GMI Instrument Spin Balance Method, Optimization, Calibration, and Test

The Global Microwave Imager (GMI) instrument must spin at a constant rate of 32 rpm continuously for the 3 year mission life. Therefore, GMI must be very precisely balanced about the spin axis and CG to maintain stable scan pointing and to minimize disturbances imparted to the spacecraft and attitude control on-orbit. The GMI instrument is part of the core Global Precipitation Measurement (GPM) spacecraft and is used to make calibrated radiometric measurements at multiple microwave frequencies and polarizations. The GPM mission is an international effort managed by the National Aeronautics and Space Administration (NASA) to improve climate, weather, and hydro-meteorological predictions through more accurate and frequent precipitation measurements. Ball Aerospace and Technologies Corporation (BATC) was selected by NASA Goddard Space Flight Center to design, build, and test the GMI instrument. The GMI design has to meet a challenging set of spin balance requirements and had to be brought into simultaneous static and dynamic spin balance after the entire instrument was already assembled and before environmental tests began. The focus of this contribution is on the analytical and test activities undertaken to meet the challenging spin balance requirements of the GMI instrument. The novel process of measuring the residual static and dynamic imbalances with a very high level of accuracy and precision is presented together with the prediction of the optimal balance masses and their locations.

Ayari, Laoucet

GMI Instrument Spin Balance Method, Optimization, Calibration and Test

The Global Microwave Imager (GMI) instrument must spin at a constant rate of 32 rpm continuously for the 3-year mission life. Therefore, GMI must be very precisely balanced about the spin axis and center of gravity (CG) to maintain stable scan pointing and to minimize disturbances imparted to the spacecraft and attitude control on-orbit. The GMI instrument is part of the core Global Precipitation Measurement (GPM) spacecraft and is used to make calibrated radiometric measurements at multiple microwave frequencies and polarizations. The GPM mission is an international effort managed by the National Aeronautics and Space Administration (NASA) to improve climate, weather, and hydro-meteorological predictions through more accurate and frequent precipitation measurements. Ball Aerospace and Technologies Corporation (BATC) was selected by NASA Goddard Space Flight Center to design, build, and test the GMI instrument. The GMI design has to meet a challenging set of spin balance requirements and had to be brought into simultaneous static and dynamic spin balance after the entire instrument was already assembled and before environmental tests began. The focus of this contribution is on the analytical and test activities undertaken to meet the challenging spin balance requirements of the GMI instrument. The novel process of measuring the residual static and dynamic imbalances with a very high level of accuracy and precision is presented together with the prediction of the optimal balance masses and their locations.

Ayari, Laoucet

Optimal Design of Calibration Signals in Space Borne Gravitational Wave Detectors

Future space borne gravitational wave detectors will require a precise definition of calibration signals to ensure the achievement of their design sensitivity. The careful design of the test signals plays a key role in the correct understanding and characterization of these instruments. In that sense, methods achieving optimal experiment designs must be considered as complementary to the parameter estimation methods being used to determine the parameters describing the system. The relevance of experiment design is particularly significant for the LISA Pathfinder mission, which will spend most of its operation time performing experiments to characterize key technologies for future space borne gravitational wave observatories. Here we propose a framework to derive the optimal signals in terms of minimum parameter uncertainty to be injected to these instruments during its calibration phase. We compare our results with an alternative numerical algorithm which achieves an optimal input signal by iteratively improving an initial guess. We show agreement of both approaches when applied to the LISA Pathfinder case.

LISA Path_nder mission

Studying the MLT by a Combined Analysis of SABER/TIMED and Lidar Measurements

The SABER instrument on board the TIMED Satellite is a limb scanning infrared radiometer designed to measure temperature and minor constituent vertical profiles and energetics parameters in the mesosphere and lower thermosphere (MLT). The measurements have been performed continuously since January 25, 2002 to provide excellent coverage for both hemispheres. The Leibniz-Institute of Atmospheric Physics (LAP) at Kuehlungsborn, Germany (54N, 12E) operates two lidar instruments, using three different temperature measurement methods, optimized for three altitude ranges. The total altitude range of the lidar installation lies from 1 to 105 km. Another instrument used for intercomparison is the ALOMAR RMR lidar, located at Andoya, Norway (69N, 16E). We have searched the SABER and lidar datasets for coincidental common volume measurements within plus or minus 1 degree in latitude, plus or minus 2 degrees in longitude and approx. 1 hour in time for the sake of (a) comparison of measured temperatures; (b) validation of the models used in SABER data analysis; and (c) extracting new information about MLT parameters. In this work we applied the non-LTE ALI-ARMS code designed to calculate the nonequilibrium radiance in different viewing geometries to the analysis of measurements which satisfied these search criteria. The results of this analysis (a) support the application of higher value of CO2-O quenching rate (6e-12 cubic centimeters per second) by the non-LTE temperature retrievals from the SABER 15 micrometer limb radiance data, and (b) demonstrate the importance of accounting for the vibrational-vibrational energy exchange among the CO2 isotopes for accurate temperature retrievals. Using temperature profiles obtained in lidar measurements as inputs for the retrieval algorithm we also retrieved the nighttime CO2 densities from the SABER 15 micrometer limb radiances and compared them with the model and climatology CO2 data used in the SABER nighttime temperature retrievals.

