Measurement Technologies/DMT) micropulse lidar systems (MPL-4B-IDS/POL-FS series), which detect the backscattered light in two orthogonal linear polarization channels allowing to distinguish between spherical (e.g. water) and non-spherical (e.g. ice) scattering particles. The ARM MPLs have been providing valuable measurements to the aerosol and cloud research community for well over a decade. DMT’s Mini-Micropulse lidar (MiniMPL) is a compact version of the standard MPL. It reduces the power-aperture product to minimize cost, size, weight, power requirements and has all the electronics integrated with optics in a single box. Although as a result, it has a lower detection range than the MPL, limiting the measurements to the troposphere, its performance is promised to match that of the standard MPL within the troposphere. The MiniMPL weighs 13 kg, and the complete system, consisting of an optical transceiver and a laptop running the data acquisition and post-processing software, fits in a storm case, allowing its transport on domestic or international flights. This can be especially valuable for short field campaigns or Intensive Operational Periods, where time is of the essence when replacing a faulty instrument. In addition, the scanning polarization lidar capability (MiniMPL-SCAN option) could be of great interest for satisfying ARM measurement needs for certain research topics related to clouds and precipitation. To evaluate its full potential in comparison with co-located remote sensing instruments including the ARM MPL-4B-IDS/POL-FS at SGP, a miniMPL was hosted at the ARM Southern Great Plains (SGP) mega-site in 2020 for approximately 3 months. During this time the miniMPL was tested in both vertical sampling and scanning modes.

54 ENVIRONMENTAL SCIENCES↗

Texture measurements on quartz single crystals to validate coordinate systems for neutron time-of-flight texture analysis

In crystallographic texture analysis, ensuring that sample directions are preserved from experiment to the resulting orientation distribution is crucial to obtain physical meaning from diffraction data. This work details a procedure to ensure instrument and sample coordinates are consistent when analyzing diffraction data with a Rietveld refinement using the texture analysis software MAUD . A quartz crystal is measured on the HIPPO diffractometer at Los Alamos National Laboratory for this purpose. The methods described here can be applied to any diffraction instrument measuring orientation distributions in polycrystalline materials.

36 MATERIALS SCIENCE↗

Coupling of high-resolution mass spectrometer and photosynthesis system for comprehensive leaf volatile metabolite profiling

Background Leaf-level biogenic volatile organic compounds (BVOCs) emissions represent a major source of organic gases in the atmosphere, influencing both climate and air quality. These emissions are strongly driven by environmental perturbations, which affect individual plant- to ecosystem-level processes. Uncovering all the BVOCs and understanding how their emissions respond to altered environmental conditions provide critical insights into vegetation-driven changes in atmospheric chemistry. We developed a tandem instrumentation setup that integrates a proton transfer reaction time-of-flight mass spectrometer (PTR-ToF-MS) with parts-per-trillion detection limits and a photosynthetic infrared gas exchange system for the untargeted survey of all the BVOCs. This novel system enables simultaneous, real-time monitoring of BVOC emissions and photosynthetic parameters at the leaf level, offering new opportunities to disentangle the physiological and environmental drivers of VOC release. Furthermore, we established the VOC Analysis and Processing Optimization Resource (VAPOR), an open-access software tool designed for rapid data post-processing and the analysis of the variability of hundreds of BVOCs. We assessed the performance of the tandem system under varying background conditions, using standard gas mixtures and a range of environmental factors. Results Blank emissions were substantially lower for major BVOCs (e.g., isoprene) compared to those observed in plant emissions. Despite this, the observation of background-level VOCs highlights the importance of routinely acquiring and accounting for blank measurements in analyses using the coupled instrumentation. Introduction of known VOC concentrations to the system demonstrated a linear response across different compounds with varying molecular compositions, indicating minimal gas loss regardless of chemical moieties within the coupled instrumentation. We applied the optimized system to investigate the physiological mechanisms driving BVOC emissions across different genotypes of poplar and pennycress. The high mass resolution capabilities of the PTR-ToF-MS, coupled with comprehensive VAPOR-driven data analysis, enabled the identification of several important BVOCs, including methanol and methanethiol; these BVOCs displayed substantial variation across pennycress genotypes and showed concentrations ~ 100–350% higher than the blank. Moreover, isoprene emissions varied significantly among poplar genotypes grown in different potting media. Conclusions Tandem instrumentation offers a powerful tool for profiling volatile molecular markers and elucidating their genetic and environmental underpinnings. This approach enhances our ability to predict BVOC emissions in response to genotype by environmental interactions and contributes to a deeper understanding of vegetation responses to environmental changes.

