Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrumentation for particle accelerators and storage rings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Experimental demonstration of optical stochastic cooling

Particle accelerators and storage rings have been transformative instruments of discovery, and, for many applications, innovations in particle-beam cooling have been a principal driver of that success. Stochastic cooling (SC), one of the most important conceptual and technological advances in this area cools a beam through granular sampling and correction of its phase-space structure, thus bearing resemblance to a ‘Maxwell’s demon’. The extension of SC from the microwave regime up to optical frequencies and bandwidths has long been pursued, as it could increase the achievable cooling rates by three to four orders of magnitude and provide a powerful tool for future accelerators. First proposed nearly 30 years ago, optical stochastic cooling (OSC) replaces the conventional microwave elements of SC with optical-frequency analogues and is, in principle, compatible with any species of charged-particle beam. Here we describe a demonstration of OSC in a proof-of-principle experiment at the Fermi National Accelerator Laboratory’s Integrable Optics Test Accelerator. The experiment used 100-MeV electrons and a non-amplified configuration of OSC with a radiation wavelength of 950 nm, and achieved strong, simultaneous cooling of the beam in all degrees of freedom. This realization of SC at optical frequencies serves as a foundation for more advanced experiments with high-gain optical amplification, and advances opportunities for future operational OSC systems with potential benefit to a broad user community in the accelerator-based sciences.

43 PARTICLE ACCELERATORS↗

The CMS Phase-1 Pixel Detector Upgrade

The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical stop of the LHC in 2016/2017. The upgraded CMS pixel detector is designed to cope with the higher instantaneous luminosities that have been achieved by the LHC after the upgrades to the accelerator during the first long shutdown in 2013–2014. Compared to the original pixel detector, the upgraded detector has a better tracking performance and lower mass with four barrel layers and three endcap disks on each side to provide hit coverage up to an absolute value of pseudorapidity of 2.5. This paper describes the design and construction of the CMS Phase-1 pixel detector as well as its performance from commissioning to early operation in collision data-taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anode sensitivity calibration of photomultiplier tubes used as a readout of the ELOSS detector

We present and discuss the methodology and results for an anode sensitivity calibration of Photomultiplier Tubes (PMTs) that serve as the optical readout of the Energy Loss Optical Scintillation System (ELOSS). The ELOSS detector, under development at the Facility for Rare Isotope Beams (FRIB), is a gaseous Xe scintillation-based detector designed to identify the atomic number (Z) of nuclear reaction fragments by energy-loss measurement. Variation in the anode sensitivity from tube to tube of commercially available PMTs limits ELOSS from reaching its ultimate Z resolution. A methodical approach to calibrating PMT anode sensitivities to a single target value by systematic PMT gain corrections is presented. Although the calibration process is discussed in terms of its impact on ELOSS performance, the presented method is applicable to any optical detector system composed of a large number of PMTs needing anode sensitivity calibration.

Instrumentation for heavy-ion accelerators↗

Numerical modeling of a proton spin-flipping system in the spin transparency mode at an integer spin resonance in JINR's Nuclotron

In this paper we propose a lattice insertion for the Nuclotron ring called a “spin navigator” that can adjust any direction of the proton polarization in the orbital plane using weak solenoids. The polarization control is realized in the spin transparency mode at the energy of 108 MeV, which corresponds to the integer spin resonance γ G = 2. The requirements on the navigator solenoid fields are specified considering the criteria for stability of the spin motion during any manipulation of the polarization direction in an experiment. Additionally, this paper presents the results of numerical modeling of the proton spin dynamics in the Nuclotron ring operated in the spin transparency mode. The verified spin navigator is aimed at an experimental study of a spin-flipping system using the Nuclotron ring. The results are relevant to the NICA (JINR), EIC (BNL) and COSY (FZJ) facilities where the spin transparency mode can be applied for polarization control.

47 OTHER INSTRUMENTATION↗

On the possibility of footprint compression with one lens in nonlinear accelerator lattice

Electromagnetic interaction of colliding beams along with other nonlinear fields often limits the beams' lifetimes and luminosities. Nonlinearities result in the spread of betatron frequencies (footprint) and, thus, may enhance dynamic diffusion of particles due to high order resonances. One of the possible ways to eliminate nonlinearities and overcome the corresponding difficulties is compensation of nonlinear forces, but, in practice, it is hardly possible to obtain exact linearity of the system. The compensation with a single nonlinear lens cannot cope with distributed nonlinearities, nonlinearities due to parasitic crossings, etc. Here, we present a method to compute parameters of nonlinear element (lens) that eliminates both the footprint and resonance strength without achieving full compensation.