Feofilov, A. G.

Structured-groove phase gratings for control and optimization of the spectral efficiency

Phase gratings are used as dispersers in a variety of imaging spectroscopic instruments. However, conventional phase gratings provide limited spectral range and flexibility to fully optimize instrument performance for challenging applications. Presented here is a new design method that tailors and optimizes the spectral efficiency by introducing an arbitrary structure into the grating groove profile.

diffraction gratings

AVHRR-Based Polar Pathfinder Products: Evaluation, Enhancement and Transition to MODIS

Study of the environment has historically been done with observations and measurements in relatively few local areas. While some of these have been done over long time spans, most have not. The NOAA/NASA Pathfinder project was initiated to complement these data sets with satellite data that can provide information over larger spatial areas and longer time spans. The AVHRR Polar Pathfinder (APR) program was part of this project. The APR was to supply data from the NOAA AVHRR instruments that was consistently generated in a format usable to a wide range of scientific investigators. A grant was obtained from the NASA Research Announcement 97-MTPE-03 to evaluate the APP products, to provide any enhancements, and to compare with products from the new MODIS instrument. There was about a two year overlap between the projects, and this validation effort had several impacts on the APP products. The APP products are derived from the instruments aboard 4 NOAA satellites, NOAA-7, 9, 11, and 14. Initial validation efforts compared the thermal calibrations of these instruments, and differences are found. Calibration has undergone many revisions and techniques have changed since the satellites were launched. The first calibration methods were optimized for global ocean temperatures, as this was one of the primary and important uses of the AVHRR instruments. As the APP program started, newer methods that provided more accurate temperature retrievals over a wider range of temperatures were being developed. The calibration of a wider range of temperatures were necessary because of the extremely low values in the polar regions. These methods were also designed so that calibrated data was also consistent between all the NOAA satellites. These newer calibration methods were then adopted primarily because of the initial finding of this validation effort.

Fowler, Charles

Optimized bandpasses for the Habitable Worlds Observatory's exoEarth survey

A primary scientific goal of the future Habitable Worlds Observatory will be the direct detection and characterization of Earth-like planets. Estimates of the exoplanet yields for this concept will help guide mission design through detailed trade studies. It is therefore critical that yield estimation codes optimally adapt observations to the mission’s performance parameters to ensure accurate trade studies. To aid in this, we implement wavelength optimization in yield calculations for the first time, allowing the yield code to determine the ideal detection and characterization bandpasses. We use this capability to confirm the observational wavelength assumptions made for the large UV/Optical/IR surveyor, design B (LUVOIR-B) study, namely that the optimum detection wavelength is 500 nm for the majority of targets and the optimum wavelength to detect water is near 1000 nm, given LUVOIR-B’s assumed instrument performance parameters. We show that including the wavelength-dependent albedo of an Earth twin as a prior provides no significant benefit to the yields of exoEarth candidates and caution against tuning observations to modern Earth twins. We also show that coronagraphs whose inner working angles are similar to step functions may benefit from wavelength optimization and demonstrate how wavelength-dependent instrument performance can impact the optimum wavelengths for detection and characterization. The optimization methods we implement automate wavelength selection and remove uncertainties regarding these choices, helping to adapt the observations to the instrument’s performance parameters.

telescopes

Optimal design and evaluation criteria for acoustic emission pulse signature analysis

Successful pulse recording and evaluation is strongly dependent on the instrumentation system selected and the method of analyzing the pulse signature. The paper studies system design, signal analysis techniques, and interdependences with a view toward defining optimal approaches to pulse signal analysis. For this purpose, the instrumentation system is modeled, and analytical pulses, representative of the types of acoustic emissions to be distinguished are passed through the system. Particular attention is given to comparing frequency spectrum analysis and deconvolution referred to as time domain reconstruction of the pulse or pulse train. The possibility of optimal transducer-filter system parameters is investigated. Deconvolution of a pulse is shown to be a superior approach for transient pulse analysis. Reshaping of a transducer output back to the original input pulse is possible and gives an accurate representation of the generating pulse in the time domain. Any definable transducer and filter system can be used for measurement of pulses by means of the deconvolution method. Selection of design variables for general usage is discussed.

Houghton, J. R.