Biogenic volatile organic compounds↗

CROCUS Air Quality Dataset from the University of Illinois Chicago (UIC), July 2024

This dataset was collected by the measurement system in the Atmosphere, Climate, and Ecosystems (ACE) Lab at the University of Illinois Chicago (UIC) from July 12 to July 31, 2024, as part of the Community Research on Climate and Urban Science (CROCUS) Urban Integrated Field Laboratory (UIFL) project, led by Argonne National Laboratory.To enhance understanding of urban air quality dynamics in Chicago, and as part of the CROCUS 2024 Urban Canyon Intensive Observation Period (IOP), several instruments were set up to provide continuous measurements of air quality parameters in Chicago during July 2024. These measurements cover both aerosols and gas-phase species. It focuses on particle size distribution (2.5–478 nm) measured by two Scanning Mobility Particle Sizers (SMPS) at a 4-min resolution, total particle number concentrations at a 1-s resolution, and chemical composition from a High-Resolution Time-of-Flight Aerosol Mass Spectrometer (AMS) at a 1-min resolution. Key gas-phase species, including NO, NO₂, SO₂, and O₃, are measured at a 1-min resolution, along with high-resolution NO and dimethyl sulfide (DMS) data from a Chemical Ionization Mass Spectrometer (CIMS). Volatile organic compound (VOC) data for toluene, isoprene, and benzene are provided by a GC-PID with a time resolution of 25 minutes.The data are formatted as NetCDF (.nc) files, making them easily accessible using common software such as MATLAB, R, and Python. Each parameter is stored in an individual dataset, which includes detailed instrument information in the header, as well as the corresponding sample start time and concentration/distribution data for each sample.

54 ENVIRONMENTAL SCIENCES↗

Cloud Droplet Measurement System for the ARM Tethered Balloon System (TBS) Field Campaign Report

The Mesa Photonics' cloud droplet measurement system (CDMS) performs in situ measurement of droplet size distribution and droplet number density in clouds. These characteristics are important cloud microphysical properties that are critical input parameters for atmospheric models and are also useful for proper calibration and validation of performance of other atmospheric measurement instrumentation. This small campaign was the first project (out of two) that involved integration of the CDMS into the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s tethered balloon system (TBS) and its initial testing at the ARM Southern Great Plains (SGP) atmospheric observatory. The follow-up campaign (AFC07016) involved testing of the CDMS under relevant conditions at the third ARM Mobile Facility (AMF3) at Oliktok Point, Alaska and making in situ measurements in clouds. The goal of this small field campaign was to deploy the CDMS on the ARM TBS, demonstrate its integrity and compatibility with the TBS, and test the wireless telecommunication system in preparation for subsequent in-cloud measurements at ARM’s North Slope of Alaska (NSA) observatory at Utqiagvik (formerly Barrow). The specific technical objectives included: (1) Integration of the Mesa Photonics' CDMS into the ARM TBS, (2) testing of the wireless telecommunication system of the CDMS, (3) evaluating the data acquisition software and image processing algorithms especially under high-background-illumination conditions, and (4) testing the ruggedness of the instrument's optical alignment and other performance characteristics. All objectives have been successfully met. The mounting hardware was designed and built mostly at Sandia National Laboratories (SNL), which allowed reliable mounting of the CDMS on the TBS and co-locating the CDMS with other instruments. The field tests were performed by the principal investigator (PI) in collaboration with the TBS operational crew led by D. Dexheimer. The field testing demonstrated good compatibility of the CDMS with the TBS. During the TBS flights, the crew did not experience any operational issues with the CDMS. The instrument demonstrated reliable operational characteristics, including sufficient battery life and good thermal management. The wireless telecommunication system has been successfully tested at TBS flight altitudes of up to 1000 m. During all flights, the CDMS raw data were wirelessly transmitted to the ground station and processed in real time. The ruggedness of the instrument's optical alignment was evaluated by performing calibration of the CDMS (using Mesa Photonics' fixed-size monodisperse droplet generator) before and after the campaign. The calibration was stable within the instrument's measurement precision. In summary, the campaign demonstrated good compatibility of the Mesa Photonics' CDMS with the ARM TBS. The flight tests confirmed the mechanical integrity of the CDMS and stability of its optical layout, as well as reliability of the wireless telecommunication system. Successful completion of this campaign provided a solid basis for the next campaign (AFC07016, November 2020), that involved testing of the CDMS during in-cloud TBS flights at AMF3 at Oliktok Point.

