How are Heterogeneous Nucleation Rate Observations Influenced by Instrument Resolution?

Experimental measurements of the heterogeneous nucleation rate rely on counting the number of nuclei with time. However, the size of a thermodynamically stable nucleus is often a few nanometers in diameter and is below the resolution of most (in situ) measurement techniques that provide a statistically valid sample. Due to the finite resolution of the instruments and analysis methods, it is challenging to capture the incipient nuclei and the subsequent evolution of nuclei density over time. In this work, we demonstrate the impact of instrument resolution on observed nuclei densities by comparing numerical modeling with experimental results. Further, to achieve this, we implemented heterogeneous nucleation within the pore-scale reactive transport modeling framework using classical nucleation theory (CNT). We compared the modeling results with nucleation rates measured using X-ray nanotomography (XnT) and evaluated how these impact the apparent values of the prefactor and interfacial energy based on CNT and the crystal growth rate. Specifically, we applied a resolution threshold (artificial resolution limit) in the model during nuclei counting to resemble an experimental resolution, ranging from 15 to 500 nm. The findings reveal that the instrument resolution significantly impacts the apparent prefactor and interfacial energy. Both apparent prefactor and interfacial energy decrease with a decrease in the instrument resolution. While deviation in the prefactor due to resolution is anticipated, those in the interfacial energy are unexpected. The approach described here allows one to correct apparent nucleation rates that depend on the instrument’s resolution to derive “intrinsic” CNT parameters for the prefactor and interfacial energy.

47 OTHER INSTRUMENTATION↗

Instrumental resolution as a function of scattering angle and wavelength as exemplified for the POWGEN instrument

The method of angular- and wavelength-dispersive (e.g. two-dimensional) Rietveld refinement is a new and emerging tool for the analysis of neutron diffraction data measured at time-of-flight instruments with large area detectors. Following the approach for one-dimensional refinements (using either scattering angle or time of flight), the first step at each beam time cycle is the calibration of the instrument including the determination of instrumental contributions to the peak shape variation to be expected for diffraction patterns measured by the users. The aim of this work is to provide the users with calibration files and – for the later Rietveld refinement of the measured data – with an instrumental resolution file (IRF). This article will elaborate on the necessary steps to generate such an IRF for the angular- and wavelength-dispersive case, exemplified for the POWGEN instrument. A dataset measured on a standard diamond sample is used to extract the profile function in the two-dimensional case. It is found that the variation of reflection width with 2θ and λ can be expressed by the standard equation used for evaluating the instrumental resolution, which yields a substantially more fundamental approach to the parameterization of the instrumental contribution to the peak shape. Geometrical considerations of the POWGEN instrument and sample effects lead to values for Δθ, Δt and ΔL that yield a very good match to the extracted FWHM values. In a final step the refinement results are compared with the one-dimensional, i.e. diffraction-focused, case.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Desmearing small-angle scattering data by central moment expansions of instrument resolution

This study introduces an enhanced numerical technique tailored specifically for refining 1D small-angle scattering (SAS) intensity profiles affected by smearing. Our primary objective is to address the resolution blurring commonly encountered in SAS data, particularly in systems with clearly defined correlation peaks whose spread aligns with the width of the resolution function at corresponding Q positions. Unlike previous approaches that expanded the SAS intensity using central moment expansion, the new method focuses on expanding the resolution function itself, thus eliminating artificial oscillations observed in smeared spectra due to limitations inherent in our earlier algorithm. This method is straightforward to implement, computationally efficient and consistently performs well in numerical benchmarking. To illustrate its effectiveness, we present a case study of a lamellar phase characterized by distinct peaks in its small-angle neutron scattering intensities.

central moment expansions↗

Response to 'Comment on 'Elastic incoherent neutron scattering operating by varying instrumental energy resolution: Principle, simulations, and experiments of the resolution elastic neutron scattering (RENS)'' [Rev. Sci. Instrum. 83, 107101 (2012)]