Numerically Optimized Coronagraph Designs for the Habitable Exoplanet Imaging Mission (HabEx) Concept

The primary science goal of the Habitable Exoplanet Imaging Mission (HabEx), one of four candidate flagship missions under investigation, is to image and spectrally characterize Earth-like exoplanets. It is well known that pupil obscurations degrade coronagraphic performance and complicate coronagraph design, so HabEx is planned to have an off-axis, unobscured primary mirror. We utilize the circular symmetry of the aperture to investigate 1D-radial coronagraph optimization methods that are prohibitively time-consuming or intractable in 2D, such as diffractive pupil remapping and concurrent, multi-plane optimization. We also directly constrain sensitivities to dynamic, low-order Zernike aberrations, which are separable in polar coordinates and can thus be propagated as 1D-radial integrals. The mask technologies in our designs claim heritage from the extensive modeling and testbed experiments performed by the Wide-Field Infrared Survey Telescope (WFIRST) Coronagraph Instrument (CGI) project. In this paper, we detail our optimization methods and outline future work to complete our design survey.

Balasubramaian, Kunjithapatham

Optimization studies for the development of adaptive wall wind tunnel

The development of adaptive wall wind tunnels makes it possible to establish interference-free boundaries in the region of the model. It is, therefore, feasible to simulate free air conditions. However, the amount of total testing time involved in establishing the required conditions and the complexity of the needed instrumentation prevent currently the use of such methods for routine production testing. Optimization studies have been proposed with the objective to find approaches which will make a more extended application of adaptive wall techniques possible. A new 25cm x 11cm adaptive wall test section was designed and installed to carry out some of these studies. Investigations envisaged are related to the development of a one step convergence method to reduce total testing time, and to measurement procedures which will permit a simplification of the instrumentation. Attention is given to the proposed concept, the test section, instrumentation, and the influence coefficients.

Bodapati, S.

Optimization of payload placement on arbitrary spacecraft

A systematic method for determining the optical placement of instrumentation on an arbitrary spacecraft is described. The method maximizes the resource utilization by minimizing the spacecraft's need for propulsive attitude control. The mathematical program developed with considerations toward reducing the size of the optimization effort is presented.

Ferebee, Melvin J., Jr.

Shaping Diffraction-Grating Grooves to Optimize Efficiency

A method of shaping diffraction-grating grooves to optimize the spectral efficiency, spectral range, and image quality of a spectral imaging instrument is under development. The method is based on the use of an advanced design algorithm to determine the possibly complex shape of grooves needed to obtain a desired efficiency-versus-wavelength response (see figure). Then electron- beam fabrication techniques are used to realize the required groove shape. The method could be used, for example, to make the spectral efficiency of the grating in a given wavelength range proportional to the inverse of the spectral efficiency of a photodetector array so that the overall spectral efficiency of the combination of the grating and the photodetector array would be flat. The method has thus far been applied to one-dimensional gratings only, but in principle, it is also applicable to two-dimensional gratings. The algorithm involves calculations in the spatial-frequency domain. The spatial-frequency spectrum of a grating is represented as a diffraction-order spectral-peak-width function multiplied by an efficiency function for a single grating groove. This representation affords computational efficiency and accuracy by making it possible to consider only the response from one grating groove (one period of the grating), instead of from the whole grating area, in determining the response from the entire grating. This combination of efficiency and accuracy is crucial for future extensions of the algorithm to two-dimensional designs and to designs in which polarization must also be taken into account. The algorithm begins with the definition of target values of relative efficiency that represent the desired spectral response of the grating in certain spectral frequencies calculated from the diffraction order and wavelength. The grating period is divided into a number of cells - typically, 100. The phase contribution from each cell is determined from the phase of the incident electromagnetic wave and the height of the grating surface in the cell. The total contribution from all cells to each target value is then calculated. Then a method known to specialists as the optimum-rotation-angle method is used to adjust the height of each cell so that the total response from all cells is optimized. The computation is iterative and continues until the desired response is obtained. In the event that the desired response is unphysical, the algorithm nevertheless strives to generate a grating-grove profile for which the response approximates the desired one as closely as possible.

Backlund, John

Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better detection via good peak separation with a longer run time is a better asset than moderate peak separation with a shorter run time. Even given that RESOLVE is highly interested in water and that mission timeline is of significant importance given the short seven-to-ten-day mission timeline, worse detection with an 8m column may lead to overlooking other substances existing on the moon that could advance planetary science. Thus, I recommend the 20m column. However, if mission timeline and water separation are deemed the highest priority, the 8m column should be selected due to its ability to separate water within a shorter run time than the 20m column.