43 PARTICLE ACCELERATORS↗

High-accuracy absolute magnetometry with application to the Fermilab Muon g-2 experiment

We present details of a high-accuracy absolute scalar magnetometer based on pulsed proton NMR. The B-field magnitude is determined from the precession frequency of proton spins in a cylindrical sample of water after accounting for field perturbations from probe materials, sample shape, and other corrections. Features of the design, testing procedures, and corrections necessary for qualification as an absolute scalar magnetometer are described. The device was tested at B = 1.45 T but can be modified for a range exceeding 1–3 T. The magnetometer was used to calibrate other NMR magnetometers and measure absolute magnetic field magnitudes to an accuracy of 19 parts per billion as part of a measurement of the muon magnetic moment anomaly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary results of the 2023 International Fermilab Booster Studies

Here, an overview is given of the methods and preliminary results from dedicated beam studies on three topics conducted over five days in July 2023. In the first study, the Fermilab Booster magnets were held constant at magnetic fields corresponding to the injection energy. The beam loss and emittance growth were observed under varying intensity, tunes, and sextupole resonances. The corresponding beam conditions were also simulated with the MADX-SC code [1]. In the second study, measurements of the vertical half-integer resonance and correction methods are conducted for high-intensity beams ramping in the Booster. Finally, syncho-betatron instabilities are observed during transition-crossing in the Booster under strong space-charge conditions.

43 PARTICLE ACCELERATORS↗

The Linac Extension Area at the Advanced Photon Source

The Linac Extension Area has been developed into a beamline area for testing accelerator components and techniques. Beginning commissioning activities in February 2023, we have delivered the first electron beam to the Linac Extension Area at the Advanced Photon Source at 425 MeV. In the present work, we summarise the principal accelerator components and review safety controls of the Linac Extension Area.

47 OTHER INSTRUMENTATION↗

Measurement of the fractional radiation length of a pixel module for the CMS Phase-2 upgrade via the multiple scattering of positrons

High-luminosity particle collider experiments such as theones planned at the High-Luminosity Large Hadron Collider requireever-greater vertexing precision of the tracking detectors,necessitating reductions in the material budget of the detectors.Traditionally, the fractional radiation length (x/X$_{0}$) ofdetectors is either estimated using known properties of theconstituent materials, or measured in dedicated runs of the finaldetector. In this paper, we present a method of direct measurementof the material budget of a CMS prototype module designed for thePhase-2 upgrade of the CMS detector using a 40–65 MeV positronbeam. A total of 630 million events were collected at the PaulScherrer Institut PiE1 experimental area using a three-planetelescope consisting of the prototype module as the central plane,surrounded by two MALTA monolithic pixel detectors. Fractionalradiation lengths were extracted from scattering angle distributionsusing the Highland approximation for multiple scattering. Astatistical technique recovered runs suffering from triggerdesynchronisation, and several corrections were introduced tocompensate for local inefficiencies related to geometric and beamshape constraints. Two regions of the module were surveyed andyielded average x/X$_{0}$ values of (0.72 ± 0.05)% and(0.95 ± 0.09)%, which are compatible with empirical estimatesfor these regions computed from known material properties of 0.753%and 0.892%, respectively. Two types of higher-granularity maps ofthe fractional radiation length were produced, subdivided eitherinto rectangular regions of uniform size, or polygonal-shapedregions of uniform material composition. The results bode well forthe CMS Phase-2 upgrade modules, which will play a key role in theminimisation of the material of the upgraded detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design of Optical Stochastic Cooling for IOTA

This report presents a journal version of the Design Report on the Optical Stochastic Cooling experiment to be carried out at IOTA ring in Fermilab later this year. It discusses the theory which experiment is based on, beam parameters, major requirements to the storage ring systems and technical details of the experiment implementation.