Recently [S. Magazu et al., Rev. Sci. Instrum. 82, 105115 (2011)] we have proposed a new method for characterizing, by neutron scattering, the dynamical properties of complex material systems, such as, the ones of interest in the biophysical field. This approach called Resolution Elastic Neutron Scattering, in short RENS, is based on the detection of the elastically scattered neutron intensity as a function of the instrumental energy resolution. By experimental, theoretical, and numerical findings, we have pointed out that an inflection point occurs in the elastic intensity when the system relaxation time approaches the instrumental energy resolution time. This approach, differently from quasi-elastic neutron scattering (QENS), gives the chance to evaluate the system relaxation times without using pre-defined models that can be wrong and/or misleading. Here, we reply to a Comment on the above-mentioned main paper in which Wuttke proposes a different approach to evaluate the above-mentioned inflection point; on this regard, it should be noticed that the existence of the inflection point, which is the main topic of our work, is not questioned and that the approach proposed by Wuttke in the Comment, although valid for a class of dynamical processes, is not applicable when different and distinct processes occur simultaneously at different time scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance improvements of wavelength-shifting-fiber neutron detectors using high-resolution positioning algorithms

On the basis of FluoroBancroft linear-algebraic method [S.B. Andersson, Opt. Exp. 16, 18714 (2008)] three highly-resolved positioning methods were proposed for wavelength-shifting fiber (WLSF) neutron detectors. Using a Gaussian or exponential-decay light-response function (LRF), the non-linear relation of photon-number profiles vs. x-pixels was linearized and neutron positions were determined. The proposed algorithms give an average 0.03-0.08 pixel position error, much smaller than that (0.29 pixel) from a traditional maximum photon algorithm (MPA). The new algorithms result in better detector uniformity, less position misassignment (ghosting), better spatial resolution, and an equivalent or better instrument resolution in powder diffraction than the MPA. Moreover, these characters will facilitate broader applications of WLSF detectors at time-of-flight neutron powder diffraction beamlines, including single-crystal diffraction and texture analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pushing data quality for laboratory pair distribution function experiments

Over the past decade, some studies with laboratory pair distribution function (PDF) data emerged. Yet, limited Q max or instrumental resolution impeded in-depth structural refinements. With more advanced detector technologies, the question arose how to design novel PDF equipment for laboratories that will allow decent PDF refinements over r = 1–70 Å. It is crucial to reflect the essential requirements, namely, monochromatic X-rays, suppression of air scattering, instrumental resolution, and overall measurement times. The result is a novel PDF setup based on a STOE STADI P powder diffractometer in transmission-/Debye-Scherrer geometry with monochromatic Ag Kα 1 radiation, featuring a MYTHEN2 4K detector covering a Q range of 0.3–20.5 Å –1 . PDF data are collected in a moving PDF mode within 6 h. Structural signatures of liquids can be satisfactorily resolved in the PDF as shown for the ionic liquid hmimPF 6 . The high instrumental resolution is mirrored in low q damp values determined from LaB 6 measurements. PDF data from a powder sample of ca. 7 nm TiO 2 nanoparticles were successfully refined over up to 70 Å with goodness-of-fit values R w < 0.22 (respectively R w = 0.18 over 30 Å), thanks to the low background and high instrumental resolution, hereby enlarging the accessible r range by several tens of Angstroms compared to previous laboratory PDF studies.