Column

Polarization Phase-Compensating Coats for Metallic Mirrors

A method of compensating for or minimizing phase differences between orthogonal polarizations of light reflected from metallic mirrors at oblique incidence, as, for example, from weakly curved mirrors, is undergoing development. The method is intended to satisfy a need to maintain precise polarization phase relationships or minimum polarization differences needed for proper operation of telescopes and other scientific instruments that include single or multiple mirrors. The basic idea of the method is to optimally coat mirrors with thin engineered layers of materials that introduce phase differences that, as nearly precisely as possible, are opposite of the undesired phase differences arising in reflection with non-optimum coatings. Depending on the specific optical system, the method could involve any or all of the following elements: a) Optimization of a single coat on all the mirrors in the system. b) Optimization of a unique coat for each mirror such that the polarization phase effects of the coat on one mirror compensate, to an acceptably high degree over an acceptably wide wavelength range, for those of the coat on another mirror. c) Tapering the coat on each mirror. Optimization could involve the choice of a single dielectric coating material and its thickness, or design of a more complex coat consisting of multiple layers of different dielectric materials and possibly some metallic materials. Such designs and coatings are particularly significant and needed for obtaining very high quality of wavefront required in high-contrast imaging instruments such as the NASA Terrestrial Planet Finder Coronagraph.

Balasubramanian, Kunjithapatham

Online submicron particle sizing by dynamic light scattering using autodilution

Efficient production of a wide range of commercial products based on submicron colloidal dispersions would benefit from instrumentation for online particle sizing, permitting real time monitoring and control of the particle size distribution. Recent advances in the technology of dynamic light scattering (DLS), especially improvements in algorithms for inversion of the intensity autocorrelation function, have made it ideally suited to the measurement of simple particle size distributions in the difficult submicron region. Crucial to the success of an online DSL based instrument is a simple mechanism for automatically sampling and diluting the starting concentrated sample suspension, yielding a final concentration which is optimal for the light scattering measurement. A proprietary method and apparatus was developed for performing this function, designed to be used with a DLS based particle sizing instrument. A PC/AT computer is used as a smart controller for the valves in the sampler diluter, as well as an input-output communicator, video display and data storage device. Quantitative results are presented for a latex suspension and an oil-in-water emulsion.

Nicoli, David F.

2006 Icing Cloud Calibration of the NASA Glenn Icing Research Tunnel

In order to improve icing cloud uniformity, changes were made to the tunnel at the NASA Glenn Research Center in the vicinity of the spray bars. These changes necessitated a complete recalibration of the icing clouds. This report describes the methods used in the recalibration, including the procedure used to optimize the uniformity of the icing cloud and the use of a standard icing blade technique for measurement of liquid water content. The instruments and methods used to perform the droplet size calibration are also described. The liquid water content/droplet size operating envelopes of the icing tunnel are shown for a range of airspeeds and compared to the FAA icing certification criteria.

Ide, Robert F.

Dual Electron Spectrometer for Magnetospheric Multiscale Mission: Results of the Comprehensive Tests of the Engineering Test Unit

The Magnetospheric Multiscale mission (MMS) is designed to study fundamental phenomena in space plasma physics such as a magnetic reconnection. The mission consists of four spacecraft, equipped with identical scientific payloads, allowing for the first measurements of fast dynamics in the critical electron diffusion region where magnetic reconnection occurs and charged particles are demagnetized. The MMS orbit is optimized to ensure the spacecraft spend extended periods of time in locations where reconnection is known to occur: at the dayside magnetopause and in the magnetotail. In order to resolve fine structures of the three dimensional electron distributions in the diffusion region (reconnection site), the Fast Plasma Investigation's (FPI) Dual Electron Spectrometer (DES) is designed to measure three dimensional electron velocity distributions with an extremely high time resolution of 30 ms. In order to achieve this unprecedented sampling rate, four dual spectrometers, each sampling 180 x 45 degree sections of the sky, are installed on each spacecraft. We present results of the comprehensive tests performed on the DES Engineering & Test Unit (ETU). This includes main parameters of the spectrometer such as energy resolution, angular acceptance, and geometric factor along with their variations over the 16 pixels spanning the 180-degree tophat Electro Static Analyzer (ESA) field of view and over the energy of the test beam. A newly developed method for precisely defining the operational space of the instrument is presented as well. This allows optimization of the trade-off between pixel to pixel crosstalk and uniformity of the main spectrometer parameters.

Avanov, Levon A.

Specification of inputs and instrumentation for flutter testing of multivariable systems

The application of system identification methods in flutter testing of aeroelastic structure is discussed. The accuracy with which flutter parameters are estimated depends upon the test plan and on the algorithms used to reduce the data. The techniques for selecting the kinds and optimal positions of inputs and instrumentation, under typical test constraints, are presented. Identification results for both the input/output transfer function and the value of physical parameters are given. Numerical results on the optimal input spectrum and the accelerometer location for estimating flutter parameters of a two dimensional wing are obtained using these algorithms. Current work on applying system identification methods to high order three dimensional aeroelastic structures is reported.

Gupta, N. K.