54 ENVIRONMENTAL SCIENCES↗

SimELIT: A Novel GUI-Based Comprehensive Ion Trajectory Simulation Software for Mass Spectrometry

Ion trajectory simulation in mass spectrometry systems from injection to detection is technically challenging but very important for better understanding the ion dynamics in instrument development. Here, in this work, we present SimELIT (Simulator of Eulerian and Lagrangian Ion Trajectories), a novel ion trajectory simulation platform. SimELIT is built upon a suite of multiphysics solvers compiled into OpenFOAM (an open-source numerical solver library particularly used for computational mechanics), with a simple web-based graphical user interface (GUI) allowing users to define the details of OpenFOAM cases and run simulations. SimELIT is a modular program and can provide extensions of physics (e.g., gas flows, electrodynamic fields) and thus enable ion trajectory simulations from the ion source to detector. The current version (SimELIT) provides two numerical solvers for ion trajectory simulations–(1) a Lagrangian particle tracker in vacuum and (2) a Eulerian ion density solver in background gas in the presence of electric fields. Here, we describe the architecture of SimELIT, including its use of Docker and the React Framework, and demonstrate the computation of ion trajectories of multiple m/z values in a static/linear voltage drop in vacuum (across a 1 m long flight tube). Further, the drift motion of ions under 1 Torr pressure conditions in a static background (N 2 ) gas through a 20 V/cm static electric field is shown. The results produced from SimELIT were compared with SIMION and theoretical estimates. In addition, we report the computation of ion trajectories in electrodynamic fields within a planar FAIMS device operating at atmospheric pressure.

97 MATHEMATICS AND COMPUTING↗

Electron Density Measurements Using USPR (Final Scientific/Technical Report)

UC Davis has fabricated an ultrashort pulse reflectometer (USPR) diagnostic instrument for electron density profile measurements on compact, short duration, magnetically-confined fusion-energy concept devices such as spheromaks and FRCs. The USPR system transmits extremely short duration (~few nsec) chirped waveforms that together span 29 to 75 GHz. These chirped waveforms illuminate and reflect from the target plasma, with each frequency component reflecting from a different density layer (higher frequencies probe deeper into the plasma before reflecting). The reflected waveforms are split into roughly 42 different frequencies; time-of-flight (TOF) measurements made at each frequency with high resolution (~25 psec measurement resolution which corresponds to ~5 mm). These TOF data may then be inverted via software to generate electron density profiles with high time resolution (~10 μsec). At the heart of the system is a field programmable gate array (FPGA) based controller which collects and processes all of the USPR data in addition to generating all of the control signals required for maximum flexibility. The FPGA controller has the software flexibility to be easily reconfigured for different plasma devices, and the entire system sufficiently compact to be easily and quickly transported between devices. A high speed impulse generator was transformed into a set of three ultrashort pulse transmitter chirps using a combination of dispersive waveguide, frequency doublers and high-pass filters. A mm-wave controller was fabricated to sequentially switch between the three chirps, directing the chirps one-by-one to three different mm-wave assemblies spanning 29-75 GHz. Each mm-wave assembly consists of a high power active multiplier chain which converts the transmitter chirp to higher frequencies, and a broadband mixer which downconverts the reflected waveform to the 2-18 GHz range of the UPSR receiver. The 16-channel receiver (shared by all 3 mm-wave assemblies) was fabricated employing custom TOF modules capable of operating at a high 1 MHz sampling rate. Laboratory testing of the full system revealed the presence of unwanted harmonics from the multiplication process, with interference observed in the downconverted reflections at selected frequency channels that could not be completely filtered out. Additional interference effects arising from internal reflections within the mm-wave assemblies were minimized using a high-speed switch which served to “gate out” much of these reflections. The USPR diagnostic was transported and installed onto the HIT-SIU plasma device, becoming operational on 11/08/2022. Although designed to span 3 distinct mm-wave bands, the HIT-SIU plasmas at this time were sufficiently low density such that only the lowest of the three bands was likely to have strong plasma reflections. The system was then set to operate on only the lowest band (assembly #1), with data collected every 1 μsec rather than 3 μsec which would have been the case when cycling through all three bands. Connected to HIT-SIU, time-varying plasma reflections were observed on 9 of 16 possible frequency channels. Close examination of the data collected revealed issues previously unobserved in laboratory testing, associated with (a) reflections from the small aperture horns required for operation within the HIT-SIU device, and (b) a dependence of the recorded TOF with the threshold voltage of a given channel. Plans were made to address each of these issues before undertaking any future campaigns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-latency NuMI Trigger for the CHIPS-5 Neutrino Detector