47 OTHER INSTRUMENTATION↗

Scaling analysis of bio-molecular dynamics derived from elastic incoherent neutron scattering experiments

Numerous neutron scattering studies of bio-molecular dynamics employ a qualitative analysis of elastic scattering data and atomic mean square displacements. We provide a new quantitative approach showing that the intensity at zero energy exchange can be a rich source of information of bio-structural fluctuations on a pico- to nano-second time scale. Elastic intensity scans performed either as a function of the temperature (back-scattering) and/or by varying the instrumental resolution (time of flight spectroscopy) yield the activation parameters of molecular motions and the approximate structural correlation function in the time domain. The two methods are unified by a scaling function, which depends on the ratio of correlation time and instrumental resolution time. The elastic scattering concept is illustrated with a dynamic characterization of alanine-dipeptide, protein hydration water, and water-coupled protein motions of lysozyme, per-deuterated c-phycocyanin (CPC) and hydrated myoglobin. The complete elastic scattering function versus temperature, momentum exchange, and instrumental resolution is analyzed instead of focusing on a single cross-over temperature of mean square displacements at the apparent onset temperature of an-harmonic motions. Our method predicts the protein dynamical transition (PDT) at T{sub d} from the collective (α) structural relaxation rates of the solvation shell as input. By contrast, the secondary (β) relaxation enhances the amplitude of fast local motions in the vicinity of the glass temperature T{sub g}. The PDT is specified by step function in the elastic intensity leading from elastic to viscoelastic dynamic behavior at a transition temperature T{sub d}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of Molecular Size on Resolution in Charge Detection Mass Spectrometry

Instrumental resolution of Fourier transform-charge detection mass spectrometry instruments with electrostatic ion trap detection of individual ions depends on the precision with which ion energy is determined. Energy can be selected using ion optic filters or from harmonic amplitude ratios (HARs) that provide Fellgett’s advantage and eliminate the necessity of ion transmission loss to improve resolution. Unlike the ion energy-filtering method, the resolution of the HAR method increases with charge (improved S/N) and thus with mass. An analysis of the HAR method with current instrumentation indicates that higher resolution can be obtained with the HAR method than the best resolution demonstrated for instruments with energy-selective optics for ions in the low MDa range and above. However, this gain is typically unrealized because the resolution obtainable with molecular systems in this mass range is limited by sample heterogeneity. Here, this phenomenon is illustrated with both tobacco mosaic virus (0.6–2.7 MDa) and AAV9 (3.7–4.7 MDa) samples where mass spectral resolution is limited by the sample, including salt adducts, and not by instrument resolution. Nevertheless, the ratio of full to empty AAV9 capsids and the included genome mass can be accurately obtained in a few minutes from 1× PBS buffer solution and an elution buffer containing 300+ mM nonvolatile content despite extensive adduction and lower resolution. Empty and full capsids adduct similarly indicating that salts encrust the complexes during late stages of droplet evaporation and that mass shifts can be calibrated in order to obtain accurate analyte masses even from highly salty solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of quartz- and sapphire-based double-crystal high-resolution (~10 meV) RIXS monochromators under varying power loads

In the context of a novel, high-resolution resonant inelastic X-ray scattering spectrometer, a flat-crystal-based quartz analyzer system has recently been demonstrated to provide an unprecedented intrinsic-energy resolution of 3.9 meV at the Ir L 3 absorption edge (11.215 keV) [Kim et al. (2018) Sci. Rep. 8 , 1958]. However, the overall instrument resolution was limited to 9.7 meV because of an 8.9 meV incident band pass, generated by the available high-resolution four-bounce Si(844) monochromator. In order to better match the potent resolving power of the novel analyzer with the energy band pass of the incident beam, a quartz(309)-based double-bounce, high-resolution monochromator was designed and implemented, expected to yield an overall instrument resolution of 6.0 meV. The choice of lower-symmetry quartz is very attractive because of its wealth of suitable near-backscattering reflections. However, it was found that during room-temperature operation typical levels of incident power, barely affecting the Si monochromator, caused substantial thermal distortions in the first crystal of the quartz monochromator, rendering it practically unusable. Finite-element analyses and heat-flow analyses corroborate this finding. As a high-flux, lower resolution (15.8 meV) alternative, a two-bounce sapphire(078) version was also tested and found to be less affected than quartz, but notably more than silicon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A W-Geometry Ortho-TOF MS with High Resolution and Up to 100% Duty Cycle for MS/MS