Instrumentation for particle accelerators↗

Recent Advances in Our Understanding of the Earth's Radiation Belts

The Earth's radiation belts were discovered by James van Allen more than fifty years ago and are a home to a plethora of fascinating processes ranging from low energy cold plasma to relativistic and ultra-relativistic particle populations. The traditional morphological picture of the radiation belts is that of an outer belt comprising mostly of electrons and an inner belt comprising mostly of protons with a so-called slot region separating the two. The inner belt is somewhat stable, while the outer radiation belt is very dynamical and shows variability in energetic electron populations over a wide range of energies, intensities, and time scales ranging from minutes, days and even years. This variability is due to dynamical processes of energization and loss with a variety of plasma waves playing an important and crucial role. The traditional picture has recently been challenged with new observations coming from the twin spacecraft mission, Van Allen Probes launched in the fall of 2012, which carries a comprehensive suite of instruments that measure particles and plasma waves. In more than 5 years of observations Van Allen Probes has advanced our understanding of fundamental questions regarding the acceleration and loss of outer Van Allen belt electron population. Van Allen Probes observations have also revealed new phenomena such as the "electron Storage ring", and the "impenetrable barrier". This article reviews electron dynamics in the Van Allen belts focusing on van Allen Probes observations and discuss exciting new ways of advancing radiation belt science with CubeSats and CubeSat constellations.

Relativistic electrons↗

IOTA Run 2 Beam Dynamics Studies in Nonlinear Integrable Systems

Nonlinear integrable optics is a promising design approach for suppressing fast collective instabilities. To study it experimentally, a new storage ring, the Integrable Optics Test Accelerator (IOTA), was built at Fermilab. IOTA has recently completed its second scientific run, incorporating many hardware and instrumentation improvements. This report presents the results of the two integrable optics experiments - the quasi-integrable Henon-Heiles octupole system and the fully integrable Danilov-Nagaitsev system. We demonstrate tune spread and dynamic aperture in agreement with tracking simulations, and a stable crossing of the integer resonance. Based on recovered single-particle phase space dynamics, we show improved invariant jitter consistent with intended effective Hamiltonian. We conclude by outlining future plans and efforts towards proton studies and larger designs.

43 PARTICLE ACCELERATORS↗

1972713

Energy-frontier particle accelerators are among the most exciting, complex, challenging, and expensive research instruments performing high precision measurements confirming the fundamentals of the physics and broadening new research horizons. Currently the highest energy machines (under design or commissioned), from multi-GeV to several TeV, (ILC, FCC, CLIC) capable of searching for the most basic building blocks of matter are either driven by circular or linear accelerators [1-6]. Here (see also [7,8]) we suggest a novel design of circular-linear accelerator based on the merging of the weakly emitting, low-energy storage rings and energy recovery linear accelerators. To enable the operation of such a system and in particular the energy recovery from spent, high-intensity beams the use of the dual-axis asymmetric cavities is suggested. Merging circular and linear systems, and applications of dual axes cavities, aims to resolve both scientific and societal challenges. The merge of the systems will allow: 1) maintain high beam quality, high luminosity, and high energy efficiency; 2) offer a ?flexible? energy management via ?separation? of the collider and storage rings operations; 3) attract private partners via use of the storage rings to drive the next generation of the photon factories. The concept presented can be potentially used to reach ultimate energy frontiers in high-energy physics as well as to drive next generation light sources. We note that the numbers which will be presented are for illustration purpose and can be improved further.

Konoplev, I.↗

Observation of Undulator Radiation Generated by a Single Electron Circulating in a Storage Ring and Possible Applications

An experimental study into the undulator radiation, generated by a single electron was carried out at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. The individual photons were detected by a Single Photon Avalanche Diode (SPAD) at an average rate of 1 detection per 300 revolutions in the ring. The detection events were continuously recorded by a picosecond event timer for as long as 1 minute at a time. The collected data were used to test if there is any deviation from the classically predicted Poissonian photostatistics. It was motivated by the observation * of sub-Poissonian statistics in a similar experiment. The observation * could be an instrumentation effect related to low detection efficiency and long detector dead time. In our experiment, the detector (SPAD) has a much higher efficiency (65%) and a much lower dead time. In addition, we show that the collected data (recorded detection times) can be used to study the synchrotron motion of a single electron and infer some parameters of the ring. For example, by comparing the results of simulation and measurement for the synchrotron motion we were able to estimate the magnitude of the RF phase jitter.