The CHIPS R&D project aims to develop affordable water Cherenkov detectors for large-scale underwater installations. In 2019, a 5kt prototype detector CHIPS-5 was deployed in northern Minnesota to study neutrinos generated by the nearby NuMI beam. This contribution presents a dedicated low-latency time distribution system for CHIPS-5 that delivers timing signals from the Fermilab accelerator to the detector with sub-nanosecond precision. Exploiting existing NOvA infrastructure, the time distribution system achieves this only with open-source software and conventional network elements. In a time-of-flight study, the presented system has reliably offered a time budget of $610 \pm 330\text{ ms}$ for on-site triggering. This permits advanced analysis in real-time as well as a novel hardware-assisted active triggering mode, which reduces DAQ computing load and network bandwidth outside triggered time windows.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Method for High Resolution Surface Change Detection: Data Collection and Validation of Measurements from UAS at the Nevada National Security Site, Nevada, USA

The use of uncrewed aerial systems (UAS) increases the opportunities for detecting surface changes in remote areas and in challenging terrain. Detecting surface topographic changes offers an important constraint for understanding earthquake damage, groundwater depletion, effects of mining, and other events. For these purposes, changes on the order of 5–10 cm are readily detected, but sometimes it is necessary to detect smaller changes. An example is the surface changes that result from underground explosions, which can be as small as 3 cm. Previous studies that described change detection methodologies were generally not aimed at detecting sub-5-cm changes. Additionally, studies focused on high-fidelity accuracy were either computationally modeled or did not fully provide the necessary examples to highlight the usability of these workflows. Detecting changes at this threshold may be critical in certain applications, such as global security research and monitoring for high-consequence natural hazards, including landslides. Here we provide a detailed description of the methodology we used to detect 2–3 cm changes in an important applied research setting—surface changes related to underground explosions. This methodology improves the accuracy of change detection data collection and analysis through the optimization of pre-field planning, surveying, flight operations, and post-processing the collected data, all of which are critical to obtaining the highest output data resolution possible. We applied this methodology to a field study location, collecting 1.4 Tb of images over the course of 30 flights, and location data for 239 ground control points (GCPs). We independently verified changes with orthoimagery, and found that structure-from-motion, software-reported root mean square errors (RMSEs) for both control and check points underestimated the actual error. We found that 3 cm changes are detectable with this methodology, thereby improving our knowledge of a rock’s response to underground explosions.

47 OTHER INSTRUMENTATION↗

Multi-sensor fusion for robust autonomous flight in indoor and outdoor environments with a rotorcraft micro-aerial vehicle (MAV)

The subject matter described herein includes a modular and extensible approach to integrate noisy measurements from multiple heterogeneous sensors that yield either absolute or relative observations at different and varying time intervals, and to provide smooth and globally consistent estimates of position in real time for autonomous flight. We describe the development of the algorithms and software architecture for a new 1.9 kg MAV platform equipped with an IMU, laser scanner, stereo cameras, pressure altimeter, magnetometer, and a GPS receiver, in which the state estimation and control are performed onboard on an Intel NUC 3rd generation i3 processor. We illustrate the robustness of our framework in large-scale, indoor-outdoor autonomous aerial navigation experiments involving traversals of over 440 meters at average speeds of 1.5 m/s with winds around 10 mph while entering and exiting buildings.