Orthogonal injection time-of-flight (orthoTOF) mass spectrometry (MS) is the most prevalent form of TOFMS, owing to its greater control over incoming ion energy, the ability to correct for aberrations in incoming ion velocity and position, and its ability to provide an entire mass spectrum within a single scan. However, the duty cycle of orthoTOFMS is low compared with scanning analyzers, which can have 100% duty cycle when measuring a single type of ion. Typical duty cycles for orthoTOFMS range from 1% to 30%, depending on instrument geometry. Generally, as instrument resolution increases, duty cycle decreases. Additionally, the greatest duty cycle is achieved for the highest m/z ion recorded in the spectrum, and decreases for all other ions as a function of m/z. In a prior publication [Loboda, A.V.; Chernushevich, I.V. J. Am. Soc. Mass Spectrom. 20, 1342–1348 (20)], a novel trapping/release method for restoring the duty cycle of a V-geometry orthoTOFMS to near 100% (referred to as “Zeno pulsing”) was presented. Here, we apply that method to a W-TOF geometry analyzer with analog detection. Across a m/z range of 100–2000, sensitivity gains of ~5–20 are observed, for total ion currents approaching ~10{sup 7} ions·s{sup −1}. Zeno pulsing, or similar strategies for restoring duty cycle, will continue to be important as instrument resolution in orthoTOFMS is increased through the use of ion mirrors. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High resolution infrared and Raman spectra of {sup 13}C{sup 12}CD{sub 2}: The CD stretching fundamentals and associated combination and hot bands

Infrared and Raman spectra of mono {sup 13}C fully deuterated acetylene, {sup 13}C{sup 12}CD{sub 2}, have been recorded and analysed to obtain detailed information on the C—D stretching fundamentals and associated combination, overtone, and hot bands. Infrared spectra were recorded at an instrumental resolution ranging between 0.006 and 0.01 cm{sup −1} in the region 1800–7800 cm{sup −1}. Sixty new bands involving the ν{sub 1} and ν{sub 3} C—D stretching modes also associated with the ν{sub 4} and ν{sub 5} bending vibrations have been observed and analysed. In total, 5881 transitions have been assigned in the investigated spectral region. In addition, the Q branch of the ν{sub 1} fundamental was recorded using inverse Raman spectroscopy, with an instrumental resolution of about 0.003 cm{sup −1}. The transitions relative to each stretching mode, i.e., the fundamental band, its first overtone, and associated hot and combination bands involving bending states with υ{sub 4} + υ{sub 5} up to 2 were fitted simultaneously. The usual Hamiltonian appropriate to a linear molecule, including vibration and rotation l-type and the Darling–Dennison interaction between υ{sub 4} = 2 and υ{sub 5} = 2 levels associated with the stretching states, was adopted for the analysis. The standard deviation for each global fit is ≤0.0004 cm{sup −1}, of the same order of magnitude of the measurement precision. Slightly improved parameters for the bending and the ν{sub 2} manifold have been also determined. Precise values of spectroscopic parameters deperturbed from the resonance interactions have been obtained. They provide quantitative information on the anharmonic character of the potential energy surface, which can be useful, in addition to those reported in the literature, for the determination of a general anharmonic force field for the molecule. Finally, the obtained values of the Darling–Dennison constants can be valuable for understanding energy flows between independent vibrations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New developments in micro-X-ray diffraction and X-ray absorption spectroscopy for high-pressure research at 16-BM-D at the Advanced Photon Source