43 PARTICLE ACCELERATORS↗

The fast non-ferric kicker system for the Muon g–2 Experiment at Fermilab

Here we describe the installation, commissioning, and characterization of the new injection kicker system in the Muon g – 2 Experiment (E989) at Fermilab, which makes a precision measurement of the muon magnetic anomaly. Three Blumlein pulsers drive each of the 1.27-m-long non-ferric kicker magnets, which reside in a storage ring vacuum (SRV) that is subjected to a 1.45 T magnetic field. The new system has been redesigned relative to Muon g – 2 ’s predecessor experiment, and we present those details in this manuscript.

43 PARTICLE ACCELERATORS↗

Beam physics research with the IOTA electron lens

The electron lens in the Fermilab Integrable Optics Test Accelerator (IOTA) will enable new research in nonlinear integrable optics, space-charge compensation, electron cooling, and the stability of intense beams. This research addresses scientific questions on high-brightness beams and operational challenges of high-power accelerators for nuclear and particle physics. We review the roles that electron lenses play in this field and the physical principles behind their applications. The design criteria and specifications for the IOTA storage ring and electron lens are then discussed. We conclude with a description of the components of the apparatus.

43 PARTICLE ACCELERATORS↗

Diagnostic Systems in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was measured with a precision of $0.20$~parts per million (ppm) by the Fermilab's Muon g-2 (E989) experiment. The final goal of the E989 experiment is to reach a precision of $0.14$~ppm. The experiment is based on the measurement of the muon spin anomalous precession frequency, $\omega_a$, based on the arrival time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters, placed around the inner circumference of a $14$~m diameter storage ring, and on the precise knowledge of the storage ring magnetic field and of the beam time and space distribution. Achieving this level of precision requires strict control over systematics, which is ensured through several diagnostic devices. At the accelerator level, these devices monitor the quality of the injected beam (e.g., verifying that it has the correct momentum), while at the detector level, they track both the magnetic field and the gain of the calorimeters. In this work the devices and techniques used by the E989 experiment will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the muon anomalous precession frequency at the Muon g − 2 Experiment at Fermilab

The anomalous magnetic moment of the muon, $a_\mu = \frac{g-2}{2}$ is the fractional deviation of the muon $g$-factor from the value of 2. It emerges as the cumulative effect of the virtual particles participating in the muon interaction with a magnetic field via quantum loop corrections. Its value encodes all the possible interactions between the virtual particles and, for this reason, represents an important test of the Standard Model (SM). In particular, any deviation from the SM theoretical evaluation could be due to new physics contributions. The new Muon $g-2$ (E989) Experiment at Fermilab is currently operating to repeat and improve the previous E821 experiment at Brookhaven National Laboratory (BNL), aiming to reduce the experimental error by a factor of 4 to the final accuracy of 140 parts per billion (ppb). On April 7th, 2021, the E989 collaboration published the first result based on the first year of data taking (Run-1), measuring $a_\mu = 0.001~165~920~40(54)$ with a precision of 460 ppb. The measured value is consistent with the BNL measurement and strengthens the long-standing tension with the data-driven SM prediction to a combined discrepancy of 4.2$\sigma$. On the theory side, however, new efforts involving lattice-QCD techniques are starting to question the current consensus on the theoretical prediction, demanding new improvements on both the experimental and theoretical sides. The E989 collaboration is now finalizing the analysis of Run-2 and Run-3 data and a new publication is expected in the first half of 2023 with a combined statistical uncertainty of 200 ppb. The anomalous magnetic moment $a_\mu$ is measured as the ratio between the muon spin anomalous precession frequency, $\omega_a$, and the average magnetic field experienced by the muons as they circulate in the storage ring. This thesis presents a precession frequency analysis of the Run-1 data and an evaluation of the related systematic uncertainties. A new positron reconstruction developed for the analysis of the subsequent data-taking periods, aiming to reduce some of the major systematic uncertainties of the $\omega_a$ measurement, is presented. The author's involvement in the production of the Run-2/5 data and in the precise calibration of the detectors is discussed. Finally, the complete Run-1 $a_\mu$ result is presented.

43 PARTICLE ACCELERATORS↗