42 ENGINEERING↗

The Psyche Gamma-Ray and Neutron Spectrometer

A Gamma-Ray and Neutron Spectrometer (GRNS) instrument has been developed as part of the science payload for NASA’s Discovery Program Psyche mission to the M-class asteroid (16) Psyche. The GRNS instrument is designed to measure the elemental composition of Psyche with the goal to understand the origin of this mysterious, potentially metal-rich planetary body. The GRNS will measure the near-surface abundances for the elements Ni, Fe, Si, K, S, Al, and Ca, as well as the spatial distribution of Psyche’s metal-to-silicate fraction (or metal fraction). These measurements address three of the five Psyche mission science objectives: determine if Psyche is a core; determine whether small metal bodies incorporate light elements into the metal phase; and determine whether Psyche was formed under reducing conditions. The Gamma-Ray Spectrometer (GRS) uses a cryocooled, high-purity Ge (HPGe) sensor to detect cosmic-ray generated gamma rays in the 60 to 9000-keV energy range. The HPGe sensor is surrounded by a borated plastic anticoincidence shield that provides three functions: active background rejection from charged particle interactions in the HPGe sensor; fast neutron measurements; and direct measurements of the incident galactic cosmic ray flux. The Neutron Spectrometer (NS) uses three 3 He gas proportional sensors, each with different material wraps to measure thermal (<0.4 eV), low-energy epithermal (0.4 eV to 1 keV), and high-energy epithermal (up to 100 keV) neutrons. This paper provides an overview of the Psyche GRNS, including: its science and measurement objectives; the design of the instrument hardware, software, and operation; pre-launch performance measurements and its initial performance in space; and an overview of its data products and expected operation for different Psyche mission phases.

Engineering - Instrumentation related to nuclear s↗

Report on ISR-1 High-Altitude Balloon Flight

To test small technologies at lower cost for space science applications, LANL has developed a small high altitude balloon payload that could, in the future, be regularly and inexpensively launched from LANL. A neutron detector, NEMO, was integrated to evaluate its performance in a space-like mixed-radiation environment and collect neutron data in the atmosphere. In collaboration with EES-14, a high-altitude balloon payload was launched from LANL Technical Area 51 on February 27, 2023 and April 17, 2023. For real-time geolocation, a SAM-M8Q M8 GNSS module was used to get position and time, and an Iridium RockBLOCK 9603 was used to communicate with the ground using the Iridium satellite fleet. These modules were all controlled using an Iteaduino Mega microcontroller board. Finally, a High Altitude Science Eagle Flight Computer with a temperature pressure sensor ran independently, writing data to an SD card. All of these modules were powered by a 5 mAh lithium polymer battery. The battery was attached to the bottom of the payload while the remaining electronics were embedded in the underside of the top of the payload. These modules were wired as seen in Figure 1-2. The Iteaduino Mega microcontroller board was programmed to use the RockBLOCK to send a message once every 10 minutes containing neutron and GPS data read off the NEMO and SAM M8Q, respectively. Once the message send attempt finished, the RockBLOCK would be slept for the rest of the 10 minute interval. The Eagle Flight Computer ran continuously throughout the flight, taking data every 6 seconds. The RockBLOCK message data was set up to be delivered from the Iridium satellite fleet to a website, where it was stored and parsed to create live maps and plots for analysis and balloon retrieval. The RockBLOCK message data was additionally configured to be sent to an email as a fail-safe. The payload was ground-tested successfully for over 50 hours, with multiple revisions occurring to best prepare for conditions at altitude and improve the software and firmware to fix any issues that cropped up with the data pipeline. Additional to the balloon payload, the flight had an attached iMet-4 radiosonde and Garmin T5 GPS Dog Collar. The radiosonde provided GPS and meteorological data. The T5 dog collar is used along with a Garmin Astro 430 to track the balloon at a range of up to 9 miles for retrieval. The balloon itself was initially a 1600 g meteorological balloon with an attached High Altitude Science parachute, both of which can be seen in Figure 1-3. After the first flight, the EES team swapped to a Rocketman parachute.