We report the monochromator and focusing mirrors of the 16-BM-D beamline, which is dedicated to high-pressure research with micro-X-ray diffraction (micro-XRD) and X-ray absorption near edge structure (XANES) (6-45 keV) spectroscopy, have been recently upgraded. Monochromatic X-rays are selected by a Si (111) double-crystal monochromator operated in an artificial channel-cut mode and focused to 5 μm × 5 μm (FWHM) by table-top Kirkpatrick-Baez type mirrors located near the sample stage. The typical X-ray flux is ~5 × 10 8 photons/s at 30 keV. The instrumental resolution, Δq/q max , reaches to 2 × 10 –3 and is tunable through adjustments of the detector distance and X-ray energy. The setup is stable and reproducible, which allows versatile application to various types of experiments including resistive heating and cryogenic cooling as well as ambient temperature compression. Transmission XANES is readily combined with micro-XRD utilizing the fixed-exit feature of the monochromator, which allows combined XRD-XANES measurements at a given sample condition.

47 OTHER INSTRUMENTATION↗

Ferrimagnetic spin waves in honeycomb and triangular layers of Mn{sub 3}Si{sub 2}Te{sub 6}.

A detailed analysis of the ferrimagnetic ground state of Mn 3 Si 2 Te 6 has been performed using inelastic neutron scattering. Although the proposed valence of the nominal Mn 2+ ions would have quenched orbital angular momentum, a significant exchange anisotropy exists in Mn 3 Si 2 Te 6 . This apparent exchange anisotropy is a manifestation of a weak spin-orbit coupling in the layered material. We employ a detailed simulation of the spin-wave spectrum coupling traditional refinement of dispersion parameters to image analysis techniques, while including Monte Carlo simulations of the instrumental resolution to accurately identify the exchange couplings to the third nearest neighbor. An independent validation of our results is made by comparing our final Hamiltonian to heat capacity measurements.

Sala, G.↗

Time-Resolved Infrared Reflectance Studies of the Dehydration-Induced Transformation of Uranyl Nitrate Hexahydrate to the Trihydrate Form

Uranyl nitrate is a key species in the nuclear fuel cycle. However, this species is known to exist in different states of hydration, including the hexahydrate ([UO2(NO3)2(H2O)6] often called UNH), the trihydrate [UO2(NO3)2(H2O)3 or UNT], and in very dry environments the dihydrate form [UO2(NO3)2(H2O)2]. Their relative stabilities depend on both water vapor pressure and temperature. In the 1950s and 1960s the different phases were studied by infrared transmission spectroscopy, but were limited both by instrumental resolution and by the ability to prepare the samples for transmission. We have revisited this problem using time-resolved reflectance spectroscopy, which requires no sample preparation and allows dynamic analysis while the sample is exposed to a flow of N2 gas. Samples of known hydration state were prepared and confirmed via X-ray diffraction patterns of known species. In reflectance mode the hexahydrate UO2(NO3)2(H2O)6 has a distinct uranyl asymmetric stretch band at 949.0 cm-1 that shifts to shorter wavelengths and broadens as the sample desiccates and recrystallizes to the trihydrate, first as a shoulder growing in on the blue edge but ultimately results in a doublet band with reflectance peaks at 966 and 957 cm-1. The data are consistent with transformation from UNH to UNT as UNT has two inequivalent UO22+ sites. The dehydration of UO2(NO3)2(H2O)6 to UO2(NO3)2(H2O)3 is both a structural and morphological change that has the lustrous lime green UO2(NO3)2(H2O)6 crystals changing to the matte greenish yellow of the trihydrate solid. The phase transformation and crystal structures were confirmed by density functional theory calculations and optical microscopy methods, both of which showed a transformation with two distinct sites for the uranyl cation in the trihydrate, with but one in the hexahydrate.