42 ENGINEERING↗

POWTEX visits POWGEN

The high-intensity time-of-flight (TOF) neutron diffractometer POWTEX for powder and texture analysis is currently being built prior to operation in the eastern guide hall of the research reactor FRM II at Garching close to Munich, Germany. Because of the world-wide 3 He crisis in 2009, the authors promptly initiated the development of 3 He-free detector alternatives that are tailor-made for the requirements of large-area diffractometers. Herein is reported the 2017 enterprise to operate one mounting unit of the final POWTEX detector on the neutron powder diffractometer POWGEN at the Spallation Neutron Source located at Oak Ridge National Laboratory, USA. As a result, presented here are the first angular- and wavelength-dependent data from the POWTEX detector, unfortunately damaged by a 50 g shock but still operating, as well as the efforts made both to characterize the transport damage and to successfully recalibrate the voxel positions in order to yield nonetheless reliable measurements. Also described is the current data reduction process using the PowderReduceP2D algorithm implemented in Mantid [Arnold et al. (2014). Nucl. Instrum. Methods Phys. Res. A , 764 , 156–166]. The final part of the data treatment chain, namely a novel multi-dimensional refinement using a modified version of the GSAS-II software suite [Toby & Von Dreele (2013). J. Appl. Cryst. 46 , 544–549], is compared with a standard data treatment of the same event data conventionally reduced as TOF diffraction patterns and refined with the unmodified version of GSAS-II . This involves both determining the instrumental resolution parameters using POWGEN's powdered diamond standard sample and the refinement of a friendly-user sample, BaZn(NCN) 2 . Although each structural parameter on its own looks similar upon comparing the conventional (1D) and multi-dimensional (2D) treatments, also in terms of precision, a closer view shows small but possibly significant differences. For example, the somewhat suspicious proximity of the a and b lattice parameters of BaZn(NCN) 2 crystallizing in Pbca as resulting from the 1D refinement (0.008 Å) is five times less pronounced in the 2D refinement (0.038 Å). Similar features are found when comparing bond lengths and bond angles, e.g. the two N—C—N units are less differently bent in the 1D results (173 and 175°) than in the 2D results (167 and 173°). The results are of importance not only for POWTEX but also for other neutron TOF diffractometers with large-area detectors, like POWGEN at the SNS or the future DREAM beamline at the European Spallation Source.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inferring UAV Position Relative to Smartphone Sensor Based on Acoustic Characteristics

As commercial and non-commercial unmanned aerial vehicles (UAVs) improve technologically and increase in accessibility, their potential for use in actions antithetical to nuclear non-proliferation efforts increases as well. The ability to identify and locate UAVs using ubiquitous, inexpensive hardware and software would be advantageous as both a deterrent and an initial warning system. Our team looks to utilize smartphones as acoustic sensors to record and characterize UAV movement based on the sound produced while in flight. Multi-rotor UAVs produce identifiable acoustic spectral characteristics with frequencies and harmonics corresponding to motor revolutions per minute and the propeller characteristics. As the source moves closer to the receiver these spectral patterns remain relatively stable (at slow speeds), while the energy observed from the waves increases. The goal of this work is to utilize a small network of smartphone sensors with known, fixed positions to infer the relative position of an in-flight UAV with respect to the position of the smartphones through the variation in acoustic energy.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

An Open Source Perovskite Solar Cell Curve Tracer

When developing systems for perovskite solar cells (PSCs), it is important to have a testing platform that closely resembles your deployed systems. While developing a 1 U CubeSat, the Big Red Sat-1 at the University of Nebraska-Lincoln, we found a lack of passive curve tracing instrumentation, which we needed for our mission. To that end, we developed a benchtop passive curve tracer that leverages the Ossila Solar Simulator as an AM1.5 light source. This device utilizes a ladder of switched resistors and a precision voltage and current measurement to achieve the curve tracing. It also integrates a common-anode multiplexer to switch through multipixel PSCs. Finally, the solar cell holder is separate from the main measurement system, so various substrates sizes and pixel counts can be supported. This system is tested using various PSCs. It has been open sourced to enable reuse in future systems that may benefit from the lower power consumption and flight heritage.

14 SOLAR ENERGY↗

macroMS: Image-Guided Analysis of Random Objects by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

Mass spectrometry imaging is well-suited to characterizing sample surfaces for their chemical content in a spatially resolved manner. However, when the surface contains small objects with significant empty spaces between them, more efficient approaches to sample acquisition are possible. Image-guided mass spectrometry (MS) enables high-throughput analysis of a diverse range of sample types, such as microbial colonies, liquid microdroplets, and others, by recognizing and analyzing selected location targets in an image. Here, we describe an imaging protocol and macroMS, an online software suite that can be used to enhance MS measurements of macroscopic samples that are imaged by a camera or a flatbed scanner. Furthermore, the web-based tool enables users to find and filter targets from the optical images, correct optical distortion issues for improved spatial location of selected targets, input the custom geometry files into an MS device to acquire spectra at the selected locations, and finally, perform limited data analysis and use visualization tools to aid locating samples containing compounds of interest. Using the macroMS suite, an enzyme mutant library of Saccharomyces cerevisiae and nL droplet arrays of Escherichia coli and Pseudomonas fluorescens have been assayed at a rate of ~2 s/sample.

47 OTHER INSTRUMENTATION↗