Johnson, Timothy J.↗

High-resolution grazing-incidence grating spectrometer for temperature measurements of low-Z ions emitting in the 100–300 Å spectral band

We have constructed a high-resolution grazing-incidence spectrometer designed for measuring the ion temperature of low-Z elements, such as Li{sup +} or Li{sup 2+}, which radiate near 199 Å and 135 Å, respectively. Based on measurements at the Livermore Electron Beam Ion Trap we have shown that the instrumental resolution is better than 48 mÅ at the 200 Å setting and better than 40 mÅ for the 135-Å range. Such a high spectral resolution corresponds to an instrumental limit for line-width based temperature measurements of about 45 eV for the 199 Å Li{sup +} and 65 eV for the 135 Å Li{sup 2+} lines. Recently obtained survey spectra from the Lithium Tokamak Experiment at the Princeton Plasma Physics Laboratory show the presence of these lithium emission lines and the expected core ion temperature of approximately 70 eV is sufficiently high to demonstrate the feasibility of utilizing our high-resolution spectrometer as an ion-temperature diagnostic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superresolution of a compact neutron spectrometer at energies relevant for fusion diagnostics

The ability to achieve resolution that is better than the instrument resolution (i.e., superresolution) is well known in optics, where it has been extensively studied. Unfortunately, there are only a handful of theoretical studies concerning superresolution of particle spectrometers, even though experimentalists are familiar with the enhancement of resolution that is achievable when appropriate methods of data analysis are used, such as maximum entropy and Bayesian methods. Knowledge of the superresolution factor is in many cases important. For example, in applications of neutron spectrometry to fusion diagnostics, the temperature of a burning plasma is an important physical parameter which may be inferred from the width of the peak of the neutron energy spectrum, and the ability to determine this width depends on the superresolution factor. Kosarev has derived an absolute limit for resolution enhancement using arguments based on a well known theorem of Shannon. Most calculations of superresolution factors in the literature, however, are based on the assumption of Gaussian, translationally invariant response functions and therefore not directly applicable to neutron spectrometers which typically have response functions not satisfying these requirements. In this work, we develop a procedure that allows us to overcome these difficulties and we derive estimates of superresolution for liquid scintillator spectrometers of a type commonly used for neutron measurements. Theoretical superresolution factors are compared to experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position Stability Monitoring of THEthe LCLS Undulator Quadrupoles

X-ray FELs demand that the positions of undulator components be stable to less than 1 {mu}m per day. Simultaneously, the undulator length increases significantly in order to saturate at x-ray wavelengths. To minimize the impact of the outside environment, the Linac Coherent Light Source (LCLS) undulator is placed underground, but reliable data about ground motion inside such a tunnel was not available in the required stability range during the planning phase. Therefore, a new position monitor system had been developed and installed with the LCLS undulator. This system is capable of measuring x, y, roll, pitch and yaw of each of the 33 undulator quadrupoles with respect to stretched wires. Instrument resolution is about 10 nm and instrument drift is negligible. Position data of individual quadrupoles can be correlated along the entire 132-m long undulator. The system has been under continuous operation since 2009. This report describes long term experiences with the running system and the observed positional stability of the undulator quadrupoles.

43 PARTICLE ACCELERATORS↗

Subwavenumber charge-coupled device spectrometer calibration using molecular iodine laser-induced fluorescence

Spectrometers configured with charge-coupled devices (CCD) or other array-based detectors require calibration to convert from the pixel coordinate to a spectral coordinate. A CCD calibration method well suited for Raman spectroscopy has been developed based on the 514.5 nm Ar{sup +} laser-induced fluorescence (LIF) spectrum of room-temperature molecular iodine vapor. Over 360 primary and secondary I{sub 2} LIF calibration lines spanning 510-645 nm were identified as calibrant peaks using an instrumental resolution of 1 cm{sup -1}. Two instrument calibration functions were evaluated with these peaks: a second-order polynomial and a function derived from simple optomechanical considerations. The latter function provided better fitting characteristics. Calibration using I{sub 2} LIF was tested with measurements of both laser light scattering and Raman spectra. The I{sub 2} LIF reference spectra and the signal spectra were recorded simultaneously, with no cross talk, by separating the two signals spatially along the vertical axis of the CCD imager. In this way, every CCD image could be independently calibrated. An accuracy and a precision of {+-}0.05 cm{sup -1} were achieved with this calibration technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